Milan Hanajik
9c99799694
Control board component supports virtual valves masking (to be used in Torun, Fuzhou300)
2015-06-27 07:51:54 +02:00
Milan Hanajik
ca78f36f8f
Default names when creating new components shortened.
2015-06-22 14:24:06 +02:00
Milan Hanajik
c3e4d1b317
Water meter pulses overflow is handled properly (only 16-bit HW counter is used)
2015-06-22 13:11:53 +02:00
Milan Hanajik
150777dafc
CEVAK component added, common code for CEVAK added, version 1.5.58.
2015-06-18 13:14:56 +02:00
Milan Hanajik
2b72e855f1
Diverter calibration wurks OK, TODO: Display transition, param.ref.flowm.
...
Version 1.5.57.
2015-06-12 19:52:29 +02:00
Milan Hanajik
2d64f91c9a
Diverter test from Components -> Edit ... More
2015-06-12 19:34:41 +02:00
Milan Hanajik
79d819a501
Config change handler for Diverter, it should be possible to calibrate the analog input.
2015-06-12 16:39:57 +02:00
Milan Hanajik
ae3f3bb762
Elde.TempMeterInternal and Elde.PressureMeterInternal component added, version 1.4.43.
2015-05-21 18:17:28 +02:00
Milan Hanajik
d2b76cc58d
Various bug fixe, ValveMove to flow repeted 1x, version 1.4.42
2015-05-21 16:39:18 +02:00
Milan Hanajik
3701731de8
More logging of SendCalibData(...). Version 1.4.38.
2015-05-20 17:02:03 +02:00
Milan Hanajik
ceb3de90bf
Invalid configuration checked in StateMachine.GetPaths(...). More logging of mass display.
2015-05-20 16:18:54 +02:00
Milan Hanajik
18ee69f0db
Torun bugfix: StatusP definition
2015-05-20 14:41:30 +02:00
Milan Hanajik
abfec8960d
Pump power in % shown on the process screen
2015-05-15 16:44:13 +02:00
Milan Hanajik
843437a3b1
Completed MettlerToledo.Multi changes - ready for tests.
2015-05-07 20:07:53 +02:00
Milan Hanajik
21d0adb089
MettlerToledo scales moved one level down in the directory and namespace structure.
2015-05-07 16:11:07 +02:00
Milan Hanajik
fb4005afb7
Modifications for Torun
2015-05-05 17:20:36 +02:00
Milan Hanajik
f73863f758
Fixing behavior when more FM pumps share the same bit in Fuzhou300. More logging.
2015-04-18 13:31:31 +02:00
Milan Hanajik
2b2cc0f6f8
Diverter - preparation for calibration
2015-04-18 07:31:52 +02:00
Milan Hanajik
7f059d9c6f
Program extended for BADGER_MALA_TRAT
2015-04-15 22:03:23 +02:00
Milan Hanajik
be78bb5ce0
Copyright message added to all cs-files
2015-04-15 20:32:56 +02:00
Milan Hanajik
5075bd6068
Regul. valve calibration completed and tested
2015-03-25 13:52:51 +01:00
Milan Hanajik
2902f36332
Work in progress: Diverter calibration
2015-03-24 02:45:36 +01:00
Milan Hanajik
1c46002aaa
Regulation valve calibration fixed (feedback from ADC)
2015-03-24 02:45:09 +01:00
Milan Hanajik
4dfa98ff89
EtCalib[] array size for Torino corrected, index checked when accessing the array.
2015-03-24 02:44:13 +01:00
Milan Hanajik
6305c42f8b
More program extensions to handle TORINO50 define.
2015-03-09 17:30:38 +01:00
Milan Hanajik
c2bccda07f
Program extensions to handle TORINO50 define.
