/// Copyright (c) 2019-2023 Sensus Slovensko a.s.
|
|
///
|
|
using System;
|
|
using System.Collections.Generic;
|
|
using System.Windows.Forms;
|
|
using NHibernate;
|
|
using log4net;
|
|
using Common;
|
|
using Config.Entities;
|
|
using TBF.Rig;
|
|
using TBF.Resources;
|
|
using TBF.UI.Shared;
|
|
|
|
namespace TBF.UI.Bench.Uncertainties
|
|
{
|
|
public partial class UncertaintiesDlg : Form, IParentOfListViewEx
|
|
{
|
|
static readonly ILog log = LogManager.GetLogger(typeof(UncertaintiesDlg));
|
|
|
|
public ISession Session;
|
|
public IList<Component> cmpntEntities;
|
|
|
|
public UncertaintiesDlg()
|
|
{
|
|
InitializeComponent();
|
|
|
|
/// Open a database session
|
|
try { Session = TBF.DB.ConfigDBSessionFactory.OpenSession(); }
|
|
catch (Exception e)
|
|
{
|
|
MessageBox.Show(Strings.Cannot_connect_to_the_database + Environment.NewLine + e.Message,
|
|
Strings.Error, MessageBoxButtons.OK, MessageBoxIcon.Exclamation);
|
|
}
|
|
|
|
/// SharedDlgButtons configuration
|
|
sharedButtons.ParentForm = this;
|
|
#if LANG_PL
|
|
sharedButtons.RequiredGroupMembership = new GID[] { GID.MetrologicalAuthority };
|
|
#else
|
|
sharedButtons.RequiredGroupMembership = new GID[] { GID.Metrologists, GID.MetrologicalAuthority };
|
|
#endif
|
|
sharedButtons.OptionalButtons = SharedButtons.Buttons.Add | SharedButtons.Buttons.Remove;
|
|
sharedButtons.Unlocked += unlockButton_Click;
|
|
sharedButtons.OKClicked += okButton_Click;
|
|
sharedButtons.CancelClicked += cancelButton_Click;
|
|
sharedButtons.AddClicked += addButton_Click;
|
|
sharedButtons.RemoveClicked += removeButton_Click;
|
|
}
|
|
|
|
private void UncertaintiesDlg_Load(object sender, EventArgs e)
|
|
{
|
|
LoadUISettings();
|
|
|
|
Text = Strings.Uncertainty;
|
|
|
|
int fixedCount = 0;
|
|
int balancesCount = 0;
|
|
int levelMetersCount = 0;
|
|
int divertersCount = 0;
|
|
int flowMetersCount = 0;
|
|
int pressMetersCount = 0;
|
|
int tempMetersCount = 0;
|
|
int evaporationsCount = 0;
|
|
|
|
cmpntEntities = (Session == null) ? new List<Component>() : Session.QueryOver<Component>()
|
|
.OrderBy(x => x. ItemNr).Asc
|
|
.List();
|
|
foreach (var cmpnt in cmpntEntities)
|
|
{
|
|
Rig.Generic.IComponentFactory factory = TbfComponents.CmpntFactoryFromClassName(cmpnt.ClassName);
|
|
|
|
/// Tab-page density
|
|
if (factory is Rig.DataContainers.Density.ComponentFactory)
|
|
{
|
|
fixedCount++;
|
|
TabPage tabPage = new TabPage(" " + Strings.Density + " ");
|
|
UncertntDlgDensityTab uiControl = new UncertntDlgDensityTab();
|
|
uiControl.MeterEntity = cmpnt;
|
|
uiControl.DensityCfg = factory.CmpntCfgFromCmpntEntity(cmpnt) as Rig.DataContainers.Density.ComponentCfg;
|
|
uiControl.Dock = DockStyle.Fill;
|
|
tabPage.Tag = uiControl;
|
|
tabPage.Controls.Add(uiControl);
|
|
uncertaintiesTabControl.TabPages.Add(tabPage);
|
|
}
|
|
|
|
/// Tab-pages for scales
|
|
if (factory is Rig.MettlerToledo.Standard.BalanceFactory ||
|
|
