tbf/TBF/Rig/TestMethods/StandingStartMassCollection
Marek Frniak 93d7456ccd <Fix>: RefPulses carry-over by restoring testInProgress behavior in StandingStartMassCollection, increase revision to 3.9.3134.112
Cause:
1. Background: there was a suspicion that the Bukoven board left RefPulses active across operations; this was investigated and ruled out. The pulse counter is reset by testInProgress when an operation is reused. During the third DataEntry window testInProgress had been temporarily disabled (SLM vs Karlsruhe difference), which allowed RefPulses to appear to persist.
2. Increase revision to 3.9.3134.112

Solution:
1. Restore/ensure testInProgress behavior during the DataEntry sequence and explicitly reset the pulse counter when starting a new operation.
2. Increased revision to 3.9.3134.112
2026-08-04 16:21:33 +02:00
..
Compound iPerl ASIC - implementation 2026-03-12 14:50:47 +01:00
HeatMeters iPerl ASIC - implementation 2026-03-12 14:50:47 +01:00
Single iPerl ASIC - implementation 2026-03-12 14:50:47 +01:00
StandingStartMassCollectionSeq.cs <Fix>: RefPulses carry-over by restoring testInProgress behavior in StandingStartMassCollection, increase revision to 3.9.3134.112 2026-08-04 16:21:33 +02:00