using TBF.Rig.RegisterReaders.iPerlASICReader.communication.C4.diagnosticLed.utils;
|
||
|
||
namespace TBF.Rig.RegisterReaders.iPerlASICReader.communication.C4.diagnosticLed.parserer
|
||
{
|
||
/// <summary>
|
||
/// Diagnostic LED State #5 data frame.
|
||
/// <para>
|
||
/// Frame format: TAB-separated ASCII HEX fields, CRLF terminated.
|
||
/// </para>
|
||
/// <list type="table">
|
||
/// <listheader>
|
||
/// <term># / Field</term>
|
||
/// <description>Description</description>
|
||
/// </listheader>
|
||
/// <item><term>0 – xxxxxx</term><description>signed 24-bit ADC value</description></item>
|
||
/// <item><term>1 – aaaa</term><description>unsigned 16-bit Field strength (internal units)</description></item>
|
||
/// <item><term>2 – yyyy</term><description>signed 16-bit Raw flow rate (1/4 ml per bit)</description></item>
|
||
/// <item><term>3 – vvvvvv</term><description>unsigned 24-bit Raw volume accumulation (1/4 ml per bit)</description></item>
|
||
/// <item><term>4 – cccc</term><description>unsigned 16-bit Millivolts delta on field drive capacitor</description></item>
|
||
/// <item><term>5 – tttt</term><description>unsigned 16-bit Field calibration value</description></item>
|
||
/// <item><term>6 – bbbbbbbb</term><description>unsigned 32-bit ASIC timestamp (8192 ticks/sec, rolls over at 2^32)</description></item>
|
||
/// <item><term>7 – ff</term><description>unsigned 8-bit Field drive time in microseconds</description></item>
|
||
/// <item><term>8 – mmmmmmmm</term><description>signed 32-bit Mean flow rate (rolls over at 2^32)</description></item>
|
||
/// <item><term>9 – gggg</term><description>unsigned 16-bit Field 1 measurement</description></item>
|
||
/// <item><term>10 – hhhh</term><description>unsigned 16-bit Field 2 measurement</description></item>
|
||
/// <item><term>11 – cccc</term><description>unsigned 16-bit Integrator calibration positive</description></item>
|
||
/// <item><term>12 – nnnn</term><description>unsigned 16-bit Integrator calibration negative</description></item>
|
||
/// <item><term>13 – qq</term><description>unsigned 8-bit ASIC state</description></item>
|
||
/// <item><term>14 – iiii</term><description>signed 16-bit Water impedance measurement</description></item>
|
||
/// <item><term>15 – ss</term><description>unsigned 8-bit Checksum</description></item>
|
||
/// </list>
|
||
/// </summary>
|
||
public sealed class DiagnosticLedState5Data : DiagnosticLedData
|
||
{
|
||
/// <summary>Field calibration value (tttt).</summary>
|
||
public ushort FieldCalibration { get; }
|
||
|
||
/// <summary>ASIC timestamp (bbbbbbbb), 8192 ticks per second.</summary>
|
||
public uint AsicTimestamp { get; }
|
||
|
||
/// <summary>Field drive time in microseconds (ff).</summary>
|
||
public byte FieldDriveTimeUs { get; }
|
||
|
||
/// <summary>Mean flow rate (mmmmmmmm), signed 32-bit.</summary>
|
||
public int MeanFlowRate { get; }
|
||
|
||
/// <summary>Field 1 measurement (gggg).</summary>
|
||
public ushort Field1Measurement { get; }
|
||
|
||
/// <summary>Field 2 measurement (hhhh).</summary>
|
||
public ushort Field2Measurement { get; }
|
||
|
||
/// <summary>Integrator calibration positive (cccc).</summary>
|
||
public ushort IntegratorCalibrationPositive { get; }
|
||
|
||
/// <summary>Integrator calibration negative (nnnn).</summary>
|
||
public ushort IntegratorCalibrationNegative { get; }
|
||
|
||
/// <summary>ASIC state (qq).</summary>
|
||
public byte AsicState { get; }
|
||
|
||
/// <summary>Water impedance measurement (iiii), signed 16-bit.</summary>
|
||
public short WaterImpedance { get; }
|
||
|
||
public DiagnosticLedState5Data(string rawLine, string[] fields)
|
||
: base(rawLine)
|
||
{
|
||
// ---- Common fields ----
|
||
Adc24 = DiagnosticHex.ParseInt24(fields[0]);
|
||
FieldStrength = DiagnosticHex.ParseUInt16(fields[1]);
|
||
RawFlow = DiagnosticHex.ParseInt16(fields[2]);
|
||
RawVolume = DiagnosticHex.ParseUInt24(fields[3]);
|
||
CapacitorMv = DiagnosticHex.ParseUInt16(fields[4]);
|
||
|
||
// ---- State #5 specific ----
|
||
FieldCalibration = DiagnosticHex.ParseUInt16(fields[5]);
|
||
AsicTimestamp = DiagnosticHex.ParseUInt32(fields[6]);
|
||
FieldDriveTimeUs = DiagnosticHex.ParseByte(fields[7]);
|
||
|
||
MeanFlowRate = unchecked((int)DiagnosticHex.ParseUInt32(fields[8]));
|
||
|
||
Field1Measurement = DiagnosticHex.ParseUInt16(fields[9]);
|
||
Field2Measurement = DiagnosticHex.ParseUInt16(fields[10]);
|
||
|
||
IntegratorCalibrationPositive = DiagnosticHex.ParseUInt16(fields[11]);
|
||
IntegratorCalibrationNegative = DiagnosticHex.ParseUInt16(fields[12]);
|
||
|
||
AsicState = DiagnosticHex.ParseByte(fields[13]);
|
||
WaterImpedance = DiagnosticHex.ParseInt16(fields[14]);
|
||
}
|
||
}
|
||
|
||
} |