///
/// Copyright (c) 2016-2020 Sensus slovensko a.s.
///
using System;
using System.Drawing;
using System.Windows.Forms;
using System.Collections.Generic;
using log4net;
using MySql.Data.MySqlClient;
using NHibernate;
using Results;
using Results.Entities;
using TBF.Resources;
using System.Text;
namespace TBF.UI.Settings
{
public partial class UpgradeSelectionDlg : Form
{
private static readonly ILog log = LogManager.GetLogger(typeof(UpgradeSelectionDlg));
int batchFrom;
int batchTo;
Shared.ModelessActivityForm form;
System.Threading.Thread formThread;
public UpgradeSelectionDlg()
{
InitializeComponent();
upgradeConfigDBCheckBox.Checked = true;
upgradeResultsDBCheckBox.Checked = true;
batchFrom = 1;
batchTo = Program.LocalSettings.BatchNr - 1;
textBox1.Text = batchFrom.ToString();
textBox2.Text = batchTo.ToString();
}
void ActivityStart()
{
form = new Shared.ModelessActivityForm()
{
Message = "Upgrading database",
FontFamily = "Arial",
FontSize = 24,
FontStyle = FontStyle.Regular,
BackgroundColor = Color.Green,
};
formThread = new System.Threading.Thread(() => form.ShowDialog());
formThread.Start();
}
void ActivityEnd()
{
if (form != null && formThread != null)
{
form.CloseForm(null, new EventArgs());
formThread.Join();
}
form = null;
formThread = null;
}
///
/// Common part of database upgrade code
///
/// Database connection
/// Array of SQL commands to be executed
/// true = successful
bool ExecuteCommands(MySqlConnection dbConn, string[] commands)
{
if (commands.Length == 0) return true;
bool success = false;
try
{
dbConn.Open();
foreach (var cmdText in commands)
{
MySqlCommand cmd = dbConn.CreateCommand();
cmd.CommandText = cmdText;
cmd.ExecuteNonQuery();
cmd.Dispose();
}
success = true;
}
catch (Exception exc)
{
log.ErrorFormat(string.Format("Exception when upgrading DB: {0}", exc.Message));
if (exc.InnerException != null) log.ErrorFormat(string.Format("Inner exception: {0}", exc.InnerException.Message));
ActivityEnd();
MessageBox.Show(string.Format("Exception {0}", exc.Message), "Error", MessageBoxButtons.OK, MessageBoxIcon.Exclamation);
}
finally
{
dbConn.Close();
}
return success;
}
///
/// Common part of database upgrade code
///
/// Database connection
/// Array of SQL commands to be executed
/// true = successful
bool ChangeErrorFlags(string errorFlagsCmpntName)
{
bool success = false;
ISession session = null;
try
{
session = TBF.DB.ConfigDBSessionFactory.OpenSession();
var testParams = session.QueryOver()
.Where(x => (x.CmpntName == errorFlagsCmpntName))
.List();
foreach (var tp in testParams)
{
string temp;
if (tp.Parameters.Contains("Info"))
{
temp = tp.Parameters.Replace("true", "1");
}
else if (tp.Parameters.Contains("On"))
{
temp = tp.Parameters.Replace("true", "2");
}
else
{
temp = tp.Parameters.Replace("true", "0");
}
tp.Parameters = temp.Replace("false", "0");
session.SaveOrUpdate(tp);
}
session.Flush();
session.Close();
success = true;
}
catch (Exception exc)
{
ActivityEnd();
MessageBox.Show(string.Format("Upgrade failed:\r\n{0}", exc.Message),
"Error", MessageBoxButtons.OK, MessageBoxIcon.Information);
}
finally
{
if (session != null) session.Close();
}
return success;
}
///---------------------------------------------------------------------
private void upgradeDb_NFC_button_Click(object sender, EventArgs e)
{
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
{
MessageBox.Show("No database selected");
return;
}
string[] commands = new string[]
{
"ALTER TABLE `user` ADD `Tag` VARCHAR(255) NULL DEFAULT NULL AFTER `Number`;",
};
ActivityStart();
if (!upgradeConfigDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(TBF.DB.CurrentBench.ProceduresDBSettings.ConnectionString), commands))
{
ActivityEnd();
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
upgradeDb_NFC_button.Enabled = false;
}
}
///---------------------------------------------------------------------
private void upgradeDb_24_29_Button_Click(object sender, EventArgs e)
{
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
{
MessageBox.Show("No database selected");
return;
}
string[] configDbCommands = new string[]
{
/// 2.4 -> 2.5
"ALTER TABLE `test` ADD `MassRepeats` INT NOT NULL DEFAULT '5' AFTER `PumpPower`, ADD `MassSpread` FLOAT NOT NULL DEFAULT '0' AFTER `MassRepeats`, ADD `MassMethod` TINYINT(3) UNSIGNED NOT NULL DEFAULT '0' AFTER `MassSpread`",
/// 2.5 -> 2.6 ---
/// 2.6 -> 2.7 ---
/// 2.7 -> 2.8 ---
/// 2.8 -> 2.9
"ALTER TABLE `meterspath` DROP `Qfrom`, DROP `Qto`;",
};
string[] resultsDbCommands = new string[]
{
/// 2.4 -> 2.5 ---
/// 2.5 -> 2.6
"ALTER TABLE `watermeterdata` DROP `Q3`, CHANGE `Qn` `Q3_Qn` DOUBLE NULL DEFAULT NULL ",
"ALTER TABLE `watermeterdata` ADD `DN` DOUBLE NOT NULL DEFAULT '0' AFTER `Producer`, ADD `L` DOUBLE NOT NULL DEFAULT '0' AFTER `DN`, ADD `Mounting` VARCHAR(255) NULL DEFAULT NULL AFTER `L`, ADD `TemperatureClass` VARCHAR(255) NULL DEFAULT NULL AFTER `Q1_Qmin`, ADD `PressureLossClass` VARCHAR(255) NULL DEFAULT NULL AFTER `TemperatureClass`",
"ALTER TABLE `watermeterdata` ADD `MaxAdmissiblePressure` VARCHAR(255) NULL DEFAULT NULL AFTER `PressureLossClass`, ADD `FlowProfileSensitivityClass` VARCHAR(255) NULL DEFAULT NULL AFTER `MaxAdmissiblePressure`, ADD `Certificate` VARCHAR(255) NULL DEFAULT NULL AFTER `FlowProfileSensitivityClass`, ADD `PulsesPerLtr` DOUBLE NOT NULL DEFAULT '1' AFTER `Certificate`",
