/// /// Copyright (c) 2017 Sensus Metering Systems /// using System; using System.Collections.Generic; using log4net; using Config.Entities; using TBF.BenchControl; using TBF.BenchControl.GenericDevices; namespace TBF.BenchControl.DataEntry.StandardCamera { public class EntryForm : ComponentBase, IOperation, IDataEntryForCamera, IHasWMStatesForm, IHasCycleBeginForm, IHasCycleEndForm { private static readonly ILog log = LogManager.GetLogger(typeof(EntryForm)); public override string ToString() { return string.Format("DataEntry.Standard24({0})", Cfg.ToString(1)); } readonly EntryFormCfg entryFormCfg; IRegReader[] regReaders; public string[] StartImages { get { return startImages; } set { if (entryFormCfg.DebugLevel == DebugMode.Simulate) { startImages = new string[] { "C:\\TBF\\Images\\Test\\Image1.jpg", "C:\\TBF\\Images\\Test\\Image2.jpg", "C:\\TBF\\Images\\Test\\Image3.jpg", "C:\\TBF\\Images\\Test\\Image4.jpg", "C:\\TBF\\Images\\Test\\Image5.jpg", "C:\\TBF\\Images\\Test\\Image1.jpg", "C:\\TBF\\Images\\Test\\Image2.jpg", "C:\\TBF\\Images\\Test\\Image3.jpg", "C:\\TBF\\Images\\Test\\Image4.jpg", "C:\\TBF\\Images\\Test\\Image5.jpg", "C:\\TBF\\Images\\Test\\Image1.jpg", "C:\\TBF\\Images\\Test\\Image2.jpg", "C:\\TBF\\Images\\Test\\Image3.jpg", "C:\\TBF\\Images\\Test\\Image4.jpg", "C:\\TBF\\Images\\Test\\Image5.jpg", "C:\\TBF\\Images\\Test\\Image1.jpg", "C:\\TBF\\Images\\Test\\Image2.jpg", "C:\\TBF\\Images\\Test\\Image3.jpg", "C:\\TBF\\Images\\Test\\Image4.jpg", "C:\\TBF\\Images\\Test\\Image5.jpg" }; } else { startImages = value; } } } string[] startImages; public string[] EndImages { get { return endImages; } set { endImages = value; } } string[] endImages; public bool SaveImages { get { return entryFormCfg.SaveImages; } } /// /// Properties set by the Begin, End and WMStates form /// bool[] disabled; /// This array is shared between forms string[] wmCycleEndState; public string WMCycleEndState(int wmNr) { return (wmNr >= 0 && wmNr < wmCycleEndState.Length) ? wmCycleEndState[wmNr] : string.Empty; } double[] wmStartState; public double WMStartState(int wmNr) { return (wmNr >= 0 && wmNr < wmStartState.Length) ? wmStartState[wmNr] : 0; } double[] wmEndState; public double WMEndState(int wmNr) { return (wmNr >= 0 && wmNr < wmEndState.Length) ? wmEndState[wmNr] : 0; } string[] wmStartStateStr; System.Windows.Forms.Form modelessDlg; public bool Completed { get { return (modelessDlg is IHasCompleted) ? (modelessDlg as IHasCompleted).Completed : true; } } double refVolume; double errLimLo; double errLimHi; bool resultSaved; /// Set in Run() when results are saved IList waterMeters; /// Reference to ...ProcessData.BatchRslts.WaterMeters[] public enum CurrentOp { None, ShowFormAtCycleBeginning, ShowFormAtCycleEnd, TestStartStates, TestEndStates, DeferredTestEval, } CurrentOp currentOp; public EntryForm() { } public EntryForm(Generic.IComponentCfg cfg) : base(cfg) { entryFormCfg = cfg as EntryFormCfg; disabled = new bool[Config.Data.WMsCount]; wmStartState = new double[Config.Data.WMsCount]; wmStartStateStr = new string[Config.Data.WMsCount]; wmEndState = new double[Config.Data.WMsCount]; wmCycleEndState = new string[Config.Data.WMsCount]; currentOp = CurrentOp.None; log.Warn(this.ToString()); } /// Reference to the operation public IOperation ShowCycleBeginFormOp() { if (currentOp != CurrentOp.None) throw new Exception("Sequence error"); currentOp = CurrentOp.ShowFormAtCycleBeginning; this.waterMeters = TBF.BenchControl.Sequences.ProcessData.BatchRslts.Batch.WaterMeters; return this; } /// Reference to the operation public IOperation ShowCycleEndFormOp() { if (currentOp != CurrentOp.None) throw new Exception("Sequence error"); currentOp = CurrentOp.ShowFormAtCycleEnd; this.waterMeters = TBF.BenchControl.Sequences.ProcessData.BatchRslts.Batch.WaterMeters; return this; } /// Reference to the operation public IOperation ShowTestStartFormOp(IRegReader[] regReaders) { if (currentOp != CurrentOp.None) throw new Exception("Sequence error"); currentOp = CurrentOp.TestStartStates; this.regReaders = regReaders; return this; } /// Reference to the operation public IOperation ShowTestEndFormOp(IRegReader[] regReaders, double refVolume, double errLimLo, double errLimHi) { if (currentOp != CurrentOp.None) throw new Exception("Sequence error"); currentOp = CurrentOp.TestEndStates; this.regReaders = regReaders; this.refVolume = refVolume; this.errLimLo = errLimLo; this.errLimHi = errLimHi; return this; } /// Reference to the operation public IOperation ShowDeferredTestEvalFormOp(IRegReader[] regReaders, double refVolume, double errLimLo, double errLimHi) { if (currentOp != CurrentOp.None) throw new Exception("Sequence error"); currentOp = CurrentOp.DeferredTestEval; this.regReaders = regReaders; this.refVolume = refVolume; this.errLimLo = errLimLo; this.errLimHi = errLimHi; return this; } delegate void EntryFormDlgt(EntryForm myRef); /// void OpenBeginningDlg(EntryForm myRef) { myRef.modelessDlg = new CycleBeginningForm(Config.Data.WMsCount, entryFormCfg.HideOrder); modelessDlg.Show(); } /// void OpenEndDlg(EntryForm myRef) { if (!string.IsNullOrEmpty(entryFormCfg.ProtocolTitle1) || !string.IsNullOrEmpty(entryFormCfg.ProtocolTitle2) || !string.IsNullOrEmpty(entryFormCfg.ProtocolTitle3) || !string.IsNullOrEmpty(entryFormCfg.ProtocolTitle4)) { myRef.modelessDlg = new CycleEndFormMunich(Config.Data.WMsCount); (myRef.modelessDlg as CycleEndFormMunich).ProtocolName1 = entryFormCfg.ProtocolTitle1; (myRef.modelessDlg as CycleEndFormMunich).ProtocolName2 = entryFormCfg.ProtocolTitle2; (myRef.modelessDlg as CycleEndFormMunich).ProtocolName3 = entryFormCfg.ProtocolTitle3; (myRef.modelessDlg as CycleEndFormMunich).ProtocolName4 = entryFormCfg.ProtocolTitle4; } else { myRef.modelessDlg = new CycleEndForm(Config.Data.WMsCount, Config.Data.LineSize); } myRef.modelessDlg.Show(); } /// void OpenTestStartStatesDlg(EntryForm myRef) { myRef.modelessDlg = new TestStartEndForm(Config.Data.WMsCount, myRef.regReaders, startImages, disabled); modelessDlg.Show(); } /// void OpenTestEndStatesDlg(EntryForm myRef) { myRef.modelessDlg = new TestStartEndForm(Config.Data.WMsCount, myRef.regReaders, endImages, wmStartState, wmStartStateStr, disabled, refVolume, errLimLo, errLimHi); modelessDlg.Show(); } /// void OpenDeferredTestEvalDlg(EntryForm myRef) { myRef.modelessDlg = new TestStartEndForm(Config.Data.WMsCount, myRef.regReaders, startImages, endImages, disabled, refVolume, errLimLo, errLimHi); modelessDlg.Show(); } /// Start this operation public void Start() { resultSaved = false; switch (currentOp) { case CurrentOp.ShowFormAtCycleBeginning: if (!entryFormCfg.EnterSerialNrsAtTheEnd) { Program.MainWnd.Invoke(new EntryFormDlgt(OpenBeginningDlg), this); } break; case CurrentOp.ShowFormAtCycleEnd: if (entryFormCfg.EnterSerialNrsAtTheEnd) { Program.MainWnd.Invoke(new EntryFormDlgt(OpenBeginningDlg), this); } else if (entryFormCfg.ShowCycleEndForm) { Program.MainWnd.Invoke(new EntryFormDlgt(OpenEndDlg), this); } break; case CurrentOp.TestStartStates: Program.MainWnd.Invoke(new EntryFormDlgt(OpenTestStartStatesDlg), this); break; case CurrentOp.TestEndStates: Program.MainWnd.Invoke(new EntryFormDlgt(OpenTestEndStatesDlg), this); break; case CurrentOp.DeferredTestEval: Program.MainWnd.Invoke(new EntryFormDlgt(OpenDeferredTestEvalDlg), this); break; } } /// Run this operation /// Event.ResultsPrinted public Event Run() { if ((modelessDlg is IHasCompleted) && !