factory is Rig.MettlerToledo.Standard.BalanceOldFactory ||
|
|
factory is Rig.MettlerToledo.Standard.BalanceNewFactory ||
|
|
factory is Rig.MettlerToledo.Multi.BalanceFactory)
|
|
{
|
|
balancesCount++;
|
|
TabPage tabPage = new TabPage(" " + cmpnt.Name + " ");
|
|
UncertntDlgScaleTab uiControl = new UncertntDlgScaleTab();
|
|
uiControl.MeterEntity = cmpnt;
|
|
uiControl.ScaleCfg = factory.CmpntCfgFromCmpntEntity(cmpnt) as Rig.GenericDevices.IScaleCfg;
|
|
uiControl.Dock = DockStyle.Fill;
|
|
tabPage.Tag = uiControl;
|
|
tabPage.Controls.Add(uiControl);
|
|
uncertaintiesTabControl.TabPages.Add(tabPage);
|
|
}
|
|
|
|
///// Tab-pages for flowmeters
|
|
//if (factory is Rig.Elde.FlowMeter.FlowMeterFactory)
|
|
//{
|
|
// Rig.Elde.FlowMeter.FlowMeterCfg flowMeterCfg = factory.CmpntCfgFromCmpntEntity(cmpnt) as Rig.Elde.FlowMeter.FlowMeterCfg;
|
|
|
|
// for (int r = 0; r <= 5; r++)
|
|
// {
|
|
// if (flowMeterCfg.RangeEnabled(r))
|
|
// {
|
|
// flowMetersCount++;
|
|
// TabPage tabPage = new TabPage(string.Format(((r == 0) ? " {0} " : " {0} r{1} "), cmpnt.Name, r));
|
|
// MetrologyDlgFlowMeterTab uiControl = new MetrologyDlgFlowMeterTab(r);
|
|
// uiControl.MeterEntity = cmpnt;
|
|
// uiControl.CalibInfoCfg = factory.CmpntCfgFromCmpntEntity(cmpnt) as Rig.GenericDevices.ICalibRangesCfg;
|
|
// uiControl.Dock = DockStyle.Fill;
|
|
// tabPage.Tag = uiControl;
|
|
// tabPage.Controls.Add(uiControl);
|
|
// metrologyTabControl.TabPages.Add(tabPage);
|
|
// }
|
|
// }
|
|
//}
|
|
|
|
/// Tab-pages for pressure meters
|
|
if (factory is Rig.Elde.PressureMeter.PressureMeterFactory ||
|
|
factory is Rig.Elde.PressureMeterInternal.PressureMeterFactory ||
|
|
factory is Rig.Modbus.PressureMeter.Meret.Factory)
|
|
{
|
|
pressMetersCount++;
|
|
TabPage tabPage = new TabPage(" " + cmpnt.Name + " ");
|
|
UncertntDlgPressMeterTab uiControl = new UncertntDlgPressMeterTab();
|
|
uiControl.MeterEntity = cmpnt;
|
|
uiControl.Dock = DockStyle.Fill;
|
|
tabPage.Tag = uiControl;
|
|
tabPage.Controls.Add(uiControl);
|
|
uncertaintiesTabControl.TabPages.Add(tabPage);
|
|
}
|
|
|
|
/// Tab-pages for temperature meters (incl. platinum temp. meter with Keithley)
|
|
if (factory is Rig.Elde.TempMeter.TempMeterFactory ||
|
|
factory is Rig.Elde.TempMeterInternal.TempMeterFactory ||
|
|
factory is Rig.Keithley.TempMeter.Factory)
|
|
{
|
|
tempMetersCount++;
|
|
TabPage tabPage = new TabPage(" " + cmpnt.Name + " ");
|
|
UncertntDlgTempMeterTab uiControl = new UncertntDlgTempMeterTab();
|
|
uiControl.MeterEntity = cmpnt;
|
|
uiControl.Dock = DockStyle.Fill;
|
|
tabPage.Tag = uiControl;
|
|
tabPage.Controls.Add(uiControl);
|
|
uncertaintiesTabControl.TabPages.Add(tabPage);
|
|
}
|
|
|
|
///// Tab-pages for diverters
|
|
//if (factory is Rig.Elde.Diverter.DiverterFactory)
|
|
//{
|
|
// divertersCount++;
|
|
// TabPage tabPage = new TabPage(" " + cmpnt.Name + " ");
|
|
// MetrologyDlgDiverterTab uiControl = new MetrologyDlgDiverterTab();
|
|
// uiControl.MeterEntity = cmpnt;
