/// Copyright (c) 2013-2021 Sensus Slovensko a.s.
///
using System;
using System.Collections.Generic;
using System.Text;
using log4net;
using TBF.Rig;
using TBF.Boxes;
using TBF.Resources;
using TBF.UiBridge;
using TBF.Rig.GenericDevices;
namespace TBF.Rig.TestMethods.FlyingStartMassCollection
{
public class FlyingStartMassCollectionSeq : Sequences.SequenceBase
{
private static readonly ILog log = LogManager.GetLogger(typeof(FlyingStartMassCollectionSeq));
///
/// Check capabilities of devces in the output path required for this test method
///
/// Devices
/// true when capabilities of devices are OK
public static bool CheckDeviceCaps(Config.Entities.Test test, OutputPath devices, out string message)
{
if (!(StateMachine.ControlBoard is ControlBoard.Uni.UniCB))
{
/// Control board does not support this method
message = string.Format("{0}: {1}", test.Name, Strings.Test_bench_does_not_suport_selected_test_method);
return false;
}
if (!(devices.Scale is IScale))
{
/// Scale is missing
message = string.Format("{0}: {1}", test.Name, Strings.Missing_a_scale);
return false;
}
if (test.Volume > devices.Scale.Capacity * Constants.TankFullFactor)
{
/// Scale capacity is not sufficient
message = string.Format("{0}: {1}", test.Name, Strings.Test_volume_exceeds_the_scale_capacity);
return false;
}
if (!(devices.Diverter is IDiverter))
{
/// Scale is missing
message = string.Format("{0}: {1}", test.Name, Strings.Missing_a_diverter);
return false;
}
if (!(devices.FlowMeter is IFlowMeter))
{
/// Flow meter is missing
message = string.Format("{0}: {1}", test.Name, Strings.Missing_a_flow_meter);
return false;
}
if (!(devices.RegValve is GenericDevices.IRegValve))
{
/// Regulation valve is missing
message = string.Format("{0}: {1}", test.Name, Strings.Missing_a_regulation_valve);
return false;
}
message = string.Empty;
return true;
}
///
/// Flying start mass collection method sequence
///
/// Test entity
///
/// Event.Done . . . . . . . OK
/// Event.UiCmdStop . . . . Stopped by the user using the on-screen button STOP
/// Event.OpArgumentError . Target flow is out of range
/// Event.Error . . . . . . Unspecified error
///
public IList Execute(Config.Entities.Test test, int repetitionNr, bool isLastRepetition,
Compound.CombinedTestParams compoundTestParams,
HeatMeters.TestParams heatMetersTestParams,
Config.Entities.DebugMode debugLevel)
{
if (debugLevel == Config.Entities.DebugMode.Simulate)
{
return Simulate1(test, repetitionNr, isLastRepetition, compoundTestParams, heatMetersTestParams);
}
else if (debugLevel == Config.Entities.DebugMode.Inherit)
{
return Simulate2(test, repetitionNr, isLastRepetition, compoundTestParams, heatMetersTestParams);
}
ControlBoard.Uni.UniCB cBrd = StateMachine.ControlBoard as ControlBoard.Uni.UniCB;
IScale scale = cBrd.Devices.Scale as IScale;
int rangeIx = 0; /// Default range, used for non-Elde flowmeters
if (outPath.FlowMeter is Uni.FlowMeter.FlowMeter)
{
Uni.FlowMeter.FlowMeter eldeFM = outPath.FlowMeter as Uni.FlowMeter.FlowMeter;
rangeIx = -1; /// Indicates invalid range
for (int r = 0; r <= 5; r++)
{
if (eldeFM.RangeEnabled(r) && eldeFM.GetTempLo(r) <= test.TempLimLo
&& eldeFM.GetTempHi(r) >= test.TempLimHi)
{
rangeIx = r;
}
}
if (rangeIx == -1)
{
Bridge.OnError(this, Strings.Flow_meter_temperature_range_does_not_fit_this_test_conditions);
return new List { Event.ConfigurationError }; /// or Event.UiCmdStop ???
}
}
IList e; /// Events from currently running operations
Event retVal = Event.Done;
int tMass1 = 0;
int tMass2 = 0;
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
processDataLoggingOp = new TBF.Rig.Operations.ProcessDataLoggingOp(processDataLogger, this, heatMetersTestParams != null);
if (cBrd is ControlBoard.Uni.UniCB)
{
int[] filters = new int[] { 0, 0, 0, 0, 0, 0, 0, 0 };
if (sensPath != null && sensPath.RegisterReaders != null)
{
foreach (var rr in sensPath.RegisterReaders)
{
IRegReaderPulses rrPls = rr as IRegReaderPulses;
if (rrPls != null && rrPls.Position >= 1 && rrPls.Position <= 8)
{
filters[rrPls.Position - 1] = rrPls.Filter;
}
}
}
(cBrd as ControlBoard.Uni.UniCB).SetFiltersPidShortPulses(filters, outPath.PidCoef, test.ShortPulses);
}
IList readTempPressOps = new List();
if(benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
if(benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
if(outPath.TempMtrDiv != null) readTempPressOps.Add(outPath.TempMtrDiv.ReadTempOp(ref TempDiv));
if(benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
if(benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
if(benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
if(heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
if(heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
if(heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
if(heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
LtrPerRefPulse = cBrd.Devices.FlowMeter.LtrPerPulse;
int totalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f);
//====================================
loop:
/// Read pressure and temperature once before calling Bridge.OnTestSelected(...)
