Milan Hanajik
3ebeb4a0dc
Sensus Oracle Database support (stub) added, version 1.5.85
2015-08-19 14:17:02 +02:00
Milan Hanajik
33963ec8cf
Version 1.5.84. Reading registers, scales, temperature, pressure, ... during test done in one state in the sequence.
...
Many changes in TestMethods.iPerlCommunication and WaterMeters.iPerl.WaterMeter. iPerl measurement with opto-data works OK.
Logging in State changed, ...
2015-08-19 13:04:47 +02:00
Milan Hanajik
fa6b99b980
StateMachine timing period is 2 seconds for iPerlST bench, 1 second for other all benches.
2015-08-19 13:00:00 +02:00
Milan Hanajik
22c652ad24
Bugfix: Reading of water meter pulses with overflow avoidance of 16-bit counters was not implemented correctly.
2015-08-19 12:56:28 +02:00
Milan Hanajik
c376e67eab
Watchdog function of QuidoRS device implemented permanently on output bit #4 , mask 0x0010.
2015-08-19 12:53:34 +02:00
Milan Hanajik
e349d6811d
'CommErr error' codes from RFID comm. routines instead of 'bool success'.
2015-08-17 16:02:30 +02:00
Milan Hanajik
ed4afff0b2
Changes: iPerl RR is reset at the beginnign of FlyingStartMassCollection test. etc.
2015-08-16 22:00:02 +02:00
Milan Hanajik
713fd9d0ae
Raw opto telegram added, TODO: complete OptoTelegramRaw implementation.
2015-08-16 20:34:06 +02:00
Milan Hanajik
5db53ca6e3
Generic improvements: process page fixes, error format F2 or F3 (master), results page fixes, Comet ambient serial parameters (comment).
2015-08-16 19:58:43 +02:00
Milan Hanajik
e302cb9335
OptoTelegram serial port data parsing, OptoData and RfidData logging, opto-measurement ready to be tested.
2015-08-16 12:54:44 +02:00
Milan Hanajik
a6aa6739ad
Modbus modification to support simulation mode.
2015-08-15 21:11:01 +02:00
Milan Hanajik
ee044e3dd7
More iPerlCommunication changes: read/write Q2 correction factors from/to memory, cleanup of all functions.
2015-08-15 21:09:31 +02:00
Milan Hanajik
5f5ac87f42
iPerlCommunication: testModeConfig parsed and set, correct wm.Disabled behavior.
2015-08-14 20:18:44 +02:00
Milan Hanajik
f85fbd0b55
Problems when passing flowmeter/diverter info to test start by SendCommand() fixed, version 1.5.77.
2015-08-14 18:14:08 +02:00
Milan Hanajik
4166bf8d87
More iPerl communication
2015-08-14 14:33:36 +02:00
Milan Hanajik
bf376b4ff0
iPerlST configuration changes, etc., version 1.5.76
2015-08-14 12:01:00 +02:00
Milan Hanajik
7e28381df5
Working on iPerlCommunication activities required for the production cycle.
2015-08-14 11:39:28 +02:00
Milan Hanajik
faeb940134
Communication with 40 iPerl meters in 1 worker thread.
2015-08-13 08:35:34 +02:00
Milan Hanajik
6440a8950c
Communication in 4 parallel threads (4 boards, 4 RFID ports).
2015-08-12 16:05:06 +02:00
Milan Hanajik
e569a80ec2
iPerl component updated + interface change: ulong DigitalInputs (it was uint), iPerlCommunication test method added, etc, version 1.5.75.
2015-08-12 14:55:35 +02:00
Milan Hanajik
40a43e46b4
Changes required for 'Zapiska'.
2015-08-02 17:23:47 +02:00
Milan Hanajik
7c1b713780
Zapiska and WaterMeterPL added, BenchInfo.Polska added, IBenchInfo infroduced, Version 1.5.74
2015-08-02 14:09:24 +02:00
Milan Hanajik
52c5679c00
iPerl test - iPerlAdjustment test method.
2015-08-01 21:24:32 +02:00
Milan Hanajik
5997a494bd
OptoreeceivedEventArgs added to WaterMeters.iPerl
2015-07-31 19:45:10 +02:00
Milan Hanajik
f2da177517
Modbus and QuidoRS components added
...