"ALTER TABLE `watermeterdata` ADD `Text1` VARCHAR(255) NULL DEFAULT NULL AFTER `PulsesPerLtr`, ADD `Text2` VARCHAR(255) NULL DEFAULT NULL AFTER `Text1`, ADD `Text3` VARCHAR(255) NULL DEFAULT NULL AFTER `Text2`, ADD `Text4` VARCHAR(255) NULL DEFAULT NULL AFTER `Text3`, ADD `Text5` VARCHAR(255) NULL DEFAULT NULL AFTER `Text4`",
/// 2.6 -> 2.7
"ALTER TABLE `watermeterdata` ADD `ProducerAux` VARCHAR(255) NULL DEFAULT NULL AFTER `PulsesPerLtr`, ADD `Q3_Qn_Aux` DOUBLE NOT NULL DEFAULT '0' AFTER `ProducerAux`, ADD `MetrologicalClassAux` VARCHAR(255) NULL DEFAULT NULL AFTER `Q3_Qn_Aux`, ADD `ApprovalInfoAux` VARCHAR(255) NULL DEFAULT NULL AFTER `MetrologicalClassAux`",
/// 2.7 -> 2.8
"ALTER TABLE `watermeter` ADD `ResultCode` INT NOT NULL DEFAULT '0' AFTER `Passed`",
"ALTER TABLE `batch` ADD `Remark` VARCHAR( 2000 ) NULL DEFAULT NULL AFTER `ProtocolTitle`",
/// 2.8 -> 2.9 ---
};
ActivityStart();
if ((!upgradeConfigDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(TBF.DB.CurrentBench.ProceduresDBSettings.ConnectionString), configDbCommands)) &&
(!upgradeResultsDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(Results.DB.ConnectionString), resultsDbCommands)))
{
ActivityEnd();
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
upgradeDb_24_29_Button.Enabled = false;
}
}
///---------------------------------------------------------------------
private void upgradeDb_29_212_Button_Click(object sender, EventArgs e)
{
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
{
MessageBox.Show("No database selected");
return;
}
string[] configDbCommands = new string[]
{
/// 2.9 -> 2.10
/// 2.10 -> 2.11
"ALTER TABLE `feedingpath` ADD `RegulValvesPct` VARCHAR(255) NULL DEFAULT NULL AFTER `Pump;",
/// 2.11 -> 2.12
"ALTER TABLE `benchpath` ADD `PressMtrDelta` VARCHAR(255) NULL DEFAULT NULL AFTER `PressOut;",
};
string[] resultsDbCommands = new string[]
{
/// 2.9 -> 2.10
"ALTER TABLE `testrslt` ADD `AmbTempStart` FLOAT NOT NULL DEFAULT '0' AFTER `AmbientTempAve`",
"ALTER TABLE `testrslt` ADD `AmbTempEnd` FLOAT NOT NULL DEFAULT '0' AFTER `AmbTempStart`",
"ALTER TABLE `testrslt` ADD `AmbTempMin` FLOAT NOT NULL DEFAULT '0' AFTER `AmbTempEnd`",
"ALTER TABLE `testrslt` ADD `AmbTempMax` FLOAT NOT NULL DEFAULT '0' AFTER `AmbTempMin`",
"ALTER TABLE `testrslt` ADD `AmbPressStart` FLOAT NOT NULL DEFAULT '0' AFTER `AmbientPressAve`",
"ALTER TABLE `testrslt` ADD `AmbPressEnd` FLOAT NOT NULL DEFAULT '0' AFTER `AmbPressStart`",
"ALTER TABLE `testrslt` ADD `AmbPressMin` FLOAT NOT NULL DEFAULT '0' AFTER `AmbPressEnd`",
"ALTER TABLE `testrslt` ADD `AmbPressMax` FLOAT NOT NULL DEFAULT '0' AFTER `AmbPressMin`",
"ALTER TABLE `testrslt` ADD `AmbHumiStart` FLOAT NOT NULL DEFAULT '0' AFTER `AmbientHumiAve`",
"ALTER TABLE `testrslt` ADD `AmbHumiEnd` FLOAT NOT NULL DEFAULT '0' AFTER `AmbHumiStart`",
"ALTER TABLE `testrslt` ADD `AmbHumiMin` FLOAT NOT NULL DEFAULT '0' AFTER `AmbHumiEnd`",
"ALTER TABLE `testrslt` ADD `AmbHumiMax` FLOAT NOT NULL DEFAULT '0' AFTER `AmbHumiMin`",
/// 2.10 -> 2.11
/// 2.11 -> 2.12
"ALTER TABLE `testrslt` ADD `PressDeltaMean` FLOAT NOT NULL DEFAULT '0' AFTER `PressDownMax`",
"ALTER TABLE `testrslt` ADD `PressDeltaStart` FLOAT NOT NULL DEFAULT '0' AFTER `PressDeltaMean`",
"ALTER TABLE `testrslt` ADD `PressDeltaEnd` FLOAT NOT NULL DEFAULT '0' AFTER `PressDeltaStart`",
"ALTER TABLE `testrslt` ADD `PressDeltaMin` FLOAT NOT NULL DEFAULT '0' AFTER `PressDeltaEnd`",
"ALTER TABLE `testrslt` ADD `PressDeltaMax` FLOAT NOT NULL DEFAULT '0' AFTER `PressDeltaMin`",
"ALTER TABLE `testrslt` ADD `FlowStart` FLOAT NOT NULL DEFAULT '0' AFTER `TempDivMax`",
"ALTER TABLE `testrslt` ADD `FlowEnd` FLOAT NOT NULL DEFAULT '0' AFTER `FlowStart`",
};
ActivityStart();
if ((!upgradeConfigDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(TBF.DB.CurrentBench.ProceduresDBSettings.ConnectionString), configDbCommands)) &&
(!upgradeResultsDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(Results.DB.ConnectionString), resultsDbCommands)))
{
if (upgradeConfigDBCheckBox.Checked)
{
MySqlConnection dbConn = new MySqlConnection(TBF.DB.CurrentBench.ProceduresDBSettings.ConnectionString);
try
{
dbConn.Open();
MySqlCommand cmd;
cmd = dbConn.CreateCommand();
cmd.CommandText = "UPDATE component SET ClassName = 'TestMethods.Adjustment.Single' WHERE ClassName = 'Adjustment'";
cmd.ExecuteNonQuery();
cmd.Dispose();
cmd = dbConn.CreateCommand();
cmd.CommandText = "UPDATE component SET ClassName = 'TestMethods.FlyingStartMassCollection.Compound' WHERE ClassName = 'CombinedMeters'";
cmd.ExecuteNonQuery();
cmd.Dispose();
cmd = dbConn.CreateCommand();
cmd.CommandText = "UPDATE component SET ClassName = 'TestMethods.CombinedWithDetection.Compound' WHERE ClassName = 'CombinedWithDetection'";
cmd.ExecuteNonQuery();
cmd.Dispose();
cmd = dbConn.CreateCommand();
cmd.CommandText = "UPDATE component SET ClassName = 'TestMethods.FixedStartMassCollection.Single' WHERE ClassName = 'FixedStartMassCollection'";
cmd.ExecuteNonQuery();
cmd.Dispose();
cmd = dbConn.CreateCommand();
cmd.CommandText = "UPDATE component SET ClassName = 'TestMethods.FixedStartMassCollection.Compound' WHERE ClassName = 'FixedStartCombinedMeters'";
cmd.ExecuteNonQuery();
cmd.Dispose();
cmd = dbConn.CreateCommand();
cmd.CommandText = "UPDATE component SET ClassName = 'TestMethods.FlyingStart.Single' WHERE ClassName = 'FlyingStart'";
cmd.ExecuteNonQuery();
cmd.Dispose();
cmd = dbConn.CreateCommand();
cmd.CommandText = "UPDATE component SET ClassName = 'TestMethods.FlyingStartMassCollection.Single' WHERE ClassName = 'Flying-Start-Collection'";
