tbf/TestBenchFramework/BenchControl/TestMethods/FixedStartMassCollection/FixedStartMassCollectionSeq.cs
2016-12-16 13:07:54 +01:00

943 lines
51 KiB
C#

///
/// Copyright (c) 2013-2016 Sensus Metering Systems
///
using System;
using System.Collections.Generic;
using System.Text;
using log4net;
using TBF.BenchControl;
using TBF.Boxes;
using TBF.Resources;
using TBF.UiBridge;
namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
{
public class FixedStartMassCollectionSeq : Sequences.SequenceBase
{
private static readonly ILog log = LogManager.GetLogger(typeof(FixedStartMassCollectionSeq));
/// <summary>
/// Flying start mass collection method sequence
/// </summary>
/// <param name="test">Test entity</param>
/// <returns>
/// Event.Done . . . . . . . OK
/// Event.UiCmdStop . . . . Stopped by the user using the on-screen button STOP
/// Event.OpArgumentError . Target flow is out of range
/// Event.Error . . . . . . Unspecified error
/// </returns>
public IList<Event> Execute(Config.Entities.Test test, bool outerLoopMode, int outerLoopCounter,
bool compound,
HeatMeters.TestParams heatMetersTestParams)
{
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
IList<Event> e = new List<Event>(); /// Events from currently running operations
Event retVal = Event.Done;
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
LtrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
/// Notes:
/// float timeHr = volumeLtr / (1000.0f * targetFlow);
/// float timeSec = 3600.0f * timeHr;
/// int refPulses = (int)(timeSec * (2000.0f * targetFlow / pOut.FlowMeter.NominalFlow));
int totalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f);
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, heatMetersTestParams != null);
float[] wmBeginStates = new float[Config.Data.WMsCount];
float[] wmEndStates = new float[Config.Data.WMsCount];
int repetitionNr = outerLoopMode ? outerLoopCounter : 1; /// First test: repetitionNr=1
//====================================
// Transition or SetRoute - Start
//====================================
switch (Transition(transitionBefore, TransitionContext.BeforeTest))
{
case Event.Error: { retVal = Event.Error; goto stopTest; }
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
}
//====================================
loop:
/// Start the test, initialize test results
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, totalPulses));
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
TestStartTime = DateTime.Now;
TestProgressEventArgs.SetEstimatedTimes(new int[] { 1, 1, 1, 30, Convert.ToInt32(test.TstTime) + 15, 0, 0 });
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.JustStarted));
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
int flowSetTime0 = StateMachine.Time;
///
/// Optionally display prompt to emerge temperature meters to appropriate baths for heat meters test
///
IOperation heatMetersPromptOp = null;
if (heatMetersTestParams != null && !string.IsNullOrEmpty(heatMetersTestParams.Prompt))
{
heatMetersPromptOp = new Operations.MessageBoxOp(heatMetersTestParams.Prompt);
}
//------------------------------------------------
Bridge.OnActivity(this, Strings.Starting_the_pump);
//------------------------------------------------
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
State.Create("FixedStartMassCollection : Waiting before starting the pump")
.AddOperation(checkUiOp)
.AddOperation(new Operations.TimerOp(5))
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.TimerExpired));
///
State.Create("FixedStartMassCollection : Starting the pump")
.AddOperation(checkUiOp)
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
.AddOperation(heatMetersPromptOp)
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
}
while (e.Contains(Event.ValvesBusy) || !e.Contains(Event.AllPositionsReached));
if (!test.Emptying) /// If condition met => skip measuring and force emptying
{
///
/// Measure the weight and skip emptying if there is enough room in the tank
///
State.Create("FixedStartMassCollection : Measuring the mass of water in the tank")
.AddOperation(checkUiOp)
.AddOperation(outPath.Balance.ReadMassOp(ref Mass))
.AddOperation(heatMetersPromptOp)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.BalanceDone));
double estimatedEndMass = Mass.Val + test.Volume;
if (estimatedEndMass < outPath.Balance.Capacity * Constants.TankFullFactor)
{
goto set_flow; /// Enough room in the tank -> skip emptying
}
}
///
/// Empty the water tank
///
switch (EmptyTheTank(outPath.EmptyTankValve, outPath.Balance, heatMetersPromptOp))
{
case Event.Error: { retVal = Event.Error; goto stopTest; }
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
}
set_flow:
//------------------------------------------------
Bridge.OnActivity(this, Strings.Setting_the_flow);
//------------------------------------------------
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
State.Create("FixedStartMassCollection : Starting the pump")
.AddOperation(checkUiOp)
.AddOperation(cBrd.SetValvesOp(inPath.Pump, null))
.AddOperation(heatMetersPromptOp)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.ValvesSet));
//--------------------------------
State.Create("FixedStartMassCollection : Setting the flow")
.AddOperation(checkUiOp)
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, 600)) /// timeout = 10 min.