WaterMeters folder created, WaterMeter component relocated within the project, iPerl component added
WaterMeters.iPerl implements IRegisterReader interface, TODO: Implement WaterMeter.ReadPulses( ) function
iPerlAdjustment test method added
2015-07-31 19:18:56 +02:00
Milan Hanajik
6ecae88518
iPerl ST support via define IPERLST, component added
2015-07-29 17:48:09 +02:00
Milan Hanajik
a85af2bec8
ProcessTabPageCtrl24 items visibility for compound meters corrected.
2015-07-09 17:49:22 +02:00
Milan Hanajik
95c05078de
Introduction of Program.CompoundWMsCount, fix in DataEntry.Combined.CycleBeginningForm, version 1.5.68.
2015-07-09 16:24:55 +02:00
Milan Hanajik
cca505fc2c
Last minute changes
2015-07-03 16:52:36 +02:00
Milan Hanajik
212d675514
Problem with virtual valves fixed. They were lost when a test was started/stopped, RRoute was used. Version 1.5.65.
2015-07-03 10:53:48 +02:00
Milan Hanajik
58f872c6f4
Bug fix in adjustment dialog for 24 watermeters, version 1.5.64.
2015-07-03 02:42:30 +02:00
Milan Hanajik
c981707d91
private variable name fixed
2015-07-02 17:30:40 +02:00
Milan Hanajik
5292088622
A new form for 24 water meters in adjustment dialog
2015-07-02 17:28:11 +02:00
Milan Hanajik
7b52921730
ValveEx bug fixes.
2015-07-01 16:44:52 +02:00
Milan Hanajik
c957e28c00
ValveEx bug fix
2015-07-01 16:31:32 +02:00
Milan Hanajik
55f42bb6cb
ValveEx related change
2015-07-01 15:50:31 +02:00
Milan Hanajik
46118e91e5
ValveEx related change
2015-07-01 15:28:28 +02:00
Milan Hanajik
e13b43586d
ValveEx component added.
2015-06-30 02:06:58 +02:00
Milan Hanajik
7b902e8ca3
IComponentFactory.DummyComponent() interface function added and implemented in all components.
2015-06-29 11:14:33 +02:00
Milan Hanajik
9c99799694
Control board component supports virtual valves masking (to be used in Torun, Fuzhou300)
2015-06-27 07:51:54 +02:00
Milan Hanajik
10694609b3
Torun simulation corrected, ValveBase cleanup, version 1.5.61.
2015-06-27 07:05:28 +02:00
Milan Hanajik
0cea24246c
Error message due to incorrect configuration is cleared after selecting another procedure/test.
...
Return value from WaitBeginFormClosed(..) changed from bool to enum UIFlowControl.
2015-06-25 04:48:28 +02:00
Milan Hanajik
01118ae924
Missing comment added
2015-06-25 04:48:27 +02:00
Milan Hanajik
02c235d164
Bug fixes in DataEntry/Standard24/CycleBeginningForm : crash in case LocalSettings.LastSNTexts were not initalized, ver. 1.5.60.
2015-06-25 04:48:24 +02:00
Milan Hanajik
38c4073632
Working on simulations for: Badger_Mala_Trat, Cevak_PT40_272, Torino50 and Torun_PT05_2015
...
- builds OK, flow and mass are simulated, reference counter does not count.
2015-06-25 04:47:59 +02:00
Milan Hanajik
ca78f36f8f
Default names when creating new components shortened.
2015-06-22 14:24:06 +02:00
Milan Hanajik
c3e4d1b317
Water meter pulses overflow is handled properly (only 16-bit HW counter is used)
2015-06-22 13:11:53 +02:00
Milan Hanajik
150777dafc
CEVAK component added, common code for CEVAK added, version 1.5.58.
2015-06-18 13:14:56 +02:00
Milan Hanajik
4fc9bab96b
More DataEntry.Combined changes: bool ShowCycleEndForm, no Units for volume, etc.
2015-06-12 21:37:48 +02:00
Milan Hanajik
06d55b287d
More DataEntry.Combined.CycleBaginningForm: combo boxes used, key-press processed, etc.
2015-06-12 20:50:06 +02:00