397 lines
35 KiB
C#
397 lines
35 KiB
C#
///
|
|
/// Copyright (c) 2013-2017 Sensus Metering Systems
|
|
///
|
|
using System;
|
|
using System.Collections.Generic;
|
|
using Config;
|
|
using Config.Entities;
|
|
using Results.Entities;
|
|
using Results.Resources;
|
|
|
|
namespace Results
|
|
{
|
|
public class WMeterRsltItemSpec
|
|
{
|
|
///
|
|
/// Public fields
|
|
///
|
|
public readonly int Uid;
|
|
public readonly string OldUid;
|
|
public readonly string Name; /// Name-s of all items must be unique
|
|
public readonly string ToolTipText; /// Tool-Tip Text
|
|
public readonly Quantity Quantity; /// Quantity
|
|
public readonly ItemCategory Category; ///
|
|
public string Caption; /// Specifies item description to be printed as a caption (in the header, etc.)
|
|
public string TestID; /// Specifies the test
|
|
public Config.Unit Units; /// Specifies units for the output
|
|
public string Format; /// Specifies format for the output
|
|
public string Precision; /// Specifies precision for the output
|
|
public int Width; /// Specifies the number of characters of the output, 0 = automatic
|
|
public Config.Entities.Alignment Alignment; /// Specifies alignment for the output
|
|
|
|
public WMeterRsltItemSpec Clone()
|
|
{
|
|
WMeterRsltItemSpec item2 = new WMeterRsltItemSpec((ItemID)Uid, Name, ToolTipText, Quantity, Category, printDlgt);
|
|
item2.Caption = Caption;
|
|
item2.TestID = TestID;
|
|
item2.Units = Units;
|
|
item2.Format = Format;
|
|
item2.Precision = Precision;
|
|
item2.Width = Width;
|
|
item2.Alignment = Alignment;
|
|
return item2;
|
|
}
|
|
|
|
///
|
|
/// Function to pick a MeterTestResult field and convert it into a string
|
|
///
|
|
public delegate string PrintDlgt(WaterMeter waterMeterResult, string testID, Config.Unit units, string format, string precision);
|
|
|
|
private readonly PrintDlgt printDlgt;
|
|
|
|
/// <summary> Safe wrapper which replaces null-s by empty strings </summary>
|
|
public string Print(WaterMeter waterMeterResult)
|
|
{
|
|
return Print(waterMeterResult, TestID);
|
|
}
|
|
public string Print(WaterMeter waterMeterResult, string testId)
|
|
{
|
|
string str = printDlgt(waterMeterResult, testId, Units, Format, Precision);
|
|
if (str == null) str = string.Empty;
|
|
|
|
if (!string.IsNullOrEmpty(Format))
|
|
{
|
|
str = string.Format(Format, str);
|
|
}
|
|
|
|
int len = str.Length;
|
|
if (Width == 0 || len >= Width)
|
|
{
|
|
return str;
|
|
}
|
|
else if (Alignment == Config.Entities.Alignment.Left)
|
|
{
|
|
return str + new string(' ', Width - len);
|
|
}
|
|
else if (Alignment == Config.Entities.Alignment.Right)
|
|
{
|
|
return new string(' ', Width - len) + str;
|
|
}
|
|
else // Alignment.Center or Alignment.Justified
|
|
{
|
|
int nrSpaces = Width - len;
|
|
return new string(' ', nrSpaces / 2) + str + new string(' ', nrSpaces - (nrSpaces / 2));
|
|
}
|
|
}
|
|
|
|
///
|
|
/// Public constructor
|
|
///
|
|
public WMeterRsltItemSpec(ItemID itemId, string name, string toolTipText, Quantity quantity, ItemCategory category, PrintDlgt printDlgt)
|
|
{
|
|
Uid = (int)itemId;
|
|
OldUid = itemId.ToString().Replace("__", "/").Replace('_', ' ');
|
|
Name = name;
|
|
ToolTipText = toolTipText;
|
|
Quantity = quantity;
|
|
Category = category;
|
|
this.printDlgt = printDlgt;
|
|
}
|
|
|
|
///
|
|
/// Constructorwithot ToolTip text
|
|
///
|
|
public WMeterRsltItemSpec(ItemID itemId, string name, Quantity quantity, ItemCategory category, PrintDlgt printDlgt)
|
|
{
|
|
Uid = (int)itemId;
|
|
OldUid = itemId.ToString().Replace("__", "/").Replace('_', ' ');
|
|
Name = name;
|
|
ToolTipText = string.Format("{0} bla, bla, bla", Name);
|
|
Quantity = quantity;
|
|
Category = category;
|
|
this.printDlgt = printDlgt;
|
|
}
|
|
|
|
|
|
/// Static list of all available items
|
|
public static readonly IList<WMeterRsltItemSpec> AllItems;
|
|
|
|
