Milan Hanajik
|
bab677c5c2
|
PressMtrDelta added to BenchPath, PressDeltaXyz added to TestRslt, test methods modified, ver. 2.12.373
|
2016-10-18 19:14:01 +02:00 |
|
Milan Hanajik
|
d1fb0e0f0a
|
T warm/cold lo/hi renamed to T hi/lo min/max
|
2016-10-18 17:27:24 +02:00 |
|
Milan Hanajik
|
08d854f6f8
|
Modbus.PressureMeter.Meret implemented, ver. 2.11.372
|
2016-10-18 17:27:22 +02:00 |
|
Milan Hanajik
|
93e8328940
|
IModbus and Modbus modification : Supports receiving telegrams from multiple devices.
|
2016-10-18 17:27:08 +02:00 |
|
Milan Hanajik
|
03c027ab33
|
LogProcessDataHeatMeters, ver. 2.11.371
|
2016-10-18 11:49:32 +02:00 |
|
Milan Hanajik
|
14de767c52
|
Modbus.Common.Modbus.SendMessage(byte deviceAddress, byte function, ...) function added.
|
2016-10-18 11:31:17 +02:00 |
|
Milan Hanajik
|
9e90d3a93f
|
DeviceTest program functional, runs operation Modbus.PressureMeter.Meret.ReadPressureOp(...)
|
2016-10-18 11:30:02 +02:00 |
|
Milan Hanajik
|
97fbcbbf58
|
Malta WSD25 : Bug fix for reference flowmeter with idx = 8 (EtCalib[] array size increased to 9), ver. 2.11.370
|
2016-10-17 16:06:50 +02:00 |
|
Milan Hanajik
|
1b77c903f7
|
Component for Malta upgraded, ver. 2.11.369
|
2016-10-17 08:48:58 +02:00 |
|
Milan Hanajik
|
588d16caf9
|
ver. 2.11.368
|
2016-10-14 16:17:56 +02:00 |
|
Milan Hanajik
|
790364832d
|
Transition sequences can be renamed and deleted.
|
2016-10-13 18:06:13 +02:00 |
|
Milan Hanajik
|
0fb3a74879
|
Feeding regulation valves functionality implemented, ver. 2.11.367
|
2016-10-13 16:08:29 +02:00 |
|
Milan Hanajik
|
45e0f50562
|
Elde.RegulValve supports 'ReTryCommands' parameter (default = false), ver. 2.11.365
|
2016-10-13 16:08:15 +02:00 |
|
Milan Hanajik
|
caf43fedb3
|
IRegulValve change, regulation valves support Category, Category saved in settings, used in Feeding Paths UI, not used in tests yet, ver. 2.11.364
|
2016-10-12 15:47:45 +02:00 |
|
Milan Hanajik
|
1388f459fe
|
Malta WSD25 : Component upgraded, ver. 2.10.363
|
2016-10-12 09:55:44 +02:00 |
|
Milan Hanajik
|
dddfc4bed5
|
Bug-fixes in FlyingStart and FlyingStartMassCollection heat meters, T ref warm and T ref cold statistics, ver. 2.10.362
|
2016-10-12 01:23:38 +02:00 |
|
Milan Hanajik
|
2057cc6b73
|
Malta WSD25 component upgraded, MERET addresses array size changed to 12, ver. 2.10.361
|
2016-10-11 17:01:33 +02:00 |
|
Milan Hanajik
|
76dbf4e216
|
Length of array for MERET addresses is 11.
|
2016-10-11 15:24:18 +02:00 |
|
Milan Hanajik
|
1fc129117f
|
Output.FileWriters.Basic.HeatMeters
|
2016-10-11 14:55:16 +02:00 |
|
Milan Hanajik
|
f866f5fb2c
|
Output.FileWriters.Enhanced.HeatMeters
|
2016-10-11 14:27:28 +02:00 |
|
Milan Hanajik
|
38d6016aec
|
DataEntry.HeatMeters6 component added.
|
2016-10-11 13:05:40 +02:00 |
|
Milan Hanajik
|
b3a2c3a0fc
|
FlyingStart, FlyingStartMassCollection and CombinedWithDetection methods support Simulation mode, ver. 2.10.360
|
2016-10-11 12:53:17 +02:00 |
|
Milan Hanajik
|
c84fd8089a
|
FlyingStart and FlyingStartMassCollection methods: 'Begin cycle' dialog closed before 'Heat meters prompt message' is displayed.
|
2016-10-11 09:10:33 +02:00 |
|
Milan Hanajik
|
2e4c59d3b5
|
Keithley Multimeter supports simulation mode.
|
2016-10-11 09:09:04 +02:00 |
|
Milan Hanajik
|
5f21b5ab26
|
ErrorLimitHi, ErrorLimitLo, EvaluateVolume test parameters added to all heat meters methods.
