/// Copyright (c) 2015-2020 Sensus Slovensko a.s.
///
using System;
using System.Collections.Generic;
using System.Linq;
using log4net;
using Oracle.DataAccess.Client; // ODP.NET Oracle managed provider
using Config;
using Config.Entities;
using Results.Output;
using System.Text;
using Events.Entities;
namespace TBF.BenchControl.Output.DB.SensusOracle
{
public enum Retv
{
OK,
Error,
}
public enum DBUsed
{
None,
Production,
Test,
Quality,
Count
}
public enum WMKind
{
iPERL,
Mechanical,
Count
}
///
/// Test/Q designation mode for IperlLogger and IperlHead opto data files
///
public enum DesigMode
{
Auto,
Based_on_procedure,
As_specified,
Count
}
public class Database : ComponentBase, IOperation, GenericDevices.IResultsWriter, GenericDevices.IStartInfoReader, Generic.IDevice
{
private static readonly ILog log = LogManager.GetLogger(typeof(Database));
public override string ToString() { return string.Format("{0}({1})", GetType().Namespace.Substring(17), Cfg.ToString(1)); }
public const int Anbid_StaraTura = 4;
DatabaseCfg dbCfg;
public DBUsed DBUsed { get { return (dbCfg == null || dbCfg.ProcParams == null) ? DBUsed.None : dbCfg.ProcParams.DBUsed; } }
public WMKind WMKind { get { return (dbCfg == null || dbCfg.ProcParams == null) ? WMKind.iPERL : dbCfg.ProcParams.WMKind; } }
public int WMTypeId { get { return (dbCfg == null || dbCfg.ProcParams == null) ? 0 : dbCfg.ProcParams.WMTypeId; } }
public int YearOfManufacture { get { return (dbCfg == null || dbCfg.ProcParams == null) ? DateTime.Now.Year : dbCfg.ProcParams.YearOfManufacture; } }
public bool SaveResults { get { return (dbCfg == null || dbCfg.ProcParams == null) ? false : dbCfg.ProcParams.SaveResults; } }
public bool ReadStartInfo { get { return (dbCfg == null || dbCfg.ProcParams == null) ? true : dbCfg.ProcParams.ReadStartInfo; } }
public bool StartInfoIsRequired { get { return (dbCfg == null || dbCfg.ProcParams == null) ? false : dbCfg.ProcParams.StartInfoIsRequired; } }
public DesigMode DesigMode { get { return (dbCfg == null || dbCfg.ProcParams == null) ? DesigMode.Auto : dbCfg.ProcParams.DesigMode; } }
public LogType DesigType { get { return (dbCfg == null || dbCfg.ProcParams == null) ? LogType.Just_Q3Q2Q1 : dbCfg.ProcParams.DesigType; } }
enum OpState
{
None,
ReadStartInfoScheduled,
ReadStartInfoRunning,
WriteResultsScheduled,
WriteResultsRunning,
}
OpState currentOpState;
bool opCompleted;
bool anyError;
///
/// Start info is read into WaterMeter objects referenced by this array
///
IList waterMeters;
///
/// Results to print
///
Results.Entities.Batch batch;
OracleConnection productionDB; /// Production Oracle DB connection
OracleConnection qualityDB; /// Quality Oracle DB connection
OracleConnection testDB; /// Test Oracle DB connection
public OracleConnection SelectedDB
{
get
{
switch (DBUsed)
{
case DBUsed.Production: return productionDB;
case DBUsed.Quality: return qualityDB;
case DBUsed.Test: return testDB;
default:
case DBUsed.None:
return null;
}
}
}
///
/// The following 3 variables are always updated together
///
int wmTypeId;
int wmTypeRevision;
string procedureSignature;
IList oracleTestInfo; /// Raw incomplete test info from Oracle DB (or null)
SensusTestInfo[] completeTestInfo; /// Complete TBF test info obtained as the best match (never null when oracleTestInfo != null)
public Database() {}
public Database(Generic.IComponentCfg cfg)
: base(cfg)
{
dbCfg = cfg as DatabaseCfg;
currentOpState = OpState.None;
log.Warn(this.ToString());
}
///
/// IDevice interface implementation
///
public void Initialize()
{
if (dbCfg.DebugLevel == DebugMode.Simulate) return;
productionDB = new OracleConnection("Data Source=STARA01.WORLD;User Id=deltachef;Password=deltachef;");
qualityDB = new OracleConnection("Data Source=STARA01.WORLD;User Id=deltaqual;Password=test;");
testDB = new OracleConnection("Data Source=STARA_TEST.WORLD;User Id=deltachef;Password=deltachef;");
///
/// Do something with the database to see if the connection works well
///
if (DBUsed == DBUsed.Production)
{
SelectedDB.Open();
string rslt = "none";
OracleCommand cmd = new OracleCommand("select Standort from ANBIETER_SD where ANBID = 4", SelectedDB);
OracleDataReader dr = cmd.ExecuteReader();
if (dr.Read()) rslt = dr.GetString(0);
dr.Close();
SelectedDB.Close();
}
}
///
public void RunDeviceBefore() {}
public void RunDeviceAfter() {}
///
public void StopDevice()
{
if (testDB != null) testDB.Dispose();
if (qualityDB != null) qualityDB.Dispose();
if (productionDB != null) productionDB.Dispose();
}
public void StopDevice2() {}
///
/// Get a complete information about tests given water meter type Id and revision
///
/// An open Oracle DB connection
/// Water meter type Id
/// Water meter type revision
/// SensusTestInfos array
public static IList GetOracleTestInfo(OracleConnection conn, int wmTypeId, out int wmTypeRevision, out string wzTyp, out string metrolKlasse, out string zulasszeichen, out string materialNr, out double q3, out DateTime timeStamp, out string remark)
{
///
/// Read 'incomplete' TestInfo from Oracle database containing only flowId-s ad qBezeichnung-s
///
IList oraDbTinfos = new List();
///
/// For a given 'wmTypeId' find the most recent active 'wmTypeRevision'
///
wmTypeRevision = -1;
wzTyp = string.Empty;
metrolKlasse = string.Empty;
zulasszeichen = string.Empty;
materialNr = string.Empty;
q3 = 0;
timeStamp = DateTime.MinValue;
remark = string.Empty;
OracleCommand cmd = new OracleCommand("select REV_WZTYP, WZTYP, METROLKLASSE, ZULASSZEICHEN, MATERIALNR, QMAX, AENDERUNGSDATUM, BEMERKUNG from VT_WZTYP_SD where ANBID=4 and ID_WZTyp=:1 and AKTIV=:2", conn);
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wmTypeId }); ///:1
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 1 }); ///:2
///
OracleDataReader dr = cmd.ExecuteReader();
while (dr.Read())
{
wmTypeRevision = dr.GetInt32(0);
wzTyp = dr.GetString(1);
metrolKlasse = dr.GetString(2);
zulasszeichen = dr.GetString(3);
materialNr = dr.GetString(4);
q3 = dr.GetDouble(5);
timeStamp = dr.GetDateTime(6);
remark = dr.GetString(7);
}
dr.Close();
if (wmTypeRevision == -1) return null; /// No 'wmTypeRevision' found
cmd = new OracleCommand("select PRUEFUNGSNR, Q_SOLL, PRUEFZEIT, POSFEHLERKALT, NEGFEHLERKALT, PRUEFBEREICHMIN, PRUEFBEREICHMAX, QBEZEICHNUNG from VT_PRUEFPUNKT_SOLL_SD where ANBID=4 and ID_WZTyp=:1 and Rev_WZTyp=:2", conn);
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wmTypeId }); ///:1
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wmTypeRevision }); ///:2
///
dr = cmd.ExecuteReader();
while (dr.Read())
{
int pruefungsNr = dr.GetInt32(0);
double flow = Config.Units.ConvertFrom(Unit.lph, dr.GetDouble(1));
int testTime = dr.GetInt32(2);