State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperations(readTempPressOps)
.EnterState();
do {
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (e.Contains(Event.Busy));
/// Start the test, initialize test results
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath));
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
TestStartTime = DateTime.Now;
foreach (var rr in sensPath.RegisterReaders)
{
GenericDevices.IHasTestName readerWithTstName = rr as GenericDevices.IHasTestName;
if (readerWithTstName != null)
{
readerWithTstName.TestName = test.Name;
readerWithTstName.TestRepeats = test.Repeats;
readerWithTstName.RepetitionNr = repetitionNr;
}
}
//------------------------------------------------
Bridge.OnActivity(this, Strings.Checking_tank_capacity);
//------------------------------------------------
bool drainTheTank = test.DoDraining;
if (!drainTheTank) /// If condition met => skip measuring and force emptying
{
///
/// Measure the weight and skip emptying if there is enough room in the tank
///
State.Create(string.Format("{0}({1}) : Checking available tank capacity", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperations(readTempPressOps)
.AddOperation(scale.ReadMassOp(ref Mass))
.EnterState();
do {
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.ScaleDone));
double estimatedEndMass = Mass.Val + test.Volume;
if (estimatedEndMass >= scale.Capacity * Constants.TankFullFactor)
{
drainTheTank = true;
}
}
///
if (drainTheTank)
{
#if BERLIN || SENTEC
switch (DrainTheTank(scale, readTempPressOps))
{
case Event.Error: { retVal = Event.Error; goto stopTest; }
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
}
drainTheTank = false;
#else
State.Create(string.Format("{0}({1}) : Open the drain valve", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(cBrd.SetValvesOp(scale.DrainValve, null))
.AddOperations(readTempPressOps)
.EnterState();
do {
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (e.Contains(Event.ValvesBusy));
#endif
}
///
/// Optionally display prompt to emerge temperature meters to appropriate baths for heat meters test
///
IOperation heatMetersPromptOp = null;
if (heatMetersTestParams != null && !string.IsNullOrEmpty(heatMetersTestParams.Prompt))
{
/// Make sure the CycleBeginForm is closed
if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stopTest;
heatMetersPromptOp = new Operations.MessageBoxOp(heatMetersTestParams.Prompt);
}
//------------------------------------------------
Bridge.OnActivity(this, Strings.Starting_the_pump);
//------------------------------------------------
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
int flowSetTime0 = StateMachine.Time;
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
///
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
.AddOperation(checkUiOp)
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
.AddOperations(readTempPressOps)
.AddOperation(heatMetersPromptOp)
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
.EnterState();
do {
e = StateMachine.WaitRunDevsRunOps();
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
}
while (e.Contains(Event.ValvesBusy) /* || !e.Contains(Event.AllPositionsReached)*/);
if (test.TimePump2StartV > 0)
{
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
.AddOperations(readTempPressOps)
.AddOperation(heatMetersPromptOp)
.EnterState();
do {
e = StateMachine.WaitRunDevsRunOps();
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.TimerExpired));
}
if (benchPath.StopBFValve != null)
{
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(cBrd.SetValvesOp(benchPath.StopBFValve, null))
.AddOperations(readTempPressOps)
.AddOperation(heatMetersPromptOp)
.EnterState();
do {
e = StateMachine.WaitRunDevsRunOps();
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
}
while (!e.Contains(Event.ValvesSet));
}
if (test.TimeBeforeFlow > 0)
{
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
.AddOperations(readTempPressOps)
.AddOperation(heatMetersPromptOp)
.EnterState();
do {
e = StateMachine.WaitRunDevsRunOps();
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.TimerExpired));
}
setting_flow:
//------------------------------------------------
Bridge.OnActivity(this, Strings.Setting_the_flow);
//------------------------------------------------
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(cBrd.SetFlowOp(test.Qfrom, test.Qto, RefFlow, FlowSettingTimeoutSec))
.AddOperations(readTempPressOps)
.AddOperation(heatMetersPromptOp)
.EnterState();
do {
e = StateMachine.WaitRunDevsRunOps();
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
if (e.Contains(Event.OpArgumentError)) { retVal = Event.OpArgumentError; goto stopTest; }
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
if (e.Contains(Event.RegulValveTimeOut))
{
Bridge.OnError(this, Strings.Flow_adjustment_failed);