/// Static constructor that initializes the list of all items
|
|
static WMeterRsltItemSpec()
|
|
{
|
|
AllItems = new List<WMeterRsltItemSpec>();
|
|
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.String, "String", "", Quantity.String, ItemCategory.Other, (w, t, u, f, p) => f));
|
|
|
|
/// Common
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Test_name, Strings.Test, Quantity.String, ItemCategory.TestData, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : w.GetTestRslt(t).Name()));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Procedure_name, Strings.Procedure, Quantity.String, ItemCategory.Other, (w, t, u, f, p) => w.ProcedureName()));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Batch_number, Strings.Batch_nr, Quantity.Number, ItemCategory.Other, (w, t, u, f, p) => w.BatchNr().ToString()));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Test_method, Strings.Test_method + " *", Quantity.String, ItemCategory.TestData, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : w.GetTestRslt(t).Method()));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Density, Strings.Density + " *", Quantity.Density, ItemCategory.Other, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : w.GetTestRslt(t).DensityOut.ToString(string.IsNullOrEmpty(p) ? "F1" : p))); /// [kg/m3]
|
|
|
|
/// Target values
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Q_from, Strings.Q_from + "()", Quantity.Flow, ItemCategory.TestData, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : w.GetTestRslt(t).Qfrom().ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Q_to, Strings.Q_to + "()", Quantity.Flow, ItemCategory.TestData, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : w.GetTestRslt(t).Qto().ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Test_volume, Strings.Test_vol + "()", Quantity.Volume, ItemCategory.TestData, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).TargetVolume()).ToString(string.IsNullOrEmpty(p) ? "F1" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Error_limit_Lo, Strings.ErrLimLo + "()", Quantity.Error, ItemCategory.TestData, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).ErrLimLo()).ToString(string.IsNullOrEmpty(p) ? "F1" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Error_limit_Hi, Strings.ErrLimHi + "()", Quantity.Error, ItemCategory.TestData, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).ErrLimHi()).ToString(string.IsNullOrEmpty(p) ? "F1" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Uncertainty, Strings.Uncertainty + "()", Quantity.Error, ItemCategory.TestData, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : w.GetTestRslt(t).Uncertainty().ToString(string.IsNullOrEmpty(p) ? "F2" : p)));
|
|
|
|
/// Test results
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Test_start_time, Strings.T_start + "()", Quantity.DateTime, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : (string.IsNullOrEmpty(f) ? w.GetTestRslt(t).StartTime.ToString() : string.Format(f, w.GetTestRslt(t).StartTime))));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Test_end_time, Strings.T_end + "()", Quantity.DateTime, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : (string.IsNullOrEmpty(f) ? w.GetTestRslt(t).EndTime.ToString() : string.Format(f, w.GetTestRslt(t).EndTime))));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Test_time, Strings.T_s + "()", Quantity.Time, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : w.GetTestRslt(t).TestTime.ToString(string.IsNullOrEmpty(p) ? "F2" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Flow, Strings.Flow + "()", Quantity.Flow, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Utils.DoubleToStr(Config.Units.ConvertTo(u, w.GetTestRslt(t).FlowVolume), 4)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.T_up_mean, Strings.T_in + "()", Quantity.Temperature, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).TempUpMean).ToString(string.IsNullOrEmpty(p) ? "F2" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.T_down_mean, Strings.T_out + "()", Quantity.Temperature, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).TempDownMean).ToString(string.IsNullOrEmpty(p) ? "F2" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.T_div, Strings.T_div + "()", Quantity.Temperature, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).TempDivMean).ToString(string.IsNullOrEmpty(p) ? "F2" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.P_up, Strings.P_up + "()", Quantity.Pressure, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).PressUpMean).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.P_up_start, Strings.P_up_start + "()", Quantity.Pressure, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).PressUpStart).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.P_up_end, Strings.P_up_end + "()", Quantity.Pressure, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).PressUpEnd).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.P_down, Strings.P_dn + "()", Quantity.Pressure, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).PressDownMean).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.P_down_start, Strings.P_dn_start + "()", Quantity.Pressure, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).PressDownStart).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.P_down_end, Strings.P_dn_end + "()", Quantity.Pressure, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).PressDownEnd).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.P_delta_mean, Strings.P_delta + "()", Quantity.Pressure, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).PressDeltaMean).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.P_delta_start, Strings.P_delta_start + "()", Quantity.Pressure, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).PressDeltaStart).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.P_delta_end, Strings.P_delta_end + "()", Quantity.Pressure, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).PressDeltaEnd).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Reference_error, Strings.ErrRef + "()", Quantity.Error, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).ErrorMaster).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Ambient_temperature, Strings.T_amb + "()", Quantity.Temperature, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? Config.Units.ConvertTo(u, w.Batch.AmbientTempAve()).ToString(string.IsNullOrEmpty(p) ? "F1" : p) : Config.Units.ConvertTo(u, w.GetTestRslt(t).AmbTempMean).ToString(string.IsNullOrEmpty(p) ? "F1" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Ambient_pressure, Strings.P_amb + "()", Quantity.Pressure, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? Config.Units.ConvertTo(u, w.Batch.AmbientPressAve()).ToString(string.IsNullOrEmpty(p) ? "F0" : p) : Config.Units.ConvertTo(u, w.GetTestRslt(t).AmbPressMean).ToString(string.IsNullOrEmpty(p) ? "F0" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Ambient_humidity, Strings.H_amb + "()", Quantity.Humidity, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? Config.Units.ConvertTo(u, w.Batch.AmbientHumiAve()).ToString(string.IsNullOrEmpty(p) ? "F1" : p) : Config.Units.ConvertTo(u, w.GetTestRslt(t).AmbHumiMean).ToString(string.IsNullOrEmpty(p) ? "F1" : p)));
|
|
|
|
/// Single and combined meter results
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Volume, Strings.Volume + "()", Quantity.Volume, ItemCategory.MeterResult, (w, t, u, f, p) => (w.GetMeterTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t).VolumeMeter).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Reference_volume, Strings.VolRef + "()", Quantity.Volume, ItemCategory.MeterResult, (w, t, u, f, p) => (w.GetMeterTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t).VolumeRef).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
