/// Copyright (c) 2013-2015 Sensus Metering Systems
///
using System;
using System.Collections.Generic;
using log4net;
using TBF.BenchControl.GenericDevices;
namespace TBF.BenchControl.Elde.RegulValve
{
public class SetRegulValvePositionOp : IOperation
{
private static readonly ILog log = LogManager.GetLogger(typeof(SetRegulValvePositionOp));
public override string ToString()
{
return string.Format("SetRegulValvePositionOp({0},{1},{2})", regulValve.Name, posLoPct, posHiPct);
}
/// Set by the constructor
readonly ControlBoardDev controlBoard;
readonly RegulValve regulValve;
readonly int regulValveNr;
readonly float posLoPct;
readonly float posHiPct;
readonly int timeout;
/// Process values
bool firstRun;
int expireTime;
bool positionReached;
///
/// Set required water flow.
/// Events: FlowSet, FlowTimeOut
///
/// Control board device
/// Regulation valve component
/// Lower limit of the position to be achieved
/// Upper limit of the position to be achieved
/// Timeout in sec. for setting the flow
/// Only Elde.Valve flow are used, other flow on the lists are ignored
public SetRegulValvePositionOp(ControlBoardDev controlBoard, RegulValve regulValve, float posLoPct, float posHiPct, int timeout)
{
if (controlBoard == null) throw new ArgumentNullException("ctrlBoard");
this.controlBoard = controlBoard;
this.regulValve = regulValve as RegulValve;
if (regulValve == null) throw new ArgumentNullException("regValve is null or not Elde");
this.regulValveNr = this.regulValve.Idx1;
this.posLoPct = posLoPct;
this.posHiPct = posHiPct;
this.timeout = timeout;
log.Debug(this.ToString());
}
///
/// Set required water flow - no timeout.
/// Events: FlowSet
///
public SetRegulValvePositionOp(ControlBoardDev controlBoard, RegulValve regValve, float posLoPct, float posHiPct)
: this(controlBoard, regValve, posLoPct, posHiPct, int.MaxValue)
{
}
/// Start this operation
public void Start()
{
firstRun = true;
positionReached = false;
expireTime = StateMachine.Time + timeout;
log.InfoFormat("Start(): RV#={0}, reqPosLo={1}%, reqPosHi={2}%", regulValveNr, posLoPct.ToString("F1"), posHiPct.ToString("F1"));
}
/// Run this operation
///
/// Event.None . . . . . . . busy adjusting position
/// Event.PositionReached . . position reached
/// Event.OpArgumentError . . invalid required position
///
public Event Run()
{
if (firstRun)
{
if (posLoPct >= posHiPct || posLoPct >= 100.0f || posHiPct <= 0)
{
return Event.OpArgumentError;
}
firstRun = false;
controlBoard.ValveMove(regulValveNr,
RegulValveMode.TargetPosition,
new float[2] { posLoPct, posHiPct },
regulValve.StableTime);
return Event.None;
}
if (positionReached) return Event.PositionReached;
float positionPct = controlBoard.RValvePosition(regulValveNr);
log.WarnFormat("Run(): RV#={0}, actPos={1}%", regulValveNr, positionPct.ToString("F1"));
if (posLoPct >= posHiPct || posLoPct >= 100.0f || posHiPct <= 0)
{
return Event.OpArgumentError;
}
else if (posLoPct <= positionPct && positionPct <= posHiPct)
{
positionReached = true;
return Event.PositionReached;
}
else if (StateMachine.Time > expireTime)
{
return Event.RegulValveTimeOut;
}
else
{
return Event.None;
}
}
/// Stop this operation
public void Stop()
{
controlBoard.ValveMove(regulValveNr,
RegulValveMode.Stop,
new float[2] { posLoPct, posHiPct },
regulValve.StableTime);
}
}
}