/// Copyright (c) 2018 Sensus Slovensko a.s.
|
|
///
|
|
using System;
|
|
using System.Collections.Generic;
|
|
using System.Text;
|
|
using log4net;
|
|
using Config.Entities;
|
|
using TBF.BenchControl;
|
|
using TBF.Boxes;
|
|
using TBF.Resources;
|
|
using TBF.UiBridge;
|
|
using TBF.BenchControl.GenericDevices;
|
|
|
|
namespace TBF.BenchControl.TestMethods.PulsesTest
|
|
{
|
|
public class PulseOutputsTestSeq : Sequences.SequenceBase
|
|
{
|
|
private static readonly ILog log = LogManager.GetLogger(typeof(PulseOutputsTestSeq));
|
|
|
|
System.Windows.Forms.Form modelessDlg;
|
|
///
|
|
delegate void ErrorsFormDlgt(PulseOutputsTestSeq myRef, IList<GenericDevices.IWaterMeter> waterMeters);
|
|
///
|
|
void OpenWMPulsesForm(PulseOutputsTestSeq myRef, IList<GenericDevices.IWaterMeter> waterMeters)
|
|
{
|
|
#pragma warning disable 162 /// Disables 'Unreachable code detected' warning
|
|
|
|
if (Config.Data.WMsCount > 12)
|
|
{
|
|
myRef.modelessDlg = new WMPulsesForm24(waterMeters);
|
|
}
|
|
else if (Config.Data.WMsCount > 6)
|
|
{
|
|
myRef.modelessDlg = new WMPulsesForm12(waterMeters);
|
|
}
|
|
else
|
|
{
|
|
myRef.modelessDlg = new WMPulsesForm(waterMeters);
|
|
}
|
|
|
|
#pragma warning restore 162 /// Disables 'Unreachable code detected' warning
|
|
|
|
modelessDlg.Show();
|
|
}
|
|
|
|
/// <summary>
|
|
/// Adjustment method sequence
|
|
/// </summary>
|
|
/// <param name="test">Test entity</param>
|
|
/// <returns>
|
|
/// Event.Done . . . . . . . OK
|
|
/// Event.UiCmdStop . . . . Stopped by the user using the on-screen button STOP
|
|
/// Event.OpArgumentError . Target flow is out of range
|
|
/// Event.Error . . . . . . Unspecified error
|
|
/// </returns>
|
|
public IList<Event> Execute(Test test, int repetitionNr, bool isLastRepetition, TestParams testParams, DebugMode mode)
|
|
{
|
|
float simulatedError = 4.5f; /// %
|
|
bool stopCycle = false;
|
|
|
|
int rangeIx = 0; /// Default range, used for non-Elde flowmeters
|
|
if (outPath.FlowMeter is Elde.FlowMeter.FlowMeter)
|
|
{
|
|
Elde.FlowMeter.FlowMeter eldeFM = outPath.FlowMeter as Elde.FlowMeter.FlowMeter;
|
|
rangeIx = -1; /// Indicates invalid range
|
|
for (int r = 0; r <= 5; r++)
|
|
{
|
|
if (eldeFM.RangeEnabled(r) && eldeFM.GetTempLo(r) <= test.TempLimLo
|
|
&& eldeFM.GetTempHi(r) >= test.TempLimHi)
|
|
{
|
|
rangeIx = r;
|
|
}
|
|
}
|
|
|
|
if (rangeIx == -1)
|
|
{
|
|
Bridge.OnError(this, Strings.Flow_meter_temperature_range_does_not_fit_this_test_conditions);
|
|
return new List<Event> { Event.ConfigurationError };
|
|
}
|
|
}
|
|
|
|
IList<Event> e; /// Events from currently running operations
|
|
Event retVal = Event.Done;
|
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
|
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, false);
|
|
|
|
|
|
int[] filters = new int[] { 0, 0, 0, 0, 0, 0, 0, 0 };
|
|
if (sensPath != null && sensPath.RegisterReaders != null)
|
|
{
|
|
foreach (var rr in sensPath.RegisterReaders)
|
|
{
|
|
IRegReaderPulses eldeRR = rr as IRegReaderPulses;
|
|
if ((eldeRR != null) && (eldeRR.Position >= 1) && (eldeRR.Position <= 8))
|
|
{
|
|
filters[eldeRR.Position - 1] = eldeRR.Filter;
|
|
}
|
|
}
|
|
}
|
|
|
|
cBrd.SetFiltersPidShortPulses(filters, outPath.PidCoef, (test.TolerRed == 0) ? 0 : 1);
|
|
|
|
IList<IOperation> readTempPressOps = new List<IOperation>();
|
|
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
|
if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
|
if (outPath.TempDiv != null) readTempPressOps.Add(outPath.TempDiv.ReadTempOp(ref TempDiv));
|
|
if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
|
if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
|
if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
|
|
|
LtrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
|
int totalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f);
|
|
|
|
/// Start the test, initialize test results
|
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath, totalPulses));
|
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
|
|
|
/// Read pressure and temperature once before calling Bridge.OnTestSelected(...)