retVal = Event.RecoverableError;
goto stopTest;
}
if (e.Contains(Event.Next)) goto flow_set;
}
while (!e.Contains(Event.FlowReached));
flow_set:
int flowSetTime = StateMachine.Time - flowSetTime0;
double currentFlow = RefFlow.Val;
if (heatMetersTestParams != null && heatMetersPath != null)
{
//---------------------------------------------------
Bridge.OnActivity(this, Strings.Setting_temperature);
//---------------------------------------------------
int lastTimeSec = StateMachine.Time;
double Tw_last = 0;
double Tc_last = 0;
State.Create(string.Format("{0}({1}) : Check temperature stabilized.", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperations(readTempPressOps)
.AddOperation(heatMetersPromptOp)
.EnterState();
do {
e = StateMachine.WaitRunDevsRunOps();
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
if (e.Contains(Event.Next)) goto temperature_set;
if (TempRefHi1.Val != 0 && TempRefHi2.Val != 0 && TempRefLo1.Val != 0 && TempRefLo2.Val != 0)
{
if (StateMachine.Time - lastTimeSec > 10 || StateMachine.Time - lastTimeSec < 0)
{
double Tw = (TempRefHi1.Val + TempRefHi2.Val) / 2;
double Tc = (TempRefLo1.Val + TempRefLo2.Val) / 2;
if (heatMetersTestParams.TempWarmLo <= Tw && Tw <= heatMetersTestParams.TempWarmHi &&
heatMetersTestParams.TempColdLo <= Tc && Tc <= heatMetersTestParams.TempColdHi &&
Math.Abs(Tw - Tw_last) <= heatMetersTestParams.ChangeInTimeWarm &&
Math.Abs(Tc - Tc_last) <= heatMetersTestParams.ChangeInTimeCold &&
Math.Abs(TempRefHi1.Val - TempRefHi2.Val) <= heatMetersTestParams.DeltaTempWarm &&
Math.Abs(TempRefLo1.Val - TempRefLo2.Val) <= heatMetersTestParams.DeltaTempCold)
{
goto temperature_set;
}
lastTimeSec = StateMachine.Time;
Tw_last = Tw;
Tc_last = Tc;
}
}
}
while (true);
}
else if (test.DoControlWaterTemp && benchPath.TempMtrUp != null && benchPath.TempMtrDown != null)
{
//---------------------------------------------------
Bridge.OnActivity(this, Strings.Setting_temperature);
//---------------------------------------------------
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperations(readTempPressOps)
.EnterState();
do {
e = StateMachine.WaitRunDevsRunOps();
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
if (e.Contains(Event.Next)) goto temperature_set;
if ((test.TempLimLo <= TempUp.Val) && (TempUp.Val <= test.TempLimHi) &&
(test.TempLimLo <= TempDown.Val) && (TempDown.Val <= test.TempLimHi))
{
goto temperature_set;
}
}
while (true);
}
temperature_set:
///
/// Prepare cameras, ROI-s and measurementOperations
///
/// Find successfully detected ROI-s
IList rois = new List();
foreach (var rr in sensPath.RegisterReaders)
{
GenericDevices.IRegReaderLiveCamera cameraRoI = rr as GenericDevices.IRegReaderLiveCamera;
if ((cameraRoI != null) && cameraRoI.Detected)
{
rois.Add(cameraRoI);
}
}
/// Find cameras
IList cameras = new List();
foreach (var roi in rois)
{
if (roi.Camera != null && !cameras.Contains(roi.Camera))
{
cameras.Add(roi.Camera);
roi.Camera.ClearRoiParams();
}
}
/// Register ROI-parameters to cameras
foreach (var roi in rois) roi.RegisterRoiToCamera();
/// Prepare measurementOperations
IList cameraMeasurementOps = new List();
foreach (var camera in cameras) cameraMeasurementOps.Add(camera.MeasurementOp());
if (drainTheTank)
{
//------------------------------------------------
Bridge.OnActivity(this, Strings.Closing_the_tank);
//------------------------------------------------
///
/// Make sure tank draining completed
///
switch (DrainTheTank(scale, readTempPressOps))
{
case Event.Error: { retVal = Event.Error; goto stopTest; }
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
}
drainTheTank = false;
}
else
{
/// Close the drain valve anyway
State.Create(string.Format("{0}({1}) : Close the drain valve", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperations(readTempPressOps)
.AddOperation(cBrd.SetValvesOp(null, scale.DrainValve))
.EnterState();
do {
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (e.Contains(Event.ValvesBusy));
}
//------------------------------------------------
Bridge.OnActivity(this, Strings.Measuring_the_weight);
//------------------------------------------------
LogProcessDataTestInfo(processDataLogger, test.Procedure.Name, test.Name);
if (heatMetersPath == null) LogProcessDataHeader(processDataLogger, "Start mass");
else LogProcessDataHeaderHeatMeters(processDataLogger, "Start mass");
State.Create(string.Format("{0}({1}) : Measuring the start mass", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperations(readTempPressOps)
.AddOperations(cameraMeasurementOps)
.AddOperation(scale.ReadStableMassOp(ref StartMass, test.TimeFlow2Mass, test.MassMethod, test.MassRepeats, test.MassSpread))
.AddOperation(processDataLoggingOp)
.EnterState();
do {
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
if (e.Contains(Event.ScaleTimeout))