(modelessDlg as IHasCompleted).Completed) { return Event.ModelessFormIsOpen; } if (!resultSaved) /// This is to save the result only once { if ((!entryFormCfg.EnterSerialNrsAtTheEnd && currentOp == CurrentOp.ShowFormAtCycleBeginning) || (entryFormCfg.EnterSerialNrsAtTheEnd && currentOp == CurrentOp.ShowFormAtCycleEnd)) { CycleBeginningForm dlg = (modelessDlg as CycleBeginningForm); if (dlg != null) { for (int i = 0; i < Math.Min(dlg.WaterMetersCount, waterMeters.Count); i++) { if (waterMeters[i] != null) { waterMeters[i].Disabled = disabled[i] = dlg.Disabled[i]; waterMeters[i].SerialNr = dlg.SNText[i]; if (!entryFormCfg.HideOrder && dlg.PurchaseOrder != null) waterMeters[i].PurchaseOrder = dlg.PurchaseOrder; } } } } else if (currentOp == CurrentOp.ShowFormAtCycleEnd) { if (modelessDlg is CycleEndForm) { CycleEndForm dlg = (modelessDlg as CycleEndForm); int count = waterMeters.Count; if ((dlg != null) && (count > dlg.WaterMetersCount)) count = dlg.WaterMetersCount; for (int i = 0; i < count; i++) { if (waterMeters[i] != null) { /// In case entryFormCfg.ShowCycleEndForm == false dlg would be null, values would be string.Empty wmCycleEndState[i] = waterMeters[i].EndState = (dlg != null) ? dlg.EndStateText[i] : string.Empty; } } } else if (modelessDlg is CycleEndFormMunich) { CycleEndFormMunich dlg = (modelessDlg as CycleEndFormMunich); Sequences.ProcessData.BatchRslts.Batch.ProtocolTitle = dlg.ProtocolTitle; for (int i = 0; i < Math.Min(waterMeters.Count, dlg.WaterMetersCount); i++) { if (waterMeters[i] != null) { wmCycleEndState[i] = waterMeters[i].EndState = dlg.EndStateText[i]; waterMeters[i].YearOfProduction = dlg.YearOfProduction[i]; } } } } else if (modelessDlg is TestStartEndForm && currentOp == CurrentOp.TestStartStates) { /// Fixed start/stop: test start TestStartEndForm dlg = (modelessDlg as TestStartEndForm); if (dlg != null) { for (int i = 0; i < dlg.WaterMetersCount; i++) { wmStartState[i] = dlg.WMStartState[i]; wmStartStateStr[i] = dlg.WMStartStateStr[i]; } } } else if (modelessDlg is TestStartEndForm && currentOp == CurrentOp.TestEndStates) { /// Fixed start/stop: test end TestStartEndForm dlg = (modelessDlg as TestStartEndForm); if (dlg != null) { for (int i = 0; i < dlg.WaterMetersCount; i++) { wmEndState[i] = dlg.WMEndState[i]; } } } else if (modelessDlg is TestStartEndForm && currentOp == CurrentOp.DeferredTestEval) { /// Fixed start/stop: deferred test evaluation TestStartEndForm dlg = (modelessDlg as TestStartEndForm); if (dlg != null) { for (int i = 0; i < dlg.WaterMetersCount; i++) { wmStartState[i] = dlg.WMStartState[i]; wmStartStateStr[i] = dlg.WMStartStateStr[i]; wmEndState[i] = dlg.WMEndState[i]; } } } resultSaved = true; modelessDlg = null; } return Event.ModelessFormClosed; /// Form closed } /// Stop this operation public void Stop() { if (modelessDlg is IHasCompleted) { UiBridge.Bridge.OnCloseModelessForm(this, null); modelessDlg = null; } currentOp = CurrentOp.None; } } }