|
|
State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name))
|
|
.AddOperation(checkUiOp)
|
|
.AddOperations(readTempPressOps)
|
|
.EnterState();
|
|
do {
|
|
e = StateMachine.WaitRunDevsRunOps();
|
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
|
}
|
|
while (e.Contains(Event.Busy));
|
|
|
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
|
TestStartTime = DateTime.Now;
|
|
int flowSetTime0 = StateMachine.Time;
|
|
|
|
//------------------------------------------------
|
|
Bridge.OnActivity(this, Strings.Starting_the_pump);
|
|
//------------------------------------------------
|
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
|
///
|
|
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
|
.AddOperation(checkUiOp)
|
|
.AddOperations(readTempPressOps)
|
|
//.AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
|
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
|
.EnterState();
|
|
do {
|
|
e = StateMachine.WaitRunDevsRunOps();
|
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
|
|
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
|
|
|
}
|
|
while (e.Contains(Event.ValvesBusy) /* || !e.Contains(Event.AllPositionsReached)*/);
|
|
|
|
|
|
if (test.TimePump2StartV > 0)
|
|
{
|
|
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
|
.AddOperation(checkUiOp)
|
|
.AddOperations(readTempPressOps)
|
|
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
|
.EnterState();
|
|
do {
|
|
e = StateMachine.WaitRunDevsRunOps();
|
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
|
|
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
|
}
|
|
while (!e.Contains(Event.TimerExpired));
|
|
}
|
|
|
|
|
|
if (benchPath.StopBFValve != null)
|
|
{
|
|
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
|
.AddOperation(checkUiOp)
|
|
.AddOperations(readTempPressOps)
|
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
|
.EnterState();
|
|
do {
|
|
e = StateMachine.WaitRunDevsRunOps();
|
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
|
}
|
|
while (!e.Contains(Event.ValvesSet));
|
|
}
|
|
|
|
|
|
if (test.TimeBeforeFlow > 0)
|
|
{
|
|
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
|
.AddOperation(checkUiOp)
|
|
.AddOperations(readTempPressOps)
|
|
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
|
.EnterState();
|
|
do {
|
|
e = StateMachine.WaitRunDevsRunOps();
|
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
|
|
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
|
}
|
|
while (!e.Contains(Event.TimerExpired));
|
|
}
|
|
|
|
|
|
setting_flow:
|
|
|
|
//------------------------------------------------
|
|
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
|
//------------------------------------------------
|
|
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
|
.AddOperation(checkUiOp)
|
|
.AddOperations(readTempPressOps)
|
|
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, RefFlow, FlowSettingTimeoutSec))
|
|
.EnterState();
|
|
do {
|
|
e = StateMachine.WaitRunDevsRunOps();
|
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
|
|
|
if (e.Contains(Event.OpArgumentError)) { retVal = Event.OpArgumentError; goto stopTest; }
|
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
|
if (e.Contains(Event.RegulValveTimeOut))
|
|
{
|
|
Bridge.OnError(this, Strings.Flow_adjustment_failed);
|
|
retVal = Event.RecoverableError;
|
|
goto stopTest;
|
|
}
|
|
if (e.Contains(Event.Next)) goto flow_set;
|
|
}
|
|
while (!e.Contains(Event.FlowReached));
|
|
|
|
flow_set:
|
|
|
|
int flowSetTime = StateMachine.Time - flowSetTime0;
|
|
|
|
if (test.DoControlWaterTemp && benchPath.TempMtrUp != null && benchPath.TempMtrDown != null)
