tbf/TestBenchFramework/BenchControl/Elde/RegisterReader/RegisterReader.cs

128 lines
3.3 KiB
C#

///
/// Copyright (c) 2013-2016 Sensus Metering Systems
///
using System;
using System.Collections.Generic;
using log4net;
using TBF.Boxes;
namespace TBF.BenchControl.Elde.RegisterReader
{
public class RegisterReader : ComponentBase, GenericDevices.IRegisterReader, IOperation
{
private static readonly ILog log = LogManager.GetLogger(typeof(RegisterReader));
public override string ToString() { return string.Format("RegisterReader({0})", Cfg.ToString(1)); }
readonly RegisterReaderCfg registerReaderCfg;
public int Position { get { return registerReaderCfg.Position; } } /// 1 .. inf
///
public double PulsesPerLtr { get { return (double)registerReaderCfg.ProcParams.PulsesPerLtr; } }
public double LtrsPerPulse { get { return (PulsesPerLtr <= float.Epsilon) ? 1.0 : (1 / PulsesPerLtr); ; } }
public int WMPulses { get { return wmPulses; } }
public int WMRefPulses { get { return wmRefPulses; } }
public double WMVolume { get { return LtrsPerPulse * (double)wmPulses; } }
int wmPulses;
int wmRefPulses;
/// <summary> This is to cope with counter overflow </summary>
int lastPulses;
bool lastPulsesValid;
readonly ControlBoardDev controlBoard;
public RegisterReader()
{
Clear();
}
public RegisterReader(Generic.IComponentCfg cfg, IList<Generic.IComponent> components)
: base(cfg)
{
registerReaderCfg = cfg as RegisterReaderCfg;
controlBoard = (ControlBoardDev)TbfComponents.FindComponent(cfg.ParentName, components);
if (controlBoard == null) throw new Exception("Cannot find " + Name + " parent");
/// Prepare data for SendCalibData() control board component method
log.Debug(this.ToString());
}
public void Clear()
{
wmPulses = 0;
wmRefPulses = 0;
lastPulsesValid = false;
}
public void TestCompleted()
{
ReadPulses();
}
/// <summary>
/// Events: Event.ReadRegisterDone, Event.Error
/// </summary>
/// <returns>ReadWaterMeter instance reference casted to IOperaton</returns>
public IOperation ReadRegisterOp()
{
return this;
}
private void ReadPulses()
{
if (!lastPulsesValid)
{
lastPulses = (int)controlBoard.WMeterPulses(Position);
lastPulsesValid = true;
}
else
{
UInt16 lowerWord = controlBoard.WMeterPulses(Position);
int uncorrected = (int)(((uint)lastPulses & 0xFFFF0000) | lowerWord);
if (Math.Abs(uncorrected - lastPulses) <= Int16.MaxValue)
{
lastPulses = uncorrected;
}
else if (Math.Abs(uncorrected + 65536 - lastPulses) <= Int16.MaxValue)
{
lastPulses = uncorrected + 65536;
}
else if (Math.Abs(uncorrected - 65536 - lastPulses) <= Int16.MaxValue)
{
lastPulses = uncorrected - 65536;
}
}
wmPulses = lastPulses;
wmRefPulses = (int)controlBoard.EtPulses(Position);
log.DebugFormat("Register={0} WM={1} Reference={2} Not-gated-ref={3}", Name, wmPulses, wmRefPulses, (int)controlBoard.EtPulses(0));
}
/// <summary>Start this operation</summary>
public void Start()
{
lastPulsesValid = false;
ReadPulses();
}
/// <summary>Run this operation</summary>
/// <returns>eventDone</returns>
public Event Run()
{
ReadPulses();
return Event.ReadRegisterDone;
}
/// <summary>Stop this operation</summary>
public void Stop()
{
}
}
}