/// /// Copyright (c) 2018-2021 Sensus Slovensko a.s. /// using System; using System.Collections.Generic; using log4net; using Config; using TBF.Resources; using TBF.UiBridge; using TBF.Rig.GenericDevices; namespace TBF.Rig.TestMethods.FlyingStartMassCollProlonged { public class FlyingStartMassCollProlongedSeq : Sequences.SequenceBase { private static readonly ILog log = LogManager.GetLogger(typeof(FlyingStartMassCollProlongedSeq)); /// /// Check capabilities of devces in the output path required for this test method /// /// Devices /// true when capabilities of devices are OK public static bool CheckDeviceCaps(Config.Entities.Test test, OutputPath devices, out string message) { if (!(StateMachine.ControlBoard is ControlBoard.Uni.UniCB)) { /// Control board does not support this method message = string.Format("{0}: {1}", test.Name, Strings.Test_bench_does_not_suport_selected_test_method); return false; } if (!(devices.Scale is IScale)) { /// Scale is missing message = string.Format("{0}: {1}", test.Name, Strings.Missing_a_scale); return false; } if (!(devices.Diverter is IDiverter)) { /// Scale is missing message = string.Format("{0}: {1}", test.Name, Strings.Missing_a_diverter); return false; } if (!(devices.FlowMeter is IFlowMeter)) { /// Flow meter is missing message = string.Format("{0}: {1}", test.Name, Strings.Missing_a_flow_meter); return false; } if (!(devices.RegValve is GenericDevices.IRegValve)) { /// Regulation valve is missing message = string.Format("{0}: {1}", test.Name, Strings.Missing_a_regulation_valve); return false; } message = string.Empty; return true; } /// /// Flying start mass collection method sequence /// /// Test entity /// /// Event.Done . . . . . . . OK /// Event.UiCmdStop . . . . Stopped by the user using the on-screen button STOP /// Event.OpArgumentError . Target flow is out of range /// Event.Error . . . . . . Unspecified error /// public IList Execute(Config.Entities.Test test, int repetitionNr, bool isLastRepetition, Single.TestParams singleTestParams, Compound.TestParams compoundTestParams, HeatMeters.TestParams heatMetersTestParams, Config.Entities.DebugMode debugLevel) { if (debugLevel == Config.Entities.DebugMode.Simulate) { return Simulate(test, repetitionNr, isLastRepetition, singleTestParams, compoundTestParams, heatMetersTestParams); } ControlBoard.Uni.UniCB cBrd = StateMachine.ControlBoard as ControlBoard.Uni.UniCB; IScale scale = outPath.Scale as IScale; int rangeIx = 0; /// Default range, used for non-Elde flowmeters if (outPath.FlowMeter is Uni.FlowMeter.FlowMeter) { Uni.FlowMeter.FlowMeter eldeFM = outPath.FlowMeter as Uni.FlowMeter.FlowMeter; rangeIx = -1; /// Indicates invalid range for (int r = 0; r <= 5; r++) { if (eldeFM.RangeEnabled(r) && eldeFM.GetTempLo(r) <= test.TempLimLo && eldeFM.GetTempHi(r) >= test.TempLimHi) { rangeIx = r; } } if (rangeIx == -1) { Bridge.OnError(this, Strings.Flow_meter_temperature_range_does_not_fit_this_test_conditions); new List { Event.ConfigurationError }; } } float volumeToTank = (singleTestParams != null) ? singleTestParams.VolumeToTank : ((compoundTestParams != null) ? compoundTestParams.VolumeToTank : heatMetersTestParams.VolumeToTank); if (volumeToTank > scale.Capacity * Constants.TankFullFactor) { Bridge.OnError(this, Strings.Volume_to_tank_exceeds_the_scale_capacity); new List { Event.ConfigurationError }; } if (volumeToTank > test.Volume) { Bridge.OnError(this, Strings.Volume_to_tank_is_larger_then_the_test_volume); new List { Event.ConfigurationError }; } IList e = new List(); /// Events from currently running operations int tMass1 = 0; int tMass2 = 0; checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state processDataLoggingOp = new TBF.Rig.Operations.ProcessDataLoggingOp(processDataLogger, this, heatMetersTestParams != null); if (cBrd is ControlBoard.Uni.UniCB) { int[] filters = new int[] { 0, 0, 0, 0, 0, 0, 0, 0 }; if (sensPath != null && sensPath.RegisterReaders != null) { foreach (var rr in sensPath.RegisterReaders) { IRegReaderPulses rrPls = rr as IRegReaderPulses; if (rrPls != null && rrPls.Position >= 1 && rrPls.Position <= 8) { filters[rrPls.Position - 1] = rrPls.Filter; } } } (cBrd as ControlBoard.Uni.UniCB).SetFiltersPidShortPulses(filters, outPath.PidCoef, test.ShortPulses); } IList readTempPressOps = new List(); if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp)); if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown)); if (outPath.TempMtrDiv != null) readTempPressOps.Add(outPath.TempMtrDiv.ReadTempOp(ref TempDiv)); if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp)); if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown)); if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta)); if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1)); if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2)); if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1)); if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2)); Event retVal = Event.Done; LtrPerRefPulse = outPath.FlowMeter.LtrPerPulse; int targetTotalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f); int targetMassPulses = (int)(volumeToTank / LtrPerRefPulse + 0.5f); ///============================================================================================ /// Read pressure and temperature once before calling Bridge.OnTestSelected(...) State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name)) .AddOperation(checkUiOp) .AddOperations(readTempPressOps) .EnterState(); do { e = StateMachine.WaitRunDevsRunOps(); if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; } if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; } } while (e.Contains(Event.Busy)); /// Start the test, initialize test results Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath)); string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr); TestStartTime = DateTime.Now; foreach (var rr in sensPath.RegisterReaders) { GenericDevices.IHasTestName readerWithTstName = rr as GenericDevices.IHasTestName; if (readerWithTstName != null) { readerWithTstName.TestName = test.Name; readerWithTstName.TestRepeats = test.Repeats; readerWithTstName.RepetitionNr = repetitionNr; } } //------------------------------------------------ Bridge.OnActivity(this, Strings.Checking_tank_capacity); //------------------------------------------------ bool drainTheTank = test.DoDraining; if (!drainTheTank) /// If condition met => skip measuring and force emptying { /// /// Measure the weight and skip emptying if there is enough room in the tank /// State.Create(string.Format("{0}({1}) : Checking available tank capacity", test.Method, test.Name)) .AddOperation(checkUiOp) .AddOperations(readTempPressOps) .AddOperation(scale.ReadMassOp(ref Mass)) .EnterState(); do { e = StateMachine.WaitRunDevsRunOps(); if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; } if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; } } while (!e.Contains(Event.ScaleDone)); double estimatedEndMass = Mass.Val + volumeToTank; if (estimatedEndMass >= scale.Capacity * Constants.TankFullFactor) { drainTheTank = true; } } /// if (drainTheTank) { #if BERLIN switch (DrainTheTank(outPath.Scale)) { case Event.Error: { retVal = Event.Error; goto stopTest; } case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; } } drainTheTank = false; #else State.Create(string.Format("{0}({1}) : Open the drain valve", test.Method, test.Name)) .AddOperation(checkUiOp) .AddOperations(readTempPressOps) .AddOperation(cBrd.SetValvesOp(scale.DrainValve, null)) .EnterState(); do { e = StateMachine.WaitRunDevsRunOps(); if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; } if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; } } while (e.Contains(Event.ValvesBusy)); #endif } /// /// Optionally display prompt to emerge temperature meters to appropriate baths for heat meters test /// IOperation heatMetersPromptOp = null; if (heatMetersTestParams != null && !string.IsNullOrEmpty(heatMetersTestParams.Prompt)) { /// Make sure the CycleBeginForm is closed if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stopTest; heatMetersPromptOp = new Operations.MessageBoxOp(heatMetersTestParams.Prompt); } //------------------------------------------------ Bridge.OnActivity(this, Strings.Starting_the_pump); //------------------------------------------------ Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting)); int flowSetTime0 = StateMachine.Time; if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower); /// State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name)) .AddOperation(checkUiOp) // .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60)) .AddOperations(readTempPressOps) .AddOperation(heatMetersPromptOp) .AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null) .EnterState(); do { e = StateMachine.WaitRunDevsRunOps(); Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting)); Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting)); if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; } if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; } } while (e.Contains(Event.ValvesBusy) /* || !e.Contains(Event.AllPositionsReached)*/); if (test.TimePump2StartV > 0) { State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name)) .AddOperation(checkUiOp) .AddOperation(new Operations.TimerOp(test.TimePump2StartV)) .AddOperations(readTempPressOps) .AddOperation(heatMetersPromptOp) .EnterState(); do { e = StateMachine.WaitRunDevsRunOps(); Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting)); Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting)); if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; } } while (!e.Contains(Event.TimerExpired)); } if (benchPath.StopBFValve != null) { State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name)) .AddOperation(checkUiOp) .AddOperation(cBrd.SetValvesOp(benchPath.StopBFValve, null)) .AddOperations(readTempPressOps) .AddOperation(heatMetersPromptOp) .EnterState(); do { e = StateMachine.WaitRunDevsRunOps(); if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; } if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; } } while (!e.Contains(Event.ValvesSet)); } if (test.TimeBeforeFlow > 0) { State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name)) .AddOperation(checkUiOp) .AddOperation(new Operations.TimerOp(test.TimeBeforeFlow)) .AddOperations(readTempPressOps) .AddOperation(heatMetersPromptOp) .EnterState(); do { e = StateMachine.WaitRunDevsRunOps(); Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting)); Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting)); if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; } } while (!e.Contains(Event.TimerExpired)); } //------------------------------------------------ Bridge.OnActivity(this, Strings.Setting_the_flow); //------------------------------------------------ State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name)) .AddOperation(checkUiOp) .AddOperation(cBrd.SetFlowOp(test.Qfrom, test.Qto, RefFlow, FlowSettingTimeoutSec)) .AddOperations(readTempPressOps) .AddOperation(heatMetersPromptOp) .EnterState(); do { e = StateMachine.WaitRunDevsRunOps(); Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting)); Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting)); if (e.Contains(Event.OpArgumentError)) { retVal = Event.OpArgumentError; goto stopTest; } if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; } if (e.Contains(Event.RegulValveTimeOut)) { Bridge.OnError(this, Strings.Flow_adjustment_failed); retVal = Event.RecoverableError; goto stopTest; } if (e.Contains(Event.Next)) goto flow_set; } while (!e.Contains(Event.FlowReached)); flow_set: int flowSetTime = StateMachine.Time - flowSetTime0; double currentFlow = RefFlow.Val; if (heatMetersTestParams != null && heatMetersPath != null) { //--------------------------------------------------- Bridge.OnActivity(this, Strings.Setting_temperature); //--------------------------------------------------- int lastTimeSec = StateMachine.Time; double Tw_last = 0; double Tc_last = 0; State.Create(string.Format("{0}({1}) : Check temperature stabilized.", test.Method, test.Name)) .AddOperation(checkUiOp) .AddOperations(readTempPressOps) .AddOperation(heatMetersPromptOp) .EnterState(); do { e = StateMachine.WaitRunDevsRunOps(); if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; } if (e.Contains(Event.Next)) goto temperature_set; if (TempRefHi1.Val != 0 && TempRefHi2.Val != 0 && TempRefLo1.Val != 0 && TempRefLo2.Val != 0) { if (StateMachine.Time - lastTimeSec > 10 || StateMachine.Time - lastTimeSec < 0) { double Tw = (TempRefHi1.Val + TempRefHi2.Val) / 2; double Tc = (TempRefLo1.Val + TempRefLo2.Val) / 2; if (heatMetersTestParams.TempWarmLo <= Tw && Tw <= heatMetersTestParams.TempWarmHi && heatMetersTestParams.TempColdLo <= Tc && Tc <= heatMetersTestParams.TempColdHi && Math.Abs(Tw - Tw_last) <= heatMetersTestParams.ChangeInTimeWarm && Math.Abs(Tc - Tc_last) <= heatMetersTestParams.ChangeInTimeCold && Math.Abs(TempRefHi1.Val - TempRefHi2.Val) <= heatMetersTestParams.DeltaTempWarm && Math.Abs(TempRefLo1.Val - TempRefLo2.Val) <= heatMetersTestParams.DeltaTempCold) { goto temperature_set; } lastTimeSec = StateMachine.Time; Tw_last = Tw; Tc_last = Tc; } } } while (true); } else if (test.DoControlWaterTemp && benchPath.TempMtrUp != null && benchPath.TempMtrDown != null) { //--------------------------------------------------- Bridge.OnActivity(this, Strings.Setting_temperature); //--------------------------------------------------- State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name)) .AddOperation(checkUiOp) .AddOperations(readTempPressOps) .EnterState(); do { e = StateMachine.WaitRunDevsRunOps(); if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; } if (e.Contains(Event.Next)) goto temperature_set; if ((test.TempLimLo <= TempUp.Val) && (TempUp.Val <= test.TempLimHi) && (test.TempLimLo <= TempDown.Val) && (TempDown.Val <= test.TempLimHi)) { goto temperature_set; } } while (true); } temperature_set: /// /// Prepare cameras, ROI-s and measurementOperations /// /// Find successfully detected ROI-s IList rois = new List(); foreach (var rr in sensPath.RegisterReaders) { GenericDevices.IRegReaderLiveCamera cameraRoI = rr as GenericDevices.IRegReaderLiveCamera; if ((cameraRoI != null) && cameraRoI.Detected) { rois.Add(cameraRoI); } } /// Find cameras IList cameras = new List(); foreach (var roi in rois) { if (roi.Camera != null && !cameras.Contains(roi.Camera)) { cameras.Add(roi.Camera); roi.Camera.ClearRoiParams(); } } /// Register ROI-parameters to cameras foreach (var roi in rois) roi.RegisterRoiToCamera(); /// Prepare camera measurement operations IList cameraMeasurementOps = new List(); foreach (var camera in cameras) cameraMeasurementOps.Add(camera.MeasurementOp()); if (drainTheTank) { //------------------------------------------------ Bridge.OnActivity(this, Strings.Closing_the_tank); //------------------------------------------------ /// /// Make sure tank draining completed /// switch (DrainTheTank(scale, readTempPressOps)) { case Event.Error: { retVal = Event.Error; goto stopTest; } case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; } } drainTheTank = false; } else { /// Close the drain valve anyway State.Create(string.Format("{0}({1}) : Close the drain valve", test.Method, test.Name)) .AddOperation(checkUiOp) .AddOperations(readTempPressOps) .AddOperation(cBrd.SetValvesOp(null, scale.DrainValve)) .EnterState(); do { e = StateMachine.WaitRunDevsRunOps(); if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; } if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; } } while (e.Contains(Event.ValvesBusy)); } //------------------------------------------------ Bridge.OnActivity(this, Strings.Measuring_the_weight); //------------------------------------------------ LogProcessDataTestInfo(processDataLogger, test.Procedure.Name, test.Name); if (heatMetersPath == null) LogProcessDataHeader(processDataLogger, "Start mass"); else LogProcessDataHeaderHeatMeters(processDataLogger, "Start mass"); State.Create(string.Format("{0}({1}) : Measuring the start mass", test.Method, test.Name)) .AddOperation(checkUiOp) .AddOperations(readTempPressOps) .AddOperations(cameraMeasurementOps) .AddOperation(scale.ReadStableMassOp(ref StartMass, test.TimeFlow2Mass, test.MassMethod, test.MassRepeats, test.MassSpread)) .AddOperation(processDataLoggingOp) .EnterState(); do { e = StateMachine.WaitRunDevsRunOps(); if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; } if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; } if (e.Contains(Event.ScaleTimeout)) { Bridge.OnError(this, Strings.Mass_measurement_timeout); retVal = Event.RecoverableError; goto stopTest; } } while (!e.Contains(Event.ScaleDone)); Mass.Val = StartMass.Val; tMass1 = StateMachine.Time; log.WarnFormat("Start mass = {0}kg", StartMass); if (heatMetersPath == null) LogProcessDataHeader(processDataLogger, "Measurement"); else LogProcessDataHeaderHeatMeters(processDataLogger, "Measurement"); //------------------------------------------------ Bridge.OnActivity(this, Strings.Test_in_progress); //------------------------------------------------ /// Measurement loop preparation int estimtdEndTime = StateMachine.Time + (int)test.TestTime; StartNewStatistics(StateMachine.Time, BatchRslts.Batch.BatchNr, test.Name, repetitionNr, 0); DiverterStart.Start(BatchRslts.Batch.BatchNr, test.Name, repetitionNr); DiverterEnd.Start(BatchRslts.Batch.BatchNr, test.Name, repetitionNr); var prolongedTest = cBrd.FlyingStartStopTestOp(test, test.Qfrom, test.Qto, targetTotalPulses, true, true, targetMassPulses, true, DiverterStart, DiverterEnd); /// /// Measurement loop - 1st part /// State.Create(string.Format("{0}({1}) : 1st part of the test is running", test.Method, test.Name)) .AddOperation(checkUiOp) .AddOperations(readTempPressOps) .AddOperations(cameraMeasurementOps) .AddOperation(prolongedTest) .AddOperation(processDataLoggingOp) .EnterState(); do { e = StateMachine.WaitRunDevsRunOps(); if (e.Contains(Event.OpArgumentError)) { retVal = Event.OpArgumentError; goto stopTest; } if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; } if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; } DoInsideMeasurementLoop(cBrd, heatMetersTestParams, test, repetitionNr, estimtdEndTime); /// Proceed to 2nd part of the test when diverter turns back to sink, 'Next' button can be used in Debug version } while (!e.Contains(Event.TestPart2InProgress) && !e.Contains(Event.Next)); /// /// 2nd part of the test and simultaneous measurement the end mass /// State.Create(string.Format("{0}({1}) : Measuring the end mass", test.Method, test.Name)) .AddOperation(checkUiOp) .AddOperations(readTempPressOps) .AddOperations(cameraMeasurementOps) .AddOperation(prolongedTest) .AddOperation(scale.ReadStableMassOp(ref EndMass, test.TimeStop2Mass, test.MassMethod, test.MassRepeats, test.MassSpread)) .AddOperation(processDataLoggingOp) .EnterState(); do { e = StateMachine.WaitRunDevsRunOps(); if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; } if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; } if (e.Contains(Event.ScaleTimeout)) { Bridge.OnError(this, Strings.Mass_measurement_timeout); retVal = Event.RecoverableError; goto stopTest; } DoInsideMeasurementLoop(cBrd, heatMetersTestParams, test, repetitionNr, estimtdEndTime); /// Continue in 2nd part of the test when mass measurement is completed, 'Next' button can be used in Debug version } while (!e.Contains(Event.ScaleDone) && !e.Contains(Event.ScaleTimeout) && !e.Contains(Event.Next)); /// /// 2nd part of the test and optional opening of the drain valve /// State.Create(string.Format("{0}({1}) : 2nd part of the test is running", test.Method, test.Name)) .AddOperation(checkUiOp) .AddOperations(readTempPressOps) .AddOperations(cameraMeasurementOps) .AddOperation(prolongedTest) .AddOperation(test.DoDrainingAfter ? cBrd.SetValvesOp(scale.DrainValve, null) : null) .AddOperation(processDataLoggingOp) .EnterState(); do { e = StateMachine.WaitRunDevsRunOps(); if (e.Contains(Event.OpArgumentError)) { retVal = Event.OpArgumentError; goto stopTest; } if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; } if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; } DoInsideMeasurementLoop(cBrd, heatMetersTestParams, test, repetitionNr, estimtdEndTime); } while (!e.Contains(Event.TestCompleted) && !e.Contains(Event.Next)); StopRecordingStatistics(); /// /// (Berlin:) Water is stopped immediately after the test and before the 2nd mass measurement in case: /// - no 'transition sequence after test' is used /// - this is the last (or the only) test repetition or test is a part of an 'outer loop' /// if (isLastRepetition && transitionAfter == null) { if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOff(); State.Create("SequenceBase : Transition : TestEnd - Default action") .AddOperation(checkUiOp) .AddOperations(readTempPressOps) .AddOperation(cBrd.SetValvesOp(StateMachine.DefaultValvesOpen, StateMachine.DefaultValvesClose)) .EnterState(); do { e = StateMachine.WaitRunDevsRunOps(); if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; } if (TestAndLogUiCmdStop(e)) { retVal = Event.UiCmdStop; goto stopTest; } } while (!e.Contains(Event.ValvesSet)); } //------------------------------------------------ Bridge.OnActivity(this, Strings.Test_completed); //------------------------------------------------ /// Make sure the CycleBeginForm is closed so that water meter data (s/n) can be copied into results if (heatMetersPromptOp == null) { if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stopTest; } /// /// Populate TestResult data entity with data /// Results.Entities.TestRslt tstRslt = BatchRslts.GetTestRslt(testName, test.Part); if (tstRslt != null) { Results.Utils.GetCounterStates(tstRslt, Program.LocalSettings.Counters); UpdateTempPressDensAmb(tstRslt); double totalPulses = Convert.ToDouble(cBrd.RefPulses); double massPulses = Convert.ToDouble(cBrd.MassRefPulses); /// Main results tstRslt.MethodClass = TbfComponents.FindComponent(test.Method).ClassName; tstRslt.StartTime = TestStartTime; tstRslt.EndTime = TestEndTime; tstRslt.FlowSetTime = flowSetTime; tstRslt.TestTime = cBrd.TestTime; /// [s] measurement time (TODO: or cBrd.ImpulseTime(0) ???) tstRslt.TimeBtwnMassMsrmnts = tMass2 - tMass1; double massOfEvaporatedWater = (double)tstRslt.TimeBtwnMassMsrmnts * outPath.Scale.EvaporationRate(tstRslt.TempDivMean); tstRslt.PulsesMaster = massPulses; /// Pulses of the master flow meter (test total) tstRslt.TotalPulsesMstr = totalPulses; tstRslt.MassStartRaw = StartMass.Val; tstRslt.MassStart = Formulas.CorrectedValue(tstRslt.MassStartRaw, scale.Corrections); tstRslt.MassEndRaw = EndMass.Val; tstRslt.MassEnd = Formulas.CorrectedValue(tstRslt.MassEndRaw, scale.Corrections); tstRslt.FlowMass = 3600 * (tstRslt.MassEnd - tstRslt.MassStart + massOfEvaporatedWater) * totalPulses / (tstRslt.TestTime * massPulses); /// [kg/h] tstRslt.FlowVolume = 3.6 * LtrPerRefPulse * totalPulses / tstRslt.TestTime; /// [m3/h] tstRslt.Buoyancy = Formulas.Buoyancy(); tstRslt.VolumeCTV = 1000 * tstRslt.Buoyancy * (tstRslt.MassEnd - tstRslt.MassStart + massOfEvaporatedWater) / tstRslt.DensityLine; /// [l] commercially true volume of collected water if ((outPath.Diverter != null) && (tstRslt.TestTime > float.Epsilon)) { tstRslt.TestTimeCorrection = outPath.Diverter.TestTimeCorrection(tstRslt.FlowVolume); tstRslt.VolumeCTV *= tstRslt.TestTime + tstRslt.TestTimeCorrection; tstRslt.VolumeCTV /= tstRslt.TestTime; } tstRslt.VolumeMaster = LtrPerRefPulse * massPulses; /// [l] volume from the master flow meter tstRslt.ConstMasterRaw = outPath.FlowMeter.LtrPerPulse; /// Uncorrected master flowmeter coefficient tstRslt.ConstMasterCorr = outPath.FlowMeter.LtrPerPulseCorrected(tstRslt.FlowVolume, rangeIx); /// Master pulses per liter from a correction table and a flow tstRslt.ConstMaster = (massPulses != 0) ? (tstRslt.VolumeCTV / massPulses) : tstRslt.ConstMasterCorr; /// Master pulses per liter from the measured mass tstRslt.ErrorMaster = Formulas.ErrorFromVolumes(tstRslt.VolumeMaster, tstRslt.VolumeCTV); tstRslt.FlowMean = (float)RefFlowStat.Average; tstRslt.FlowStart = (float)RefFlowStat.First; tstRslt.FlowEnd = (float)RefFlowStat.Last; tstRslt.FlowMin = (float)RefFlowStat.Min; tstRslt.FlowMax = (float)RefFlowStat.Max; tstRslt.DiverterStart = outPath.Diverter.SwitchTimeStart.Val; tstRslt.DivStart10 = 0; tstRslt.DivStart50 = 0; tstRslt.DivStart90 = 0; tstRslt.DiverterEnd = outPath.Diverter.SwitchTimeEnd.Val; tstRslt.DivEnd90 = 0; tstRslt.DivEnd50 = 0; tstRslt.DivEnd10 = 0; log.DebugFormat("Diverter switch time [s]: Start: {0}ms ({1} {2} {3}) End: {4}ms ({5} {6} {7})", (tstRslt.DiverterStart * 1000).ToString("F0"), tstRslt.DivStart10, tstRslt.DivStart50, tstRslt.DivStart90, (tstRslt.DiverterEnd * 1000).ToString("F0"), tstRslt.DivEnd90, tstRslt.DivEnd50, tstRslt.DivEnd10); long infoFlags = 0; tstRslt.ErrorFlags = (ErrorFlagsComp != null) ? ErrorFlagsComp.GetErrorFlags(tstRslt, true, false, tstRslt.DiverterStart, tstRslt.DiverterEnd, out infoFlags) : 0; tstRslt.InfoFlags = infoFlags; if (compoundTestParams != null) { /// /// Compound meters /// for (int i = 0; i < BatchRslts.WMPositionsCount; i++) { if (!test.IsPartCompatible(Utils.PartNr(i + 1, BatchRslts.Batch.Compound))) continue; Results.Entities.MeterTestRslt mainMeterRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.CompoundMain); Results.Entities.MeterTestRslt auxMeterRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.CompoundAux); for (int isAux = 0; isAux <= 1; isAux++) /// 0=main, 1=aux { GenericDevices.IRegReader regReader = sensPath.RegisterReaders[2 * i + isAux]; Results.Entities.MeterTestRslt meterRslt = (isAux == 0) ? mainMeterRslt : auxMeterRslt; if (meterRslt != null && regReader != null) { meterRslt.RegReaderType = (int)regReader.RegisterReaderType; meterRslt.PulsesPerLiter = regReader.PulsesPerLtr; /// Optionally supress pulses from the large water meter meterRslt.PulsesMeter = (isAux == 0 && compoundTestParams.SupressTrills) ? 0 : Convert.ToDouble(regReader.WMPulses); meterRslt.PulsesMaster = Convert.ToDouble(regReader.WMRefPulses); meterRslt.TestTime = cBrd.TestTimeWM(regReader.Position); meterRslt.VolumeStart = 0; meterRslt.VolumeEnd = 0; meterRslt.VolumeRef = tstRslt.VolumeCTV; meterRslt.VolumeMeter = meterRslt.PulsesMeter * regReader.LtrsPerPulse; /// liter if (meterRslt.PulsesMaster != 0) { meterRslt.VolumeMeter *= (totalPulses / meterRslt.PulsesMaster); } meterRslt.Error = Formulas.ErrorFromVolumes(meterRslt.VolumeMeter, tstRslt.VolumeCTV); /// Main/Aux meter error is not usedfor evaluation } } Results.Entities.MeterTestRslt compoundMeterRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.Compound); if (compoundMeterRslt != null && mainMeterRslt != null && auxMeterRslt != null) { compoundMeterRslt.VolumeRef = tstRslt.VolumeCTV; compoundMeterRslt.VolumeMeter = mainMeterRslt.VolumeMeter + auxMeterRslt.VolumeMeter; compoundMeterRslt.PulsesMaster = totalPulses; compoundMeterRslt.TestTime = tstRslt.TestTime; compoundMeterRslt.Error = Formulas.ErrorFromVolumes(compoundMeterRslt.VolumeMeter, compoundMeterRslt.VolumeRef); compoundMeterRslt.Passed = (compoundMeterRslt.Error >= test.GetErrLimLo(tstRslt.VolumeCTV, tstRslt.TestTime) + test.Uncertainty) && (compoundMeterRslt.Error <= test.GetErrLimHi(tstRslt.VolumeCTV, tstRslt.TestTime) - test.Uncertainty) && (tstRslt.ErrorFlags == 0); mainMeterRslt.Passed = auxMeterRslt.Passed = compoundMeterRslt.Passed; mainMeterRslt.TestDone = auxMeterRslt.TestDone = compoundMeterRslt.TestDone = true; tstRslt.TestDone = true; } } } else if (heatMetersTestParams != null) { /// /// Heat meters /// tstRslt.RefEnergy = Energy.Sum * tstRslt.VolumeCTV / VolumeForEnergy.Sum; /// [J] = [J] * [l] / [l] tstRslt.Custom1 = (float)TempRefHiStat.Average; tstRslt.Custom2 = (float)TempRefHiStat.First; tstRslt.Custom3 = (float)TempRefHiStat.Last; tstRslt.Custom4 = (float)TempRefHiStat.Min; tstRslt.Custom5 = (float)TempRefHiStat.Max; tstRslt.Custom6 = (float)TempRefLoStat.Average; tstRslt.Custom7 = (float)TempRefLoStat.First; tstRslt.Custom8 = (float)TempRefLoStat.Last; tstRslt.Custom9 = (float)TempRefLoStat.Min; tstRslt.Custom10 = (float)TempRefLoStat.Max; for (int i = 0; i < BatchRslts.WMPositionsCount; i++) { if (!test.IsPartCompatible(Utils.PartNr(i + 1, BatchRslts.Batch.Compound))) continue; Results.Entities.MeterTestRslt volumeRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.HeatMeterVolume); Results.Entities.MeterTestRslt energyRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.HeatMeterEnergy); Rig.GenericDevices.IRegReader volumeRegReader = (sensPath.RegisterReaders.Length > 2 * i) ? sensPath.RegisterReaders[2 * i] : null; Rig.GenericDevices.IRegReader energyRegReader = (sensPath.RegisterReaders.Length > 2 * i + 1) ? sensPath.RegisterReaders[2 * i + 1] : null; if (volumeRslt != null && volumeRegReader != null) { volumeRslt.PulsesPerLiter = volumeRegReader.PulsesPerLtr; /// [l ^ -1] volumeRslt.PulsesMeter = Convert.ToDouble(volumeRegReader.WMPulses); volumeRslt.PulsesMaster = Convert.ToDouble(volumeRegReader.WMRefPulses); volumeRslt.VolumeStart = 0; volumeRslt.VolumeEnd = 0; volumeRslt.VolumeMeter = volumeRslt.PulsesMeter * volumeRegReader.LtrsPerPulse; /// [l] volumeRslt.VolumeRef = volumeRslt.PulsesMaster * tstRslt.ConstMaster; /// [l] volumeRslt.TestTime = cBrd.TestTimeWM(i + 1); /// [s] volumeRslt.Error = Formulas.ErrorFromVolumes(volumeRslt.VolumeMeter, volumeRslt.VolumeRef); volumeRslt.Passed = !heatMetersTestParams.EvaluateVolume || ((volumeRslt.Error >= test.GetErrLimLo(tstRslt.VolumeCTV, tstRslt.TestTime) + test.Uncertainty) && (volumeRslt.Error <= test.GetErrLimHi(tstRslt.VolumeCTV, tstRslt.TestTime) - test.Uncertainty) && (tstRslt.ErrorFlags == 0)); volumeRslt.TestDone = true; tstRslt.TestDone = true; } if (energyRslt != null && energyRegReader != null) { energyRslt.PulsesPerLiter = energyRegReader.PulsesPerLtr; /// [kWh ^ -1] energyRslt.PulsesMeter = Convert.ToDouble(energyRegReader.WMPulses); energyRslt.PulsesMaster = Convert.ToDouble(energyRegReader.WMRefPulses); energyRslt.VolumeStart = 0; energyRslt.VolumeEnd = 0; energyRslt.VolumeRef = tstRslt.RefEnergy * (energyRslt.PulsesMaster / totalPulses); /// [J] energyRslt.VolumeMeter = energyRslt.PulsesMeter * Config.Units.ConvertFrom(Config.Unit.kWh, energyRegReader.LtrsPerPulse); /// [J] energyRslt.TestTime = cBrd.TestTimeWM(i + 1); /// [s] energyRslt.Error = Formulas.ErrorFromVolumes(energyRslt.VolumeMeter, energyRslt.VolumeRef); energyRslt.Passed = (energyRslt.Error >= heatMetersTestParams.ErrorLimitLo) && (energyRslt.Error <= heatMetersTestParams.ErrorLimitHi) && (tstRslt.ErrorFlags == 0); energyRslt.TestDone = true; tstRslt.TestDone = true; } } } else { /// /// Single meters /// for (int i = 0; i < BatchRslts.WMPositionsCount; i++) { if (!test.IsPartCompatible(Utils.PartNr(i + 1, BatchRslts.Batch.Compound))) continue; /// MetersKind.Single meters Results.Entities.MeterTestRslt meterRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.Single); GenericDevices.IRegReader regReader = sensPath.RegisterReaders[i]; GenericDevices.IRegReaderDatastream dstrReader = regReader as GenericDevices.IRegReaderDatastream; TestMethods.iPerlCommunication.iPerlHead.IperlHead iPerl = regReader as TestMethods.iPerlCommunication.iPerlHead.IperlHead; GenericDevices.IRegReaderLiveCamera cameraRoi = regReader as GenericDevices.IRegReaderLiveCamera; if (meterRslt != null && regReader != null) { meterRslt.RegReaderType = (int)regReader.RegisterReaderType; meterRslt.PulsesPerLiter = regReader.PulsesPerLtr; meterRslt.PulsesMeter = Convert.ToDouble(regReader.WMPulses); log.DebugFormat("Water meter {0}: pulses/liter={1}, meter pulses={2}", i + 1, meterRslt.PulsesPerLiter, meterRslt.PulsesMeter); if (dstrReader != null) { meterRslt.TimestampStart = dstrReader.TimestampSecStart; meterRslt.TimestampEnd = !dstrReader.NoSamples ? dstrReader.TimestampSecEnd : (dstrReader.TimestampSecStart + tstRslt.TestTime); meterRslt.TestTime = meterRslt.TimestampEnd - meterRslt.TimestampStart; meterRslt.VolumeStart = dstrReader.VolumeLtrStart; /// liter meterRslt.VolumeEnd = dstrReader.VolumeLtrEnd; /// liter meterRslt.VolumeMeter = Math.Abs(dstrReader.VolumeLtrEnd - dstrReader.VolumeLtrStart); meterRslt.VolumeRef = tstRslt.VolumeCTV * meterRslt.TestTime * totalPulses / (tstRslt.TestTime * massPulses); meterRslt.PulsesMaster = totalPulses * meterRslt.TestTime / tstRslt.TestTime; if (iPerl != null) { if (iPerl.ResultCode != 0 && (meterRslt.WaterMeter.ResultCode & (int)Results.Entities.ResultCode.OptoErrorCodeMask) == 0) { meterRslt.WaterMeter.ResultCode |= iPerl.ResultCode; } #if IPERL meterRslt.WaterMeter.CalibFactor = iPerl.CalibFactor; #endif iPerl.LastTestResult2 = iPerl.LastTestResult; /// Save shift previous test result iPerl.LastTestResult = meterRslt; /// Save this test result } log.DebugFormat("Datastream: Tst={0} Tend={1} Tmtr={2} Ttime={3} Vst={4} Vend={5} Vmtr={6} Vref={7}", meterRslt.TimestampStart, meterRslt.TimestampEnd, meterRslt.TestTime, tstRslt.TestTime, meterRslt.VolumeStart, meterRslt.VolumeEnd, meterRslt.VolumeMeter, meterRslt.VolumeRef); } else if (cameraRoi != null) { meterRslt.TimestampStart = cameraRoi.TimestampStart; /// [s] meterRslt.TimestampEnd = cameraRoi.TimestampEnd; /// [s] meterRslt.TestTime = cameraRoi.TimestampEnd - cameraRoi.TimestampStart; /// [s] meterRslt.VolumeStart = cameraRoi.VolumeStart; /// [l] meterRslt.VolumeEnd = cameraRoi.VolumeEnd; /// [l] meterRslt.VolumeMeter = cameraRoi.VolumeEnd - cameraRoi.VolumeStart; /// [l] meterRslt.VolumeRef = tstRslt.VolumeCTV * meterRslt.TestTime * totalPulses / (tstRslt.TestTime * massPulses); meterRslt.PulsesMaster = totalPulses * meterRslt.TestTime / tstRslt.TestTime; log.DebugFormat("Camera: Tst={0} Tend={1} Tmtr={2} Ttime={3} Vst={4} Vend={5} Vmtr={6} Vref={7}", meterRslt.TimestampStart, meterRslt.TimestampEnd, meterRslt.TestTime, tstRslt.TestTime, meterRslt.VolumeStart, meterRslt.VolumeEnd, meterRslt.VolumeMeter, meterRslt.VolumeRef); } else { meterRslt.PulsesMaster = Convert.ToDouble(regReader.WMRefPulses); meterRslt.TestTime = cBrd.TestTimeWM(i + 1); meterRslt.VolumeStart = 0; /// [l] meterRslt.VolumeEnd = 0; /// [l] meterRslt.VolumeMeter = meterRslt.PulsesMeter * regReader.LtrsPerPulse; /// [l] meterRslt.VolumeRef = meterRslt.PulsesMaster * tstRslt.ConstMaster; /// [l], tstRslt.ConstMaster is calculated from massPulses and VolumeCTV (from scale) log.DebugFormat("Pulses: RefPls4mtrRR={0} Tmtr={1} Ttime={2} Vmtr={3} Vref={4}", meterRslt.PulsesMaster, meterRslt.TestTime, tstRslt.TestTime, meterRslt.VolumeMeter, meterRslt.VolumeRef); } meterRslt.Error = Formulas.ErrorFromVolumes(meterRslt.VolumeMeter, meterRslt.VolumeRef); meterRslt.Passed = (meterRslt.Error >= test.GetErrLimLo(tstRslt.VolumeCTV, tstRslt.TestTime) + test.Uncertainty) && (meterRslt.Error <= test.GetErrLimHi(tstRslt.VolumeCTV, tstRslt.TestTime) - test.Uncertainty) && (tstRslt.ErrorFlags == 0); meterRslt.TestDone = true; tstRslt.TestDone = true; } } } tstRslt.Components = Results.Entities.Components.UpdateList(BatchRslts.ComponentsList, new Results.Entities.Components((BenchInfo != null) ? BenchInfo.TestBenchId : 1, (BenchInfo != null) ? BenchInfo.TestBenchName : "testbench", inPath.Pump != null ? inPath.Pump.Name : string.Empty, outPath.FlowMeter != null ? outPath.FlowMeter.Name : string.Empty, scale != null ? scale.Name : string.Empty, outPath.RegValve != null ? outPath.RegValve.Name : string.Empty, outPath.Diverter != null ? outPath.Diverter.Name : string.Empty)); /// Update water meter error flags if (ErrorFlagsComp != null) { if (BatchRslts.Batch != null && BatchRslts.Batch.WaterMeters != null) { for (int i = 0; i < BatchRslts.WMPositionsCount; i++) { if (BatchRslts.Batch.WaterMeters[i] != null && !BatchRslts.Batch.WaterMeters[i].Disabled) { long wmInfoFlags; BatchRslts.Batch.WaterMeters[i].ErrorFlags = ErrorFlagsComp.GetWMtrErrorFlags(BatchRslts.Batch.WaterMeters[i].MeterTestRslts, out wmInfoFlags); BatchRslts.Batch.WaterMeters[i].InfoFlags = wmInfoFlags; } } } } /// Update results Bridge.OnTestCompleted(this, new TestCompletedEventArgs(testName, tstRslt)); } Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.TransitionAfter)); /// Append the results to the CSV-file allResults.Info(TestResult2CsvLine(testName, test.Part)); stopTest: StopRecordingStatistics(); /// /// Quit this sequence /// if (isLastRepetition || retVal == Event.UiCmdStop || retVal == Event.OpArgumentError || retVal == Event.Error || retVal == Event.ConfigurationError) { cBrd.Stop(false); } return new List { retVal }; } /// /// Collection of actions executed inside measurement loop /// void DoInsideMeasurementLoop(ControlBoard.IControlBoard cBrd, HeatMeters.TestParams heatMetersTestParams, Config.Entities.Test test, int repetitionNr, int estimtdEndTime, bool showRemainingTimeMsg = true) { RefFrequency.Val = cBrd.RefFrequency; RefFlow.Val = outPath.FlowMeter.ReadFlow(); UpdateAllStatistics(StateMachine.Time); UpdateEnergy(heatMetersTestParams); if (showRemainingTimeMsg) ShowRemainingTime(Math.Max(estimtdEndTime - StateMachine.Time, 0)); Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.Test)); Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test)); } /// /// This function is invoked in the measurement loop /// /// Heat meter test parameters or null void UpdateEnergy(HeatMeters.TestParams heatMetersTestParams) { if (heatMetersTestParams == null) return; if (lastEnergyUpdateTime == 0) { lastEnergyUpdateTime = StateMachine.Time; } else { //double deltaTime = (double)(StateMachine.Time - lastEnergyUpdateTime); double T_in = (TempRefHi1.Val + TempRefHi2.Val) / 2; /// [°C] double T_out = (TempRefLo1.Val + TempRefLo2.Val) / 2; /// [°C] double deltaVolume = LtrPerRefPulse * RefPulsesDelta; /// [l] double deltaEnergy = (0.001 * deltaVolume) * (T_in - T_out) * Formulas.HeatCoefficientWater(16, T_in, T_out, heatMetersTestParams.FlowMeasuredAtHiTempPipe); /// [J] = [m3] * [K] * [J/(m3 K)] Energy.Update(deltaEnergy); VolumeForEnergy.Update(deltaVolume); lastEnergyUpdateTime = StateMachine.Time; } } IList Simulate(Config.Entities.Test test, int repetitionNr, bool isLastRepetition, Single.TestParams singleTestParams, Compound.TestParams compoundTestParams, HeatMeters.TestParams heatMetersTestParams) { /// /// Test method simulation /// Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting)); if (compoundTestParams != null) { if (test.Name.ToLower().Contains("nok")) MakeSimulatedCompound(test, 1, 0, 4.7f, 0.9f); else MakeSimulatedCompound(test, 1, 0, 0.7f, 1.0f); } else if (heatMetersTestParams != null) { MakeSimulatedHeatMeters(test, 1, 0, 1.5f, 1000000, heatMetersTestParams.ErrorLimitLo, heatMetersTestParams.ErrorLimitHi, heatMetersTestParams.EvaluateVolume); } else { float errorPctBase = -1.0f; if (test.Name.ToLower().Contains("q3")) errorPctBase = -0.5f; else if (test.Name.ToLower().Contains("q2")) errorPctBase = 0.5f; else if (test.Name.ToLower().Contains("q1")) errorPctBase = -5.1f; MakeSimulated(test, repetitionNr, 0, errorPctBase + repetitionNr * 0.1f); } Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Completed)); Bridge.OnTestCompleted(this, new TestCompletedEventArgs(test.Name, BatchRslts.GetTestRslt(Results.Utils.GetTestName(test.Name, 1, 1), 0))); allResults.Info(TestResult2CsvLine(test.Name, 0)); /// Append the results to the CSV-file //------------------------------------------------------------------- Bridge.OnActivity(this, string.Format("{0} Simulation", test.Name)); //------------------------------------------------------------------- State.Create(string.Format("{0}({1}) : Simulation", test.Method, test.Name)) .AddOperation(checkUiOp) .EnterState(); IList e = StateMachine.WaitRunDevsRunOps(); return new List { TestAndLogUiCmdStop(test, e) ? Event.UiCmdStop : Event.Done }; } } }