.AddOperation(heatMetersPromptOp)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
if (e.Contains(Event.OpArgumentError)) { retVal = Event.OpArgumentError; goto stopTest; }
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
if (e.Contains(Event.RegulValveTimeOut))
{
Bridge.OnError(this, Strings.Timeout);
retVal = Event.Done;
goto stopTest;
}
if (e.Contains(Event.Next)) goto flow_set;
}
while (!e.Contains(Event.FlowReached));
flow_set:
int flowSetTime = StateMachine.Time - flowSetTime0;
if (heatMetersTestParams != null && heatMetersPath != null)
{
//---------------------------------------------------
Bridge.OnActivity(this, Strings.Setting_temperature);
//---------------------------------------------------
int lastTimeSec = StateMachine.Time;
double Tw_last = 0;
double Tc_last = 0;
State.Create("FixedStartMassCollection : Check temperature stabilized.")
.AddOperation(checkUiOp)
.AddOperation(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
.AddOperation(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
.AddOperation(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
.AddOperation(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
.AddOperation(heatMetersPromptOp)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
if (e.Contains(Event.Next)) goto temperature_set;
if (TempRefHi1.Val != 0 && TempRefHi2.Val != 0 && TempRefLo1.Val != 0 && TempRefLo2.Val != 0)
{
if (StateMachine.Time - lastTimeSec > 10 || StateMachine.Time - lastTimeSec < 0)
{
double Tw = (TempRefHi1.Val + TempRefHi2.Val) / 2;
double Tc = (TempRefLo1.Val + TempRefLo2.Val) / 2;
if (heatMetersTestParams.TempWarmLo <= Tw && Tw <= heatMetersTestParams.TempWarmHi &&
heatMetersTestParams.TempColdLo <= Tc && Tc <= heatMetersTestParams.TempColdHi &&
Math.Abs(Tw - Tw_last) <= heatMetersTestParams.ChangeInTimeWarm &&
Math.Abs(Tc - Tc_last) <= heatMetersTestParams.ChangeInTimeCold &&
Math.Abs(TempRefHi1.Val - TempRefHi2.Val) <= heatMetersTestParams.DeltaTempWarm &&
Math.Abs(TempRefLo1.Val - TempRefLo2.Val) <= heatMetersTestParams.DeltaTempCold)
{
goto temperature_set;
}
lastTimeSec = StateMachine.Time;
Tw_last = Tw;
Tc_last = Tc;
}
}
}
while (true);
}
temperature_set:
//------------------------------------------------
Bridge.OnActivity(this, Strings.Stopping_flow_for_the_fixed_start);
//------------------------------------------------
State.Create("FixedStartMassCollection : Closing the start/stop valve before the fixed start test")
.AddOperation(checkUiOp)
.AddOperation(StateMachine.ControlBoard.SetValvesOp(null, outPath.StartValve))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
}
while (!e.Contains(Event.ValvesSet));
int time = StateMachine.Time;
double currentFlow = RefFlow.Val;
/// Extract cameras from the current sensors path, add operations to the detection state
IList<IOperation> measureOperations = new List<IOperation>();
for (int i = 0; i < sensPath.RegisterReaders.Length; i++)
{
GenericDevices.ICameraRoi cameraRoi = sensPath.RegisterReaders[i] as GenericDevices.ICameraRoi;
if (cameraRoi != null) measureOperations.Add(cameraRoi.MeasureOp());
}
///
/// Enter watermeter begin states here
///
GenericDevices.IHasWMStatesForm dataEntryCmpnt =
TbfComponents.FindComponent(StateMachine.Procedure.DataEntry) as GenericDevices.IHasWMStatesForm;
if (dataEntryCmpnt != null)
{
Bridge.OnActivity(this, Strings.Enter_water_meter_data);
State.Create("FixedStartMassCollection : Enter begin-state")
.AddOperation((dataEntryCmpnt as GenericDevices.IHasWMStatesForm).ShowTestStartFormOp())
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
.AddOperation(checkUiOp)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.ModelessFormClosed));
if (heatMetersTestParams != null)
{
for (int i = 0; i < Config.Data.HeatMetersCount; i++)
{
BenchControl.Elde.FixedStartRegisterReader.RegisterReader volumeRegisterReader =
sensPath.RegisterReaders[2 * i] as BenchControl.Elde.FixedStartRegisterReader.RegisterReader;