cmd.ExecuteNonQuery();
cmd.Dispose();
cmd = dbConn.CreateCommand();
cmd.CommandText = "UPDATE component SET ClassName = 'TestMethods.LeakTest' WHERE ClassName = 'Leak-Test'";
cmd.ExecuteNonQuery();
cmd.Dispose();
cmd = dbConn.CreateCommand();
cmd.CommandText = "UPDATE component SET ClassName = 'TestMethods.PMaxTest' WHERE ClassName = 'PMax-Test'";
cmd.ExecuteNonQuery();
cmd.Dispose();
cmd = dbConn.CreateCommand();
cmd.CommandText = "UPDATE component SET ClassName = 'Output.Printers.Enhanced.Single' WHERE ClassName = 'BasicResultsPrinter'";
cmd.ExecuteNonQuery();
cmd.Dispose();
ActivityEnd();
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
upgradeDb_29_212_Button.Enabled = false;
}
catch (Exception exc)
{
log.ErrorFormat(string.Format("Exception when upgrading DB: {0}", exc.Message));
if (exc.InnerException != null) log.ErrorFormat(string.Format("Inner exception: {0}", exc.InnerException.Message));
ActivityEnd();
MessageBox.Show(string.Format("Exception {0}", exc.Message), "Error", MessageBoxButtons.OK, MessageBoxIcon.Exclamation);
}
finally
{
dbConn.Close();
}
}
else
{
ActivityEnd();
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
upgradeDb_29_212_Button.Enabled = false;
}
}
}
///---------------------------------------------------------------------
private void upgradeDb_212_215_Button_Click(object sender, EventArgs e)
{
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
{
MessageBox.Show("No database selected");
return;
}
string[] configDbCommands = new string[]
{
/// 2.12 -> 2.13
"ALTER TABLE `procedure` ADD `Protected` BOOLEAN NOT NULL DEFAULT '0' AFTER `ProtocolTitle`, ADD `MustBeComplete` BOOLEAN NOT NULL DEFAULT '0' AFTER `Protected`, ADD `ManualCtrlDisabled` BOOLEAN NOT NULL DEFAULT '0' AFTER `MustBeComplete`",
/// 2.13 -> 2.14
"ALTER TABLE `test` ADD `DoControlWaterTemp` BOOLEAN NOT NULL DEFAULT '0' AFTER `Zeroing`, ADD `TempLimLo` FLOAT NOT NULL DEFAULT '15' AFTER `DoControlWaterTemp`, ADD `TempLimHi` FLOAT NOT NULL DEFAULT '25' AFTER `TempLimLo`",
/// 2.14 -> 2.15
"ALTER TABLE `procedure` ADD `AltProcName` VARCHAR(255) NULL DEFAULT NULL , ADD `AltProcPeriod` INT NOT NULL DEFAULT '0';",
//"ALTER TABLE `procedure` DROP `ProtocolTitle`;", /// Commented out to maintain compatibility with an old ResultsBrowser
};
string[] resultsDbCommands = new string[]
{
/// 2.12 -> 2.13
"ALTER TABLE `watermeter` ADD `Remark` VARCHAR( 2000 ) NULL DEFAULT NULL AFTER `ResultCode`",
"ALTER TABLE `batch` ADD `Dirty` BOOLEAN NOT NULL DEFAULT '0' AFTER `EndTime`",
/// 2.13 -> 2.14
#if !IPERL
"ALTER TABLE `testrslt` ADD `FlowMean` FLOAT NOT NULL DEFAULT '0' AFTER `TempDivMax`",
#endif
"ALTER TABLE `testrslt` ADD `TestDone` BOOLEAN NOT NULL DEFAULT '1' AFTER `RepetitionNr`, ADD `Remark` VARCHAR( 2000 ) NULL DEFAULT NULL AFTER `TestDone`",
"ALTER TABLE `testdata` ADD `DoControlWaterTemp` BOOLEAN NOT NULL DEFAULT '0' AFTER `Uncertainty`, ADD `TempLimLo` FLOAT NOT NULL DEFAULT '15' AFTER `DoControlWaterTemp`, ADD `TempLimHi` FLOAT NOT NULL DEFAULT '25' AFTER `TempLimLo`",
/// 2.14 -> 2.15
"ALTER TABLE `watermeter` ADD `ArchivePath` VARCHAR(255) NULL DEFAULT NULL AFTER `ResultCode`;",
};
ActivityStart();
if ((!upgradeConfigDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(TBF.DB.CurrentBench.ProceduresDBSettings.ConnectionString), configDbCommands)) &&
(!upgradeResultsDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(Results.DB.ConnectionString), resultsDbCommands)))
{
if (upgradeConfigDBCheckBox.Checked)
{
MySqlConnection dbConn = new MySqlConnection(TBF.DB.CurrentBench.ProceduresDBSettings.ConnectionString);
try
{
dbConn.Open();
int maxItemNr = 0;
MySqlCommand cmd = dbConn.CreateCommand();
cmd.CommandText = "SELECT ItemNr FROM component";
MySqlDataReader dr = cmd.ExecuteReader();
while (dr.Read())
{
int itemNr = dr.GetInt32(0);
if (itemNr > maxItemNr) maxItemNr = itemNr;
}
dr.Close();
cmd = dbConn.CreateCommand();
cmd.CommandText = "UPDATE component SET ClassName = 'RegisterReader for standing start/stop' WHERE ClassName = 'Fixed-Start-Register-Reader'";
cmd.ExecuteNonQuery();
cmd.Dispose();
cmd = dbConn.CreateCommand();
cmd.CommandText = "UPDATE component SET ClassName = 'TestMethods.iPerlCommunication' WHERE ClassName = 'iPerlCommunication'";
cmd.ExecuteNonQuery();
cmd.Dispose();
cmd = dbConn.CreateCommand();
cmd.CommandText = "UPDATE component SET ClassName = 'WaterMeter' WHERE ClassName = 'iPerl'";
cmd.ExecuteNonQuery();
cmd.Dispose();
for (int i = 1; i <= 40; i++)
{
Text = string.Format("Upgrade selection: {0}/40", i);
/// Read original iPerl water meter parameters
int id = 0;
string parameters = string.Empty;
cmd = dbConn.CreateCommand();
cmd.CommandText = string.Format("SELECT Id, Parameters FROM Component WHERE Name = 'iPerl{0}' AND ClassName = 'WaterMeter'", i);
dr = cmd.ExecuteReader();
if (dr.Read())
{
id = dr.GetInt32(0);
parameters = dr.GetString(1);
}
dr.Close();
cmd.Dispose();
if (id != 0)
{
/// Rename iPerl water meter
cmd = dbConn.CreateCommand();
cmd.CommandText = string.Format("UPDATE component SET Name = 'WM{0}' WHERE Name = 'iPerl{0}'", i);
cmd.ExecuteNonQuery();
cmd.Dispose();
/// Create iPerl Head
cmd = dbConn.CreateCommand();
cmd.CommandText = string.Format("INSERT INTO component(ItemNr, Name, ClassName, Parentname, Mode, Logging, Parameters) VALUES ({0}, 'iPerl{1}', 'RegisterReader for iPerl', '', 'Normal', 'Off', @params)",