double errLimHi = dr.GetDouble(3);
double errLimLo = dr.GetDouble(4);
int flowRangeMin = dr.GetInt32(5);
int flowRangeMax = dr.GetInt32(6);
string qBezeichnung = dr.GetString(7);
Range rng = (flowRangeMin == 90 && flowRangeMax == 100) ? Range.R90_100 :
((flowRangeMin == 95 && flowRangeMax == 105) ? Range.R95_105 :
((flowRangeMin == 100 && flowRangeMax == 110) ? Range.R100_110 : Range.Undefined));
oraDbTinfos.Add(new SensusTestInfo(pruefungsNr, qBezeichnung, flow, testTime, errLimLo, errLimHi, rng));
}
dr.Close();
if (oraDbTinfos.Count == 0) return null; /// No 'incomplete' TestInfo in Oracle DN for this 'wmTypeId' and 'wmTypeRevision'
oraDbTinfos = oraDbTinfos.OrderBy(x => x.PruefungsNrDB).ToList();
foreach (var ti in oraDbTinfos)
{
log.WarnFormat("VT_PRUEFPUNKT_SOLL_SD info : ID={0} Rev={1} PruefungsNr={2} QBezeichnung={3}", wmTypeId, wmTypeRevision, ti.PruefungsNrDB, ti.QBezeichnungDB);
}
return oraDbTinfos;
}
///
/// Reads information on start of a cycle, Events: Event.InfoRead
///
/// Results of water meters
/// Reference to the operation
public IOperation ReadStartInfoOp(IList waterMeters)
{
if ((currentOpState == OpState.ReadStartInfoRunning) || (currentOpState == OpState.WriteResultsRunning))
{
throw new Exception("Sequence error");
}
else
{
this.waterMeters = waterMeters;
currentOpState = OpState.ReadStartInfoScheduled;
return this;
}
}
///
/// Writes the test cycle results into a file, Events: Event.ResultsWritten
///
/// Batch results
/// Reference to the operation
public IOperation ProcessResultsOp(Results.Entities.Batch batch)
{
if (!SaveResults)
{
return null;
}
else if ((currentOpState == OpState.ReadStartInfoRunning) || (currentOpState == OpState.WriteResultsRunning))
{
throw new Exception("Sequence error");
}
else
{
this.batch = batch;
currentOpState = OpState.WriteResultsScheduled;
return this;
}
}
/// Start this operation
public void Start()
{
if (currentOpState == OpState.ReadStartInfoScheduled)
{
currentOpState = OpState.ReadStartInfoRunning;
}
else if (currentOpState == OpState.WriteResultsScheduled)
{
currentOpState = OpState.WriteResultsRunning;
}
opCompleted = false;
anyError = false;
}
/// Run this operation
/// Event.ResultsWritten or Event.Error
public Event Run()
{
if (currentOpState == OpState.ReadStartInfoRunning)
{
if (!opCompleted)
{
log.WarnFormat("{0} : Run() : currentOp = {1}", Name, currentOpState);
if (dbCfg.DebugLevel == DebugMode.Normal && SelectedDB != null && ReadStartInfo && waterMeters.Count != 0)
{
#if ORACLE_DB
log.WarnFormat("{0} : Run() : reading from database", Name);
if (ReadStartInfoFromDB(SelectedDB) == Retv.Error) anyError = true;
#endif
}
if (DesigMode == DesigMode.Based_on_procedure && StateMachine.Procedure != null)
{
Sequences.ProcessData.CompleteTestInfos = Results.Output.SensusTestInfo.CreateFromProcedure(StateMachine.Procedure);
}
else if (DesigMode == DesigMode.As_specified && DesigType >= 0 && DesigType < LogType.Count)
{
Sequences.ProcessData.CompleteTestInfos = SensusTestInfo.GetTestInfos(DesigType);
}
opCompleted = true;
}
return anyError ? Event.InfoNotRead : Event.InfoRead;
}
else if (currentOpState == OpState.WriteResultsRunning)
{
if (!opCompleted)
{
if (batch.WaterMeters.Count == 0) return Event.ResultsWritten;
if ((dbCfg.DebugLevel == DebugMode.Normal) && (SelectedDB != null))
{
log.WarnFormat("{0} : Run() : currentOp = {1}", Name, currentOpState);
#if ORACLE_DB
if (WriteResultsToDB(SelectedDB, batch, false) == Retv.Error) anyError = true;
#endif
}
opCompleted = true;
}
if (anyError && !string.IsNullOrEmpty(Events.DB.ConnectionString))
{
try
{
NHibernate.ISession session = Events.DB.CreateSession();
Events.DB.LoadSubscribers(session);
TBF.UiBridge.Bridge.TriggerEvent(session, Name, EventClass.ComputerResources, Severity.Error,
string.Format("Nepodarilo sa uložiť výsledky do Oracle: Číslo dávky={0}", batch.BatchNr),
string.Format("Nepodarilo sa uložiť výsledky do Oracle\r\nČíslo dávky = {0}", batch.BatchNr),
SubscriberGroup.Metrology | SubscriberGroup.Maintenance | SubscriberGroup.Production);
}
catch (Exception exc)
{
log.ErrorFormat("Triggering event(s) failed: {0}", exc.Message);
}
}
return anyError ? Event.ErrorProcessingResults : Event.ResultsWritten;
}
else
{
return Event.None;
}
}
/// Stop this operation
public void Stop()
{
currentOpState = OpState.None;
}
#if ORACLE_DB
public Retv ReadStartInfoFromDB(OracleConnection conn)
{
bool anyError = false;
try
{
conn.Open(); /// Open the Oracle database
foreach (var wMtr in waterMeters)
{
if ((wMtr != null) && (ReadSingleWMfromDB(conn, wMtr) != Retv.OK)) anyError = true;
}
}
catch (Exception exc)
{
log.ErrorFormat("Reading from ORACLE DB failed, batch={0}, error={1}", batch.BatchNr, exc.Message);
conn.Close();
return Retv.Error;
}
conn.Close();
return anyError ? Retv.Error : Retv.OK;
}
///
/// Read start info of one water meter from the database
///
/// Oracke DB connection
/// Water meter entity
/// Retv.OK when successful, Retv.Error on error
Retv ReadSingleWMfromDB(OracleConnection conn, Results.Entities.WaterMeter wm)
{
if (string.IsNullOrEmpty(wm.SerialNr)) return Retv.Error; /// No database activity possible w/o PCB number
try
{
/// Prepare a procedure signature to distinguish between different procedures with the same wmTypeId
IList wmTestNames = new List();
StringBuilder procedureSignatureSB = new StringBuilder();
foreach (var mtr in wm.RegularMeterTestRslts())
{
wmTestNames.Add(mtr.Name());
procedureSignatureSB.Append(mtr.Name());
procedureSignatureSB.Append("~");
}
if (oracleTestInfo == null || (wmTypeId == 0) || (wmTypeId != wm.WaterMeterData.WMTypeId) || (procedureSignature != procedureSignatureSB.ToString()))
{
///
/// Currnet test info. is not walid => Get a new one from Oracle and SensusTestInfo table
///
int wmTR;
string wzTypStr;
string metroKlasse;
string zulasszeichen;
string materialNr;
double q3 = 0;
DateTime timeStamp;
string remark;
IList rti = GetOracleTestInfo(conn, wm.WaterMeterData.WMTypeId, out wmTR, out wzTypStr, out metroKlasse, out zulasszeichen, out materialNr, out q3, out timeStamp, out remark);
if (rti != null)
{
/// All 5 updated together
wmTypeId = wm.WaterMeterData.WMTypeId;
wmTypeRevision = wmTR;
procedureSignature = procedureSignatureSB.ToString();
oracleTestInfo = rti;
string tInfoName;
completeTestInfo = SensusTestInfo.GetBestMatch(rti, wmTestNames, out tInfoName);
///
log.WarnFormat("Selected test info : {0}", tInfoName);
foreach (var cti in completeTestInfo)
{
log.WarnFormat("Selected test info : ID={0} Rev={1} Test={2} PrfNrDB={3} QBzDB={4} PrfNrOpto={5} QBzOpto={6} PrfNrLog={7} QBzLog={8} Range={9}", wmTypeId, wmTypeRevision,