BenchControl.Elde.FixedStartRegisterReader.RegisterReader energyRegisterReader =
sensPath.RegisterReaders[2 * i + 1] as BenchControl.Elde.FixedStartRegisterReader.RegisterReader;
if (volumeRegisterReader != null) volumeRegisterReader.BeginWMState = dataEntryCmpnt.WMStartState(i);
if (energyRegisterReader != null && dataEntryCmpnt is GenericDevices.IHasHeatMtrStatesForm)
{
energyRegisterReader.BeginWMState = (float)(dataEntryCmpnt as GenericDevices.IHasHeatMtrStatesForm).EnergyStartState(i);
}
}
}
else
{
for (int i = 0; i < Config.Data.WMsCount; i++)
{
BenchControl.Elde.FixedStartRegisterReader.RegisterReader registerReader =
sensPath.RegisterReaders[i] as BenchControl.Elde.FixedStartRegisterReader.RegisterReader;
if (registerReader != null) registerReader.BeginWMState = dataEntryCmpnt.WMStartState(i);
}
}
}
//------------------------------------------------
Bridge.OnActivity(this, Strings.Measuring_the_weight);
//------------------------------------------------
State.Create("FixedStartMassCollection : Measuring the start mass")
.AddOperation(checkUiOp)
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
.AddOperation(outPath.TempDiv.ReadTempOp(ref TempDiv))
.AddOperation(benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
.AddOperation(benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
.AddOperation((StateMachine.Ambient != null)
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
.AddOperations(measureOperations)
.AddOperation(outPath.Balance.ReadStableMassOp(ref StartMass, test.MassRepeats, test.MassSpread, test.MassMethod))
.AddOperation(cBrd.UpdateTankWeightOp())
.AddOperation(processDataLoggingOp)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.BalanceDone));
Mass.Val = StartMass.Val;
//------------------------------------------------
Bridge.OnActivity(this, Strings.Test_in_progress);
//------------------------------------------------
State.Create("FixedStartMassCollection : Starting the test")
.AddOperation(checkUiOp)
.AddOperations(measureOperations)
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Diverter | Elde.TestMethods.Synchro,
test.Qfrom, test.Qto, 2 * totalPulses, (float)test.TolerRed))
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.MeasurementStarted));
State.Create("FixedStartMassCollection : Opening the start/stop valve at the beginning of the fixed start test")
.AddOperation(checkUiOp)
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
.AddOperation(StateMachine.ControlBoard.SetValvesOp(outPath.StartValve, null))
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
}
while (!e.Contains(Event.ValvesSet));
/// Measurement loop - preparation
readRegistersOp = new Operations.ReadMoreRegistersOp(sensPath.RegisterReaders);
queryEnd1 = cBrd.QueryMeasurementEndOp();
queryEnd2 = cBrd.QueryMeasurementEndOp();
ClearAllStatistics();
int estimtdEndTime = StateMachine.Time + (int)test.TstTime;
/// Measurement loop - begin
do
{
//--------------------------------
switch (ReadRegistersTempPressAmbient(measureOperations, true))
{
case Event.Error:
retVal = Event.Error;
goto stopTest;
case Event.UiCmdStop:
retVal = Event.UiCmdStop;
goto stopTest;
case Event.MeasurementCompleted:
goto test_completed;
}
int remainingTime = Math.Max(estimtdEndTime - StateMachine.Time, 0);
if (remainingTime > 60)
{
Bridge.OnActivity(this, string.Format("{0} ... {1} {2} {3} {4}", Strings.Test_in_progress, remainingTime / 60, "min", remainingTime % 60, Strings.sec));
}
else
{
Bridge.OnActivity(this, string.Format("{0} ... {1} s", Strings.Test_in_progress, remainingTime));
}
RefFreq.Val = cBrd.ReferenceFreq;
RefFlow.Val = cBrd.ReferenceFlow;
UpdateAllStatistics();
if (heatMetersTestParams != null)
{
if (lastEnergyUpdateTime == 0)
{
lastEnergyUpdateTime = StateMachine.Time;
}
else
{
//double deltaTime = (double)(StateMachine.Time - lastEnergyUpdateTime);
double T_in = (TempRefHi1.Val + TempRefHi2.Val) / 2; /// [°C]