#if TURA_IPERL || TURA_SPECIAL
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Error, Strings.Error + "()", Quantity.Error, ItemCategory.MeterResult, (w, t, u, f, p) => (w.GetMeterTestRslt(t) == null) ? "0" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t).Error).ToString(string.IsNullOrEmpty(p) ? "F2" : p)));
|
|
#else
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Error, Strings.Error + "()", Quantity.Error, ItemCategory.MeterResult, (w, t, u, f, p) => (w.GetMeterTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t).Error).ToString(string.IsNullOrEmpty(p) ? "F2" : p)));
|
|
#endif
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Passed, Strings.Result + "()", Quantity.Boolean, ItemCategory.MeterResult, (w, t, u, f, p) => (w.GetMeterTestRslt(t) == null) ? "" : w.GetMeterTestRslt(t).PassedColorStr()));
|
|
|
|
/// Water meter info
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Watermeter_type, Strings.WM_Type, Quantity.String, ItemCategory.MeterData, (w, t, u, f, p) => w.WaterMeterData.ProductName));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Producer, Strings.Producer, Quantity.String, ItemCategory.MeterData, (w, t, u, f, p) => w.WaterMeterData.Producer));
|
|
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.DN, "DN", Quantity.Length, ItemCategory.MeterData, (w, t, u, f, p) => string.IsNullOrEmpty(p) ? Config.Units.ConvertTo(u, w.WaterMeterData.DN).ToString()
|
|
: Config.Units.ConvertTo(u, w.WaterMeterData.DN).ToString(p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.L, "L", Quantity.Length, ItemCategory.MeterData, (w, t, u, f, p) => string.IsNullOrEmpty(p) ? Config.Units.ConvertTo(u, w.WaterMeterData.L).ToString()
|
|
: Config.Units.ConvertTo(u, w.WaterMeterData.L).ToString(p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Mounting, Strings.Mounting, Quantity.String, ItemCategory.MeterData, (w, t, u, f, p) => w.WaterMeterData.Mounting.ToDescription()));
|
|
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Q4, "Q4_Qmax", Quantity.Flow, ItemCategory.MeterData, (w, t, u, f, p) => string.IsNullOrEmpty(p) ? Config.Units.ConvertTo(u, w.WaterMeterData.Q4_Qmax).ToString()
|
|
: Config.Units.ConvertTo(u, w.WaterMeterData.Q4_Qmax).ToString(p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Q3, "Q3_Qn", Quantity.Flow, ItemCategory.MeterData, (w, t, u, f, p) => string.IsNullOrEmpty(p) ? Config.Units.ConvertTo(u, w.WaterMeterData.Q3_Qn).ToString()
|
|
: Config.Units.ConvertTo(u, w.WaterMeterData.Q3_Qn).ToString(p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Q2, "Q2_Qt", Quantity.Flow, ItemCategory.MeterData, (w, t, u, f, p) => string.IsNullOrEmpty(p) ? Config.Units.ConvertTo(u, w.WaterMeterData.Q2_Qt).ToString()
|
|
: Config.Units.ConvertTo(u, w.WaterMeterData.Q2_Qt).ToString(p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Q1, "Q1_Qmin", Quantity.Flow, ItemCategory.MeterData, (w, t, u, f, p) => string.IsNullOrEmpty(p) ? Config.Units.ConvertTo(u, w.WaterMeterData.Q1_Qmin).ToString()
|
|
: Config.Units.ConvertTo(u, w.WaterMeterData.Q1_Qmin).ToString(p)));
|
|
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Metrological_class, Strings.MClass, Quantity.String, ItemCategory.MeterData, (w, t, u, f, p) => w.WaterMeterData.MetrologicalClass));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Temperature_class, "Temperature class", Quantity.String, ItemCategory.MeterData, (w, t, u, f, p) => w.WaterMeterData.TemperatureClass.ToDescription()));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Pressure_loss_class, "Pressure loss class", Quantity.String, ItemCategory.MeterData, (w, t, u, f, p) => w.WaterMeterData.PressureLossClass.ToDescription()));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Max_admissible_pressure, "Max. admissible pressure", Quantity.String, ItemCategory.MeterData, (w, t, u, f, p) => w.WaterMeterData.MaxAdmissiblePressure.ToDescription()));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Flow_profile_sensitivity_class, "Flow profile sensitivity class", Quantity.String, ItemCategory.MeterData, (w, t, u, f, p) => w.WaterMeterData.FlowProfileSensitivityClass.ToDescription()));