maxItemNr + 1, i);
cmd.Parameters.AddWithValue("@params", parameters.Replace("WaterMeterCfg", "IperlHeadCfg"));
cmd.ExecuteNonQuery();
cmd.Dispose();
/// Clone procedure parameters
IList idList = new List();
IList parList = new List();
IList procIdList = new List();
cmd = dbConn.CreateCommand();
cmd.CommandText = string.Format("SELECT Id, Parameters, Procedure_id FROM componentprocedure WHERE CmpntName = 'iPerl{0}'", i);
dr = cmd.ExecuteReader();
while (dr.Read())
{
idList.Add(dr.GetInt32(0));
parList.Add(dr.GetString(1));
procIdList.Add(dr.GetInt32(2));
}
dr.Close();
cmd.Dispose();
if ((idList.Count == parList.Count) && (parList.Count == procIdList.Count))
{
for (int j = 0; j < parList.Count; j++)
{
cmd = dbConn.CreateCommand();
cmd.CommandText = string.Format("INSERT INTO componentprocedure(CmpntName, Parameters, Procedure_id) VALUES ('WM{0}', @params, {1})",
i, procIdList[j]);
cmd.Parameters.AddWithValue("@params", parList[j].Replace("Q4", "Qmax")
.Replace("Q3", "Qn")
.Replace("Q2", "Qt")
.Replace("Q1", "Qmin")
.Replace("", "true\r\n "));
cmd.ExecuteNonQuery();
cmd.Dispose();
}
}
}
}
/// Delete 'Parmeters' of iPerl water meters
cmd = dbConn.CreateCommand();
cmd.CommandText = "UPDATE component SET Parameters = '\r\n\r\n' WHERE ClassName = 'WaterMeter'";
cmd.ExecuteNonQuery();
cmd.Dispose();
Text = string.Format("Upgrade selection");
ActivityEnd();
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
upgradeDb_212_215_Button.Enabled = false;
}
catch (Exception exc)
{
log.ErrorFormat(string.Format("Exception when upgrading DB: {0}", exc.Message));
if (exc.InnerException != null) log.ErrorFormat(string.Format("Inner exception: {0}", exc.InnerException.Message));
ActivityEnd();
MessageBox.Show(string.Format("Exception {0}", exc.Message), "Error", MessageBoxButtons.OK, MessageBoxIcon.Exclamation);
}
finally
{
dbConn.Close();
}
}
else
{
ActivityEnd();
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
upgradeDb_212_215_Button.Enabled = false;
}
}
}
///---------------------------------------------------------------------
private void upgradeDb_215_216_Button_Click(object sender, EventArgs e)
{
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
{
MessageBox.Show("No database selected");
return;
}
string[] commands = new string[]
{
"ALTER TABLE `testrslt` ADD `ErrorFlagsMd` TINYINT( 4 ) NOT NULL DEFAULT '0' AFTER `ErrorMaster`," +
" ADD `ErrorFlags` INT NOT NULL DEFAULT '0' AFTER `ErrorFlagsMd`;",
};
ActivityStart();
if (!upgradeResultsDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(Results.DB.ConnectionString), commands))
{
ActivityEnd();
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
upgradeDb_215_216_Button.Enabled = false;
}
}
///---------------------------------------------------------------------
private void upgradeDb_216_217_Button_Click(object sender, EventArgs e)
{
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
{
MessageBox.Show("No database selected");
return;
}
string[] commands = new string[]
{
"ALTER TABLE `testrslt` ADD `DiverterStart` FLOAT NOT NULL DEFAULT '0.001' AFTER `ErrorMaster`," +
" ADD `DiverterEnd` FLOAT NOT NULL DEFAULT '0.001' AFTER `DiverterStart`;",
"ALTER TABLE `watermeter` ADD `ErrorFlags` INT NOT NULL DEFAULT '0' AFTER `QFall`;",
};
ActivityStart();
if (!upgradeResultsDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(Results.DB.ConnectionString), commands))
{
ActivityEnd();
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
upgradeDb_216_217_Button.Enabled = false;
}
}
///---------------------------------------------------------------------
private void upgradeDb_217_218_Button_Click(object sender, EventArgs e)
{
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
{
MessageBox.Show("No database selected");
return;
}
string[] commands = new string[]
{
"ALTER TABLE `measurementcorrection` ADD `RangeIx` INT NOT NULL DEFAULT '0' AFTER `Id`;",
};
ActivityStart();
if (!upgradeConfigDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(TBF.DB.CurrentBench.ProceduresDBSettings.ConnectionString), commands))
{
ActivityEnd();
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
upgradeDb_217_218_Button.Enabled = false;
}
}
///---------------------------------------------------------------------
private void upgradeDb_218_222_Button_Click(object sender, EventArgs e)
{
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
{
MessageBox.Show("No database selected");
return;
}
string[] resultsDbCommands = new string[]
{
"ALTER TABLE `metertestrslt` ADD `RegReaderType` INT NOT NULL DEFAULT '0' AFTER `CompoundMeterId`;",
"ALTER TABLE `testrslt` ADD `MethodClass` VARCHAR(255) NULL DEFAULT NULL AFTER `RepetitionNr`," +
" ADD `TimeBtwnMassMsrmnts` INT NOT NULL DEFAULT '0' AFTER `FlowSetTime`," +
" ADD `TestTimeCorrection` DOUBLE NOT NULL DEFAULT '0' AFTER `TestTime`," +
" ADD `ConstMasterRaw` DOUBLE NOT NULL DEFAULT '1' AFTER `PulsesMaster`," +
" ADD `ConstMasterCorr` DOUBLE NOT NULL DEFAULT '1' AFTER `ConstMasterRaw`;",
"ALTER TABLE `watermeterdata` ADD `Medium` VARCHAR(255) NULL DEFAULT NULL AFTER `ApprovalInfoAux`;",
"ALTER TABLE `batch` ADD `Counter1` INT NOT NULL DEFAULT '0' AFTER `Custom3`," +
" ADD `Counter2` INT NOT NULL DEFAULT '0' AFTER `Counter1`," +
" ADD `Counter3` INT NOT NULL DEFAULT '0' AFTER `Counter2`," +
" ADD `Counter4` INT NOT NULL DEFAULT '0' AFTER `Counter3`," +
" ADD `Counter5` INT NOT NULL DEFAULT '0' AFTER `Counter4`," +
