CoverTest
|
RequiredGroupMembership: Users.Grp.GID --> Users.Grp.GID[] (initial version), ver. 2.18.1006
|
2018-09-25 09:05:51 +02:00 |
|
Diverter
|
(1) Diverter switch time measurement modifications (2) const int CountWhenSendingRdDivCmd = 1, CountWhenReadingDiv = 3.
|
2019-09-04 15:08:36 +02:00 |
|
FixedStartRegisterReader
|
IParamsProvider.UpdateParam(...) returns CfgUpdateFlags now.
|
2018-06-18 16:45:32 +02:00 |
|
FlowMeter
|
FlowMeter, FlowmeterTriplet : Condiiton (flow < 0.1 * NominalFlow) removed from LtrPerPulseCorrected( )
|
2019-09-26 15:39:19 +02:00 |
|
FlowMeterDewa
|
Bug fixes : (1) FlowMeterDewa, (2) ControlComWrap.ReferenceFreqs(int i)
|
2019-10-30 09:24:48 +01:00 |
|
FlowMeterTriplet
|
FlowMeter, FlowmeterTriplet : Condiiton (flow < 0.1 * NominalFlow) removed from LtrPerPulseCorrected( )
|
2019-09-26 15:39:19 +02:00 |
|
FlowMeterTwins
|
Refactorization: TBF.UI namespace, no change of function, ver. 2.18.1314
|
2019-09-17 10:58:44 +02:00 |
|
PressureMeter
|
(1) MetrologyDlg displays corrections for all pressure meters, (2) Elde.PressureMeter and Modbus.PressureMeter.Meret use corrections.
|
2019-03-04 09:20:16 +01:00 |
|
PressureMeterInternal
|
Refactorization: TBF.UI namespace, no change of function, ver. 2.18.1314
|
2019-09-17 10:58:44 +02:00 |
|
Pump
|
public enum CfgUpdateFlags moved to Config.Enums
|
2018-06-18 14:44:52 +02:00 |
|
PumpTandem
|
public enum CfgUpdateFlags moved to Config.Enums
|
2018-06-18 14:44:52 +02:00 |
|
PumpWithFM
|
public enum CfgUpdateFlags moved to Config.Enums
|
2018-06-18 14:44:52 +02:00 |
|
RegisterReader
|
MID pulses for each meter calculated correctly in all FlyingStart... methods for datastream meters.
|
2018-11-07 08:13:48 +01:00 |
|
RegulValve
|
(1) TBF.BenchControl.Elde.SendCommandArgs class and cbCommandQueue (2) DiverterToTank, DiverterToSink commands modified.
|
2019-10-24 12:57:37 +02:00 |
|
RegulValveCoax
|
(1) TBF.BenchControl.Elde.SendCommandArgs class and cbCommandQueue (2) DiverterToTank, DiverterToSink commands modified.
|
2019-10-24 12:57:37 +02:00 |
|
RegulValveTandem
|
(1) TBF.BenchControl.Elde.SendCommandArgs class and cbCommandQueue (2) DiverterToTank, DiverterToSink commands modified.
|
2019-10-24 12:57:37 +02:00 |
|
TempMeter
|
TempMeter zero-based index range extended to 0..15, ver. 2.18.1164
|
2019-03-13 09:39:10 +01:00 |
|
TempMeterInternal
|
Refactorization: TBF.UI namespace, no change of function, ver. 2.18.1314
|
2019-09-17 10:58:44 +02:00 |
|
TempMeterMeret
|
Handling of error conditions in ProcedureDlg (e.g. when sensors are changed and user changes parameters without reopening), ver. 2.18.1096
|
2018-12-14 11:40:59 +01:00 |
|
Valve
|
public enum CfgUpdateFlags moved to Config.Enums
|
2018-06-18 14:44:52 +02:00 |
|
ValveEx
|
public enum CfgUpdateFlags moved to Config.Enums
|
2018-06-18 14:44:52 +02:00 |
|
Common.cs
|
TURA_IPERL_NEW : (1) Processing symbol implemented, (2) Elde component dated 17.7.2019 added, ver. 2.18.1273
|
2019-07-24 15:48:32 +02:00 |
|
ControlBoardCfg.cs
|
ComponentCfgBase and derived classes : portected XmlSerializer GetSerializer() --> public XmlSerializer GetSerializer().