{
Bridge.OnError(this, Strings.Mass_measurement_timeout);
retVal = Event.RecoverableError;
goto stopTest;
}
}
while (!e.Contains(Event.ScaleDone));
Mass.Val = StartMass.Val;
tMass1 = StateMachine.Time;
log.WarnFormat("Start mass = {0}kg", StartMass);
if (heatMetersPath == null)
LogProcessDataHeader(processDataLogger, "Measurement");
else
LogProcessDataHeaderHeatMeters(processDataLogger, "Measurement");
//------------------------------------------------
Bridge.OnActivity(this, Strings.Test_in_progress);
//------------------------------------------------
/// Measurement loop preparation
int estimtdEndTime = StateMachine.Time + (int)test.TestTime;
int remainingTime;
StartNewStatistics(StateMachine.Time, BatchRslts.Batch.BatchNr, test.Name, repetitionNr, 0);
/// Measurement loop
State.Create(string.Format("{0}({1}) : FlyingStartStopTestWithDivOp is running", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperations(readTempPressOps)
.AddOperations(cameraMeasurementOps)
.AddOperation(cBrd.FlyingStartStopTestOp(test, test.Qfrom, test.Qto, totalPulses, true))
.AddOperation(processDataLoggingOp)
.EnterState();
do {
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.OpArgumentError)) { retVal = Event.OpArgumentError; goto stopTest; }
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
/// Show remaining time
if ((remainingTime = Math.Max(estimtdEndTime - StateMachine.Time, 0)) > 60)
Bridge.OnActivity(this, string.Format("{0} ... {1} {2} {3} {4}", Strings.Test_in_progress, remainingTime / 60, "min", remainingTime % 60, Strings.sec));
else
Bridge.OnActivity(this, string.Format("{0} ... {1} s", Strings.Test_in_progress, remainingTime));
/// Update statistics
RefFrequency.Val = cBrd.RefFrequency;
RefFlow.Val = outPath.FlowMeter.ReadFlow();
UpdateAllStatistics(StateMachine.Time);
#region Heat meters
if (heatMetersTestParams != null)
{
/// Update heatmeter volume and energy values
if (lastEnergyUpdateTime == 0)
{
lastEnergyUpdateTime = StateMachine.Time;
}
else
{
//double deltaTime = (double)(StateMachine.Time - lastEnergyUpdateTime);
double T_in = (TempRefHi1.Val + TempRefHi2.Val) / 2; /// [°C]
double T_out = (TempRefLo1.Val + TempRefLo2.Val) / 2; /// [°C]
double deltaVolume = LtrPerRefPulse * RefPulsesDelta; /// [l]
double deltaEnergy = (0.001 * deltaVolume) * (T_in - T_out) * Config.Formulas.HeatCoefficientWater(16, T_in, T_out, heatMetersTestParams.FlowMeasuredAtHiTempPipe); /// [J] = [m3] * [K] * [J/(m3 K)]
Energy.Update(deltaEnergy);
VolumeForEnergy.Update(deltaVolume);
lastEnergyUpdateTime = StateMachine.Time;
}
}
#endregion
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
}
while (!e.Contains(Event.TestCompleted) && !e.Contains(Event.Next)); /// 'Next' button is enabled in Debug version only
/// Measurement loop end
StopRecordingStatistics();
///
/// (Berlin:) Water is stopped immediately after the test and before the 2nd mass measurement in case:
/// - no 'transition sequence after test' is used
/// - this is the last (or the only) test repetition or test is a part of an 'outer loop'
///
#if !CEVAK_200
if (isLastRepetition && transitionAfter == null)
#endif
{
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOff();
State.Create("SequenceBase : Transition : TestEnd - Default action")
.AddOperation(checkUiOp)
.AddOperations(readTempPressOps)
.AddOperation(cBrd.SetValvesOp(StateMachine.DefaultValvesOpen, StateMachine.DefaultValvesClose))
.EnterState();
do {
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.ValvesSet));
}
//------------------------------------------------
Bridge.OnActivity(this, Strings.Measuring_the_weight);
//------------------------------------------------
if (heatMetersPath == null) LogProcessDataHeader(processDataLogger, "End mass");
else LogProcessDataHeaderHeatMeters(processDataLogger, "End mass");
State.Create(string.Format("{0}({1}) : Measuring the end mass", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperations(readTempPressOps)
.AddOperation(scale.ReadStableMassOp(ref EndMass, test.TimeStop2Mass, test.MassMethod, test.MassRepeats, test.MassSpread))
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
.AddOperation(processDataLoggingOp)
.EnterState();
do {
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
if (e.Contains(Event.ScaleTimeout))
{
Bridge.OnError(this, Strings.Mass_measurement_timeout);
retVal = Event.RecoverableError;
goto stopTest;
}
}
while (!e.Contains(Event.ScaleDone));
///
tMass2 = StateMachine.Time;
log.WarnFormat("End mass = {0}kg", EndMass);
TestEndTime = DateTime.Now;
if (test.DoDrainingAfter)
{
State.Create(string.Format("{0}({1}) : Open the drain valve", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(cBrd.SetValvesOp(scale.DrainValve, null))
.AddOperations(readTempPressOps)
.EnterState();
do {
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