cti.TestName, cti.PruefungsNrDB, cti.QBezeichnungDB, cti.PruefungsNrOpto, cti.QBezeichnungOpto, cti.PruefungsNrLog, cti.QBezeichnungLog, cti.Range);
}
}
else
{
return Retv.Error;
}
}
/// Write the test info. to WaterMeter entity
wm.RawTestInfos = oracleTestInfo;
wm.CompleteTestInfos = completeTestInfo;
wm.WMTypeRevision = wmTypeRevision;
/// Write the test info. to ProcessData
Sequences.ProcessData.RawTestInfos = oracleTestInfo;
Sequences.ProcessData.CompleteTestInfos = completeTestInfo;
OracleCommand cmd;
OracleDataReader dr;
// SELECT * FROM VT_ZAEHLER_PD WHERE VT_Fernum = :1 AND ANBID = 4
int maxPruefindex = 0;
string purchaseOrder = string.Empty;
int assignedSerialNr = 0;
int paletteNr = 0;
int umkartonNr = 0;
string completeSerialNr = string.Empty;
string radioAddress = string.Empty;
int testBenchID = 0;
int pruefreiheID = 0;
int wmPosition = 0;
bool passed = false;
int resultCode = 0;
int userId = 0;
int q2CorrectionRL = 0;
int q2CorrectionLR = 0;
double q2ErrorBeforeCorrection = 0;
///
/// Read data from VT_ZAEHLER_PD
///
cmd = new OracleCommand("select MAX_PRUEFINDEX, AUFTRAGSNUMMER, ZAEHLERNUMMER, PALETTE_NR, UMKARTON_NR, Z_NR_KOMPLETT, VT_MODUL_SNR from VT_ZAEHLER_PD where VT_FERNUM = :1 AND ANBID = 4", conn);
/// 100*benchId+MPix, purchase_order, assigned_s/n, palette_nr, box_nr., complete_s/n, radio_address
cmd.Parameters.Add(new OracleParameter { ParameterName = "1", OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr });
dr = cmd.ExecuteReader();
if (dr.Read())
{
int i = 0;
int benchId_x_100_plus_MaxPruefindex = dr.GetInt32(i++);
maxPruefindex = benchId_x_100_plus_MaxPruefindex % 100;
testBenchID = benchId_x_100_plus_MaxPruefindex / 100;
try { purchaseOrder = dr.GetString(i++); } catch { purchaseOrder = string.Empty; }
try { assignedSerialNr = dr.GetInt32(i++); } catch { assignedSerialNr = 0; }
try { paletteNr = dr.GetInt32(i++); } catch { paletteNr = 0; }
try { umkartonNr = dr.GetInt32(i++); } catch { umkartonNr = 0; }
try { completeSerialNr = dr.GetString(i++); } catch { completeSerialNr = string.Empty; }
try { radioAddress = dr.GetString(i++); } catch { radioAddress = string.Empty; }
}
else
{
///
/// Water meter with given PCB number was not found in ORACLE
///
log.ErrorFormat("Water meter {0} was not found in ORACLE database.", wm.SerialNr);
dr.Close();
return StartInfoIsRequired ? Retv.Error : Retv.OK;
}
dr.Close();
///
/// Read data from VT_ZAEHLER_PINDEX_PD
///
cmd = new OracleCommand("select PRUEFINDEX, ID_WZPRUEFREIHE, WT_PLATZ_NR, WZGUT, ID_BENUTZER from VT_ZAEHLER_PINDEX_PD where VT_FERNUM = :1 AND ANBID = 4", conn);
/// test_bench_ID, line_ID, WM_position, result, user_ID
cmd.Parameters.Add(new OracleParameter { ParameterName = "1", OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr });
dr = cmd.ExecuteReader();
while (dr.Read())
{
int i = 0;
int prfix = (dr.GetInt32(i++) % 100);
if (prfix == maxPruefindex)
{
pruefreiheID = dr.GetInt32(i++);
wmPosition = dr.GetInt32(i++);
passed = (dr.GetInt32(i++) != 0);
userId = dr.GetInt32(i++);
}
}
dr.Close();
///
/// Read data from VT_IP_ZAEHLER_PINDEX_PD
///
cmd = new OracleCommand("select PRUEFINDEX, Q2CORRECTIONLEFT, Q2CORRECTIONRIGHT, ERRQ2 from VT_IP_ZAEHLER_PINDEX_PD where VT_FERNUM = :1 AND ANBID = 4", conn);
/// pruefindex, Q2_correction_RL, Q2_correction_LR, Q2_error_before_correction
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr });
dr = cmd.ExecuteReader();
while (dr.Read())
{
int i = 0;
int prfix = (dr.GetInt32(i++) % 100);
if (prfix == maxPruefindex)
{
q2CorrectionRL = dr.GetInt32(i++);
q2CorrectionLR = dr.GetInt32(i++);
q2ErrorBeforeCorrection = dr.GetDouble(i++);
}
}
dr.Close();
///
/// Read data from VT_PRUEFREIHE_IST_PD
///
/// testID, flow, rel.err., passed
cmd = new OracleCommand("select PRUEFUNGSNR, Q_WZ, Q_FEHLER, Q_BEST from VT_PRUEFREIHE_IST_PD where VT_FERNUM = :1 AND PRUEFINDEX = :2 AND ANBID = 4", conn);
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 100 * testBenchID + maxPruefindex });
dr = cmd.ExecuteReader();
while (dr.Read())
{
int i = 0;
int testId = dr.GetInt32(i++);
double flow = dr.GetDouble(i++);
double error = dr.GetDouble(i++);
bool testPassed = (dr.GetInt32(i++) != 0);
string baseTestName = null;
foreach (var ti in completeTestInfo)
{
if (ti.PruefungsNrDB == testId)
{
int ix = ti.TestName.LastIndexOf(" (");
baseTestName = (ix < 0) ? ti.TestName : ti.TestName.Substring(0, ix);
break;
}
}
if (!string.IsNullOrEmpty(baseTestName))
{
foreach (var mtr in wm.MeterTestRslts)
{
string mtrTestName = mtr.TestRslt.Name();
int ix = mtrTestName.LastIndexOf(" (");
string mtrBaseTestName = (ix < 0) ? mtrTestName : mtrTestName.Substring(0, ix);
if (mtrBaseTestName == baseTestName)
{
mtr.LastError = error;
}
}
}
}
dr.Close();
///
/// Copy acquired data to WaterMeter object
///
wm.Pruefindex = maxPruefindex + 1; /// Increment the proefindex from Oracle so that it is the pruefindex of the current cycle
log.InfoFormat("Data of water meter {0} successfully read from ORACLE database.", wm.SerialNr);
log.DebugFormat(" MaxPruefindex = {0}", wm.Pruefindex);
#if TURA_SPECIAL
wm.AssignedSerialNr = assignedSerialNr;
wm.CompleteSerialNr = completeSerialNr;
wm.RadioAddress = radioAddress;
wm.PaletteNr = paletteNr;
wm.UmkartonNr = umkartonNr;
wm.ProdTestBench = Results.Utils.BenchNameFromOracleBenchID(testBenchID);
wm.ProdWMPosition = wmPosition;
wm.ProdUserName = userId.ToString();
wm.ProdPurchaseOrder = purchaseOrder;
wm.ProdPassed = passed;
wm.ProdResultCode = resultCode;
wm.ProdQ2CorrRL = q2CorrectionRL;
wm.ProdQ2CorrLR = q2CorrectionLR;
log.DebugFormat(" AssignedSerialNr = {0}", wm.AssignedSerialNr);
log.DebugFormat(" CompleteSerialNr = {0}", wm.CompleteSerialNr);
log.DebugFormat(" RadioAddress = {0}", wm.RadioAddress);
log.DebugFormat(" PaletteNr = {0}", wm.PaletteNr);
log.DebugFormat(" UmkartonNr = {0}", wm.UmkartonNr);
log.DebugFormat(" ProdTestBench = {0}", wm.ProdTestBench);
log.DebugFormat(" ProdWMPosition = {0}", wm.ProdWMPosition);
log.DebugFormat(" ProdUserName = {0}", wm.ProdUserName);
log.DebugFormat(" ProdPurchaseOrder = {0}", wm.ProdPurchaseOrder);
log.DebugFormat(" ProdPassed = {0}", wm.ProdPassed);
log.DebugFormat(" ProdResultCode = {0}", wm.ProdResultCode);
log.DebugFormat(" ProdQ2CorrRL = {0}", wm.ProdQ2CorrRL);
log.DebugFormat(" ProdQ2CorrLR = {0}", wm.ProdQ2CorrLR);
#endif
return Retv.OK;
}
catch (Exception exc)
{
log.ErrorFormat("Error reading data of water meter {0} from ORACLE database: {1}", wm.SerialNr, exc.Message);
return Retv.Error;
}
}
public Retv WriteResultsToDB(OracleConnection conn, Results.Entities.Batch batch, bool safeMode)
{
OracleTransaction transaction;
try
{
conn.Open(); /// Open the Oracle database
transaction = conn.BeginTransaction();
}