|
|
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Approval_info, Strings.Approval, Quantity.String, ItemCategory.MeterData, (w, t, u, f, p) => w.WaterMeterData.ApprovalInfo));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Certificate, "Certificate", Quantity.String, ItemCategory.MeterData, (w, t, u, f, p) => w.WaterMeterData.Certificate));
|
|
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Pulses_per_liter, Strings.PulsesLiter, Quantity.PulsePerLtr, ItemCategory.MeterData, (w, t, u, f, p) => string.IsNullOrEmpty(p) ? w.WaterMeterData.PulsesPerLtr.ToString()
|
|
: w.WaterMeterData.PulsesPerLtr.ToString(p)));
|
|
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Text1, "Text1", Quantity.String, ItemCategory.Other, (w, t, u, f, p) => w.WaterMeterData.Text1));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Text2, "Text2", Quantity.String, ItemCategory.Other, (w, t, u, f, p) => w.WaterMeterData.Text2));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Text3, "Text3", Quantity.String, ItemCategory.Other, (w, t, u, f, p) => w.WaterMeterData.Text3));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Text4, "Text4", Quantity.String, ItemCategory.Other, (w, t, u, f, p) => w.WaterMeterData.Text4));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Text5, "Text5", Quantity.String, ItemCategory.Other, (w, t, u, f, p) => w.WaterMeterData.Text5));
|
|
|
|
/// Water meters results
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Serial_Nr, Strings.sn, Quantity.String, ItemCategory.MeterResult, (w, t, u, f, p) => w.SerialNr));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Purchase_order, Strings.PO, Quantity.String, ItemCategory.Other, (w, t, u, f, p) => w.PurchaseOrder));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Year_of_production, Strings.Year, Quantity.Number, ItemCategory.Other, (w, t, u, f, p) => w.YearOfProduction.ToString()));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.WM_Position, Strings.Pos, Quantity.Number, ItemCategory.Other, (w, t, u, f, p) => w.WMPosition.ToString()));
|
|
|
|
/// Water meters results (single)
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.End_state, Strings.End_state, Quantity.String, ItemCategory.MeterResult, (w, t, u, f, p) => w.EndState));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Pulses, Strings.Pulses + "()", Quantity.Number, ItemCategory.MeterResult, (w, t, u, f, p) => (w.GetMeterTestRslt(t) == null) ? "" : w.GetMeterTestRslt(t).PulsesMeter.ToString()));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Pulses__liter, Strings.PulsesLiter + "()", Quantity.PulsePerLtr, ItemCategory.Other, (w, t, u, f, p) => (w.GetMeterTestRslt(t) == null) ? "" : (string.IsNullOrEmpty(p) ? w.GetMeterTestRslt(t).PulsesPerLiter.ToString()
|
|
: w.GetMeterTestRslt(t).PulsesPerLiter.ToString(p))));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Reference_pulses, Strings.RefPulses + "()", Quantity.Number, ItemCategory.Other, (w, t, u, f, p) => (w.GetMeterTestRslt(t) == null) ? "" : w.GetMeterTestRslt(t).PulsesMaster.ToString()));
|
|
|
|
/// Water meters results (combined)
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Q_rise, Strings.Q_rise, Quantity.Flow, ItemCategory.MeterResult, (w, t, u, f, p) => (w.QRise == 0) ? "-" : Utils.DoubleToStr(w.QRise, 4)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Q_fall, Strings.Q_fall, Quantity.Flow, ItemCategory.MeterResult, (w, t, u, f, p) => (w.QFall == 0) ? "-" : Utils.DoubleToStr(w.QFall, 4)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Error_main, Strings.Err_main + "()", Quantity.Error, ItemCategory.MeterResult, (w, t, u, f, p) => (w.GetMeterTestRslt(t, CompoundMeterId.CompoundMain) == null) ? "" : (string.IsNullOrEmpty(p) ? w.GetMeterTestRslt(t, CompoundMeterId.CompoundMain).Error.ToString()