double T_out = (TempRefLo1.Val + TempRefLo2.Val) / 2; /// [°C]
double deltaVolume = LtrPerRefPulse * RefPulsesDelta; /// [l]
double deltaEnergy = (0.001 * deltaVolume) * (T_in - T_out) * Formulas.HeatCoefficientWater(16, T_in, T_out, heatMetersTestParams.FlowMeasuredAtHiTempPipe); /// [J] = [m3] * [K] * [J/(m3 K)]
Energy.Update(deltaEnergy);
VolumeForEnergy.Update(deltaVolume);
lastEnergyUpdateTime = StateMachine.Time;
}
}
if (compound)
{
/// TODO: Reimplement for combined meters
//for (int i = 0; i < Config.Data.CompoundWMsCount; i++)
//{
// data.TestResult.CombinedMeters[i].VolumeMeter = data.TestResult.Meters[2 * i].VolumeMeter
// + data.TestResult.Meters[2 * i + 1].VolumeMeter;
// if (data.Volume.Valid)
// {
// data.TestResult.CombinedMeters[i].VolumeErrorPct =
// Formulas.ErrorFromVolumes(data.TestResult.CombinedMeters[i].VolumeMeter, data.Volume.Val);
// }
//}
}
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
}
while (cBrd.EtPulses(0) < totalPulses);
/// Measurement loop - end
test_completed:
State.Create("FixedStartMassCollection : Closing the start/stop valve at the end of the fixed start test")
.AddOperation(checkUiOp)
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
.AddOperation(StateMachine.ControlBoard.SetValvesOp(null, outPath.StartValve))
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
}
while (e.Contains(Event.ValvesBusy));
State.Create("FixedStartMassCollection : Waiting before 2nd mass measurement")
.AddOperation(checkUiOp)
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
.AddOperation(outPath.TempDiv.ReadTempOp(ref TempDiv))
.AddOperation(benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
.AddOperation(benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
.AddOperation((StateMachine.Ambient != null)
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
.AddOperation(outPath.Balance.ReadMassOp(ref Mass))
.AddOperation(cBrd.UpdateTankWeightOp())
.AddOperation(processDataLoggingOp)
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.TimerExpired));
//------------------------------------------------
Bridge.OnActivity(this, Strings.Measuring_the_weight);
//------------------------------------------------
State.Create("FixedStartMassCollection : Measuring the end mass")
.AddOperation(checkUiOp)
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
.AddOperation(outPath.TempDiv.ReadTempOp(ref TempDiv))
.AddOperation(benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
.AddOperation(benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
.AddOperation((StateMachine.Ambient != null)
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
.AddOperation(outPath.Balance.ReadStableMassOp(ref EndMass, test.MassRepeats, test.MassSpread, test.MassMethod))
.AddOperation(cBrd.UpdateTankWeightOp())
.AddOperation(processDataLoggingOp)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.BalanceDone));
///
TestEndTime = DateTime.Now;
State.Create("FixedStartMassCollection : Stopping diverter, gate, etc.")
.AddOperation(checkUiOp)
.AddOperation(cBrd.StopPreviousOp())
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.PreviousStopped));
double massStart = Formulas.CorrectedValue(StartMass.Val, outPath.Balance.Corrections);
double massEnd = Formulas.CorrectedValue(EndMass.Val, outPath.Balance.Corrections);
double densityOut = Formulas.WaterDensityFromTemp(TempDownStat.Average); /// [kg/m3]
double volumeCTV = 1001.03 * (massEnd - massStart) / densityOut;
double refEnergy = Energy.Sum * volumeCTV / VolumeForEnergy.Sum; /// [J]=[J]*[l]/[l]
///
/// Enter watermeter end states here
///
if (dataEntryCmpnt != null)
{
Bridge.OnActivity(this, Strings.Enter_water_meter_data);
State state = State.Create("FixedStartMassCollection : Enter end-state");
if (heatMetersTestParams != null && dataEntryCmpnt is GenericDevices.IHasHeatMtrStatesForm)
{
state.AddOperation((dataEntryCmpnt as GenericDevices.IHasHeatMtrStatesForm).
