Commit Graph

97 Commits

Author SHA1 Message Date
Milan Hanajik
f85fbd0b55 Problems when passing flowmeter/diverter info to test start by SendCommand() fixed, version 1.5.77. 2015-08-14 18:14:08 +02:00
Milan Hanajik
bf376b4ff0 iPerlST configuration changes, etc., version 1.5.76 2015-08-14 12:01:00 +02:00
Milan Hanajik
e569a80ec2 iPerl component updated + interface change: ulong DigitalInputs (it was uint), iPerlCommunication test method added, etc, version 1.5.75. 2015-08-12 14:55:35 +02:00
Milan Hanajik
6ecae88518 iPerl ST support via define IPERLST, component added 2015-07-29 17:48:09 +02:00
Milan Hanajik
cca505fc2c Last minute changes 2015-07-03 16:52:36 +02:00
Milan Hanajik
212d675514 Problem with virtual valves fixed. They were lost when a test was started/stopped, RRoute was used. Version 1.5.65. 2015-07-03 10:53:48 +02:00
Milan Hanajik
7b52921730 ValveEx bug fixes. 2015-07-01 16:44:52 +02:00
Milan Hanajik
c957e28c00 ValveEx bug fix 2015-07-01 16:31:32 +02:00
Milan Hanajik
55f42bb6cb ValveEx related change 2015-07-01 15:50:31 +02:00
Milan Hanajik
46118e91e5 ValveEx related change 2015-07-01 15:28:28 +02:00
Milan Hanajik
e13b43586d ValveEx component added. 2015-06-30 02:06:58 +02:00
Milan Hanajik
7b902e8ca3 IComponentFactory.DummyComponent() interface function added and implemented in all components. 2015-06-29 11:14:33 +02:00
Milan Hanajik
9c99799694 Control board component supports virtual valves masking (to be used in Torun, Fuzhou300) 2015-06-27 07:51:54 +02:00
Milan Hanajik
ca78f36f8f Default names when creating new components shortened. 2015-06-22 14:24:06 +02:00
Milan Hanajik
c3e4d1b317 Water meter pulses overflow is handled properly (only 16-bit HW counter is used) 2015-06-22 13:11:53 +02:00
Milan Hanajik
150777dafc CEVAK component added, common code for CEVAK added, version 1.5.58. 2015-06-18 13:14:56 +02:00
Milan Hanajik
2b72e855f1 Diverter calibration wurks OK, TODO: Display transition, param.ref.flowm.
Version 1.5.57.
2015-06-12 19:52:29 +02:00
Milan Hanajik
2d64f91c9a Diverter test from Components -> Edit ... More 2015-06-12 19:34:41 +02:00
Milan Hanajik
79d819a501 Config change handler for Diverter, it should be possible to calibrate the analog input. 2015-06-12 16:39:57 +02:00
Milan Hanajik
ae3f3bb762 Elde.TempMeterInternal and Elde.PressureMeterInternal component added, version 1.4.43. 2015-05-21 18:17:28 +02:00
Milan Hanajik
d2b76cc58d Various bug fixe, ValveMove to flow repeted 1x, version 1.4.42 2015-05-21 16:39:18 +02:00
Milan Hanajik
3701731de8 More logging of SendCalibData(...). Version 1.4.38. 2015-05-20 17:02:03 +02:00
Milan Hanajik
ceb3de90bf Invalid configuration checked in StateMachine.GetPaths(...). More logging of mass display. 2015-05-20 16:18:54 +02:00
Milan Hanajik
18ee69f0db Torun bugfix: StatusP definition 2015-05-20 14:41:30 +02:00
Milan Hanajik
abfec8960d Pump power in % shown on the process screen 2015-05-15 16:44:13 +02:00
Milan Hanajik
843437a3b1 Completed MettlerToledo.Multi changes - ready for tests. 2015-05-07 20:07:53 +02:00
Milan Hanajik
21d0adb089 MettlerToledo scales moved one level down in the directory and namespace structure. 2015-05-07 16:11:07 +02:00
Milan Hanajik
fb4005afb7 Modifications for Torun 2015-05-05 17:20:36 +02:00
Milan Hanajik
f73863f758 Fixing behavior when more FM pumps share the same bit in Fuzhou300. More logging. 2015-04-18 13:31:31 +02:00
Milan Hanajik
2b2cc0f6f8 Diverter - preparation for calibration 2015-04-18 07:31:52 +02:00
Milan Hanajik
7f059d9c6f Program extended for BADGER_MALA_TRAT 2015-04-15 22:03:23 +02:00
Milan Hanajik
be78bb5ce0 Copyright message added to all cs-files 2015-04-15 20:32:56 +02:00
Milan Hanajik
5075bd6068 Regul. valve calibration completed and tested 2015-03-25 13:52:51 +01:00
Milan Hanajik
2902f36332 Work in progress: Diverter calibration 2015-03-24 02:45:36 +01:00
Milan Hanajik
1c46002aaa Regulation valve calibration fixed (feedback from ADC) 2015-03-24 02:45:09 +01:00
Milan Hanajik
4dfa98ff89 EtCalib[] array size for Torino corrected, index checked when accessing the array. 2015-03-24 02:44:13 +01:00
Milan Hanajik
6305c42f8b More program extensions to handle TORINO50 define. 2015-03-09 17:30:38 +01:00
Milan Hanajik
c2bccda07f Program extensions to handle TORINO50 define. 2015-03-09 15:47:59 +01:00
Milan Hanajik
93fd6a4f42 Support for FC protocol for Danfoss-VLT2800 and associated valve added - control part 2015-02-18 22:50:44 +01:00
Milan Hanajik
6eb384283a Regul. valve calibration uses 2 sec. pulses 2015-02-10 09:01:30 +01:00
Milan Hanajik
64253e1985 (1) RegulValveTandem wont appear in transition sequences, (2) Fixed RegulValveTandem initialization 2015-02-03 10:53:02 +01:00
Milan Hanajik
5806a65a0c RegulValveTandem op SetFlowOp should be functional, to be tested 2015-02-03 10:30:24 +01:00
Milan Hanajik
ab8aa61a29 Initial version with config UI, w/o functionality, added to the project 2015-02-03 08:06:20 +01:00
Milan Hanajik
94aa744fd4 Range of RegulValve indexes changed to 1..8, there are 6 RV-s in Pt200il 2015-02-02 22:49:08 +01:00
Milan Hanajik
0238a96975 More comments in SetFlowOp 2015-02-01 15:07:15 +01:00
Milan Hanajik
8aa9ed9f21 Bugfix for PT200IL: Test does not complete, Status bits definition changed 2015-01-26 13:15:47 +01:00
Milan Hanajik
d3532a2796 PumpFM,pumpTandem test parameter Power replaced by parameter Entities.Test.PumpPower,
all changes done except of UI changes (which can be done in more different ways)
2015-01-17 04:52:42 +01:00
Milan Hanajik
a0fb8000f0 PumpTandem can also be used as one of pumps in the tandem, PumpTandems can be chained 2015-01-16 07:40:04 +01:00
Milan Hanajik
b1c9e0d3b5 Bugfixes: (1) PumpTandem was missing a Mask to be used as Valve, (2) Column widths in results screen 2015-01-16 07:08:26 +01:00
Milan Hanajik
e07cf3c5d3 PumpTandem implemented for the case of two FM pumps with equal distribution of power 2015-01-16 05:24:34 +01:00