" ADD `Counter6` INT NOT NULL DEFAULT '0' AFTER `Counter5`," +
" ADD `Counter7` INT NOT NULL DEFAULT '0' AFTER `Counter6`," +
" ADD `Counter8` INT NOT NULL DEFAULT '0' AFTER `Counter7`," +
" ADD `Counter9` INT NOT NULL DEFAULT '0' AFTER `Counter8`," +
" ADD `Counter10` INT NOT NULL DEFAULT '0' AFTER `Counter9`;",
};
ActivityStart();
if (!upgradeResultsDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(Results.DB.ConnectionString), resultsDbCommands))
{
ActivityEnd();
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
upgradeDb_218_222_Button.Enabled = false;
}
}
private void upgradeDb_222_224_Button_Click(object sender, EventArgs e)
{
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
{
MessageBox.Show("No database selected");
return;
}
string[] configDbCommands = new string[]
{
/// Table profile
"CREATE TABLE IF NOT EXISTS `profile` (" +
"`Id` int(11) NOT NULL AUTO_INCREMENT," +
" `ItemNr` int(11) NOT NULL DEFAULT '0'," +
" `Name` varchar(255) CHARACTER SET utf8 COLLATE utf8_unicode_ci DEFAULT NULL," +
" `Description` varchar(255) CHARACTER SET utf8 COLLATE utf8_unicode_ci DEFAULT NULL," +
" `CreationUser` varchar(255) CHARACTER SET utf8 COLLATE utf8_unicode_ci DEFAULT NULL," +
" `CreationTime` datetime DEFAULT NULL," +
" `LastChgUser` varchar(255) CHARACTER SET utf8 COLLATE utf8_unicode_ci DEFAULT NULL," +
" `LastChgTime` datetime DEFAULT NULL," +
" `ProfileType` varchar(255) CHARACTER SET utf8 COLLATE utf8_unicode_ci DEFAULT NULL," +
" `ErrorLimitType` varchar(255) CHARACTER SET utf8 COLLATE utf8_unicode_ci DEFAULT NULL," +
" PRIMARY KEY (`Id`));",
/// Table ptest
"CREATE TABLE IF NOT EXISTS `ptest` (" +
"`Id` int(11) NOT NULL AUTO_INCREMENT," +
" `ItemNr` int(11) NOT NULL DEFAULT '0'," +
" `Name` varchar(255) DEFAULT NULL," +
" `Part` int(11) NOT NULL DEFAULT '0'," +
" `CoefQfrom` double NOT NULL DEFAULT '0'," +
" `CoefQto` double NOT NULL DEFAULT '0'," +
" `ErrLimLo` double NOT NULL DEFAULT '0'," +
" `ErrLimHi` double NOT NULL DEFAULT '0'," +
" `TempLimLo` double NOT NULL DEFAULT '0'," +
" `TempLimHi` double NOT NULL DEFAULT '0'," +
" `PressLimLo` double NOT NULL DEFAULT '0'," +
" `PressLimHi` double NOT NULL DEFAULT '0'," +
" `Publish` tinyint(4) NOT NULL DEFAULT '1'," +
" `Evaluate` boolean NOT NULL DEFAULT TRUE," +
" `E1` tinyint(4) NOT NULL DEFAULT '0'," +
" `E2` tinyint(4) NOT NULL DEFAULT '0'," +
" `E3` tinyint(4) NOT NULL DEFAULT '0'," +
" `E4` tinyint(4) NOT NULL DEFAULT '0'," +
" `E5` tinyint(4) NOT NULL DEFAULT '0'," +
" `E6` tinyint(4) NOT NULL DEFAULT '0'," +
" `E7` tinyint(4) NOT NULL DEFAULT '0'," +
" `E8` tinyint(4) NOT NULL DEFAULT '0'," +
" `E9` tinyint(4) NOT NULL DEFAULT '0'," +
" `E10` tinyint(4) NOT NULL DEFAULT '0'," +
" `E11` tinyint(4) NOT NULL DEFAULT '0'," +
" `E12` tinyint(4) NOT NULL DEFAULT '0'," +
" `E13` tinyint(4) NOT NULL DEFAULT '0'," +
" `E14` tinyint(4) NOT NULL DEFAULT '0'," +
" `E15` tinyint(4) NOT NULL DEFAULT '0'," +
" `E16` tinyint(4) NOT NULL DEFAULT '0'," +
" `E21` tinyint(4) NOT NULL DEFAULT '0'," +
" `Delta_Q_pct` double NOT NULL DEFAULT '0'," +
" `Delta_T` double NOT NULL DEFAULT '0'," +
" `Delta_Tup_Tdn` double NOT NULL DEFAULT '0'," +
" `TestTime_min` double NOT NULL DEFAULT '0'," +
" `TestTime_max` double NOT NULL DEFAULT '0'," +
" `AmbTemp_min` double NOT NULL DEFAULT '0'," +
" `AmbTemp_max` double NOT NULL DEFAULT '0'," +
" `Coef_E9` double NOT NULL DEFAULT '0'," +
" `Coef_E10` double NOT NULL DEFAULT '0'," +
" `Coef_E11` double NOT NULL DEFAULT '0'," +
" `Coef_E12` double NOT NULL DEFAULT '0'," +
" `Offset_E9` double NOT NULL DEFAULT '0'," +
" `Offset_E12` double NOT NULL DEFAULT '0'," +
" `Profile_id` int(11) DEFAULT NULL," +
" PRIMARY KEY (`Id`));",
/// Table test
"ALTER TABLE `test` ADD `Qtg` FLOAT NULL DEFAULT NULL AFTER `Evaluate`;",
"ALTER TABLE `test` CHANGE `RelTransAfter` `Profile` VARCHAR(255) CHARACTER SET utf8 COLLATE utf8_general_ci NULL DEFAULT NULL;",
"UPDATE `test` SET Profile = 'UserDefined';",
/// Table uncertainty
"CREATE TABLE IF NOT EXISTS `uncertainty` (" +
" `Id` int(11) NOT NULL AUTO_INCREMENT," +
" `Measurement` float NOT NULL DEFAULT '0'," +
" `MainUncertainty` float NOT NULL DEFAULT '0'," +
" `Resolution` float NOT NULL DEFAULT '0'," +
" `DriftPerYr` float NOT NULL DEFAULT '0'," +
" `Conditions` float NOT NULL DEFAULT '0'," +
" `UncertaintyOfCorrection` float NOT NULL DEFAULT '0'," +
" `Component_id` int(11) DEFAULT NULL," +
" PRIMARY KEY (`Id`)," +
" KEY `Component_id` (`Component_id`));",
/// Table user
"ALTER TABLE `user` ADD `Password2` VARCHAR(255) NULL DEFAULT NULL AFTER `Password`, ADD `Password3` VARCHAR(255) NULL DEFAULT NULL AFTER `Password2`, ADD `Password4` VARCHAR(255) NULL DEFAULT NULL AFTER `Password3`;",
/// Tables watermeter and wmtype
"DROP TABLE `watermeter`",
"DROP TABLE `wmtype`",
//"ALTER TABLE `procedure` DROP `ProtocolTitle`",
};
string[] resultsDbCommands = new string[]
{
"ALTER TABLE `testdata` ADD `Qtg` DOUBLE NULL DEFAULT NULL AFTER `Name`;",
"ALTER TABLE `testrslt` ADD `Uncertnt` FLOAT NOT NULL DEFAULT '0' AFTER `FlowMax`," +
" ADD `UncertntScale` FLOAT NOT NULL DEFAULT '0' AFTER `Uncertnt`," +
" ADD `UncertntDensity` FLOAT NOT NULL DEFAULT '0' AFTER `UncertntScale`," +
" ADD `UncertntTemp` FLOAT NOT NULL DEFAULT '0' AFTER `UncertntDensity`," +
" ADD `UncertntPressure` FLOAT NOT NULL DEFAULT '0' AFTER `UncertntTemp`;",