|
|
: w.GetMeterTestRslt(t, CompoundMeterId.CompoundMain).Error.ToString(p))));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Error_aux, Strings.Err_aux + "()", Quantity.Error, ItemCategory.MeterResult, (w, t, u, f, p) => (w.GetMeterTestRslt(t, CompoundMeterId.CompoundAux) == null) ? "" : (string.IsNullOrEmpty(p) ? w.GetMeterTestRslt(t, CompoundMeterId.CompoundAux).Error.ToString()
|
|
: w.GetMeterTestRslt(t, CompoundMeterId.CompoundAux).Error.ToString(p))));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Serial_Nr_main, Strings.sn_main, Quantity.String, ItemCategory.MeterResult, (w, t, u, f, p) => w.SerialNr));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Serial_Nr_aux, Strings.sn_aux, Quantity.String, ItemCategory.MeterResult, (w, t, u, f, p) => w.SerialNrAux));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.End_state_main, Strings.EndState_main, Quantity.String, ItemCategory.MeterResult, (w, t, u, f, p) => w.EndState));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.End_state_aux, Strings.EndState_aux, Quantity.String, ItemCategory.MeterResult, (w, t, u, f, p) => w.EndStateAux));
|
|
|
|
/// Batch info
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Test_bench_ID, Strings.Bench, Quantity.String, ItemCategory.Other, (w, t, u, f, p) => w.Batch.TestBenchId.ToString()));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Program_version, Strings.Ver, Quantity.String, ItemCategory.Other, (w, t, u, f, p) => w.Batch.ProgramVersion));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.User_name, Strings.User, Quantity.String, ItemCategory.Other, (w, t, u, f, p) => w.Batch.UserName));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.User_nr, Strings.User_nr, Quantity.Number, ItemCategory.Other, (w, t, u, f, p) => w.Batch.UserNumber.ToString()));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Watermeters, Strings.WMs, Quantity.String, ItemCategory.Other, (w, t, u, f, p) => w.Batch.WatermetersStr));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Protocol_title, Strings.Protocol, Quantity.String, ItemCategory.Other, (w, t, u, f, p) => w.Batch.ProtocolTitle));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Batch_start_time, Strings.Start, Quantity.DateTime, ItemCategory.Other, (w, t, u, f, p) => string.IsNullOrEmpty(f) ? w.Batch.StartTime.ToString() : string.Format(f, w.Batch.StartTime)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Batch_end_time, Strings.End, Quantity.DateTime, ItemCategory.Other, (w, t, u, f, p) => string.IsNullOrEmpty(f) ? w.Batch.EndTime.ToString() : string.Format(f, w.Batch.EndTime)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Lite_per_pulse_Read, "1 / PlsPerLtr_Read", Quantity.PulsePerLtr, ItemCategory.Other, (w, t, u, f, p) => string.IsNullOrEmpty(p) ? ((w.WaterMeterData.PulsesPerLtr != 0) ? 1 / w.WaterMeterData.PulsesPerLtr : 0).ToString()
|
|
: ((w.WaterMeterData.PulsesPerLtr != 0) ? 1 / w.WaterMeterData.PulsesPerLtr : 0).ToString(p)));
|
|
/// Extra water meter data
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Result_code, Strings.Result_code, Quantity.Number, ItemCategory.MeterResult, (w, t, u, f, p) => string.IsNullOrEmpty(f) ? w.ResultCode.ToString() : string.Format(f, w.ResultCode)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Remark, Strings.Remark, Quantity.String, ItemCategory.TestResult, (w, t, u, f, p) => w.Batch.Remark));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Meter_type, Strings.Meter_type, Quantity.String, ItemCategory.Other, (w, t, u, f, p) => w.WaterMeterData.Compound ? Strings.Compound : (w.WaterMeterData.HeatMeter ? Strings.Heat_meter : Strings.Single)));
|
|