|
|
// uiControl.CalibInfoCfg = factory.CmpntCfgFromCmpntEntity(cmpnt) as Rig.GenericDevices.ICalibInfoCfg;
|
|
// uiControl.Dock = DockStyle.Fill;
|
|
// tabPage.Tag = uiControl;
|
|
// tabPage.Controls.Add(uiControl);
|
|
// metrologyTabControl.TabPages.Add(tabPage);
|
|
//}
|
|
|
|
///// Tab-pages for level meters inside water tanks
|
|
//if (factory is Rig.Hart.Nivotrack.Factory)
|
|
//{
|
|
// levelMetersCount++;
|
|
// TabPage tabPage = new TabPage(" " + cmpnt.Name + " ");
|
|
// MetrologyDlgLevelMeterTab uiControl = new MetrologyDlgLevelMeterTab();
|
|
// uiControl.MeterEntity = cmpnt;
|
|
// uiControl.CalibInfoCfg = factory.CmpntCfgFromCmpntEntity(cmpnt) as Rig.GenericDevices.ICalibInfoCfg;
|
|
// uiControl.Dock = DockStyle.Fill;
|
|
// tabPage.Tag = uiControl;
|
|
// tabPage.Controls.Add(uiControl);
|
|
// metrologyTabControl.TabPages.Add(tabPage);
|
|
//}
|
|
|
|
///// Tab-pages for water tank evaporation rates
|
|
//if (factory is Rig.Various.Evaporation.Factory)
|
|
//{
|
|
// evaporationsCount++;
|
|
// TabPage tabPage = new TabPage(" " + cmpnt.Name + " ");
|
|
// MetrologyDlgEvaporationTab uiControl = new MetrologyDlgEvaporationTab();
|
|
// uiControl.MeterEntity = cmpnt;
|
|
// uiControl.CalibInfoCfg = factory.CmpntCfgFromCmpntEntity(cmpnt) as Rig.GenericDevices.ICalibInfoCfg;
|
|
// uiControl.Dock = DockStyle.Fill;
|
|
// tabPage.Tag = uiControl;
|
|
// tabPage.Controls.Add(uiControl);
|
|
// metrologyTabControl.TabPages.Add(tabPage);
|
|
//}
|
|
}
|
|
}
|
|
|
|
private void unlockButton_Click(object sender, EventArgs e)
|
|
{
|
|
foreach (TabPage tabPage in uncertaintiesTabControl.TabPages)
|
|
{
|
|
(tabPage.Tag as IUncetaintiesDlgTab).Unlock();
|
|
}
|
|
}
|
|
|
|
private void okButton_Click(object sender, EventArgs e)
|
|
{
|
|
using (ITransaction transaction = Session.BeginTransaction())
|
|
{
|
|
try
|
|
{
|
|
foreach (TabPage tabPage in uncertaintiesTabControl.TabPages)
|
|
{
|
|
IUncetaintiesDlgTab tab = tabPage.Tag as IUncetaintiesDlgTab;
|
|
if (tab != null)
|
|
{
|
|
tab.OkBtnClicked();
|
|
Session.SaveOrUpdate(tab.MeterEntity);
|
|
foreach (var entity in tab.ToBeRemoved) Session.Delete(entity);
|
|
}
|
|
}
|
|
transaction.Commit();
|
|
Session.Flush();
|
|
}
|
|
catch (Exception exc)
|
|
{
|
|
transaction.Rollback();
|
|
log.ErrorFormat("Cannot save changes to DB: {0}", exc.Message);
|
|
MessageBox.Show(Strings.Cannot_save_changes, Strings.Error, MessageBoxButtons.OK, MessageBoxIcon.Exclamation);
|
|
}
|
|
}
|
|
|
|
SaveUISettings();
|
|
DialogResult = DialogResult.OK;
|
|
Close();
|
|
}
|
|
|
|
private void cancelButton_Click(object sender, EventArgs e)
|
|
{
|
|
foreach (TabPage tabPage in uncertaintiesTabControl.TabPages)
|
|
{
|
|
(tabPage.Tag as IUncetaintiesDlgTab).CancelBtnClicked();
|
|
}
|
|
|
|
SaveUISettings();
|
|
DialogResult = DialogResult.Cancel;
|
|
Close();
|
|
}
|
|
|
|
private void SaveUISettings()
|
|
{
|
|
/// Obtain UncertaintyDlg dimensions, etc.