}
while (e.Contains(Event.ValvesBusy));
}
//------------------------------------------------
Bridge.OnActivity(this, Strings.Test_completed);
//------------------------------------------------
/// Make sure the CycleBeginForm is closed so that water meter data (s/n) can be copied into results
if (heatMetersPromptOp == null)
{
if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stopTest;
}
///
/// Populate TestResult data entity with data
///
Results.Entities.TestRslt tstRslt = BatchRslts.GetTestRslt(testName, test.Part);
if (tstRslt != null)
{
Results.Utils.GetCounterStates(tstRslt, Program.LocalSettings.Counters);
UpdateTempPressDensAmb(tstRslt);
/// Main results
tstRslt.MethodClass = TbfComponents.FindComponent(test.Method).ClassName;
tstRslt.StartTime = TestStartTime;
tstRslt.EndTime = TestEndTime;
tstRslt.FlowSetTime = flowSetTime;
tstRslt.TestTime = cBrd.TestTime; /// [s] measurement time
tstRslt.TimeBtwnMassMsrmnts = tMass2 - tMass1;
double massOfEvaporatedWater = (double)tstRslt.TimeBtwnMassMsrmnts * outPath.Scale.EvaporationRate(tstRslt.TempDivMean);
tstRslt.PulsesMaster = Convert.ToDouble(cBrd.RefPulses); /// Pulses of the master flow meter (test total)
tstRslt.MassStartRaw = StartMass.Val;
tstRslt.MassStart = Config.Formulas.CorrectedValue(tstRslt.MassStartRaw, scale.Corrections);
tstRslt.MassEndRaw = EndMass.Val;
tstRslt.MassEnd = Config.Formulas.CorrectedValue(tstRslt.MassEndRaw, scale.Corrections);
tstRslt.FlowMass = 3600.0 * (tstRslt.MassEnd - tstRslt.MassStart + massOfEvaporatedWater) / tstRslt.TestTime; /// [kg/h]
tstRslt.FlowVolume = 3.6 * LtrPerRefPulse * tstRslt.PulsesMaster / tstRslt.TestTime; /// [m3/h]
tstRslt.Buoyancy = Config.Formulas.Buoyancy();
tstRslt.VolumeCTV = 1000 * tstRslt.Buoyancy * (tstRslt.MassEnd - tstRslt.MassStart + massOfEvaporatedWater) / tstRslt.DensityLine; /// [l] commercially true volume
if ((outPath.Diverter != null) && (tstRslt.TestTime > float.Epsilon))
{
tstRslt.TestTimeCorrection = outPath.Diverter.TestTimeCorrection(tstRslt.FlowVolume);
tstRslt.VolumeCTV *= tstRslt.TestTime + tstRslt.TestTimeCorrection;
tstRslt.VolumeCTV /= tstRslt.TestTime;
}
tstRslt.VolumeMaster = LtrPerRefPulse * tstRslt.PulsesMaster; /// [l] volume from the master flow meter
tstRslt.ConstMasterRaw = outPath.FlowMeter.LtrPerPulse; /// Uncorrected master flowmeter coefficient
tstRslt.ConstMasterCorr = outPath.FlowMeter.LtrPerPulseCorrected(tstRslt.FlowVolume, rangeIx); /// Corrected master pulses per liter
tstRslt.ConstMaster = (tstRslt.VolumeMaster == 0) ? tstRslt.ConstMasterCorr : (LtrPerRefPulse * tstRslt.VolumeCTV / tstRslt.VolumeMaster);
/// Calculated master pulses per liter
tstRslt.ErrorMaster = Config.Formulas.ErrorFromVolumes(tstRslt.VolumeMaster, tstRslt.VolumeCTV);
tstRslt.FlowMean = (float)RefFlowStat.Average;
tstRslt.FlowStart = (float)RefFlowStat.First;
tstRslt.FlowEnd = (float)RefFlowStat.Last;
tstRslt.FlowMin = (float)RefFlowStat.Min;
tstRslt.FlowMax = (float)RefFlowStat.Max;
tstRslt.DiverterStart = outPath.Diverter.SwitchTimeStart.Val;
tstRslt.DivStart10 = 0;
tstRslt.DivStart50 = 0;
tstRslt.DivStart90 = 0;
tstRslt.DiverterEnd = outPath.Diverter.SwitchTimeEnd.Val;
tstRslt.DivEnd90 = 0;
tstRslt.DivEnd50 = 0;
tstRslt.DivEnd10 = 0;
log.DebugFormat("Diverter switch time [s]: Start: {0}ms ({1} {2} {3}) End: {4}ms ({5} {6} {7})",
(tstRslt.DiverterStart * 1000).ToString("F0"), tstRslt.DivStart10, tstRslt.DivStart50, tstRslt.DivStart90,
(tstRslt.DiverterEnd * 1000).ToString("F0"), tstRslt.DivEnd90, tstRslt.DivEnd50, tstRslt.DivEnd10);
long infoFlags = 0;
tstRslt.ErrorFlags = (ErrorFlagsComp != null) ? ErrorFlagsComp.GetErrorFlags(tstRslt, true, false, tstRslt.DiverterStart, tstRslt.DiverterEnd, out infoFlags) : 0;
tstRslt.InfoFlags = infoFlags;
if (compoundTestParams != null)
{
///
/// Compound meters
///
for (int i = 0; i < BatchRslts.WMPositionsCount; i++)
{
if (!test.IsPartCompatible(Utils.PartNr(i + 1, BatchRslts.Batch.Compound))) continue;
Results.Entities.MeterTestRslt mainMeterRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.CompoundMain);
Results.Entities.MeterTestRslt auxMeterRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.CompoundAux);
for (int isAux = 0; isAux <= 1; isAux++) /// 0=main, 1=aux
{
GenericDevices.IRegReader regReader = sensPath.RegisterReaders[2 * i + isAux];
Results.Entities.MeterTestRslt meterRslt = (isAux == 0) ? mainMeterRslt : auxMeterRslt;
if (meterRslt != null && regReader != null)
{
meterRslt.RegReaderType = (int)regReader.RegisterReaderType;
meterRslt.PulsesPerLiter = regReader.PulsesPerLtr;
/// Optionally supress pulses from the large water meter
meterRslt.PulsesMeter = (isAux == 0 && compoundTestParams.SupressTrills) ? 0 : Convert.ToDouble(regReader.WMPulses);
meterRslt.PulsesMaster = Convert.ToDouble(regReader.WMRefPulses);