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Volume_main, Strings.Volume_main + "()", Quantity.Volume, ItemCategory.MeterResult, (w, t, u, f, p) => (w.GetMeterTestRslt(t, CompoundMeterId.CompoundMain) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t).VolumeMeter).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Volume_aux, Strings.Volume_aux + "()", Quantity.Volume, ItemCategory.MeterResult, (w, t, u, f, p) => (w.GetMeterTestRslt(t, CompoundMeterId.CompoundAux) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t).VolumeMeter).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Start_volume, Strings.Start_volume + "()", Quantity.Volume, ItemCategory.MeterResult, (w, t, u, f, p) => (w.GetMeterTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t).VolumeStart).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Start_volume_main, Strings.Start_volume_main + "()", Quantity.Volume, ItemCategory.MeterResult, (w, t, u, f, p) => (w.GetMeterTestRslt(t, CompoundMeterId.CompoundMain) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t).VolumeStart).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Start_volume_aux, Strings.Start_volume_aux + "()", Quantity.Volume, ItemCategory.MeterResult, (w, t, u, f, p) => (w.GetMeterTestRslt(t, CompoundMeterId.CompoundAux) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t).VolumeStart).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.End_volume, Strings.End_volume + "()", Quantity.Volume, ItemCategory.MeterResult, (w, t, u, f, p) => (w.GetMeterTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t).VolumeEnd).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.End_volume_main, Strings.End_volume_main + "()", Quantity.Volume, ItemCategory.MeterResult, (w, t, u, f, p) => (w.GetMeterTestRslt(t, CompoundMeterId.CompoundMain) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t).VolumeEnd).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.End_volume_aux, Strings.End_volume_aux + "()", Quantity.Volume, ItemCategory.MeterResult, (w, t, u, f, p) => (w.GetMeterTestRslt(t, CompoundMeterId.CompoundAux) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t).VolumeEnd).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
|
|
#if HEAT_METERS
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Energy, Strings.Energy + "()", Quantity.Energy, ItemCategory.Other, (w, t, u, f, p) => (w.GetMeterTestRslt(t, Config.Entities.CompoundMeterId.HeatMeterEnergy) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t, Config.Entities.CompoundMeterId.HeatMeterEnergy).VolumeMeter).ToString(string.IsNullOrEmpty(p) ? "F1" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.Reference_energy, Strings.Energy_ref + "()", Quantity.Energy, ItemCategory.Other, (w, t, u, f, p) => (w.GetMeterTestRslt(t, Config.Entities.CompoundMeterId.HeatMeterEnergy) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t, Config.Entities.CompoundMeterId.HeatMeterEnergy).VolumeRef).ToString(string.IsNullOrEmpty(p) ? "F1" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.TempHiMean, "T hi me", Quantity.Temperature, ItemCategory.Other, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).Custom1).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.TempHiStart, "T hi st", Quantity.Temperature, ItemCategory.Other, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).Custom2).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.TempHiEnd, "T hi en", Quantity.Temperature, ItemCategory.Other, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).Custom3).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.TempHiAve, "T hi av", Quantity.Temperature, ItemCategory.Other, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, (w.GetTestRslt(t).Custom2 + w.GetTestRslt(t).Custom3) / 2).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.TempLoMean, "T lo me", Quantity.Temperature, ItemCategory.Other, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).Custom6).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.TempLoStart, "T lo st", Quantity.Temperature, ItemCategory.Other, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).Custom7).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.TempLoEnd, "T lo en", Quantity.Temperature, ItemCategory.Other, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).Custom8).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