catch (Exception exc)
{
log.ErrorFormat("Results of batch {0} not written to ORACLE DB (phase 1): {1}",
batch.BatchNr, exc.Message);
conn.Close();
return Retv.Error;
}
try
{
SaveBatchData(conn, batch);
foreach (var wMtr in batch.WaterMeters)
{
if (WMKind == WMKind.iPERL)
{
if ((wMtr.ErrorFlags & ((int)ErrorFlagMask.E26 | (int)ErrorFlagMask.E27 | (int)ErrorFlagMask.E28)) == 0)
{
/// No production error => write the result of testing to Oracle DB
SaveIperlToDB(conn, wMtr, safeMode);
}
}
else if (WMKind == WMKind.Mechanical)
{
SaveMechanicalMeterToDB(conn, wMtr, safeMode);
}
}
transaction.Commit();
conn.Close();
log.ErrorFormat("Results of batch {0} correctly written to ORACLE DB", batch.BatchNr);
return Retv.OK;
}
catch (Exception exc)
{
transaction.Rollback();
conn.Close();
log.ErrorFormat("Results of batch {0} not written to ORACLE DB: {1}", batch.BatchNr, exc.Message);
return Retv.Error;
}
}
///
///
///
///
///
///
int ReadMaxPruefindex(OracleConnection conn, Results.Entities.WaterMeter wm)
{
/// Create a list of all prufindexes for a given PCB Number (the list is initially empty)
IList pruefindexes = new List();
{
OracleCommand cmd = new OracleCommand("SELECT Pruefindex FROM VT_ZAEHLER_PINDEX_PD WHERE VT_Fernum = :1 AND ANBID = 4", conn);
OracleParameter parm = new OracleParameter();
parm.OracleDbType = OracleDbType.Varchar2;
parm.Value = wm.SerialNr;
cmd.Parameters.Add(parm);
using (OracleDataReader dr = cmd.ExecuteReader())
{
while (dr.Read()) pruefindexes.Add(dr.GetInt32(0));
dr.Close();
}
}
{
OracleCommand cmd = new OracleCommand("SELECT Max_Pruefindex, Auftragsnummer, Z_Nr_Komplett, VT_Modul_Snr FROM VT_ZAEHLER_PD WHERE VT_Fernum = :1 AND ANBID = 4", conn);
/// purchase order assigned s/n radio address PCB number Producer ID
OracleParameter parm = new OracleParameter();
parm.OracleDbType = OracleDbType.Varchar2;
parm.Value = wm.SerialNr;
cmd.Parameters.Add(parm);
using (OracleDataReader dr = cmd.ExecuteReader())
{
while (dr.Read()) pruefindexes.Add(dr.GetInt32(0));
dr.Close();
}
}
/// Determine MAX_Pruefindex
int maxPrfIndex = 0;
foreach (var pix in pruefindexes)
{
if ((pix % 100) > maxPrfIndex) maxPrfIndex = (pix % 100);
}
return maxPrfIndex;
}
///
/// Save common batch data
///
/// Batch
void SaveBatchData(OracleConnection conn, Results.Entities.Batch b)
{
IList wmTestNames = new List();
StringBuilder procedureSignatureSB = new StringBuilder();
foreach (var tr in b.RegularTestRslts())
{
wmTestNames.Add(tr.Name());
procedureSignatureSB.Append(tr.Name());
procedureSignatureSB.Append("~");
}
if ((oracleTestInfo == null) || (wmTypeId != b.WaterMeters[0].WaterMeterData.WMTypeId) || (wmTypeRevision == 0) || (procedureSignature != procedureSignatureSB.ToString()))
{
int wmTR = 0;
string wzTypStr;
string metroKlasse;
string zulasszeichen;
string materialNr;
double q3 = 0;
DateTime timeStamp;
string remark;
IList ti = GetOracleTestInfo(conn, b.WaterMeters[0].WaterMeterData.WMTypeId, out wmTR, out wzTypStr, out metroKlasse, out zulasszeichen, out materialNr, out q3, out timeStamp, out remark);
if (ti != null)
{
/// All 5 updated together
wmTypeId = b.WaterMeters[0].WaterMeterData.WMTypeId;
wmTypeRevision = wmTR;
procedureSignature = procedureSignatureSB.ToString();
oracleTestInfo = ti;
completeTestInfo = SensusTestInfo.GetBestMatch(oracleTestInfo, wmTestNames);
foreach (var cti in completeTestInfo)
{
log.WarnFormat("Selected test info : ID={0} Rev={1} Test={2} PrfNrDB={3} QBzDB={4} PrfNrOpto={5} QBzOpto={6} PrfNrLog={7} QBzLog={8} Range={9}", wmTypeId, wmTypeRevision,
cti.TestName, cti.PruefungsNrDB, cti.QBezeichnungDB, cti.PruefungsNrOpto, cti.QBezeichnungOpto, cti.PruefungsNrLog, cti.QBezeichnungLog, cti.Range);
}
}
else
{
throw new Exception("No matching test infos found");
}
}
if (oracleTestInfo == null || completeTestInfo == null || wmTypeId == 0 || wmTypeRevision == 0)
{
throw new Exception("No matching test infos found");
}
if (!dbCfg.TestMode)
{
OracleCommand cmd = new OracleCommand("INSERT INTO VT_PRUEFREIHE_PD(ANBID, ID_Pruefstand, ID_WzPruefreihe, ID_WZTyp, " +
"Rev_WZTyp, Rev_Pruefstand_WZTyp, StartDatumZeit, EndDatumZeit, Betriebsart, " +
"QVzKontakt, FuellenBegDruck, DruckEvakVorne, DruckEvakHinten, DruckBeiAbpressen, " +
"Druckentwaessern, SpuelDurchflussIst, ProgrammVersion)" +
" VALUES (:1, :2, :3, :4, :5, :6, :7, :8, :9, :10, :11, :12, :13, :14, :15, :16, :17)", conn);
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = Anbid_StaraTura });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 18000 + b.TestBenchId });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = b.BatchNr });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = b.WaterMeters[0].WaterMeterData.WMTypeId });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wmTypeRevision });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 1 });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.TimeStamp, Value = b.StartTime });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.TimeStamp, Value = b.EndTime });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = string.Empty });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = 0 });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = 0 });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = 0 });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = 0 });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = 0 }); /// TODO: DruckBeiAbpressen
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = 0 });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = 0 }); /// TODO: SpuelDurchflussIst
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = string.Format("TBF v.{0}", b.ProgramVersion) });
cmd.ExecuteNonQuery(); /// Returns nr. of updated rows
log.InfoFormat("VT_PRUEFREIHE_PD inserted, BatchNr={0}, TypeId={1}, TypeRev={2}, Start={3}", b.BatchNr, b.WaterMeters[0].WaterMeterData.WMTypeId, wmTypeRevision, b.StartTime);
}
else
{
log.WarnFormat("SIM: VT_PRUEFREIHE_PD inserted, BatchNr={0}, TypeId={1}, TypeRev={2}, Start={3}", b.BatchNr, b.WaterMeters[0].WaterMeterData.WMTypeId, wmTypeRevision, b.StartTime);
}
foreach (var testInfo in completeTestInfo)
{
if ((testInfo.PruefungsNrDB != 0) && (-20 <= testInfo.PruefungsNrDB) && (testInfo.PruefungsNrDB <= 20)) /// LU PruefungsNr-s are between -20 and 20
{
Results.Entities.TestRslt tr = b.GetTestRslt(testInfo.TestName, 0);
if (tr == null) tr = b.GetTestRslt(testInfo.TestName, 1); /// TODO: Remove this workaround for large watermeters with multiple parts at Q3
if (tr == null) continue;
double Q_ist = (tr.VolumeMaster != 0) ? (tr.FlowVolume * tr.VolumeCTV / tr.VolumeMaster) : (double)tr.FlowVolume;
///
if (!dbCfg.TestMode)
{
#if false