"ALTER TABLE `testrslt` CHANGE `ErrorFlags` `ErrorFlags` BIGINT(20) NOT NULL DEFAULT '0', CHANGE `ErrorFlagsMd` `InfoFlags` BIGINT(20) NOT NULL DEFAULT '0';",
"ALTER TABLE `watermeter` CHANGE `ErrorFlags` `ErrorFlags` BIGINT(20) NOT NULL DEFAULT '0', ADD `InfoFlags` BIGINT NOT NULL DEFAULT '0' AFTER `ErrorFlags`;",
#if IPERL
"ALTER TABLE `watermeter` DROP `Q2CorrectionDone`, DROP `Q2Correction`;",
#endif
};
ActivityStart();
bool success = true;
if (upgradeConfigDBCheckBox.Checked)
{
success = success && ExecuteCommands(new MySqlConnection(TBF.DB.CurrentBench.ProceduresDBSettings.ConnectionString), configDbCommands);
if (!string.IsNullOrEmpty(errorFlagsComponentsTextBox.Text))
{
string[] errorFlagsCmpnts = errorFlagsComponentsTextBox.Text.Split(new char[] { '~' });
foreach (var errFCmpnt in errorFlagsCmpnts)
{
success = success && ChangeErrorFlags(errFCmpnt);
}
}
}
if (upgradeResultsDBCheckBox.Checked)
{
success = success && ExecuteCommands(new MySqlConnection(Results.DB.ConnectionString), resultsDbCommands);
}
if (success)
{
ActivityEnd();
MessageBox.Show("DB succesfully upgraded." + Environment.NewLine +
"Please, create Density and Buoyancy components.",
"Confirmation",
MessageBoxButtons.OK,
MessageBoxIcon.Information);
upgradeDb_222_224_Button.Enabled = false;
}
}
private void upgradeDb_224_225_Button_Click(object sender, EventArgs e)
{
MySqlConnection dbConn = null;
MySqlCommand cmd;
ActivityStart();
bool success = false;
try
{
dbConn = new MySqlConnection(TBF.DB.CurrentBench.ProceduresDBSettings.ConnectionString);
dbConn.Open();
cmd = dbConn.CreateCommand();
cmd.CommandText = "CREATE TABLE IF NOT EXISTS `usersgroups` ( `Group_id` int(11) NOT NULL, `User_id` int(11) NOT NULL );";
cmd.ExecuteNonQuery();
cmd.Dispose();
cmd = dbConn.CreateCommand();
cmd.CommandText = "ALTER TABLE `usersgroups` ADD KEY `User_id` (`User_id`), ADD KEY `Group_id` (`Group_id`)," +
" ADD CONSTRAINT `FKEC3AF23393C4061C` FOREIGN KEY (`Group_id`) REFERENCES `group` (`Id`)," +
" ADD CONSTRAINT `FKEC3AF23373767C99` FOREIGN KEY (`User_id`) REFERENCES `user` (`Id`);";
cmd.ExecuteNonQuery();
cmd.Dispose();
int[] groupIdsToKeep = new int[(int)Common.GID.NrOfGroups];
IList groupTable = new List();
cmd = dbConn.CreateCommand();
cmd.CommandText = "SELECT `Id`, `Gid`, `User_id` FROM `group`;";
MySqlDataReader dr = cmd.ExecuteReader();
while (dr.Read())
{
int groupId = dr.GetInt32(0);
Common.GID gid = (Common.GID)dr.GetInt32(1);
int userId = dr.GetInt32(2);
groupTable.Add(new GroupTableRow(groupId, gid, userId));
if ((gid >= 0) && (gid < Common.GID.NrOfGroups) && (groupIdsToKeep[(int)gid] == 0))
{
groupIdsToKeep[(int)gid] = groupId;
}
}
dr.Close();
foreach (var groupTableRow in groupTable)
{
cmd = dbConn.CreateCommand();
cmd.CommandText = string.Format("INSERT INTO `usersgroups` (`Group_id`, `User_id`) VALUES ({0}, {1});",
groupIdsToKeep[(int)groupTableRow.Gid],
groupTableRow.UserId);
cmd.ExecuteNonQuery();
cmd.Dispose();
}
//foreach (var groupTableRow in groupTable)
//{
// bool deleteThisRow = true;
// for (int i = 0; i < groupIdsToKeep.Length; i++)
// {
// if (groupTableRow.GroupId == groupIdsToKeep[i])
// {
// deleteThisRow = false;
// break;
// }
// }
// if (deleteThisRow)
// {
// cmd = dbConn.CreateCommand();
// cmd.CommandText = string.Format("DELETE FROM `group` WHERE `Id` = {0}", groupTableRow.GroupId);
// cmd.ExecuteNonQuery();
// cmd.Dispose();
// }
//}
cmd = dbConn.CreateCommand();
cmd.CommandText = string.Format("ALTER TABLE `group` ADD `AccessFlags` BIGINT NOT NULL DEFAULT '0' AFTER `Name`;");
cmd.ExecuteNonQuery();
cmd.Dispose();
success = true;
}
catch (Exception exc)
{
log.ErrorFormat(string.Format("Exception when upgrading DB: {0}", exc.Message));
if (exc.InnerException != null) log.ErrorFormat(string.Format("Inner exception: {0}", exc.InnerException.Message));
ActivityEnd();
MessageBox.Show(string.Format("Exception {0}", exc.Message), "Error", MessageBoxButtons.OK, MessageBoxIcon.Exclamation);
}
finally
{
if (dbConn != null) dbConn.Close();
}
if (success)
{
ActivityEnd();
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
upgradeDb_224_225_Button.Enabled = false;
}
}
private void upgradeDb_225_226_Button_Click(object sender, EventArgs e)
{
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
{
MessageBox.Show("No database selected");
return;
}
string[] configDbCommands = new string[]
{
"ALTER TABLE `procedure` ADD `EventTriggers` varchar(255) COLLATE utf8_unicode_ci DEFAULT NULL AFTER `ResultsWriter`;",
"CREATE TABLE IF NOT EXISTS `customevent` (" +
"`Id` int(11) NOT NULL," +
" `Date` datetime DEFAULT NULL," +
" `Frequency` varchar(255) COLLATE utf8_unicode_ci DEFAULT NULL," +
" `AllDay` tinyint(1) DEFAULT NULL," +
" `TriggerOnExactDayOnly` tinyint(1) DEFAULT NULL," +
" `Source` varchar(255) COLLATE utf8_unicode_ci DEFAULT NULL," +
" `Title` varchar(255) COLLATE utf8_unicode_ci DEFAULT NULL," +
" `AutoAction` varchar(255) COLLATE utf8_unicode_ci DEFAULT NULL," +
" `Parameters` varchar(255) COLLATE utf8_unicode_ci DEFAULT NULL," +
" `Rank` int(11) DEFAULT NULL," +
" `Hidden` tinyint(1) DEFAULT NULL," +
" `ReadOnly` tinyint(1) DEFAULT NULL," +
" `BackColor` int(11) DEFAULT NULL," +
" `TextColor` int(11) DEFAULT NULL," +
" `TooltipEnabled` tinyint(1) DEFAULT NULL) ENGINE=InnoDB DEFAULT CHARSET=utf8 COLLATE=utf8_unicode_ci AUTO_INCREMENT=1;",
"ALTER TABLE `customevent` ADD PRIMARY KEY (`Id`);",
"ALTER TABLE `customevent` MODIFY `Id` int(11) NOT NULL AUTO_INCREMENT;",
};
string[] resultsDbCommands = new string[]