AllItems.Add(new WMeterRsltItemSpec(ItemID.TempLoAve, "T lo av", Quantity.Temperature, ItemCategory.Other, (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, (w.GetTestRslt(t).Custom7 + w.GetTestRslt(t).Custom8) / 2).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
|
#endif
|
|
}
|
|
|
|
/// <summary>
|
|
/// Converts a list of 'Output item specifications' to a string array
|
|
/// </summary>
|
|
/// <param name="items"></param>
|
|
/// <returns></returns>
|
|
public static string[] ToStrArray(IList<WMeterRsltItemSpec> items)
|
|
{
|
|
int count = (items != null) ? items.Count : 0;
|
|
string[] result = new string[count];
|
|
for (int i = 0; i < count; i++)
|
|
{
|
|
result[i] = string.Format("{0}~{1}~{2}~{3}~{4}~{5}~{6}~{7}",
|
|
items[i].Uid,
|
|
items[i].Caption,
|
|
items[i].TestID,
|
|
items[i].Units,
|
|
items[i].Format,
|
|
items[i].Precision,
|
|
items[i].Width,
|
|
items[i].Alignment);
|
|
}
|
|
return result;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Converts a string array to a list of 'Output item specifications'
|
|
/// </summary>
|
|
/// <param name="strArray"></param>
|
|
/// <returns></returns>
|
|
public static IList<WMeterRsltItemSpec> FromStrArray(string[] strArray)
|
|
{
|
|
IList<WMeterRsltItemSpec> result = new List<WMeterRsltItemSpec>();
|
|
|
|
if (strArray != null)
|
|
{
|
|
for (int i = 0; i < strArray.Length; i++)
|
|
{
|
|
try
|
|
{
|
|
if (strArray[i].Contains("~"))
|
|
{
|
|
///
|
|
/// Load the new style results item specification
|
|
///
|
|
string[] field = strArray[i].Split(new char[] { '~' });
|
|
WMeterRsltItemSpec item = GetItem(int.Parse(field[0]));
|
|
|
|
item.Caption = field[1];
|
|
item.TestID = field[2];
|
|
item.Units = 0;
|
|
for (Config.Unit u = 0; u < Config.Unit.Count; u++)
|
|
{
|
|
if (u.ToString().Equals(field[3])) { item.Units = u; break; }
|
|
}
|
|
item.Format = field[4];
|
|
item.Precision = field[5];
|
|
item.Width = int.Parse(field[6]);
|
|
item.Alignment = 0;
|
|
for (Config.Entities.Alignment a = 0; a < Config.Entities.Alignment.Count; a++)
|
|
{
|
|
if (a.ToString().Equals(field[7])) { item.Alignment = a; break; }
|
|
}
|
|
|
|
result.Add(item);
|
|
}
|
|
else
|
|
{
|
|
///
|
|
/// Try to load the old style results item specification
|
|
///
|
|
bool added = false;
|
|
foreach (var it in AllItems)
|
|
{
|
|
if (strArray[i].Equals(it.OldUid))
|
|
{
|
|
WMeterRsltItemSpec item = it.Clone();
|
|
item.Caption = item.Name.Replace("()", "").Replace(" *", "");
|
|
item.Units = 0; /// use default units
|
|
item.Format = null; /// the same like format string "{0}"
|
|
item.Precision = null;
|
|
item.Width = 0; /// do not ad any extra spaces
|
|
item.Alignment = Alignment.Left;
|
|
result.Add(item);
|
|
added = true;
|
|
break;
|
|
}
|
|
}
|
|
if (!added)
|
|
{
|
|
WMeterRsltItemSpec item = GetItem(0);
|
|
item.Format = string.Format("Parse error: {0}", strArray[i]);
|
|
result.Add(item);
|
|
}
|
|
}
|
|
}
|
|
catch
|
|
{
|
|
WMeterRsltItemSpec item = GetItem(0);
|
|
item.Format = string.Format("Parse error: {0}", strArray[i]);
|
|
result.Add(item);
|
|
}
|
|
}
|
|
}
|
|
return result;
|
|
}
|
|
|
|
|
|
public static WMeterRsltItemSpec GetItem(int uid)
|
|
{
|
|
foreach (var item in AllItems)
|
|
{
|
|
if (item.Uid == uid) return item.Clone();
|
|
}
|
|
return null;
|
|
}
|
|
|
|
|
|
public static WMeterRsltItemSpec GetItem(ItemID itemId)
|
|
{
|
|
return GetItem((int)itemId);
|
|
}
|
|
}
|
|
}
|