tbf/TestBenchFramework/BenchControl/MettlerToledo/Multi/ReadMassesOp.cs
2015-05-07 18:03:41 +02:00

64 lines
1.7 KiB
C#

///
/// Copyright (c) 2013-2015 Sensus Metering Systems
///
using System;
using log4net;
namespace TBF.BenchControl.MettlerToledo.Multi
{
public class ReadMassesOp : IOperation
{
private static readonly ILog log = LogManager.GetLogger(typeof(ReadMassesOp));
public override string ToString() { return string.Format("ReadMassesOp()"); }
bool done;
/// <summary>
/// Events: BalanceDone, Error
/// </summary>
/// <param name="balanceDev">Balance device instance</param>
/// <param name="requiredReadingsCount">Required mass readings count (>= 3)</param>
/// <param name="result">Reference to the measured mass in kg</param>
public ReadMassesOp()
{
log.Debug(this.ToString());
}
/// <summary>Start this operation</summary>
public void Start()
{
done = false;
for (int i = 0; i < BalanceDev.BalancesCount; i++)
{
BalanceDev.Balances[i].GetImmediateMassMeasurement();
}
}
/// <summary>Run this operation</summary>
/// <returns>
/// Event.None
/// Event.BalanceDone
/// Event.Error . . . . . Current.Tick == null
/// </returns>
public Event Run()
{
if (done) return Event.BalanceDone; /// Mass has already been read
for (int i = 0; i < BalanceDev.BalancesCount; i++)
{
if (BalanceDev.Balances[i].MsrmntState == MsrmntState.Busy)
{
return Event.None;
}
}
done = true;
return Event.BalanceDone;
}
/// <summary>Stop this operation</summary>
public void Stop()
{
}
}
}