meterRslt.TestTime = cBrd.TestTimeWM(regReader.Position);
meterRslt.VolumeStart = 0;
meterRslt.VolumeEnd = 0;
meterRslt.VolumeRef = tstRslt.VolumeCTV;
meterRslt.VolumeMeter = meterRslt.PulsesMeter * regReader.LtrsPerPulse; /// liter
if (meterRslt.PulsesMaster != 0)
{
meterRslt.VolumeMeter *= (tstRslt.PulsesMaster / meterRslt.PulsesMaster);
}
meterRslt.Error = Config.Formulas.ErrorFromVolumes(meterRslt.VolumeMeter, tstRslt.VolumeCTV); /// Main/Aux meter error is not usedfor evaluation
}
}
Results.Entities.MeterTestRslt compoundMeterRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.Compound);
if (compoundMeterRslt != null && mainMeterRslt != null && auxMeterRslt != null)
{
compoundMeterRslt.VolumeRef = tstRslt.VolumeCTV;
compoundMeterRslt.VolumeMeter = mainMeterRslt.VolumeMeter + auxMeterRslt.VolumeMeter;
compoundMeterRslt.PulsesMaster = tstRslt.PulsesMaster;
compoundMeterRslt.TestTime = tstRslt.TestTime;
compoundMeterRslt.Error = Config.Formulas.ErrorFromVolumes(compoundMeterRslt.VolumeMeter, compoundMeterRslt.VolumeRef);
compoundMeterRslt.Passed = (compoundMeterRslt.Error >= test.GetErrLimLo(tstRslt.VolumeCTV, tstRslt.TestTime) + test.Uncertainty)
&& (compoundMeterRslt.Error <= test.GetErrLimHi(tstRslt.VolumeCTV, tstRslt.TestTime) - test.Uncertainty)
&& (tstRslt.ErrorFlags == 0);
mainMeterRslt.Passed = auxMeterRslt.Passed = compoundMeterRslt.Passed;
mainMeterRslt.TestDone = auxMeterRslt.TestDone = compoundMeterRslt.TestDone = true;
tstRslt.TestDone = true;
}
}
}
else if (heatMetersTestParams != null)
{
///
/// Heat meters
///
tstRslt.RefEnergy = Energy.Sum * tstRslt.VolumeCTV / VolumeForEnergy.Sum; /// [J] = [J] * [l] / [l]
tstRslt.Custom1 = (float)TempRefHiStat.Average;
tstRslt.Custom2 = (float)TempRefHiStat.First;
tstRslt.Custom3 = (float)TempRefHiStat.Last;
tstRslt.Custom4 = (float)TempRefHiStat.Min;
tstRslt.Custom5 = (float)TempRefHiStat.Max;
tstRslt.Custom6 = (float)TempRefLoStat.Average;
tstRslt.Custom7 = (float)TempRefLoStat.First;
tstRslt.Custom8 = (float)TempRefLoStat.Last;
tstRslt.Custom9 = (float)TempRefLoStat.Min;
tstRslt.Custom10 = (float)TempRefLoStat.Max;
for (int i = 0; i < BatchRslts.WMPositionsCount; i++)
{
if (!test.IsPartCompatible(Utils.PartNr(i + 1, BatchRslts.Batch.Compound))) continue;
Results.Entities.MeterTestRslt volumeRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.HeatMeterVolume);
Results.Entities.MeterTestRslt energyRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.HeatMeterEnergy);
Rig.GenericDevices.IRegReader volumeRegReader =
(sensPath.RegisterReaders.Length > 2 * i) ? sensPath.RegisterReaders[2 * i] : null;
Rig.GenericDevices.IRegReader energyRegReader =
(sensPath.RegisterReaders.Length > 2 * i + 1) ? sensPath.RegisterReaders[2 * i + 1] : null;
if (volumeRslt != null && volumeRegReader != null)
{
volumeRslt.PulsesPerLiter = volumeRegReader.PulsesPerLtr; /// [l ^ -1]
volumeRslt.PulsesMeter = Convert.ToDouble(volumeRegReader.WMPulses);
volumeRslt.PulsesMaster = Convert.ToDouble(volumeRegReader.WMRefPulses);
volumeRslt.VolumeStart = 0;
volumeRslt.VolumeEnd = 0;
volumeRslt.VolumeMeter = volumeRslt.PulsesMeter * volumeRegReader.LtrsPerPulse; /// [l]
volumeRslt.VolumeRef = volumeRslt.PulsesMaster * tstRslt.ConstMaster; /// [l]
volumeRslt.TestTime = cBrd.TestTimeWM(i + 1); /// [s]
volumeRslt.Error = Config.Formulas.ErrorFromVolumes(volumeRslt.VolumeMeter, volumeRslt.VolumeRef);
volumeRslt.Passed = !heatMetersTestParams.EvaluateVolume ||
((volumeRslt.Error >= test.GetErrLimLo(tstRslt.VolumeCTV, tstRslt.TestTime) + test.Uncertainty) &&
(volumeRslt.Error <= test.GetErrLimHi(tstRslt.VolumeCTV, tstRslt.TestTime) - test.Uncertainty) &&
(tstRslt.ErrorFlags == 0));
volumeRslt.TestDone = true;
tstRslt.TestDone = true;
}
if (energyRslt != null && energyRegReader != null)
{
energyRslt.PulsesPerLiter = energyRegReader.PulsesPerLtr; /// [kWh ^ -1]
energyRslt.PulsesMeter = Convert.ToDouble(energyRegReader.WMPulses);
energyRslt.PulsesMaster = Convert.ToDouble(energyRegReader.WMRefPulses);
energyRslt.VolumeStart = 0;
energyRslt.VolumeEnd = 0;
energyRslt.VolumeRef = tstRslt.RefEnergy * (energyRslt.PulsesMaster / tstRslt.PulsesMaster); /// [J]
energyRslt.VolumeMeter = energyRslt.PulsesMeter * Config.Units.ConvertFrom(Config.Unit.kWh, energyRegReader.LtrsPerPulse); /// [J]
energyRslt.TestTime = cBrd.TestTimeWM(i + 1); /// [s]
energyRslt.Error = Config.Formulas.ErrorFromVolumes(energyRslt.VolumeMeter, energyRslt.VolumeRef);
energyRslt.Passed = (energyRslt.Error >= heatMetersTestParams.ErrorLimitLo)
&& (energyRslt.Error <= heatMetersTestParams.ErrorLimitHi)
&& (tstRslt.ErrorFlags == 0);
energyRslt.TestDone = true;
tstRslt.TestDone = true;
}
}
}
else
{
///
/// Single meters
///
for (int i = 0; i < BatchRslts.WMPositionsCount; i++)
{
if (!test.IsPartCompatible(Utils.PartNr(i + 1, BatchRslts.Batch.Compound))) continue;