OracleCommand cmd2 = new OracleCommand("INSERT INTO VT_PRUEFDURCHFLUSS_PD(ANBID, ID_Pruefstand, ID_WzPruefreihe, PruefungsNr, PVOL, PMasse, " +
"MinDurchfluss, MaxDurchfluss, Q_ist, KFaktor, Q_VZ, F_VZ, RegelEinstellZeit, Drehzahl, BeginnDruck_Vorne, " +
"BeginnDruck_Hinten, EndDruck_Vorne, EndDruck_Hinten, TVWZ, IVWZ, Verwendeter_VZ, BeginnGewicht, EndGewicht) " +
"VALUES (:1, :2, :3, :4, :5, :6, :7, :8, :9, :10, :11, :12, :13, :14, :15, :16, :17, :18, :19, :20, :21, :22, :23)", conn);
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = Anbid_StaraTura });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 18000 + b.TestBenchId });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = b.BatchNr });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = testInfo.PruefungsNr });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Units.ConvertTo(Unit.l, tr.VolumeCTV) });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Units.ConvertTo(Unit.kg, tr.MassEnd - tr.MassStart) });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Units.ConvertTo(Unit.lph, tr.FlowMin) });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Units.ConvertTo(Unit.lph, tr.FlowMax) });
double Q_ist = (tr.VolumeMaster != 0) ? (tr.FlowVolume * tr.VolumeCTV / tr.VolumeMaster) : (double)tr.FlowVolume;
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Units.ConvertTo(Unit.lph, Q_ist) });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = tr.ConstMaster });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Units.ConvertTo(Unit.lph, tr.FlowVolume) });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = tr.ErrorMaster });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = (double)tr.FlowSetTime });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// TODO
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Units.ConvertTo(Unit.bar, tr.PressUpStart) });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Units.ConvertTo(Unit.bar, tr.PressDownStart) });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Units.ConvertTo(Unit.bar, tr.PressUpEnd) });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Units.ConvertTo(Unit.bar, tr.PressDownEnd) });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = tr.TestTime });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = tr.PulsesMaster });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// TODO
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Units.ConvertTo(Unit.kg, tr.MassStart) });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Units.ConvertTo(Unit.kg, tr.MassEnd) });
cmd2.ExecuteNonQuery(); /// Returns nr. of updated rows
#else
OracleCommand cmd2 = new OracleCommand("INSERT INTO VT_PRUEFDURCHFLUSS_PD(" +
"ANBID, ID_Pruefstand, ID_WzPruefreihe, PruefungsNr, " +
"PVOL, PMasse, MinDurchfluss, MaxDurchfluss, " +
"Q_ist, KFaktor, Q_VZ, F_VZ, RegelEinstellZeit, Drehzahl, " +
"BeginnDruck_Vorne, BeginnDruck_Hinten, EndDruck_Vorne, EndDruck_Hinten, " +
"TVWZ, IVWZ, Verwendeter_VZ, BeginnGewicht, EndGewicht)" +
" VALUES (:1, :2, :3, :4, :5, :6, :7, :8, :9, :10, :11, :12, :13, :14, :15, " +
":16, :17, :18, :19, :20, :21, :22, :23)", conn);
OracleParameter parm;
parm = new OracleParameter("ANBID", OracleDbType.Int32); parm.Value = Anbid_StaraTura; cmd2.Parameters.Add(parm); ///:1
parm = new OracleParameter("ID_Pruefstand", OracleDbType.Int32); parm.Value = 18000 + b.TestBenchId; cmd2.Parameters.Add(parm); ///:2
parm = new OracleParameter("ID_WzPruefreihe", OracleDbType.Int32); parm.Value = b.BatchNr; cmd2.Parameters.Add(parm); ///:3
parm = new OracleParameter("PruefungsNr", OracleDbType.Int32); parm.Value = testInfo.PruefungsNrDB; cmd2.Parameters.Add(parm); ///:4
///
parm = new OracleParameter("PVOL", OracleDbType.Double); parm.Value = Units.ConvertTo(Unit.l, tr.VolumeCTV); cmd2.Parameters.Add(parm); ///:5
parm = new OracleParameter("PMasse", OracleDbType.Double); parm.Value = Units.ConvertTo(Unit.kg, tr.MassEnd - tr.MassStart); cmd2.Parameters.Add(parm); ///:6
parm = new OracleParameter("MinDurchfluss", OracleDbType.Double); parm.Value = Units.ConvertTo(Unit.lph, tr.FlowMin); cmd2.Parameters.Add(parm); ///:7
parm = new OracleParameter("MaxDurchfluss", OracleDbType.Double); parm.Value = Units.ConvertTo(Unit.lph, tr.FlowMax); cmd2.Parameters.Add(parm); ///:8
parm = new OracleParameter("Q_ist", OracleDbType.Double); parm.Value = Units.ConvertTo(Unit.lph, Q_ist); cmd2.Parameters.Add(parm); ///:9
parm = new OracleParameter("KFaktor", OracleDbType.Double); parm.Value = tr.ConstMaster; cmd2.Parameters.Add(parm); ///:10
parm = new OracleParameter("Q_VZ", OracleDbType.Double); parm.Value = Units.ConvertTo(Unit.lph, tr.FlowVolume); cmd2.Parameters.Add(parm); ///:11
parm = new OracleParameter("F_VZ", OracleDbType.Double); parm.Value = tr.ErrorMaster; cmd2.Parameters.Add(parm); ///:12
parm = new OracleParameter("RegelEinstellZeit", OracleDbType.Double); parm.Value = (double)tr.FlowSetTime; cmd2.Parameters.Add(parm); ///:13
parm = new OracleParameter("Drehzahl", OracleDbType.Int32); parm.Value = 0; /* TODO */ cmd2.Parameters.Add(parm); ///:14
///
parm = new OracleParameter("BeginnDruck_Vorne", OracleDbType.Double); parm.Value = Units.ConvertTo(Unit.bar, tr.PressUpStart); cmd2.Parameters.Add(parm); ///:15
parm = new OracleParameter("BeginnDruck_Hinten", OracleDbType.Double); parm.Value = Units.ConvertTo(Unit.bar, tr.PressDownStart); cmd2.Parameters.Add(parm); ///:16
parm = new OracleParameter("EndDruck_Vorne", OracleDbType.Double); parm.Value = Units.ConvertTo(Unit.bar, tr.PressUpEnd); cmd2.Parameters.Add(parm); ///:17
parm = new OracleParameter("EndDruck_Hinten", OracleDbType.Double); parm.Value = Units.ConvertTo(Unit.bar, tr.PressDownEnd); cmd2.Parameters.Add(parm); ///:18
///
parm = new OracleParameter("TVWZ", OracleDbType.Double); parm.Value = tr.TestTime; cmd2.Parameters.Add(parm); ///:19
parm = new OracleParameter("IVWZ", OracleDbType.Int32); parm.Value = tr.PulsesMaster; cmd2.Parameters.Add(parm); ///:20
parm = new OracleParameter("Verwendeter_VZ", OracleDbType.Int32); parm.Value = 0; /* TODO */ cmd2.Parameters.Add(parm); ///:21
parm = new OracleParameter("BeginnGewicht", OracleDbType.Double); parm.Value = Units.ConvertTo(Unit.kg, tr.MassStart); cmd2.Parameters.Add(parm); ///:22
parm = new OracleParameter("EndGewicht", OracleDbType.Double); parm.Value = Units.ConvertTo(Unit.kg, tr.MassEnd); cmd2.Parameters.Add(parm); ///:23
///
cmd2.ExecuteNonQuery(); /// Returns nr. of updated rows
log.InfoFormat("VT_PRUEFDURCHFLUSS_PD inserted ({0}, {1}, {2}, {3}, {4} ...)", Anbid_StaraTura, 18000 + b.TestBenchId, b.BatchNr, testInfo.PruefungsNrDB, Q_ist);
#endif
}
else
{
