Ambient
|
XmlSerializers created by XmlSerializer.FromType(new[] {typeof(...)})[0]; This prevents throwing an exception => better debugging.
|
2017-06-22 21:37:05 +02:00 |
|
BenchInfo
|
XmlSerializers created by XmlSerializer.FromType(new[] {typeof(...)})[0]; This prevents throwing an exception => better debugging.
|
2017-06-22 21:37:05 +02:00 |
|
Configs/NameOnly
|
XmlSerializers created by XmlSerializer.FromType(new[] {typeof(...)})[0]; This prevents throwing an exception => better debugging.
|
2017-06-22 21:37:05 +02:00 |
|
Danfoss/VLT2800
|
XmlSerializers created by XmlSerializer.FromType(new[] {typeof(...)})[0]; This prevents throwing an exception => better debugging.
|
2017-06-22 21:37:05 +02:00 |
|
DataEntry
|
DataEntry.StandardCamera.TestStartEndForm : Combination of zoom and rotation fixed.
|
2017-11-30 21:35:14 +01:00 |
|
DB/SensusOracle
|
Changes for Audit, ver. 2.17.730
|
2017-11-13 16:17:36 +01:00 |
|
Dummy
|
All scales support GetSerNumOp (however some return null). Reading S/N of all scales on program startup, ver. 2.14.588
|
2017-06-26 13:22:36 +02:00 |
|
Elde
|
DataEntry.Munich3, DataEntry.StandardCamera use FixedStartRegisterReader and RoiForFixedStart procedure parameter PulsesPerLtr.
|
2017-11-22 01:22:59 +01:00 |
|
Generic
|
DeviceTest program functional, runs operation Modbus.PressureMeter.Meret.ReadPressureOp(...)
|
2016-10-18 11:30:02 +02:00 |
|
GenericDevices
|
DataEntry.StandardCamera changes: ShowTestEndFormOp uses regReaders, ShowDeferredTestEvalFormOp, etc.
|
2017-11-22 23:53:41 +01:00 |
|
Keithley
|
XmlSerializers created by XmlSerializer.FromType(new[] {typeof(...)})[0]; This prevents throwing an exception => better debugging.
|
2017-06-22 21:37:05 +02:00 |
|
MettlerToledo
|
Draining can be stopped by drain buttons, not by STOP button.
|
2017-07-19 16:38:46 +03:00 |
|
Modbus
|
Modbus and QuidoRS modifications: Messages are send immediately (are not enqueued) if permitted by timing.
|
2017-11-09 10:17:10 +01:00 |
|
Network
|
More camera logging, ROI: imgFileNamePrefix, ver. 2.17.748
|
2017-11-23 13:41:33 +01:00 |
|
Operations
|
BenchControlPanel supports Drain buttons highlighting (3 states).
|
2017-07-19 08:00:51 +02:00 |
|
Output
|
Output.FileWriters.Basic : PrintCaption parameter added, no empty line when there are no common items, ver. 2.17.752
|
2017-12-01 10:53:11 +01:00 |
|
ResultsPrinters
|
XmlSerializers created by XmlSerializer.FromType(new[] {typeof(...)})[0]; This prevents throwing an exception => better debugging.
|
2017-06-22 21:37:05 +02:00 |
|
Sequences
|
MainSeq : Deferred test evaluation when single test is executed.
|
2017-11-23 09:15:25 +01:00 |
|
TestMethods
|
More camera logging, ROI: imgFileNamePrefix, ver. 2.17.748
|
2017-11-23 13:41:33 +01:00 |
|
Various/ErrorFlags
|
ErrorFlags : Cosmetical bug fix.
|
2017-11-26 22:31:51 +01:00 |
|
WaterMeters
|
DataEntry.Munich3, DataEntry.StandardCamera use FixedStartRegisterReader and RoiForFixedStart procedure parameter PulsesPerLtr.
|
2017-11-22 01:22:59 +01:00 |
|
BenchPath.cs
|
PressMtrDelta added to BenchPath, PressDeltaXyz added to TestRslt, test methods modified, ver. 2.12.373
|
2016-10-18 19:14:01 +02:00 |
|
CfgChangeArgs.cs
|
|
|
|
CmdResponseArgs.cs
|
|
|
|
ComponentBase.cs
|
|
|
|
ComponentCfgBase.cs
|
XmlSerializers created by XmlSerializer.FromType(new[] {typeof(...)})[0]; This prevents throwing an exception => better debugging.
|
2017-06-22 21:37:05 +02:00 |
|
Constants.cs
|
(1) TankFullFactor -> 0.95, (2) bit80 calculation for PETERSBURG_200, ver. 2.15.626
|
2017-07-25 10:06:31 +03:00 |
|
Events.cs
|
FixesStartDeferredEvaluation test methods added, based on FixedStartMassCollection, TODO: Change functionality, ver. 2.17.745
|
2017-11-22 12:12:04 +01:00 |
|
FeedingPath.cs
|
IRegulValve change, regulation valves support Category, Category saved in settings, used in Feeding Paths UI, not used in tests yet, ver. 2.11.364
|
2016-10-12 15:47:45 +02:00 |
|
Formulas.cs
|
Error Formula modified.
|
2017-10-17 11:12:04 +02:00 |
|
HeatMetersPath.cs
|
HeatMetersPath modifications, DB change.
|
2016-08-17 10:32:03 +02:00 |
|
IOperation.cs
|
|
|
|
MetersPath.cs
|
Qfrom, Qto removed from MetersPath, ver. 2.9.326
|
2016-07-11 10:20:50 +02:00 |
|
OutputPath.cs
|
Drain valve removed from Output path, outPath.Scale.DrainValve used instead of outPath.DrainValve, wait for Event. BalanceDone before 2nd mass measurement in FlyingStartMassCollection, ver. 2.12.519
|
2017-03-29 09:22:39 +02:00 |
|
ProcedureParamsBase.cs
|
XmlSerializers created by XmlSerializer.FromType(new[] {typeof(...)})[0]; This prevents throwing an exception => better debugging.
|
2017-06-22 21:37:05 +02:00 |
|
State.cs
|
Drain valves are specified as component parameters, tank draining on startup fixed, WaitTankEmptyOp, basic TankDraining management, etc, ver. 2.12.517
|
2017-03-28 12:50:09 +02:00 |
|
StateMachine.cs
|
Repettition nr. > 1 can be selected in the main sequence.
|
2017-10-19 09:19:31 +02:00 |
|
TbfComponents.cs
|
FixesStartDeferredEvaluation test methods added, based on FixedStartMassCollection, TODO: Change functionality, ver. 2.17.745
|
2017-11-22 12:12:04 +01:00 |
|
TestBenchSim.cs
|
Symbols: introduced IPERL, ORACLE_DB, HEAT_METERS, TURA_IPERL, TURA_SPECIAL
|
2017-02-14 13:42:22 +01:00 |
|
TestParamsBase.cs
|
XmlSerializers created by XmlSerializer.FromType(new[] {typeof(...)})[0]; This prevents throwing an exception => better debugging.
|
2017-06-22 21:37:05 +02:00 |
|
Transition.cs
|
|
|