/// /// Copyright (c) 2013-2015 Sensus Metering Systems /// using System.IO; using System.Collections.Generic; using System.IO.Ports; using System.Xml.Serialization; using TBF.BenchControl.Generic; namespace TBF.BenchControl.Danfoss.VLT2800 { public class PumpCfg : ComponentCfgBase, Generic.IComponentCfg { public IComponent GetComponent(IList components) { return new Pump(this, components); } public IComponentCfgCtrl GetControl() { return new PumpCfgCtrl(); } /// /// Serialized parameters /// public int Delay; // Delay of the pump function in [s] (affects the duration of transition sequence steps) public PumpProtocol Protocol; // Modbus or FC with Siemens address public int BitPosition; public int BusAddress; // Modbus or FC address in range 1..247 (Modbus) or 1..31 (FC with Siemens address) public int ComPortNr; public int BaudRate; public Parity Parity; public int DataBits; public StopBits StopBits; /// Private parameterless constructor invoked by all other (public) constructors PumpCfg() { Name = "Pump-Danfoss"; ParentName = string.Empty; Delay = 1; ComPortNr = 3; /// Default protocol settings (the same as Danfoss VLT2800 factory settings) Protocol = PumpProtocol.FC; BusAddress = 1; BaudRate = 9600; DataBits = 8; Parity = System.IO.Ports.Parity.Even; /// 'Parity.None' is the default value for Protocol = PumpProtocol.Modbus StopBits = System.IO.Ports.StopBits.One; } public PumpCfg(IComponentFactory factory) : this() { this.Factory = factory; } public string ToString(int i) { return string.Format("Name={0}, Delay={1}s, Protocol={2}, BusAddress={3}, Com{4}, {5}Bd, {6}-bits, parity={7}, stopBits={8}", Name, Delay, Protocol, BusAddress, ComPortNr, BaudRate, DataBits, Parity, StopBits); } } }