/// /// Copyright (c) 2016 Sensus Metering Systems /// using System; using System.IO.Ports; using System.Xml.Serialization; using TBF.BenchControl.Generic; namespace TBF.BenchControl.Keithley.Multimeter_2010_RS232 { public class MultimeterCfg : ComponentCfgBase, Generic.IComponentCfg { public static XmlSerializer Serializer = XmlSerializer.FromTypes(new[] { typeof(MultimeterCfg) })[0]; protected override XmlSerializer GetSerializer() { return Serializer; } public IComponentCfgCtrl GetControl() { return new MultimeterCfgCtrl(); } /// /// Serialized parameters /// public int ComPortNr; public int BaudRate; public Parity Parity; public int DataBits; public StopBits StopBits; public Handshake Handshake; /// Private parameterless constructor invoked by all other (public) constructors MultimeterCfg() { } public MultimeterCfg(string name, IComponentFactory factory) : this() { this.Name = name; this.Factory = factory; ParentName = string.Empty; ComPortNr = 5; BaudRate = 9600; Parity = System.IO.Ports.Parity.None; DataBits = 8; StopBits = System.IO.Ports.StopBits.One; Handshake = System.IO.Ports.Handshake.None; } public string ToString(int i) { return string.Format("Name={0}, Com{1}, {2}Bd, {3}-bits, parity={4}, stopBits={5}, {6}", Name, ComPortNr, BaudRate, DataBits, Parity, StopBits, Handshake); } } }