ShowTestEndFormOp(volumeCTV, test.ErrLimLo + test.Uncertainty, test.ErrLimHi - test.Uncertainty,
refEnergy, test.ErrLimLo + test.Uncertainty, test.ErrLimHi - test.Uncertainty));
}
else
{
state.AddOperation(dataEntryCmpnt.ShowTestEndFormOp(volumeCTV, test.ErrLimLo + test.Uncertainty,
test.ErrLimHi - test.Uncertainty));
}
state.AddOperation(checkUiOp);
state.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.ModelessFormClosed));
if (heatMetersTestParams != null)
{
for (int i = 0; i < Config.Data.HeatMetersCount; i++)
{
BenchControl.Elde.FixedStartRegisterReader.RegisterReader volumeRegisterReader =
sensPath.RegisterReaders[2 * i] as BenchControl.Elde.FixedStartRegisterReader.RegisterReader;
BenchControl.Elde.FixedStartRegisterReader.RegisterReader energyRegisterReader =
sensPath.RegisterReaders[2 * i + 1] as BenchControl.Elde.FixedStartRegisterReader.RegisterReader;
if (volumeRegisterReader != null) volumeRegisterReader.EndWMState = dataEntryCmpnt.WMEndState(i);
if (energyRegisterReader != null && dataEntryCmpnt is GenericDevices.IHasHeatMtrStatesForm)
{
energyRegisterReader.EndWMState = (float)(dataEntryCmpnt as GenericDevices.IHasHeatMtrStatesForm).EnergyEndState(i);
}
}
}
else
{
for (int i = 0; i < Config.Data.WMsCount; i++)
{
BenchControl.Elde.FixedStartRegisterReader.RegisterReader registerReader =
sensPath.RegisterReaders[i] as BenchControl.Elde.FixedStartRegisterReader.RegisterReader;
if (registerReader != null) registerReader.EndWMState = dataEntryCmpnt.WMEndState(i);
}
}
}
//------------------------------------------------
Bridge.OnActivity(this, Strings.Test_completed);
//------------------------------------------------
/// Make sure the CycleBeginForm is closed so that water meter data (s/n) can be copied into results
if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stopTest;
///
/// Populate TestResult data entity with data
///
Results.Entities.TestRslt tstRslt = BatchRslts.GetTestRslt(testName, test.Part);
if (tstRslt != null)
{
/// Auxiliary results
tstRslt.AmbTempMean = (float)AmbTempStat.Average;
tstRslt.AmbTempStart = (float)AmbTempStat.First;
tstRslt.AmbTempEnd = (float)AmbTempStat.Last;
tstRslt.AmbTempMin = (float)AmbTempStat.Min;
tstRslt.AmbTempMax = (float)AmbTempStat.Max;
tstRslt.AmbPressMean = (float)AmbPressStat.Average;
tstRslt.AmbPressStart = (float)AmbPressStat.First;
tstRslt.AmbPressEnd = (float)AmbPressStat.Last;
tstRslt.AmbPressMin = (float)AmbPressStat.Min;
tstRslt.AmbPressMax = (float)AmbPressStat.Max;
tstRslt.AmbHumiMean = (float)AmbHumiStat.Average;
tstRslt.AmbHumiStart = (float)AmbHumiStat.First;
tstRslt.AmbHumiEnd = (float)AmbHumiStat.Last;
tstRslt.AmbHumiMin = (float)AmbHumiStat.Min;
tstRslt.AmbHumiMax = (float)AmbHumiStat.Max;
tstRslt.PressUpMean = (float)PressUpStat.Average;
tstRslt.PressUpStart = (float)PressUpStat.First;
tstRslt.PressUpEnd = (float)PressUpStat.Last;
tstRslt.PressUpMin = (float)PressUpStat.Min;
tstRslt.PressUpMax = (float)PressUpStat.Max;
tstRslt.PressDownMean = (float)PressDownStat.Average;
tstRslt.PressDownStart = (float)PressDownStat.First;
tstRslt.PressDownEnd = (float)PressDownStat.Last;
tstRslt.PressDownMin = (float)PressDownStat.Min;
tstRslt.PressDownMax = (float)PressDownStat.Max;
tstRslt.PressDeltaMean = (float)PressDeltaStat.Average;