|
|
{
|
|
//---------------------------------------------------
|
|
Bridge.OnActivity(this, Strings.Setting_temperature);
|
|
//---------------------------------------------------
|
|
|
|
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
|
.AddOperation(checkUiOp)
|
|
.AddOperations(readTempPressOps)
|
|
.EnterState();
|
|
do {
|
|
e = StateMachine.WaitRunDevsRunOps();
|
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
|
if (e.Contains(Event.Next)) goto temperature_set;
|
|
|
|
if ((test.TempLimLo <= TempUp.Val) && (TempUp.Val <= test.TempLimHi) &&
|
|
(test.TempLimLo <= TempDown.Val) && (TempDown.Val <= test.TempLimHi))
|
|
{
|
|
goto temperature_set;
|
|
}
|
|
}
|
|
while (true);
|
|
}
|
|
|
|
temperature_set:
|
|
|
|
/// Show the modeless dialog with error indication
|
|
Program.MainWnd.Invoke(new ErrorsFormDlgt(OpenWMPulsesForm), new object[] { this, WaterMeters });
|
|
|
|
loop:
|
|
int time = StateMachine.Time;
|
|
double currentFlow = RefFlow.Val;
|
|
|
|
|
|
///
|
|
/// Prepare cameras, ROI-s and measurementOperations
|
|
///
|
|
|
|
/// Find ROI-s
|
|
IList<GenericDevices.IRegReaderLiveCamera> rois = new List<GenericDevices.IRegReaderLiveCamera>();
|
|
foreach (var rr in sensPath.RegisterReaders)
|
|
{
|
|
GenericDevices.IRegReaderLiveCamera cameraRoI = rr as GenericDevices.IRegReaderLiveCamera;
|
|
if ((cameraRoI != null) && cameraRoI.Detected)
|
|
{
|
|
rois.Add(cameraRoI);
|
|
}
|
|
}
|
|
|
|
/// Find cameras
|
|
IList<GenericDevices.ICamera> cameras = new List<GenericDevices.ICamera>();
|
|
foreach (var roi in rois)
|
|
{
|
|
if (roi.Camera != null && !cameras.Contains(roi.Camera))
|
|
{
|
|
roi.Camera.ClearRoiParams();
|
|
cameras.Add(roi.Camera);
|
|
}
|
|
}
|
|
|
|
/// Register ROI-parameters to cameras
|
|
foreach (var roi in rois) roi.RegisterRoiToCamera();
|
|
|
|
/// Prepare measurementOperations
|
|
IList<IOperation> measureOperations = new List<IOperation>();
|
|
foreach (var camera in cameras) measureOperations.Add(camera.MeasurementOp());
|
|
|
|
|
|
|
|
//------------------------------------------------
|
|
Bridge.OnActivity(this, Strings.Test_in_progress);
|
|
//------------------------------------------------
|
|
if (mode == Config.Entities.DebugMode.Simulate)
|
|
{
|
|
/// TODO: Reimplement
|
|
//tstRslt = MakeSimulated(test, 1, simulatedError);
|
|
simulatedError *= 0.6f;
|
|
|
|
State.Create(string.Format("{0}({1}) : Simulating the test", test.Method, test.Name))
|
|
.AddOperation(checkUiOp)
|
|
.AddOperations(readTempPressOps)
|
|
.AddOperation(new Operations.TimerOp(5))
|
|
.EnterState();
|
|
do {
|
|
e = StateMachine.WaitRunDevsRunOps();
|
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
|
}
|
|
while (!e.Contains(Event.TimerExpired));
|
|
}
|
|
else
|
|
{
|
|
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
|
.AddOperation(checkUiOp)
|
|
.AddOperations(readTempPressOps)
|
|
.AddOperations(measureOperations)
|
|
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Synchro, test.Qfrom, test.Qto, totalPulses))
|
|
.EnterState();
|
|
do {
|
|
e = StateMachine.WaitRunDevsRunOps();
|
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
|
}
|
|
while (!e.Contains(Event.MeasurementStarted));
|
|
|
|
/// Measurement loop - preparation
|
|
readRegistersOp = new Operations.ReadMoreRegistersOp(sensPath.RegisterReaders);
|
|
queryEnd1 = cBrd.QueryMeasurementEndOp();
|
|
queryEnd2 = cBrd.QueryMeasurementEndOp();
|
|
|
|
StartNewStatistics(StateMachine.Time, BatchRslts.Batch.BatchNr, test.Name, repetitionNr, 0);
|
|
|
|
/// Measurement loop - begin
|
|
while (true)
