tbf/TestBenchFramework/BenchControl/MettlerToledo/Standard/GetBalanceSNOp.cs

64 lines
1.7 KiB
C#

///
/// Copyright (c) 2013-2015 Sensus Metering Systems
/// Author: Milan Hanajik
///
using System;
using log4net;
namespace TBF.BenchControl.MettlerToledo.Standard
{
public class GetBalanceSNOp : IOperation
{
private static readonly ILog log = LogManager.GetLogger(typeof(GetBalanceSNOp));
public override string ToString() { return string.Format("GetBalanceSNOp(.,.)"); }
/// Set by the constructor
BalanceNewDev balanceDev;
string serialNumber;
/// <summary>
/// Events: BalanceDone, Error
/// </summary>
/// <param name="balanceDev">Balance device instance</param>
/// <param name="serialNumber">Reference to the serialNumber</param>
public GetBalanceSNOp(BalanceNewDev balanceDev, ref string serialNumber)
{
if (balanceDev == null) throw new ArgumentNullException("balanceDev");
this.balanceDev = balanceDev;
this.serialNumber = serialNumber;
log.Debug(this.ToString());
}
/// <summary>Start this operation</summary>
public void Start()
{
log.DebugFormat("{0} - Start()", balanceDev.Name);
balanceDev.GetSerialNumber();
}
/// <summary>Run this operation</summary>
/// <returns>
/// Event.None
/// Event.BalanceDone
/// </returns>
public Event Run()
{
if (balanceDev.MsrmntState == MsrmntState.Valid)
{
serialNumber = balanceDev.SerialNumber;
return Event.BalanceDone; /// S/N read successful
}
if (balanceDev.MsrmntState == MsrmntState.Failed) return Event.Error; /// S/N read failed
return Event.None; /// No result yet
}
/// <summary>Stop this operation</summary>
public void Stop()
{
log.DebugFormat("{0} - Stop()", balanceDev.Name);
}
}
}