|
2018-06-18 12:44:37 +02:00 |
|
ControlBoardCfgCtrl.cs
|
public enum CfgUpdateFlags moved to Config.Enums
|
2018-06-18 14:44:52 +02:00 |
|
ControlBoardCfgCtrl.Designer.cs
|
Refactoring : TestBenchFramework --> TBF ver. 2.18.789
|
2018-01-29 09:48:01 +01:00 |
|
ControlBoardCfgCtrl.resx
|
Refactoring : TestBenchFramework --> TBF ver. 2.18.789
|
2018-01-29 09:48:01 +01:00 |
|
ControlBoardDev.cs
|
(1) TBF.BenchControl.Elde.SendCommandArgs class and cbCommandQueue (2) DiverterToTank, DiverterToSink commands modified.
|
2019-10-24 12:57:37 +02:00 |
|
ControlBoardFactory.cs
|
Refactoring : TestBenchFramework --> TBF ver. 2.18.789
|
2018-01-29 09:48:01 +01:00 |
|
ControlComSim.cs
|
(1) TBF.BenchControl.Elde.SendCommandArgs class and cbCommandQueue (2) DiverterToTank, DiverterToSink commands modified.
|
2019-10-24 12:57:37 +02:00 |
|
ControlComWrap.cs
|
Bug fixes : (1) FlowMeterDewa, (2) ControlComWrap.ReferenceFreqs(int i)
|
2019-10-30 09:24:48 +01:00 |
|
ExecuteCommandOp.cs
|
(1) TBF.BenchControl.Elde.SendCommandArgs class and cbCommandQueue (2) DiverterToTank, DiverterToSink commands modified.
|
2019-10-24 12:57:37 +02:00 |
|
IControlCom.cs
|
(1) TBF.BenchControl.Elde.SendCommandArgs class and cbCommandQueue (2) DiverterToTank, DiverterToSink commands modified.
|
2019-10-24 12:57:37 +02:00 |
|
QueryMeasurementEndOp.cs
|
Refactoring : TestBenchFramework --> TBF ver. 2.18.789
|
2018-01-29 09:48:01 +01:00 |
|
ReadDiverterTransitionOp.cs
|
(1) TBF.BenchControl.Elde.SendCommandArgs class and cbCommandQueue (2) DiverterToTank, DiverterToSink commands modified.
|
2019-10-24 12:57:37 +02:00 |
|
ReadFlowOp.cs
|
Refactoring : TestBenchFramework --> TBF ver. 2.18.789
|
2018-01-29 09:48:01 +01:00 |
|
SendCommandArgs.cs
|
(1) TBF.BenchControl.Elde.SendCommandArgs class and cbCommandQueue (2) DiverterToTank, DiverterToSink commands modified.
|
2019-10-24 12:57:37 +02:00 |
|
SetValvesOp.cs
|
(1) Multiple start valves, test methods modified, (2) Component for JuznaAfrika50 (25.04.2018), ver. 2.18.887
|
2018-04-25 12:47:33 +02:00 |
|
StartMeasurementOp.cs
|
(1) TBF.BenchControl.Elde.SendCommandArgs class and cbCommandQueue (2) DiverterToTank, DiverterToSink commands modified.
|
2019-10-24 12:57:37 +02:00 |
|
StopFlowRegulationOp.cs
|
(1) TBF.BenchControl.Elde.SendCommandArgs class and cbCommandQueue (2) DiverterToTank, DiverterToSink commands modified.
|
2019-10-24 12:57:37 +02:00 |
|
StopPreviousOp.cs
|
(1) TBF.BenchControl.Elde.SendCommandArgs class and cbCommandQueue (2) DiverterToTank, DiverterToSink commands modified.
|
2019-10-24 12:57:37 +02:00 |