log.WarnFormat("SIM: VT_PRUEFDURCHFLUSS_PD inserted ({0}, {1}, {2}, {3}, {4} ...)", Anbid_StaraTura, 18000 + b.TestBenchId, b.BatchNr, testInfo.PruefungsNrDB, Q_ist);
}
}
}
log.InfoFormat("Batch data saved, batchNr={0}", b.BatchNr);
}
///
/// Write one meter results into the database
///
/// 0-based water meter number
/// Sorted list of results to save
void SaveIperlToDB(OracleConnection conn, Results.Entities.WaterMeter wm, bool safeMode)
{
if (safeMode && !wm.Passed) return;
if (string.IsNullOrEmpty(wm.SerialNr)) return; /// No database activity possible w/o PCB number
int maxpruefindexLowPart = ReadMaxPruefindex(conn, wm);
TBF.BenchControl.GenericDevices.IBenchInfo benchInfo = TBF.BenchControl.Sequences.ProcessData.BenchInfo;
int testBenchID = (benchInfo != null) ? benchInfo.TestBenchId : 1;
int MAX_Pruefindex = 100 * testBenchID + maxpruefindexLowPart + 1;
int Hydr_Pruefung;
if (wm.Passed)
{
/// Passed
if (maxpruefindexLowPart == 0)
Hydr_Pruefung = 96;
else
Hydr_Pruefung = 224;
}
else
{
/// Failed
Hydr_Pruefung = 97; /// Hydr. test failed, Pressure test passed
}
wm.Pruefindex = MAX_Pruefindex;
wm.HydrPruefung = Hydr_Pruefung;
SaveOrUpdateIperl(conn, wm, MAX_Pruefindex, Hydr_Pruefung);
}
void SaveOrUpdateIperl(OracleConnection conn, Results.Entities.WaterMeter wm, int max_Pruefindex, int hydr_Pruefung)
{
int sekundaere_Adr = wm.Passed ? 1 : 0;
int idBenutzer = 6; // = wm.Batch.UserNumber;
if (max_Pruefindex % 100 == 1)
{
if (!dbCfg.TestMode)
{
OracleCommand cmd = new OracleCommand("INSERT INTO VT_ZAEHLER_PD(Auftragsnummer, VT_Identnummer, VT_Fernum, Max_Pruefindex," +
" Zaehlernummer, Sekundaere_Adr, Hydr_Pruefung, ID_Benutzer, ANBID, Baujahr)" +
" VALUES (:1, :2, :3, :4, :5, :6, :7, :8, :9, :10)", conn);
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.PurchaseOrder });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = "IPBATMXX" });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = max_Pruefindex });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = -1 });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = sekundaere_Adr });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = hydr_Pruefung });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = idBenutzer });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = Anbid_StaraTura });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = YearOfManufacture });
cmd.ExecuteNonQuery();
log.InfoFormat("VT_ZAEHLER_PD inserted, PcbNr={0}, pos={1}, maxPruefix={2}", wm.SerialNr, wm.WMPosition, max_Pruefindex);
}
else
{
log.WarnFormat("SIM: VT_ZAEHLER_PD inserted, PcbNr={0}, pos={1}, maxPruefix={2}", wm.SerialNr, wm.WMPosition, max_Pruefindex);
}
}
else
{
if (!dbCfg.TestMode)
{
OracleCommand cmd = new OracleCommand("UPDATE VT_ZAEHLER_PD SET Auftragsnummer = :1, VT_Identnummer = :2, Max_Pruefindex = :3, Hydr_Pruefung= :4, ID_Benutzer= :5, Baujahr= :6 WHERE VT_Fernum = :7 and ANBID = :8", conn);
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.PurchaseOrder });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = "IPBATMXX" });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = max_Pruefindex });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = hydr_Pruefung });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = idBenutzer });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = YearOfManufacture });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = Anbid_StaraTura });
cmd.ExecuteNonQuery();
log.InfoFormat("VT_ZAEHLER_PD updated, PcbNr={0}, pos={1}, maxPruefix={2}", wm.SerialNr, wm.WMPosition, max_Pruefindex);
}
else
{
log.WarnFormat("SIM: VT_ZAEHLER_PD updated, PcbNr={0}, pos={1}, maxPruefix={2}", wm.SerialNr, wm.WMPosition, max_Pruefindex);
}
}
if (!dbCfg.TestMode)
{
OracleCommand cmd = new OracleCommand("INSERT INTO VT_ZAEHLER_PINDEX_PD(" +
"VT_Fernum, Pruefindex, ANBID, ID_Pruefstand, ID_WzPruefreihe, Hydr_Pruefung, " +
"ReedKontakt, ReedKontaktOK, ReedKontaktZeit, KorrImprate, FestWertWZ, PtestOK, " +
"Zaehlerstand, WT_Platz_NR, WZgut, ID_Benutzer, AnzahlPruefungen)" +
" VALUES (:1, :2, :3, :4, :5, :6, 0, 0, 0, :7, 0, :8, 0, :9, :10, :11, :12)", conn); /// ReedKontakt = ReedKontaktOK = ReedKontaktZeit = FestWertWZ = Zaehlerstand = 0
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = max_Pruefindex });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = Anbid_StaraTura });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 18000 + wm.Batch.TestBenchId });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wm.Batch.BatchNr });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = hydr_Pruefung });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = wm.OrigCalibFactor });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// TODO
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wm.WMPosition });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wm.Passed ? 1 : 0 });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = idBenutzer });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 3 });
cmd.ExecuteNonQuery();
log.InfoFormat("VT_ZAEHLER_PINDEX_PD inserted, PcbNr={0}, pos={1}, pruefix={2}", wm.SerialNr, wm.WMPosition, max_Pruefindex % 100);
}
else
{
log.WarnFormat("SIM: VT_ZAEHLER_PINDEX_PD inserted, PcbNr={0}, pos={1}, pruefix={2}", wm.SerialNr, wm.WMPosition, max_Pruefindex % 100);
}
foreach (var testInfo in completeTestInfo)
{
if ((testInfo.PruefungsNrDB != 0) && (-20 <= testInfo.PruefungsNrDB) && (testInfo.PruefungsNrDB <= 20)) /// LU PruefungsNr-s are nonzero and between -20 and 20
{
Results.Entities.TestData tData = wm.GetTestData(testInfo.TestName);
Results.Entities.MeterTestRslt mtr;
if (tData == null)
{
throw new Exception(string.Format("'{0}' test results missing, watermeter {1}", testInfo.TestName, wm.WMPosition));
}
else if (tData.Repeats == 1)
{
mtr = wm.GetMeterTestRslt(testInfo.TestName);
if (mtr == null) throw new Exception(string.Format("'{0}' test results missing, watermeter {1}", testInfo.TestName, wm.WMPosition));
}
else
{
Results.Entities.MeterTestRslt firstMtr = wm.GetMeterTestRslt(Utils.TestTitle(tData, 1));
if (firstMtr == null) throw new Exception(string.Format("'{0}' test results missing, watermeter {1}", Utils.TestTitle(tData, 1), wm.WMPosition));
mtr = new Results.Entities.MeterTestRslt();
mtr.CopyContentFrom(firstMtr);
mtr.TestRslt = firstMtr.TestRslt;
mtr.WaterMeter = firstMtr.WaterMeter;
for (int i = 2; i <= tData.Repeats; i++)
{
Results.Entities.MeterTestRslt nextMtr = wm.GetMeterTestRslt(Utils.TestTitle(tData, i));
if (nextMtr == null) throw new Exception(string.Format("'{0}' test results missing, watermeter {1}", Utils.TestTitle(tData, i), wm.WMPosition));
mtr.TestTime += nextMtr.TestTime;
mtr.VolumeMeter += nextMtr.VolumeMeter;
mtr.VolumeRef += nextMtr.VolumeRef;