tstRslt.PressDeltaStart = (float)PressDeltaStat.First;
tstRslt.PressDeltaEnd = (float)PressDeltaStat.Last;
tstRslt.PressDeltaMin = (float)PressDeltaStat.Min;
tstRslt.PressDeltaMax = (float)PressDeltaStat.Max;
tstRslt.TempUpMean = (float)TempUpStat.Average;
tstRslt.TempUpStart = (float)TempUpStat.First;
tstRslt.TempUpEnd = (float)TempUpStat.Last;
tstRslt.TempUpMin = (float)TempUpStat.Min;
tstRslt.TempUpMax = (float)TempUpStat.Max;
tstRslt.TempDownMean = (float)TempDownStat.Average;
tstRslt.TempDownStart = (float)TempDownStat.First;
tstRslt.TempDownEnd = (float)TempDownStat.Last;
tstRslt.TempDownMin = (float)TempDownStat.Min;
tstRslt.TempDownMax = (float)TempDownStat.Max;
tstRslt.TempDivMean = (float)TempDivStat.Average;
tstRslt.TempDivStart = (float)TempDivStat.First;
tstRslt.TempDivEnd = (float)TempDivStat.Last;
tstRslt.TempDivMin = (float)TempDivStat.Min;
tstRslt.TempDivMax = (float)TempDivStat.Max;
tstRslt.DensityIn = Formulas.WaterDensityFromTemp(tstRslt.TempUpMean); /// [kg/m3]
tstRslt.DensityOut = Formulas.WaterDensityFromTemp(tstRslt.TempDownMean); /// [kg/m3]
tstRslt.DensityDiv = Formulas.WaterDensityFromTemp(tstRslt.TempDivMean); /// [kg/m3]
/// Main results
tstRslt.StartTime = TestStartTime;
tstRslt.EndTime = TestEndTime;
tstRslt.FlowSetTime = flowSetTime;
tstRslt.TestTime = cBrd.TTime; /// [s] measurement time
tstRslt.PulsesMaster = Convert.ToDouble(cBrd.EtPulses(0)); /// Pulses of the master flow meter (test total)
tstRslt.MassStartRaw = StartMass.Val;
tstRslt.MassStart = massStart;
tstRslt.MassEndRaw = EndMass.Val;
tstRslt.MassEnd = massEnd;
tstRslt.FlowMass = 3600.0 * (tstRslt.MassEnd - tstRslt.MassStart) / tstRslt.TestTime; /// [kg/h]
tstRslt.FlowVolume = 3.6 * LtrPerRefPulse * tstRslt.PulsesMaster / tstRslt.TestTime; /// [m3/h]
tstRslt.VolumeMaster = LtrPerRefPulse * tstRslt.PulsesMaster; /// [l] volume from the master flow meter
tstRslt.VolumeCTV = volumeCTV; /// [l] 1000.0f is because density is in [kg/m3]
tstRslt.ConstMaster = LtrPerRefPulse * tstRslt.VolumeCTV / tstRslt.VolumeMaster; /// Corrected master pulses per liter
tstRslt.ErrorMaster = Formulas.ErrorFromVolumes(tstRslt.VolumeMaster, tstRslt.VolumeCTV);
tstRslt.FlowMin = (float)((tstRslt.VolumeMaster != 0) ? (RefFlowStat.Min * tstRslt.VolumeCTV / tstRslt.VolumeMaster) : RefFlowStat.Min);
tstRslt.FlowMax = (float)((tstRslt.VolumeMaster != 0) ? (RefFlowStat.Max * tstRslt.VolumeCTV / tstRslt.VolumeMaster) : RefFlowStat.Max);
if (compound)
{
///
/// Compound meters
///
for (int i = 0; i < BatchRslts.WMPositionsCount; i++)
{
if (test.Part != 0 && test.Part != Utils.PartNr(i + 1, BatchRslts.Batch.Compound)) continue;
Results.Entities.MeterTestRslt mainMeterRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.CompoundMain);
Results.Entities.MeterTestRslt auxMeterRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.CompoundAux);
for (int isAux = 0; isAux <= 1; isAux++) /// 0=main, 1=aux
{
Results.Entities.MeterTestRslt meterRslt = (isAux == 0) ? mainMeterRslt : auxMeterRslt;
BenchControl.Elde.FixedStartRegisterReader.RegisterReader regReader =
sensPath.RegisterReaders[2 * i + isAux] as BenchControl.Elde.FixedStartRegisterReader.RegisterReader;
if (meterRslt != null && regReader != null)
{
meterRslt.PulsesPerLiter = 1.0f;
