tbf/TBF/BenchControl/Elde/FlowMeter/FlowMeter.cs

89 lines
3.3 KiB
C#

///
/// Copyright (c) 2013-2018 Sensus Slovensko a.s.
///
using System;
using System.Collections.Generic;
using log4net;
using TBF.Boxes;
namespace TBF.BenchControl.Elde.FlowMeter
{
public class FlowMeter : ComponentBase, GenericDevices.IFlowMeter
{
private static readonly ILog log = LogManager.GetLogger(typeof(FlowMeter));
public override string ToString() { return string.Format("FlowMeter({0})", Cfg.ToString(1)); }
readonly FlowMeterCfg flowMeterCfg;
readonly ControlBoardDev controlBoard;
public int Idx1 { get { return flowMeterCfg.Idx1; } }
public float NominalFlow { get { return flowMeterCfg.NominalFlow; } }
public float LtrPerPulse { get { return flowMeterCfg.NominalFlow / 7200.0f; } } /// Nominal frequency is 2000 Hz
public float LtrPerPulseCorrected(double flow, int rangeIx)
{
if (flow < 0.1 * NominalFlow) return LtrPerPulse; /// No correction for small flow
/// Apply correction
var rangeCorrections = new List<Config.Entities.MeasurementCorrection>();
foreach (var corr in Corrections)
{
if (corr.RangeIx == rangeIx) rangeCorrections.Add(corr);
}
double correctedFlow = Config.Formulas.CorrectedValue(flow, rangeCorrections);
return (float)(LtrPerPulse * correctedFlow / flow);
}
public bool RangeEnabled(int ix) { return flowMeterCfg.RangeEnabled(ix); }
public double GetTempLo(int ix) { return flowMeterCfg.GetTempLo(ix); }
public double GetTempHi(int ix) { return flowMeterCfg.GetTempHi(ix); }
public double GetPressLo(int ix) { return flowMeterCfg.GetPressLo(ix); }
public double GetPressHi(int ix) { return flowMeterCfg.GetPressHi(ix); }
public FlowMeter()
{
}
public FlowMeter(Generic.IComponentCfg cfg, IList<Generic.IComponent> components)
: base(cfg)
{
flowMeterCfg = cfg as FlowMeterCfg;
controlBoard = (ControlBoardDev)TbfComponents.FindComponent(cfg.ParentName, components);
if (controlBoard == null) throw new Exception("Cannot find " + Name + " parent");
/// Prepare data for SendCalibData() control board component method
if (Idx1 >= controlBoard.EtCalib.Length) throw new Exception("Flowmeter " + Name + " parameter 'Idx1' is out of range");
controlBoard.EtCalib[Idx1] = flowMeterCfg.NominalFlow;
log.Debug(this.ToString());
}
public double ReadFlow() { return controlBoard.ReferenceFlow; }
public double ReadFrequency() { return controlBoard.ReferenceFreq; }
/// <summary>
/// Events: FlowDone, Error
/// </summary>
/// <param name="flow">Reference to a variable for the flow in Bar</param>
/// <returns>ReadFlowOp instance reference casted to IOperaton</returns>
public IOperation ReadFlowOp(ref DoubleBox flow)
{
return new ReadFlowOp(this, controlBoard, ref flow);
}
/// <summary>
/// Events: flowDone, Error
/// </summary>
/// <param name="flow">Reference to a variable for the flow in Bar</param>
/// <param name="flowDone">Event returned when measurement done</param>
/// <returns>ReadFlowOp instance reference casted to IOperaton</returns>
public IOperation ReadFlowOp(ref DoubleBox flow, Event flowDone)
{
return new ReadFlowOp(this, controlBoard, ref flow, flowDone);
}
}
}