{
#if TURA_IPERL || TURA_IPERL_NEW || TURA_SPECIAL
"ALTER TABLE `testrslt` ADD `ConductMean` FLOAT NULL DEFAULT NULL AFTER `FlowMax`," +
" ADD `ConductStart` FLOAT NULL DEFAULT NULL AFTER `ConductMean`," +
" ADD `ConductEnd` FLOAT NULL DEFAULT NULL AFTER `ConductStart`," +
" ADD `ConductMin` FLOAT NULL DEFAULT NULL AFTER `ConductEnd`," +
" ADD `ConductMax` FLOAT NULL DEFAULT NULL AFTER `ConductMin`;",
#endif
};
ActivityStart();
if ((!upgradeConfigDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(TBF.DB.CurrentBench.ProceduresDBSettings.ConnectionString), configDbCommands)) &&
(!upgradeResultsDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(Results.DB.ConnectionString), resultsDbCommands)))
{
ActivityEnd();
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
upgradeDb_225_226_Button.Enabled = false;
}
}
private void pressureRepresentationButton_Click(object sender, EventArgs e)
{
try
{
batchFrom = int.Parse(textBox1.Text);
batchTo = int.Parse(textBox2.Text);
if (batchFrom < 1 || batchFrom > batchTo) throw new Exception();
}
catch
{
MessageBox.Show("Wrong 'From batch #' or 'To batch #'", "Error", MessageBoxButtons.OK, MessageBoxIcon.Exclamation);
return;
}
if (MessageBox.Show("Are you sure ?", "", MessageBoxButtons.YesNo, MessageBoxIcon.Question) == DialogResult.No) return;
ActivityStart();
ISession session = null;
try
{
session = TBF.DB.ResultsDBSessionFactory.OpenSession();
IList bFrom = session.QueryOver().Where(x => (x.BatchNr == batchFrom)).List();
IList bTo = session.QueryOver().Where(x => (x.BatchNr == batchTo)).List();
if (bFrom.Count != 1) throw new Exception("No start batch");
if (bTo.Count != 1) throw new Exception("No end batch");
IList testResults = session.QueryOver()
.WhereRestrictionOn(x => x.StartTime)
.IsBetween(bFrom[0].StartTime)
.And(bTo[0].EndTime)
.List();
foreach (var tr in testResults)
{
Text = string.Format("Batch # = {0}", tr.Batch.BatchNr);
float factor1 = 0.01f;
tr.PressUpMean *= factor1;
tr.PressUpStart *= factor1;
tr.PressUpEnd *= factor1;
tr.PressUpMin *= factor1;
tr.PressUpMax *= factor1;
tr.PressDownMean *= factor1;
tr.PressDownStart *= factor1;
tr.PressDownEnd *= factor1;
tr.PressDownMin *= factor1;
tr.PressDownMax *= factor1;
tr.AmbPressMean *= 0.001f;
session.SaveOrUpdate(tr);
}
session.Flush();
ActivityEnd();
MessageBox.Show("Upgrade completed", "", MessageBoxButtons.OK, MessageBoxIcon.Information);
}
catch (Exception exc)
{
ActivityEnd();
MessageBox.Show(string.Format("Upgrade failed:\r\n{0}", exc.Message),
"Error", MessageBoxButtons.OK, MessageBoxIcon.Information);
}
finally
{
if (session != null && session.IsOpen) session.Close();
}
}
private void customButton_Click(object sender, EventArgs e)
{
ActivityStart();
ISession session = null;
try
{
session = TBF.DB.ConfigDBSessionFactory.OpenSession();
var proceduresToModify = session.QueryOver()
.Where(x => x.CmpntName == "Sensus-Oracle-DB")
.List();
foreach (var proc in proceduresToModify)
{
if (!string.IsNullOrEmpty(proc.Parameters))
{
proc.Parameters = proc.Parameters.Replace("Iperl", "iPERL");
proc.Parameters = proc.Parameters.Replace("S620", "Mechanical");
session.SaveOrUpdate(proc);
}
}
session.Flush();
ActivityEnd();
MessageBox.Show("Upgrade completed", "", MessageBoxButtons.OK, MessageBoxIcon.Information);
}
catch (Exception exc)
{
ActivityEnd();
MessageBox.Show(string.Format("Upgrade failed:\r\n{0}", exc.Message),
"Error", MessageBoxButtons.OK, MessageBoxIcon.Information);
}
finally
{
if (session != null && session.IsOpen) session.Close();
}
}
private void upgradeDb_226_227_Button_Click(object sender, EventArgs e)
{
string[] configDbCommands = new string[]
{
/// TODO
};
string[] resultsDbCommands = new string[]
{
/// TODO
};
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
{
MessageBox.Show("No database selected");
return;
}
ActivityStart();
if ((!upgradeConfigDBCheckBox.Checked || configDbCommands.Length == 0 ||
ExecuteCommands(new MySqlConnection(TBF.DB.CurrentBench.ProceduresDBSettings.ConnectionString), configDbCommands)) &&
(!upgradeResultsDBCheckBox.Checked || resultsDbCommands.Length == 0 ||
ExecuteCommands(new MySqlConnection(Results.DB.ConnectionString), resultsDbCommands)))
{
ActivityEnd();
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
upgradeDb_226_227_Button.Enabled = false;
}
}
private void upgradeDb_227_228_Button_Click(object sender, EventArgs e)
{
string[] configDbCommands = new string[]
{
/// TODO
};
string[] resultsDbCommands = new string[]
{
/// TODO
};
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
{
MessageBox.Show("No database selected");
return;
}
ActivityStart();
if ((!upgradeConfigDBCheckBox.Checked || configDbCommands.Length == 0 ||
ExecuteCommands(new MySqlConnection(TBF.DB.CurrentBench.ProceduresDBSettings.ConnectionString), configDbCommands)) &&
(!upgradeResultsDBCheckBox.Checked || resultsDbCommands.Length == 0 ||
ExecuteCommands(new MySqlConnection(Results.DB.ConnectionString), resultsDbCommands)))
{
ActivityEnd();
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
upgradeDb_227_228_Button.Enabled = false;
}
}
private void upgradeDb_228_229_Button_Click(object sender, EventArgs e)
{
string[] configDbCommands = new string[]
{
/// TODO
};
string[] resultsDbCommands = new string[]
{
/// TODO
};
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
{
MessageBox.Show("No database selected");
return;
}
ActivityStart();