meterRslt.VolumeStart = regReader.BeginWMState; /// [l]
meterRslt.VolumeEnd = regReader.EndWMState; /// [l]
meterRslt.VolumeMeter = meterRslt.VolumeEnd - meterRslt.VolumeStart; /// [l]
meterRslt.VolumeRef = tstRslt.VolumeCTV; /// [l]
meterRslt.PulsesMeter = meterRslt.VolumeMeter;
meterRslt.PulsesMaster = tstRslt.PulsesMaster;
meterRslt.TestTime = tstRslt.TestTime;
meterRslt.Error = Formulas.ErrorFromVolumes(meterRslt.VolumeMeter, meterRslt.VolumeRef); /// Not used for evaluation
}
}
Results.Entities.MeterTestRslt compoundMeterRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.Compound);
if (compoundMeterRslt != null && mainMeterRslt != null && auxMeterRslt != null)
{
compoundMeterRslt.VolumeRef = tstRslt.VolumeCTV; /// [l] must be calculated before main & aux. meter error
compoundMeterRslt.VolumeMeter = mainMeterRslt.VolumeMeter + auxMeterRslt.VolumeMeter;
compoundMeterRslt.PulsesMaster = tstRslt.PulsesMaster;
compoundMeterRslt.TestTime = tstRslt.TestTime;
compoundMeterRslt.Error = Formulas.ErrorFromVolumes(compoundMeterRslt.VolumeMeter, compoundMeterRslt.VolumeRef);
compoundMeterRslt.Passed = (compoundMeterRslt.Error >= test.ErrLimLo + test.Uncertainty)
&& (compoundMeterRslt.Error <= test.ErrLimHi - test.Uncertainty);
mainMeterRslt.Passed = auxMeterRslt.Passed = compoundMeterRslt.Passed;
mainMeterRslt.TestDone = auxMeterRslt.TestDone = compoundMeterRslt.TestDone = true;
}
}
}
else if (heatMetersTestParams != null)
{
///
/// Heat meters
///
tstRslt.RefEnergy = Energy.Sum * tstRslt.VolumeCTV / VolumeForEnergy.Sum; /// [J] = [J] * [l] / [l]
tstRslt.Custom1 = (float)TempRefHiStat.Average;
tstRslt.Custom2 = (float)TempRefHiStat.First;
tstRslt.Custom3 = (float)TempRefHiStat.Last;
tstRslt.Custom4 = (float)TempRefHiStat.Min;
tstRslt.Custom5 = (float)TempRefHiStat.Max;
tstRslt.Custom6 = (float)TempRefLoStat.Average;
tstRslt.Custom7 = (float)TempRefLoStat.First;
tstRslt.Custom8 = (float)TempRefLoStat.Last;
tstRslt.Custom9 = (float)TempRefLoStat.Min;
tstRslt.Custom10 = (float)TempRefLoStat.Max;
for (int i = 0; i < BatchRslts.WMPositionsCount; i++)
{
if (test.Part != 0 && test.Part != Utils.PartNr(i + 1, BatchRslts.Batch.Compound)) continue;
Results.Entities.MeterTestRslt volumeRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.HeatMeterVolume);
Results.Entities.MeterTestRslt energyRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.HeatMeterEnergy);
BenchControl.Elde.FixedStartRegisterReader.RegisterReader volumeRegReader =
(sensPath.RegisterReaders.Length > 2 * i) ? sensPath.RegisterReaders[2 * i] as BenchControl.Elde.FixedStartRegisterReader.RegisterReader : null;
BenchControl.Elde.FixedStartRegisterReader.RegisterReader energyRegReader =
(sensPath.RegisterReaders.Length > 2 * i + 1) ? sensPath.RegisterReaders[2 * i + 1] as BenchControl.Elde.FixedStartRegisterReader.RegisterReader : null;
if (volumeRslt != null && volumeRegReader != null)
{
volumeRslt.PulsesPerLiter = 1.0f;
volumeRslt.VolumeStart = volumeRegReader.BeginWMState;
volumeRslt.VolumeEnd = volumeRegReader.EndWMState;
volumeRslt.VolumeMeter = volumeRslt.VolumeEnd - volumeRslt.VolumeStart;
volumeRslt.VolumeRef = tstRslt.VolumeCTV;
volumeRslt.PulsesMeter = volumeRslt.VolumeMeter;
volumeRslt.PulsesMaster = tstRslt.PulsesMaster; /// <----------------- ???