|
|
{
|
|
//--------------------------------
|
|
switch (ReadRegistersTempPressAmbient(measureOperations, true))
|
|
{
|
|
case Event.Error: { retVal = Event.Error; goto stopTest; }
|
|
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
|
|
case Event.MeasurementCompleted: goto one_test_completed;
|
|
}
|
|
|
|
RefFreq.Val = cBrd.ReferenceFreq;
|
|
RefFlow.Val = cBrd.ReferenceFlow;
|
|
UpdateAllStatistics(StateMachine.Time);
|
|
|
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
|
}
|
|
/// Measurement loop - end
|
|
|
|
one_test_completed:
|
|
|
|
//------------------------------------------------
|
|
Bridge.OnActivity(this, Strings.Adjustment_in_progress);
|
|
//------------------------------------------------
|
|
|
|
TestEndTime = DateTime.Now;
|
|
|
|
/// Make sure the CycleBeginForm is closed so that water meter data (s/n) can be copied into results
|
|
if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stopTest;
|
|
|
|
///
|
|
/// Populate TestResult data entity with data
|
|
///
|
|
Results.Entities.TestRslt tstRslt = BatchRslts.GetTestRslt(testName, test.Part);
|
|
|
|
if (tstRslt != null)
|
|
{
|
|
Results.Utils.GetCounterStates(tstRslt, Program.LocalSettings.Counters);
|
|
UpdateTempPressDensAmb(tstRslt);
|
|
|
|
/// Main results
|
|
tstRslt.MethodClass = TbfComponents.FindComponent(test.Method).ClassName;
|
|
tstRslt.StartTime = TestStartTime;
|
|
tstRslt.EndTime = TestEndTime;
|
|
tstRslt.FlowSetTime = flowSetTime;
|
|
tstRslt.TestTime = cBrd.TTime; /// [s] measurement time
|
|
tstRslt.PulsesMaster = Convert.ToDouble(cBrd.EtPulses(0)); /// Pulses of the master flow meter (test total)
|
|
tstRslt.MassStartRaw = 0;
|
|
tstRslt.MassStart = 0;
|
|
tstRslt.MassEndRaw = 0;
|
|
tstRslt.MassEnd = 0;
|
|
tstRslt.MassOfEvapWater = 0;
|
|
tstRslt.FlowMass = 0; /// [kg/h]
|
|
tstRslt.FlowVolume = 3.6 * LtrPerRefPulse * cBrd.EtPulses(0) / tstRslt.TestTime; /// [m3/h]
|
|
tstRslt.VolumeMaster = LtrPerRefPulse * tstRslt.PulsesMaster; /// [l] volume from the master flow meter
|
|
tstRslt.ConstMasterRaw = outPath.FlowMeter.LtrPerPulse; /// Uncorrected master flowmeter coefficient
|
|
tstRslt.ConstMasterCorr = outPath.FlowMeter.LtrPerPulseCorrected(tstRslt.FlowVolume, rangeIx); /// Corrected master pulses per liter
|
|
tstRslt.ConstMaster = tstRslt.ConstMasterCorr; /// Corrected master pulses per liter
|
|
tstRslt.VolumeCTV = tstRslt.ConstMaster * tstRslt.PulsesMaster; /// [l] 1000.0f is because density is in [kg/m3]
|
|
tstRslt.ErrorMaster = 0.0f; /// Cannot be determined without the collected water mass measurement
|
|
|
|
tstRslt.FlowMean = Convert.ToSingle(RefFlowStat.Average);
|
|
tstRslt.FlowStart = Convert.ToSingle(RefFlowStat.First);
|
|
tstRslt.FlowEnd = Convert.ToSingle(RefFlowStat.Last);
|
|
tstRslt.FlowMin = Convert.ToSingle(RefFlowStat.Min);
|
|
tstRslt.FlowMax = Convert.ToSingle(RefFlowStat.Max);
|
|
|
|
tstRslt.DiverterStart = 0;
|
|
tstRslt.DiverterEnd = 0;
|
|
long infoFlags = 0;
|
|
tstRslt.ErrorFlags = (ErrorFlagsComp != null) ? ErrorFlagsComp.GetErrorFlags(tstRslt, false, false, 0, 0, out infoFlags, out stopCycle) : 0;
|
|
tstRslt.InfoFlags = infoFlags;
|
|
|
|
for (int i = 0; i < BatchRslts.WMPositionsCount; i++)
|
|
{
|
|
if (!test.IsPartCompatible(Utils.PartNr(i + 1, BatchRslts.Batch.Compound))) continue;
|
|
|
|
Results.Entities.MeterTestRslt meterRslt = BatchRslts.GetMeterTestRslt(testName, i, CompoundMeterId.Single);
|
|
GenericDevices.IRegReader regReader = sensPath.RegisterReaders[i];
|
|
|
|
if (meterRslt != null && regReader != null)
|
|
{
|
|
meterRslt.RegReaderType = (int)regReader.RegisterReaderType;