mtr.VolumeEnd = nextMtr.VolumeEnd;
mtr.Passed = (mtr.Passed && nextMtr.Passed);
}
mtr.Error = Formulas.ErrorFromVolumes(mtr.VolumeMeter, mtr.VolumeRef);
}
SaveMeterTestResult(conn, mtr, testInfo.PruefungsNrDB, max_Pruefindex, wmTypeRevision);
}
}
if (!dbCfg.TestMode)
{
double q2ErrWOCorrection = Math.Min(100.0, Math.Max(-100.0, wm.Q2ErrWOCorrection));
OracleCommand cmd = new OracleCommand("INSERT INTO VT_IP_ZAEHLER_PINDEX_PD(" +
"VT_Fernum, Pruefindex, ANBID, WITHCORRECTION2HZ, CORRECTION2HZ, DIFF2HZ8HZ, " +
"WITHQ2CORRECTION, Q2CORRECTIONRIGHT, ERRQ2, Q2CORRECTIONFLOWRIGHT, Q2CORRECTIONLEFT)" +
" VALUES (:1, :2, :3, :4, :5, :6, :7, :8, :9, :10, :11)", conn);
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = max_Pruefindex });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = Anbid_StaraTura });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wm.Hz2CorrectionDone ? 1 : 0 });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = wm.Hz2Correction });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Math.Min(99.0, Math.Max(-99.0, wm.Diff2Hz8Hz)) });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = ((wm.Q2CorrRL != 0) || (wm.Q2CorrLR != 0)) ? 1 : 0 });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wm.Q2CorrLR });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = q2ErrWOCorrection });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wm.Q2CorrFlowRight }); /// 1 = R->L
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wm.Q2CorrRL });
int rowsUpdated = cmd.ExecuteNonQuery();
log.InfoFormat("VT_IP_ZAEHLER_PINDEX_PD inserted, PcbNr={0}, pruefix={1}", wm.SerialNr, max_Pruefindex);
}
else
{
log.WarnFormat("SIM: VT_IP_ZAEHLER_PINDEX_PD inserted, PcbNr={0}, pruefix={1}", wm.SerialNr, max_Pruefindex);
}
}
///
/// Write results of one mechanical meter into the database
///
/// 0-based water meter number
/// Sorted list of results to save
void SaveMechanicalMeterToDB(OracleConnection conn, Results.Entities.WaterMeter wm, bool safeMode)
{
if (safeMode && !wm.Passed) return;
if (string.IsNullOrEmpty(wm.SerialNr)) return; /// No database activity possible w/o PCB number
int maxpruefindexLowPart = ReadMaxPruefindex(conn, wm);
TBF.BenchControl.GenericDevices.IBenchInfo benchInfo = TBF.BenchControl.Sequences.ProcessData.BenchInfo;
int testBenchID = (benchInfo != null) ? benchInfo.TestBenchId : 1;
int MAX_Pruefindex = 100 * testBenchID + maxpruefindexLowPart + 1;
int Hydr_Pruefung;
if (wm.Passed)
{
/// Passed
if (maxpruefindexLowPart == 0)
Hydr_Pruefung = 96;
else
Hydr_Pruefung = 224;
}
else
{
/// Failed
Hydr_Pruefung = 97; /// Hydr. test failed, Pressure test passed
}
wm.Pruefindex = MAX_Pruefindex;
wm.HydrPruefung = Hydr_Pruefung;
SaveOrUpdateMechanicalMeter(conn, wm, MAX_Pruefindex, Hydr_Pruefung);
}
void SaveOrUpdateMechanicalMeter(OracleConnection conn, Results.Entities.WaterMeter wm, int max_Pruefindex, int hydr_Pruefung)
{
int idBenutzer = 6; // = wm.Batch.UserNumber;
if (max_Pruefindex % 100 == 1)
{
if (!dbCfg.TestMode)
{
OracleCommand cmd = new OracleCommand("INSERT INTO VT_ZAEHLER_PD(Auftragsnummer, VT_Identnummer, VT_Fernum, Max_Pruefindex, MBUS_ADR, LIEGENSCHAFTS_NR, Sekundaere_Adr," +
" Hydr_Pruefung, MARK_DATE, Baujahr, EICH_JAHR, UMKARTON_NR, PALETTE_NR, ZAEHLERNUMMER, PREFIX, SUFFIX, Z_NR_KOMPLETT," +
" ANBID, ID_Benutzer) VALUES (:1, :2, :3, :4, :5, :6, :7, :8, :9, :10, :11, :12, :13, :14, :15, :16, :17, :18, :19)", conn);
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.PurchaseOrder }); /// :1
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = "88888888" }); /// :2
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr }); /// :3
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = max_Pruefindex }); /// :4
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :5 MBUS_ADR
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :6 LIEGENSCHAFTS_NR
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :7 Sekundaere_Adr
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = hydr_Pruefung }); /// :8
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.TimeStamp, Value = wm.Batch.EndTime }); /// :9
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = YearOfManufacture }); /// :10
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = YearOfManufacture }); /// :11
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :12 UMKARTON_NR
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :13 PALETTE_NR
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wm.AssignedSerialNr }); /// :14
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.Prefix }); /// :15
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.Suffix }); /// :16
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.CompleteSerialNr }); /// :17
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = Anbid_StaraTura }); /// :18
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = idBenutzer }); /// :19
cmd.ExecuteNonQuery();
log.InfoFormat("VT_ZAEHLER_PD inserted, PcbNr={0}, pos={1}, maxPruefix={2}", wm.SerialNr, wm.WMPosition, max_Pruefindex);
}
else
{
log.WarnFormat("SIM: VT_ZAEHLER_PD inserted, PcbNr={0}, pos={1}, maxPruefix={2}", wm.SerialNr, wm.WMPosition, max_Pruefindex);
}
}
else
{
if (!dbCfg.TestMode)
{
OracleCommand cmd = new OracleCommand("UPDATE VT_ZAEHLER_PD SET Auftragsnummer= :1, VT_Identnummer= :2, Max_Pruefindex= :3, MBUS_ADR= :4, LIEGENSCHAFTS_NR= :5," +
" Sekundaere_Adr= :6, Hydr_Pruefung= :7, MARK_DATE= :8, Baujahr= :9, EICH_JAHR= :10, UMKARTON_NR= :11, PALETTE_NR= :12," +
" ZAEHLERNUMMER= :13, PREFIX= :14, SUFFIX= :15, Z_NR_KOMPLETT= :16, ID_Benutzer= :17 WHERE VT_Fernum = :18 and ANBID = :19", conn);
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.PurchaseOrder }); /// :1
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = "88888888" }); /// :2
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = max_Pruefindex }); /// :3
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :4 MBUS_ADR
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :5 LIEGENSCHAFTS_NR
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :6 Sekundaere_Adr
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = hydr_Pruefung }); /// :7
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.TimeStamp, Value = wm.Batch.EndTime }); /// :8
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = YearOfManufacture }); /// :9
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = YearOfManufacture }); /// :10
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :11 UMKARTON_NR
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :12 PALETTE_NR
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wm.AssignedSerialNr }); /// :13