/// MetersKind.Single meters
Results.Entities.MeterTestRslt meterRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.Single);
GenericDevices.IRegReader regReader = sensPath.RegisterReaders[i];
GenericDevices.IRegReaderDatastream dstrReader = regReader as GenericDevices.IRegReaderDatastream;
TestMethods.iPerlCommunication.iPerlHead.IperlHead iPerl = regReader as TestMethods.iPerlCommunication.iPerlHead.IperlHead;
GenericDevices.IRegReaderLiveCamera cameraRoi = regReader as GenericDevices.IRegReaderLiveCamera;
if (meterRslt != null && regReader != null)
{
meterRslt.RegReaderType = (int)regReader.RegisterReaderType;
meterRslt.PulsesPerLiter = regReader.PulsesPerLtr;
meterRslt.PulsesMeter = Convert.ToDouble(regReader.WMPulses);
if (dstrReader != null)
{
meterRslt.TimestampStart = dstrReader.TimestampSecStart;
meterRslt.TimestampEnd = dstrReader.NoSamples ? (dstrReader.TimestampSecStart + tstRslt.TestTime) : dstrReader.TimestampSecEnd;
meterRslt.TestTime = meterRslt.TimestampEnd - meterRslt.TimestampStart;
meterRslt.VolumeStart = dstrReader.VolumeLtrStart; /// liter
meterRslt.VolumeEnd = dstrReader.VolumeLtrEnd; /// liter
meterRslt.VolumeMeter = Math.Abs(dstrReader.VolumeLtrEnd - dstrReader.VolumeLtrStart);
meterRslt.VolumeRef = tstRslt.VolumeCTV * meterRslt.TestTime / tstRslt.TestTime;
meterRslt.PulsesMaster = tstRslt.PulsesMaster * meterRslt.TestTime / tstRslt.TestTime;
if (iPerl != null)
{
if (iPerl.ResultCode != 0 && (meterRslt.WaterMeter.ResultCode & (int)Results.Entities.ResultCode.OptoErrorCodeMask) == 0)
{
meterRslt.WaterMeter.ResultCode |= iPerl.ResultCode;
}
#if IPERL
meterRslt.WaterMeter.CalibFactor = iPerl.CalibFactor;
#endif
iPerl.LastTestResult2 = iPerl.LastTestResult; /// Save shift previous test result
iPerl.LastTestResult = meterRslt; /// Save this test result
}
}
else if (cameraRoi != null)
{
meterRslt.TimestampStart = cameraRoi.TimestampStart; /// second
meterRslt.TimestampEnd = cameraRoi.TimestampEnd; /// second
meterRslt.VolumeStart = cameraRoi.VolumeStart; /// liter
meterRslt.VolumeEnd = cameraRoi.VolumeEnd; /// liter
meterRslt.VolumeMeter = cameraRoi.VolumeEnd - cameraRoi.VolumeStart; /// liter
if (meterRslt.VolumeMeter != 0)
{
/// Normal measurement with camera
meterRslt.TestTime = cameraRoi.TimestampEnd - cameraRoi.TimestampStart; /// second
meterRslt.VolumeRef = tstRslt.VolumeCTV * meterRslt.TestTime / tstRslt.TestTime;
meterRslt.PulsesMaster = tstRslt.PulsesMaster * meterRslt.TestTime / tstRslt.TestTime;
}
else
{
/// None or one pulse from the water meter using camera
meterRslt.TestTime = tstRslt.TestTime;
meterRslt.VolumeRef = tstRslt.VolumeCTV;
meterRslt.PulsesMaster = tstRslt.PulsesMaster;
}
}
else
{
meterRslt.PulsesMaster = Convert.ToDouble(regReader.WMRefPulses);
meterRslt.VolumeStart = 0; /// liter
meterRslt.VolumeEnd = 0; /// liter
meterRslt.VolumeMeter = meterRslt.PulsesMeter * regReader.LtrsPerPulse; /// liter
///
if (regReader.WMPulses >= 1)
{
/// Normal measurement
meterRslt.TestTime = cBrd.TestTimeWM(regReader.Position);
meterRslt.VolumeRef = meterRslt.PulsesMaster * tstRslt.ConstMaster; /// liter
}
else
{
/// None or one pulse from the water meter
meterRslt.TestTime = tstRslt.TestTime;
meterRslt.VolumeRef = tstRslt.VolumeCTV; /// liter
}
}
meterRslt.Error = Config.Formulas.ErrorFromVolumes(meterRslt.VolumeMeter, meterRslt.VolumeRef);
meterRslt.Passed = (meterRslt.Error >= test.GetErrLimLo(tstRslt.VolumeCTV, tstRslt.TestTime) + test.Uncertainty)
&& (meterRslt.Error <= test.GetErrLimHi(tstRslt.VolumeCTV, tstRslt.TestTime) - test.Uncertainty)
&& (tstRslt.ErrorFlags == 0);
meterRslt.TestDone = true;
tstRslt.TestDone = true;
}
}
}
tstRslt.Components = Results.Entities.Components.UpdateList(BatchRslts.ComponentsList,
new Results.Entities.Components((BenchInfo != null) ? BenchInfo.TestBenchId : 1,
(BenchInfo != null) ? BenchInfo.TestBenchName : "testbench",
inPath.Pump != null ? inPath.Pump.Name : string.Empty,
outPath.FlowMeter != null ? outPath.FlowMeter.Name : string.Empty,
cBrd.Devices.Scale.Name,
outPath.RegValve != null ? outPath.RegValve.Name : string.Empty,
outPath.Diverter != null ? outPath.Diverter.Name : string.Empty));
/// Update water meter error flags
if (ErrorFlagsComp != null)
{
if (BatchRslts.Batch != null && BatchRslts.Batch.WaterMeters != null)
{
for (int i = 0; i < BatchRslts.WMPositionsCount; i++)
{
if (BatchRslts.Batch.WaterMeters[i] != null && !BatchRslts.Batch.WaterMeters[i].Disabled)
{
long wmInfoFlags;
BatchRslts.Batch.WaterMeters[i].ErrorFlags = ErrorFlagsComp.GetWMtrErrorFlags(BatchRslts.Batch.WaterMeters[i].MeterTestRslts, out wmInfoFlags);
BatchRslts.Batch.WaterMeters[i].InfoFlags = wmInfoFlags;
}
}
}
}
/// Update results
Bridge.OnTestCompleted(this, new TestCompletedEventArgs(testName, tstRslt));
}
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.TransitionAfter));
