tbf/Results/Mappings/MeterTestRsltMap.cs
Michal Buzik 52bd0d01ce Restore Genesis communication and Q3 calibration from special branches
A – Registration and execution
- Register GenesisCommunication Factory in the component list.
- Separate the Genesis form and sequence from iPerl communication.

B – Communication activities
- Restore initialization, connection, PCB reading, password and login.
- Include grouped login, mode switching and disconnection.
- Support processing up to 10 slots.

C1 – Input calibration factors
- Read three factors from Water meters / Text1–Text3.
- Validate integer values in the range 1–65535.
- Preserve the default of 15625 when all three fields are empty.

D – Q3 calibration
- Connect the Prepare Q3 → measurement → Write Q3 workflow.
- Add channel processing to FlyingStart and FlyingStartMassCollection.
- Reset previous measurement data and validate calculated factors.
- Mark factors as stored only after StoreCalibration succeeds.

E – Results and database
- Store calibration factors separately for each meter and channel.
- Add result entities, mappings and Q3 data.
- Extend DB.cs / EnsureSchema to create and update the schema.
- Preserve compatibility with the existing binary format.

Validation:
- Debug build and 18 tests passed.
- Simulated communication runs follow the same activity sequence.
- The complete Q3 workflow has not yet been verified on hardware.

Known limitation:
- An inherited mismatch in simulated responses and error propagation
  can produce an incorrect OK result; this change does not fix it.
2026-09-09 15:04:49 +02:00

57 lines
1.4 KiB
C#

///
/// Copyright (c) 2015-2021 Sensus Slovensko a.s.
///
using FluentNHibernate.Mapping;
using Results.Entities;
namespace Results.Mappings
{
class MeterTestRsltMap : ClassMap<MeterTestRslt>
{
public MeterTestRsltMap()
{
Id(x => x.Id);
Map(x => x.CompoundMeterId);
Map(x => x.RegReaderType);
Map(x => x.PulsesMeter);
Map(x => x.PulsesMaster);
Map(x => x.PulsesPerLiter);
Map(x => x.PulsesPerKilogram);
Map(x => x.VolumeStart);
Map(x => x.VolumeEnd);
Map(x => x.VolumeMeter);
Map(x => x.VolumeRef);
Map(x => x.MassMeter);
Map(x => x.MassRef);
Map(x => x.TimestampStart);
Map(x => x.TimestampEnd);
Map(x => x.TestTime);
Map(x => x.Error);
Map(x => x.ErrorMass);
Map(x => x.TestDone);
Map(x => x.Passed);
Map(x => x.PassedMass);
Map(x => x.QuantityUnits);
#if IPERL
Map(x => x.FlipMode);
Map(x => x.ExtraDataPath);
Map(x => x.X1);
Map(x => x.X2);
Map(x => x.X3);
Map(x => x.X4);
Map(x => x.X5);
Map(x => x.X6);
Map(x => x.X7);
Map(x => x.X8);
Map(x => x.X9);
#endif
#if ORACLE_DB
Map(x => x.ErrorBC).Column("LastError");
#endif
References(x => x.WaterMeter);
References(x => x.TestRslt);
Map(x => x.Q3Channel);
}
}
}