|
2016-10-10 14:35:59 +02:00 |
|
Milan Hanajik
|
f8331c1c1c
|
Heat meters : Prompt message does not stop the sequence, disappears when conditions met, ver. 2.10.359
|
2016-10-10 14:23:20 +02:00 |
|
Milan Hanajik
|
3c15dbab9e
|
Bug fixes in heat meter testing using pulses, Flying start and Flying start mass collection methods, ver. 2.10.358
|
2016-10-10 11:35:45 +02:00 |
|
Milan Hanajik
|
d5eb20854f
|
Displaying heat meter test results on screen fixed, ver. 2.10.357
|
2016-10-07 18:19:17 +02:00 |
|
Milan Hanajik
|
438028506e
|
Flows are internally stored and processed in double variables (except of Qfrom, Qto, flowmeter nominal flow)
|
2016-10-07 16:22:36 +02:00 |
|
Milan Hanajik
|
010afcd1e4
|
Temperatures are internally stored and processed in double variables (except of ambient temp.).
|
2016-10-07 15:41:27 +02:00 |
|
Milan Hanajik
|
7df9333fba
|
Statistics return doubles instead of float, casting is done just when writing to entities.
|
2016-10-07 14:46:14 +02:00 |
|
Milan Hanajik
|
4160420844
|
Masses are stored in double variables everywhere.
|
2016-10-07 14:06:54 +02:00 |
|
Milan Hanajik
|
9f2e8407a0
|
Modbus.PressureMeter.Meter component added, ver. 2.10.357
|
2016-10-07 11:59:13 +02:00 |
|
Milan Hanajik
|
45c64ae44b
|
Modbus does not use an extra worker thread.
|
2016-10-07 11:55:44 +02:00 |
|
Milan Hanajik
|
e8748bab70
|
(1) QuidoRS dead code clean-up, (2) Elde.PressureMeter units conversion clean-up.
|
2016-10-07 11:55:03 +02:00 |
|
Milan Hanajik
|
c30f905893
|
SLM50 : Bugfix in energy calculation in FlyingStart and FlyingStartMassCollection methods, ver. 2.10.356
|
2016-10-07 10:09:38 +02:00 |
|
Milan Hanajik
|
8932c232e2
|
Malta : Another minor change, ver. 2.10.355
|
2016-10-06 14:26:08 +02:00 |
|
Milan Hanajik
|
295e96098c
|
Malta : Minor changes, extended range of Id-s for flow meters and pressure meters, ver.2.10.354
|
2016-10-06 14:02:16 +02:00 |
|
Milan Hanajik
|
dff3a1aff7
|
Changes in 'master' for Malta-WSD25, ver. 2.10.353
|
2016-10-06 11:54:38 +02:00 |
|
Milan Hanajik
|
c497c02ef9
|
Heat meters support for measurement with pulses, change in ResultsDB.MeterTestRslt, ver. 2.10.352
|
2016-10-06 10:11:13 +02:00 |
|
Milan Hanajik
|
f51360c23d
|
Upgraded to NHibernate 4.0.4, IesiCollections 4.0.0, FluentNHibernate 2.0.3, MySQL.Data, all are using.Net 4.0 now, ver. 2.10.351
|
2016-10-05 11:23:06 +02:00 |
|
Milan Hanajik
|
2286877fad
|
Test method names cleaned up.
|
2016-09-26 11:08:16 +02:00 |
|
Milan Hanajik
|
a1810baffa
|
ver. 2.10.350
|
2016-09-23 15:51:12 +02:00 |
|
Milan Hanajik
|
6bb45ccc25
|
Support for GENESIS added, ver. 2.10.349
|
2016-09-22 08:50:22 +02:00 |
|
Milan Hanajik
|
5f7c0c82e7
|
Bug fix: summaryResults, allResults: ambient pressure in mbar, water pressure in kPa.
|
2016-09-14 13:05:26 +02:00 |
|
Milan Hanajik
|
1d964e5fcc
|
Czech resources added to ResultsBrowser.
|
2016-09-08 08:33:44 +02:00 |
|
Milan Hanajik
|
85ca2420bd
|
Bugs in printers caused by a change of ambient pressure representation fixed.
|
2016-09-07 18:29:25 +02:00 |
|
Milan Hanajik
|
c835fe5551
|
Keithley.TempMeter resistance 0 < R < 2000 Ohm
|
2016-08-26 11:36:42 +02:00 |
|
Milan Hanajik
|
9563dbdb6f
|
Using ITS-27 coefficients possible as well.
|
2016-08-25 17:36:27 +02:00 |
|
Milan Hanajik
|
3666752414
|
Some Keithley.TempMeter parameters (ITS-90, certificate) are accessible through Bench -> Metrology dialog.
|
2016-08-25 15:54:21 +02:00 |
|