/// Append the results to the CSV-file
allResults.Info(TestResult2CsvLine(testName, test.Part));
stopTest:
StopRecordingStatistics(); /// Make sure graph files are closed
///
/// Quit this sequence
///
if (isLastRepetition || retVal == Event.UiCmdStop
|| retVal == Event.OpArgumentError
|| retVal == Event.Error
|| retVal == Event.ConfigurationError)
{
cBrd.Stop(false);
}
stopTestWOStoppingDivGateEtc:
return new List { retVal };
}
IList Simulate1(Config.Entities.Test test, int repetitionNr, bool isLastRepetition,
Compound.CombinedTestParams compoundTestParams,
HeatMeters.TestParams heatMetersTestParams)
{
///
/// Test method simulation
///
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
foreach (var rr in sensPath.RegisterReaders)
{
GenericDevices.IHasTestName readerWithTstName = rr as GenericDevices.IHasTestName;
if (readerWithTstName != null)
{
readerWithTstName.TestName = test.Name;
readerWithTstName.TestRepeats = test.Repeats;
readerWithTstName.RepetitionNr = repetitionNr;
}
}
State.Create(string.Format("{0}({1}) : Reading watermeters", test.Method, test.Name))
.AddOperation(checkUiOp)
.EnterState();
StateMachine.WaitRunDevsRunOps();
StateMachine.WaitRunDevsRunOps();
if (compoundTestParams != null)
{
if (test.Name.ToLower().Contains("nok")) MakeSimulatedCompound(test, 1, test.Part, 4.7f, 0.9f);
else MakeSimulatedCompound(test, repetitionNr, test.Part, 0.7f, 1.0f);
}
else if (heatMetersTestParams != null)
{
MakeSimulatedHeatMeters(test, repetitionNr, test.Part, 1.5f, 1000000, heatMetersTestParams.ErrorLimitLo, heatMetersTestParams.ErrorLimitHi, heatMetersTestParams.EvaluateVolume);
}
else
{
float errorPctBase = -1.0f;
if (test.Name.ToLower().Contains("q3")) errorPctBase = -0.5f;
else if (test.Name.ToLower().Contains("q2")) errorPctBase = 0.5f;
else if (test.Name.ToLower().Contains("q1")) errorPctBase = -5.1f;
MakeSimulated(test, repetitionNr, test.Part, errorPctBase + repetitionNr * 0.1f);
}
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Completed));
Bridge.OnTestCompleted(this, new TestCompletedEventArgs(test.Name, BatchRslts.GetTestRslt(Results.Utils.GetTestName(test.Name, 1, 1), 0)));
allResults.Info(TestResult2CsvLine(test.Name, 0)); /// Append the results to the CSV-file
//-------------------------------------------------------------------
Bridge.OnActivity(this, string.Format("{0} Simulation", test.Name));
//-------------------------------------------------------------------
State.Create(string.Format("{0}({1}) : Simulation", test.Method, test.Name))
.AddOperation(checkUiOp)
.EnterState();
IList e = StateMachine.WaitRunDevsRunOps();
return new List { TestAndLogUiCmdStop(test, e) ? Event.UiCmdStop : Event.Done };
}
IList Simulate2(Config.Entities.Test test, int repetitionNr, bool isLastRepetition,
Compound.CombinedTestParams compoundTestParams,
HeatMeters.TestParams heatMetersTestParams)
{
IList e;
Event retVal = Event.Done;
///
/// Test method with flow chart simulation
///
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
/// Simulate flow
StartNewStatistics(StateMachine.Time, BatchRslts.Batch.BatchNr, test.Name, repetitionNr, 0);
IntBox remainingTime = new IntBox((int)test.TestTime);
State.Create(string.Format("{0}({1}) : Simulation", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(new Operations.TimerOp((int)test.TestTime, remainingTime))
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; break; }
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
if (remainingTime.Val > 60)
{
Bridge.OnActivity(this, string.Format("{0} ... {1} {2} {3} {4}", Strings.Test_in_progress, remainingTime.Val / 60, "min", remainingTime.Val % 60, Strings.sec));
}
else
{
Bridge.OnActivity(this, string.Format("{0} ... {1} s", Strings.Test_in_progress, remainingTime.Val));
}
//------------------------------------------------
RefFlow.Val = (1.0 + 0.2 * Math.Sin(2 * Math.PI * (float)remainingTime.Val / test.TestTime)) * (test.Qfrom + test.Qto) / 2.0;
PressUp.Val = 2.7f;
PressDown.Val = 2.2f;
UpdateAllStatistics(StateMachine.Time);
}
while (!e.Contains(Event.TimerExpired));
StopRecordingStatistics();
if (retVal != Event.UiCmdStop)
{
float errorPctBase = -1.0f;
if (test.Name.ToLower().Contains("q3")) errorPctBase = -0.5f;
else if (test.Name.ToLower().Contains("q2")) errorPctBase = 0.5f;
else if (test.Name.ToLower().Contains("q1")) errorPctBase = -5.1f;
MakeSimulated(test, repetitionNr, test.Part, errorPctBase + repetitionNr * 0.1f);
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Completed));
Bridge.OnTestCompleted(this, new TestCompletedEventArgs(test.Name, BatchRslts.GetTestRslt(Results.Utils.GetTestName(test.Name, 1, 1), 0)));
allResults.Info(TestResult2CsvLine(test.Name, 0)); /// Append the results to the CSV-file
}
return new List { retVal }; /// default 'retVal' value is Event.Done
}
}
}