if ((!upgradeConfigDBCheckBox.Checked || configDbCommands.Length == 0 ||
ExecuteCommands(new MySqlConnection(TBF.DB.CurrentBench.ProceduresDBSettings.ConnectionString), configDbCommands)) &&
(!upgradeResultsDBCheckBox.Checked || resultsDbCommands.Length == 0 ||
ExecuteCommands(new MySqlConnection(Results.DB.ConnectionString), resultsDbCommands)))
{
ActivityEnd();
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
upgradeDb_228_229_Button.Enabled = false;
}
}
private void upgradeDb_229_230_Button_Click(object sender, EventArgs e)
{
string[] configDbCommands = new string[]
{
/// TODO
};
string[] resultsDbCommands = new string[]
{
/// TODO
};
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
{
MessageBox.Show("No database selected");
return;
}
ActivityStart();
if ((!upgradeConfigDBCheckBox.Checked || configDbCommands.Length == 0 ||
ExecuteCommands(new MySqlConnection(TBF.DB.CurrentBench.ProceduresDBSettings.ConnectionString), configDbCommands)) &&
(!upgradeResultsDBCheckBox.Checked || resultsDbCommands.Length == 0 ||
ExecuteCommands(new MySqlConnection(Results.DB.ConnectionString), resultsDbCommands)))
{
ActivityEnd();
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
upgradeDb_229_230_Button.Enabled = false;
}
}
private void upgradeDb_230_231_Button_Click(object sender, EventArgs e)
{
string[] configDbCommands = new string[]
{
/// TODO
};
string[] resultsDbCommands = new string[]
{
/// TODO
};
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
{
MessageBox.Show("No database selected");
return;
}
ActivityStart();
if ((!upgradeConfigDBCheckBox.Checked || configDbCommands.Length == 0 ||
ExecuteCommands(new MySqlConnection(TBF.DB.CurrentBench.ProceduresDBSettings.ConnectionString), configDbCommands)) &&
(!upgradeResultsDBCheckBox.Checked || resultsDbCommands.Length == 0 ||
ExecuteCommands(new MySqlConnection(Results.DB.ConnectionString), resultsDbCommands)))
{
ActivityEnd();
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
upgradeDb_230_231_Button.Enabled = false;
}
}
private void upgradeDb_231_232_Button_Click(object sender, EventArgs e)
{
string[] configDbCommands = new string[] { };
string[] resultsDbCommands = new string[]
{
"ALTER TABLE `batch` CHANGE `StartTime` `StartTime` DATETIME NOT NULL DEFAULT '0001-01-01 00:00:00';",
"ALTER TABLE `batch` CHANGE `EndTime` `EndTime` DATETIME NOT NULL DEFAULT '0001-01-01 00:00:00';",
"ALTER TABLE `batch` ADD `SaveTime` DATETIME NOT NULL DEFAULT '0001-01-01 00:00:00' AFTER `EndTime`;"
};
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
{
MessageBox.Show("No database selected");
return;
}
ActivityStart();
if ((!upgradeConfigDBCheckBox.Checked || configDbCommands.Length == 0 ||
ExecuteCommands(new MySqlConnection(TBF.DB.CurrentBench.ProceduresDBSettings.ConnectionString), configDbCommands)) &&
(!upgradeResultsDBCheckBox.Checked || resultsDbCommands.Length == 0 ||
ExecuteCommands(new MySqlConnection(Results.DB.ConnectionString), resultsDbCommands)))
{
ActivityEnd();
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
upgradeDb_231_232_Button.Enabled = false;
}
}
private void upgradeDb_232_233_Button_Click(object sender, EventArgs e)
{
string[] configDbCommands = new string[]
{
"ALTER TABLE `test` CHANGE `Qtg` `Qtg` DOUBLE NOT NULL DEFAULT '0';",
"ALTER TABLE `test` CHANGE `Qfrom` `Qfrom` DOUBLE NOT NULL DEFAULT '0';",
"ALTER TABLE `test` CHANGE `Qto` `Qto` DOUBLE NOT NULL DEFAULT '0';",
"ALTER TABLE `test` CHANGE `Volume` `Volume` DOUBLE NOT NULL DEFAULT '0';",
"ALTER TABLE `test` CHANGE `TstTime` `TstTime` DOUBLE NOT NULL DEFAULT '0';"
};
string[] resultsDbCommands = new string[]
{
"ALTER TABLE `watermeterdata` ADD `Qnames` TINYINT(4) NOT NULL DEFAULT '1' AFTER `Mounting`;",
"ALTER TABLE `watermeterdata` ADD `ErrLimHiQ` DOUBLE NOT NULL DEFAULT '2' AFTER `Q1_Qmin`," +
" ADD `ErrLimLoQ` DOUBLE NOT NULL DEFAULT '5' AFTER `ErrLimHiQ`;"
};
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
{
MessageBox.Show("No database selected");
return;
}
ActivityStart();
if ((!upgradeConfigDBCheckBox.Checked || configDbCommands.Length == 0 ||
ExecuteCommands(new MySqlConnection(TBF.DB.CurrentBench.ProceduresDBSettings.ConnectionString), configDbCommands)) &&
(!upgradeResultsDBCheckBox.Checked || resultsDbCommands.Length == 0 ||
ExecuteCommands(new MySqlConnection(Results.DB.ConnectionString), resultsDbCommands)))
{
if (upgradeConfigDBCheckBox.Checked)
{
ISession session = null;
try
{
session = TBF.DB.ConfigDBSessionFactory.OpenSession();
var tests = session.QueryOver().List();
foreach (var t in tests)
{
string singlePrecStr = Convert.ToSingle(t.Qtg).ToString();
if (t.Qtg.ToString().Length > 2 * singlePrecStr.Length) t.Qtg = double.Parse(singlePrecStr);
singlePrecStr = Convert.ToSingle(t.Qfrom).ToString();
if (t.Qfrom.ToString().Length > 2 * singlePrecStr.Length) t.Qfrom = double.Parse(singlePrecStr);
singlePrecStr = Convert.ToSingle(t.Qto).ToString();
if (t.Qto.ToString().Length > 2 * singlePrecStr.Length) t.Qto = double.Parse(singlePrecStr);
session.SaveOrUpdate(t);
}
session.Flush();
}
catch (Exception exc)
{
ActivityEnd();
MessageBox.Show(string.Format("Test flow rounding after a conversion to double failed:\r\n{0}", exc.Message),
"Error", MessageBoxButtons.OK, MessageBoxIcon.Information);
}
finally
{
if (session != null && session.IsOpen) session.Close();
}
}
ActivityEnd();
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
upgradeDb_232_233_Button.Enabled = false;
}
}
}
}