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.Prefix }); /// :14
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.Suffix }); /// :15
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.CompleteSerialNr }); /// :16
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = idBenutzer }); /// :17
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr }); /// :18
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = Anbid_StaraTura }); /// :19
cmd.ExecuteNonQuery();
log.InfoFormat("VT_ZAEHLER_PD updated, PcbNr={0}, pos={1}, maxPruefix={2}", wm.SerialNr, wm.WMPosition, max_Pruefindex);
}
else
{
log.WarnFormat("SIM: VT_ZAEHLER_PD updated, PcbNr={0}, pos={1}, maxPruefix={2}", wm.SerialNr, wm.WMPosition, max_Pruefindex);
}
}
if (!dbCfg.TestMode)
{
OracleCommand cmd = new OracleCommand("INSERT INTO VT_ZAEHLER_PINDEX_PD(" +
"VT_Fernum, Pruefindex, ANBID, ID_Pruefstand, ID_WzPruefreihe, Hydr_Pruefung, " +
"ReedKontakt, ReedKontaktOK, ReedKontaktZeit, KorrImprate, FestWertWZ, PtestOK, " +
"Zaehlerstand, WT_Platz_NR, WZgut, ID_Benutzer, AnzahlPruefungen)" +
" VALUES (:1, :2, :3, :4, :5, :6, 0, 0, 0, :7, 0, :8, 0, :9, :10, :11, :12)", conn); /// ReedKontakt = ReedKontaktOK = ReedKontaktZeit = FestWertWZ = Zaehlerstand = 0
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = max_Pruefindex });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = Anbid_StaraTura });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 18000 + wm.Batch.TestBenchId });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wm.Batch.BatchNr });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = hydr_Pruefung });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = wm.OrigCalibFactor });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// TODO
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wm.WMPosition });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wm.Passed ? 1 : 0 });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = idBenutzer });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 3 });
cmd.ExecuteNonQuery();
log.InfoFormat("VT_ZAEHLER_PINDEX_PD inserted, PcbNr={0}, pos={1}, pruefix={2}", wm.SerialNr, wm.WMPosition, max_Pruefindex % 100);
}
else
{
log.WarnFormat("SIM: VT_ZAEHLER_PINDEX_PD inserted, PcbNr={0}, pos={1}, pruefix={2}", wm.SerialNr, wm.WMPosition, max_Pruefindex % 100);
}
foreach (var testInfo in completeTestInfo)
{
if ((testInfo.PruefungsNrDB != 0) && (-20 <= testInfo.PruefungsNrDB) && (testInfo.PruefungsNrDB <= 20)) /// LU PruefungsNr-s are nonzero and between -20 and 20
{
Results.Entities.TestData tData = wm.GetTestData(testInfo.TestName);
Results.Entities.MeterTestRslt mtr;
if (tData == null)
{
throw new Exception(string.Format("'{0}' test results missing, watermeter {1}", testInfo.TestName, wm.WMPosition));
}
else if (tData.Repeats == 1)
{
mtr = wm.GetMeterTestRslt(testInfo.TestName);
if (mtr == null) throw new Exception(string.Format("'{0}' test results missing, watermeter {1}", testInfo.TestName, wm.WMPosition));
}
else
{
Results.Entities.MeterTestRslt firstMtr = wm.GetMeterTestRslt(Utils.TestTitle(tData, 1));
if (firstMtr == null) throw new Exception(string.Format("'{0}' test results missing, watermeter {1}", Utils.TestTitle(tData, 1), wm.WMPosition));
mtr = new Results.Entities.MeterTestRslt();
mtr.CopyContentFrom(firstMtr);
mtr.TestRslt = firstMtr.TestRslt;
mtr.WaterMeter = firstMtr.WaterMeter;
for (int i = 2; i <= tData.Repeats; i++)
{
Results.Entities.MeterTestRslt nextMtr = wm.GetMeterTestRslt(Utils.TestTitle(tData, i));
if (nextMtr == null) throw new Exception(string.Format("'{0}' test results missing, watermeter {1}", Utils.TestTitle(tData, i), wm.WMPosition));
mtr.TestTime += nextMtr.TestTime;
mtr.VolumeMeter += nextMtr.VolumeMeter;
mtr.VolumeRef += nextMtr.VolumeRef;
mtr.VolumeEnd = nextMtr.VolumeEnd;
mtr.Passed = (mtr.Passed && nextMtr.Passed);
}
mtr.Error = Formulas.ErrorFromVolumes(mtr.VolumeMeter, mtr.VolumeRef);
}
SaveMeterTestResult(conn, mtr, testInfo.PruefungsNrDB, max_Pruefindex, wmTypeRevision);
}
}
}
///
/// Saves a water meter result of a single test
///
/// q = 0, 1, 2 or 3 (Adj., Q1, Q2, Q3)
/// Nr. of rows updated
int SaveMeterTestResult(OracleConnection conn, Results.Entities.MeterTestRslt mtr, int pruefungsNr, int max_Pruefindex, int wmTypeRevision)
{
double Q_wm = (mtr.TestTime != 0) ? (3600.0 * mtr.VolumeMeter / mtr.TestTime) : 0; /// in [l/hour]
double Q_wm_with_upper_bound = Math.Min(2 * 1000 * mtr.TestRslt.FlowVolume, Math.Max(0.0, Q_wm));
int retv = 0;
if (!dbCfg.TestMode)
{
OracleCommand cmd = new OracleCommand("INSERT INTO VT_PRUEFREIHE_IST_PD(" +
"VT_Fernum, Pruefindex, PruefungsNr, ANBID, ID_WZTyp, Rev_WZTyp, Rev_WZPruefpunkt, " +
// :1 :2 :3 :4 :5 :6 :7
"Q_WZ, Q_Fehler, Q_Best, NIZ, AnfangZStand, EndZStand, " +
// :8 :9 :10 :11 :12 :13
"KorrErrQok, KorrErrQ, KorrQWz, TIZ, Vol_WZ_US, TempMittel_US)" +
// 0 :14 0 :15 0 0
" VALUES (:1, :2, :3, :4, :5, :6, :7, :8, :9, :10, :11, :12, :13, 0, :14, 0, :15, 0, 0)", conn);
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = mtr.WaterMeter.SerialNr }); /// :1
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = max_Pruefindex }); /// :2
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = pruefungsNr }); /// :3
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = Anbid_StaraTura }); /// :4
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = mtr.WaterMeter.WaterMeterData.WMTypeId }); /// :5
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wmTypeRevision }); /// :6
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 1 }); /// :7
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Q_wm_with_upper_bound }); /// :8
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Math.Min(100.0, Math.Max(-100.0, mtr.Error)) }); /// :9
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = mtr.Passed ? 1 : 0 }); /// :10
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :11
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Math.Max(-99999.999, Math.Min(mtr.VolumeStart, 99999.999)) }); /// :12
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Math.Max(-99999.999, Math.Min(mtr.VolumeEnd, 99999.999)) }); /// :13
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Math.Min(100.0, Math.Max(-100.0, mtr.KorrErrQ)) }); /// :14
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Math.Min(100000, mtr.TestTime) }); /// :15
retv = cmd.ExecuteNonQuery();
log.DebugFormat("VT_PRUEFREIHE_IST_PD inserted, PcbNr={0}, pruefungsNr={1}, error={2}", mtr.WaterMeter.SerialNr, pruefungsNr, mtr.Error);
}
else
{
log.WarnFormat("SIM: VT_PRUEFREIHE_IST_PD inserted, PcbNr={0}, pruefungsNr={1}, error={2}", mtr.WaterMeter.SerialNr, pruefungsNr, mtr.Error);
}
return retv;
}
#endif
}
}