volumeRslt.TestTime = tstRslt.TestTime;
volumeRslt.Error = Formulas.ErrorFromVolumes(volumeRslt.VolumeMeter, volumeRslt.VolumeRef);
volumeRslt.Passed = !heatMetersTestParams.EvaluateVolume ||
((volumeRslt.Error >= test.ErrLimLo + test.Uncertainty) &&
(volumeRslt.Error <= test.ErrLimHi - test.Uncertainty));
volumeRslt.TestDone = true;
}
if (energyRslt != null && energyRegReader != null && dataEntryCmpnt is GenericDevices.IHasHeatMtrStatesForm)
{
volumeRslt.PulsesPerLiter = 1.0f;
energyRslt.VolumeStart = (dataEntryCmpnt as GenericDevices.IHasHeatMtrStatesForm).EnergyStartState(i);
energyRslt.VolumeEnd = (dataEntryCmpnt as GenericDevices.IHasHeatMtrStatesForm).EnergyEndState(i);
energyRslt.VolumeMeter = energyRslt.VolumeEnd - energyRslt.VolumeStart;
energyRslt.VolumeRef = tstRslt.RefEnergy;
energyRslt.PulsesMeter = energyRslt.VolumeMeter;
energyRslt.PulsesMaster = tstRslt.PulsesMaster; /// <----------------- ???
energyRslt.Error = Formulas.ErrorFromVolumes(energyRslt.VolumeMeter, energyRslt.VolumeRef);
energyRslt.Passed = (energyRslt.Error >= heatMetersTestParams.ErrorLimitLo)
&& (energyRslt.Error <= heatMetersTestParams.ErrorLimitHi);
energyRslt.TestDone = true;
}
}
}
else
{
///
/// Single meters
///
for (int i = 0; i < BatchRslts.WMPositionsCount; i++)
{
if (test.Part != 0 && test.Part != Utils.PartNr(i + 1, BatchRslts.Batch.Compound)) continue;
Results.Entities.MeterTestRslt meterRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.Single);
BenchControl.Elde.FixedStartRegisterReader.RegisterReader regReader =
sensPath.RegisterReaders[i] as BenchControl.Elde.FixedStartRegisterReader.RegisterReader;
if (meterRslt != null && regReader != null)
{
meterRslt.PulsesPerLiter = 1.0f;
meterRslt.VolumeStart = regReader.BeginWMState;
meterRslt.VolumeEnd = regReader.EndWMState;
meterRslt.VolumeMeter = meterRslt.VolumeEnd - meterRslt.VolumeStart;
meterRslt.VolumeRef = tstRslt.VolumeCTV; /// liter
meterRslt.PulsesMeter = meterRslt.VolumeMeter;
meterRslt.PulsesMaster = tstRslt.PulsesMaster;
meterRslt.TestTime = tstRslt.TestTime;
meterRslt.Error = Formulas.ErrorFromVolumes(meterRslt.VolumeMeter, meterRslt.VolumeRef);
meterRslt.Passed = (meterRslt.Error >= test.ErrLimLo + test.Uncertainty)
&& (meterRslt.Error <= test.ErrLimHi - test.Uncertainty);
meterRslt.TestDone = true;
}
}
}
tstRslt.Components = Results.Entities.Components
.UpdateList(BatchRslts.ComponentsList,
new Results.Entities.Components((BenchInfo != null) ? BenchInfo.TestBenchId : 1,
(BenchInfo != null) ? BenchInfo.TestBenchName : "testbench",
inPath.Pump != null ? inPath.Pump.Name : string.Empty,
outPath.FlowMeter != null ? outPath.FlowMeter.Name : string.Empty,
outPath.Balance != null ? outPath.Balance.Name : string.Empty,
outPath.RegulValve != null ? outPath.RegulValve.Name : string.Empty,
outPath.Diverter != null ? outPath.Diverter.Name : string.Empty));
/// Update results
Bridge.OnTestCompleted(this, new TestCompletedEventArgs(testName, tstRslt));
}
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.TransitionAfter));
/// Append the results to the CSV-file
allResults.Info(TestResult2CsvLine(testName, test.Part));
if (!outerLoopMode && (++repetitionNr <= test.Repeats))
{
goto loop;
}
stopTest:
///----------------------///
/// Quit this sequence ///
///----------------------///
State.Create("FixedStartMassCollection : Stopping diverter, gate, etc.")
.AddOperation(checkUiOp)
.AddOperation(cBrd.StopPreviousOp())
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.PreviousStopped));
/// Transition sequence at the end of test
/// Prevent overwriting 'retVal' in case it was set to non-default value earlier
switch (Transition(transitionAfter, (retVal == Event.Done) ? TransitionContext.AfterTest : TransitionContext.Stop))
{
case Event.Error: { if (retVal == Event.Done) retVal = Event.Error; break; }
case Event.UiCmdStop: { if (retVal == Event.Done) retVal = Event.UiCmdStop; break; }
}
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Completed));
/// Create a list with one item 'retVal' (default is Event.Done) and return it
IList<Event> retList = new List<Event>(1);
retList.Add(retVal);