|
|
bool isMaximized = (WindowState == FormWindowState.Maximized);
|
|
int left = (WindowState == FormWindowState.Normal) ? Location.X : RestoreBounds.Left;
|
|
int top = (WindowState == FormWindowState.Normal) ? Location.Y : RestoreBounds.Top;
|
|
int width = (WindowState == FormWindowState.Normal) ? Size.Width : RestoreBounds.Width;
|
|
int height = (WindowState == FormWindowState.Normal) ? Size.Height : RestoreBounds.Height;
|
|
|
|
LocalSettings ls = Program.LocalSettings;
|
|
|
|
if (ls != null && (ls.UncertaintyDlgMaximized != isMaximized ||
|
|
ls.UncertaintyDlgLeft != left ||
|
|
ls.UncertaintyDlgTop != top ||
|
|
ls.UncertaintyDlgWidth != width ||
|
|
ls.UncertaintyDlgHeight != height))
|
|
{
|
|
/// At least one UncertaintyDlg dimension differs => Update local settings and save them
|
|
ls.UncertaintyDlgMaximized = isMaximized;
|
|
ls.UncertaintyDlgLeft = left;
|
|
ls.UncertaintyDlgTop = top;
|
|
ls.UncertaintyDlgWidth = width;
|
|
ls.UncertaintyDlgHeight = height;
|
|
ls.Save();
|
|
}
|
|
}
|
|
|
|
private void LoadUISettings()
|
|
{
|
|
TBF.LocalSettings ls = Program.LocalSettings;
|
|
WindowState = (ls.UncertaintyDlgMaximized ? FormWindowState.Maximized : FormWindowState.Normal);
|
|
Width = (ls.UncertaintyDlgWidth > 0) ? ls.UncertaintyDlgWidth : 900;
|
|
Height = (ls.UncertaintyDlgHeight > 0) ? ls.UncertaintyDlgHeight : 500;
|
|
Left = (ls.UncertaintyDlgLeft != 0) ? ls.UncertaintyDlgLeft : 200;
|
|
Top = (ls.UncertaintyDlgTop != 0) ? ls.UncertaintyDlgTop : 100;
|
|
}
|
|
|
|
private void addButton_Click(object sender, EventArgs e)
|
|
{
|
|
(uncertaintiesTabControl.SelectedTab.Tag as IUncetaintiesDlgTab).AddOne();
|
|
}
|
|
|
|
private void removeButton_Click(object sender, EventArgs e)
|
|
{
|
|
(uncertaintiesTabControl.SelectedTab.Tag as IUncetaintiesDlgTab).RemoveSelected();
|
|
}
|
|
|
|
public void UpdateButtonStates(SharedButtons.SelectedItemPos selectedItemPos)
|
|
{
|
|
if (selectedItemPos == SharedButtons.SelectedItemPos.None)
|
|
{
|
|
sharedButtons.DisableButtons(SharedButtons.Buttons.Remove);
|
|
}
|
|
else
|
|
{
|
|
sharedButtons.EnableButtons(SharedButtons.Buttons.Remove);
|
|
}
|
|
}
|
|
|
|
private void metrologyTabControl_SelectedIndexChanged(object sender, EventArgs e)
|
|
{
|
|
sharedButtons.DisableButtons(SharedButtons.Buttons.Remove);
|
|
}
|
|
|
|
private void UncertaintiesDlg_FormClosing(object sender, FormClosingEventArgs e)
|
|
{
|
|
if (Users.CurrentUser.Restore(this)) Program.MainWnd.UpdateUser();
|
|
if (Session != null && Session.IsOpen) Session.Close();
|
|
}
|
|
}
|
|
}
|