/// Copyright (c) 2013-2015 Sensus Metering Systems
|
|
///
|
|
using System;
|
|
using log4net;
|
|
|
|
namespace TBF.BenchControl.MettlerToledo.Standard
|
|
{
|
|
public class GetSerNumOp : IOperation
|
|
{
|
|
private static readonly ILog log = LogManager.GetLogger(typeof(GetSerNumOp));
|
|
public override string ToString() { return string.Format("GetSerNumOp(.,.)"); }
|
|
|
|
/// Set by the constructor
|
|
BalanceNewDev scale;
|
|
string serialNumber;
|
|
|
|
/// <summary>
|
|
/// Events: BalanceDone, Error
|
|
/// </summary>
|
|
/// <param name="scale">Balance device instance</param>
|
|
/// <param name="serialNumber">Reference to the serialNumber</param>
|
|
public GetSerNumOp(BalanceNewDev scale, ref string serialNumber)
|
|
{
|
|
if (scale == null) throw new ArgumentNullException("balanceDev");
|
|
this.scale = scale;
|
|
|
|
this.serialNumber = serialNumber;
|
|
|
|
log.Debug(this.ToString());
|
|
}
|
|
|
|
/// <summary>Start this operation</summary>
|
|
public void Start()
|
|
{
|
|
log.DebugFormat("{0} - Start()", scale.Name);
|
|
scale.GetSerialNumber();
|
|
}
|
|
|
|
/// <summary>Run this operation</summary>
|
|
/// <returns>
|
|
/// Event.None
|
|
/// Event.BalanceDone
|
|
/// </returns>
|
|
public Event Run()
|
|
{
|
|
log.DebugFormat("{0} - GetSerNumOp.Run() ... MsrmntState = {1}", scale.Name, scale.MsrmntState);
|
|
|
|
if (scale.MsrmntState == MsrmntState.Valid)
|
|
{
|
|
serialNumber = scale.SerialNumber;
|
|
return Event.BalanceDone; /// S/N read successful
|
|
}
|
|
else if (scale.MsrmntState == MsrmntState.Failed)
|
|
{
|
|
return Event.Error; /// S/N read failed
|
|
}
|
|
else
|
|
{
|
|
return Event.Busy; /// No result yet
|
|
}
|
|
}
|
|
|
|
/// <summary>Stop this operation</summary>
|
|
public void Stop()
|
|
{
|
|
log.DebugFormat("{0} - Stop()", scale.Name);
|
|
}
|
|
}
|
|
}
|