|
|
meterRslt.PulsesPerLiter = regReader.PulsesPerLtr;
|
|
meterRslt.PulsesMeter = Convert.ToDouble(regReader.WMPulses);
|
|
meterRslt.PulsesMaster = Convert.ToDouble(regReader.WMRefPulses);
|
|
meterRslt.VolumeStart = 0; /// liter
|
|
meterRslt.VolumeEnd = 0; /// liter
|
|
meterRslt.VolumeMeter = meterRslt.PulsesMeter * regReader.LtrsPerPulse; /// liter
|
|
meterRslt.VolumeRef = meterRslt.PulsesMaster * tstRslt.ConstMaster; /// liter
|
|
meterRslt.TestTime = cBrd.ImpulseTime(i + 1);
|
|
meterRslt.Error = 0;
|
|
meterRslt.Passed = (meterRslt.PulsesMeter >= (double)testParams.MinPulsesCount);
|
|
meterRslt.TestDone = true;
|
|
tstRslt.TestDone = true;
|
|
}
|
|
}
|
|
|
|
tstRslt.Components = Results.Entities.Components
|
|
.UpdateList(BatchRslts.ComponentsList,
|
|
new Results.Entities.Components((BenchInfo != null) ? BenchInfo.TestBenchId : 1,
|
|
(BenchInfo != null) ? BenchInfo.TestBenchName : "testbench",
|
|
inPath.Pump != null ? inPath.Pump.Name : string.Empty,
|
|
outPath.FlowMeter != null ? outPath.FlowMeter.Name : string.Empty,
|
|
outPath.Scale != null ? outPath.Scale.Name : string.Empty,
|
|
outPath.RegulValve != null ? outPath.RegulValve.Name : string.Empty,
|
|
outPath.Diverter != null ? outPath.Diverter.Name : string.Empty));
|
|
|
|
/// Update water meter error flags
|
|
if (ErrorFlagsComp != null)
|
|
{
|
|
for (int i = 0; i < BatchRslts.WMPositionsCount; i++)
|
|
{
|
|
if (BatchRslts.Batch.WaterMeters[i] != null && !BatchRslts.Batch.WaterMeters[i].Disabled)
|
|
{
|
|
long wmInfoFlags;
|
|
BatchRslts.Batch.WaterMeters[i].ErrorFlags = ErrorFlagsComp.GetWMtrErrorFlags(BatchRslts.Batch.WaterMeters[i].MeterTestRslts, out wmInfoFlags);
|
|
BatchRslts.Batch.WaterMeters[i].InfoFlags = wmInfoFlags;
|
|
}
|
|
}
|
|
}
|
|
|
|
/// Update results
|
|
Bridge.OnTestCompleted(this, new TestCompletedEventArgs(testName, tstRslt));
|
|
}
|
|
/// Add data - end
|
|
}
|
|
|
|
|
|
/// Update modeless dialog error information
|
|
Bridge.OnPulsesTestInProgress(this, new PulsesTestInProgressEventArgs(testName, (double)testParams.MinPulsesCount));
|
|
|
|
/// Close the modeless form
|
|
if ((modelessDlg is GenericDevices.IHasCompleted) && !(modelessDlg as GenericDevices.IHasCompleted).Completed)
|
|
{
|
|
UiBridge.Bridge.OnCloseModelessForm(this, null); /// Close the modeless dialog
|
|
}
|
|
modelessDlg = null; /// Modeless dialog is closed now
|
|
|
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.TransitionAfter));
|
|
|
|
/// Append the results to the CSV-file
|
|
allResults.Info(TestResult2CsvLine(testName, test.Part));
|
|
|
|
if (stopCycle) retVal = Event.ErrorFlagsStop;
|
|
|
|
stopTest:
|
|
|
|
/// Close the modeless form
|
|
if ((modelessDlg is GenericDevices.IHasCompleted) && !(modelessDlg as GenericDevices.IHasCompleted).Completed)
|
|
{
|
|
UiBridge.Bridge.OnCloseModelessForm(this, null); /// Close the modeless dialog
|
|
}
|
|
modelessDlg = null; /// Modeless dialog is closed now
|
|
|
|
///
|
|
/// Quit this sequence
|
|
///
|
|
if (isLastRepetition || retVal == Event.UiCmdStop || retVal == Event.OpArgumentError
|
|
|| retVal == Event.RecoverableError || retVal == Event.ErrorFlagsStop
|
|
|| retVal == Event.Error || retVal == Event.ConfigurationError)
|
|
{
|
|
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
|
.AddOperation(checkUiOp)
|
|
.AddOperation(cBrd.StopPreviousOp())
|
|
.EnterState();
|
|
do {
|
|
e = StateMachine.WaitRunDevsRunOps();
|
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; break; }
|
|
}
|
|
while (!e.Contains(Event.PreviousStopped));
|
|
}
|
|
|
|
return new List<Event> { retVal };
|
|
}
|
|
}
|
|
}
|