2015-03-09 15:47:59 +01:00
Milan Hanajik
93fd6a4f42
Support for FC protocol for Danfoss-VLT2800 and associated valve added - control part
2015-02-18 22:50:44 +01:00
Milan Hanajik
6eb384283a
Regul. valve calibration uses 2 sec. pulses
2015-02-10 09:01:30 +01:00
Milan Hanajik
64253e1985
(1) RegulValveTandem wont appear in transition sequences, (2) Fixed RegulValveTandem initialization
2015-02-03 10:53:02 +01:00
Milan Hanajik
5806a65a0c
RegulValveTandem op SetFlowOp should be functional, to be tested
2015-02-03 10:30:24 +01:00
Milan Hanajik
ab8aa61a29
Initial version with config UI, w/o functionality, added to the project
2015-02-03 08:06:20 +01:00
Milan Hanajik
94aa744fd4
Range of RegulValve indexes changed to 1..8, there are 6 RV-s in Pt200il
2015-02-02 22:49:08 +01:00
Milan Hanajik
0238a96975
More comments in SetFlowOp
2015-02-01 15:07:15 +01:00
Milan Hanajik
8aa9ed9f21
Bugfix for PT200IL: Test does not complete, Status bits definition changed
2015-01-26 13:15:47 +01:00
Milan Hanajik
d3532a2796
PumpFM,pumpTandem test parameter Power replaced by parameter Entities.Test.PumpPower,
...
all changes done except of UI changes (which can be done in more different ways)
2015-01-17 04:52:42 +01:00
Milan Hanajik
a0fb8000f0
PumpTandem can also be used as one of pumps in the tandem, PumpTandems can be chained
2015-01-16 07:40:04 +01:00
Milan Hanajik
b1c9e0d3b5
Bugfixes: (1) PumpTandem was missing a Mask to be used as Valve, (2) Column widths in results screen
2015-01-16 07:08:26 +01:00
Milan Hanajik
e07cf3c5d3
PumpTandem implemented for the case of two FM pumps with equal distribution of power
2015-01-16 05:24:34 +01:00
Milan Hanajik
d1cb0a4f43
Fixed problem: FM Pump is switched off when setting the flow, more logging
2015-01-11 08:24:05 +01:00
Milan Hanajik
b79ae4b1aa
PumpTandem component added (to be completed), fixes in component config edit controls
2015-01-11 05:06:18 +01:00
Milan Hanajik
b8fb6ba12c
Fuzhou150 component updated, contains MakeExtComm()
2015-01-07 15:56:57 +01:00
Milan Hanajik
a86ad864e1
Reconfigured for Fuzhou150, missing an upgraded component
2015-01-07 10:11:29 +01:00
Milan Hanajik
580d4330e3
- PidCoef from OutputPath used in flow control, PidCoef regulValve parameter abandoned
...
- Part field (int) added to Test and TestResult, shown and processed in UI in ProcedureDlg
2015-01-04 23:21:12 +01:00
Milan Hanajik
de90a4638a
Prepared: PID coefficient of the output path is ready to be used,
...
and not the regul.valve parameter. See // TODO PID: ... in source code.
Database: 'PidCoef' float should be added to 'OutputPath' after col.'FlowMeter'
2015-01-03 21:17:11 +01:00
Milan Hanajik
0160dc965d
- RegulValve ADC Open/Close values calibration implemented
...
- 'More' button added to ComponentCfgCtrl-s
- Dataflow from ComponentParametersDlg to components: CfgChangeHandler
- Dataflow from components to ComponentParametersDlg: CmdResponseHandler
- Detection of parameter changes and appropriate MesssageBox display:
1.warning message when component configuration change requires program restart
2.confirmation message box when any configuration changes would be lost
2015-01-03 14:45:58 +01:00
Milan Hanajik
f2005bbf56
Boilerplate code reduced from factories, GetComponent() and GetControl() added to cfg-s
2015-01-02 19:14:19 +01:00
Milan Hanajik
94de991bf6
Everything works OK after serious changes:
...
- all components, componentCfg-s and parameter providers use base classes
- less boilerplate code, simpler access to test/procedure parameters from code
- CreateTestParams(test), CreateProcedureParams(procedure) methods added
- TestBenchSim class is made static, it is not inheritted by any device anymore
2015-01-02 12:51:27 +01:00
Milan Hanajik
752719bd62
Getting rid of and suppressing WARNING messages
2014-12-31 13:44:47 +01:00
Milan Hanajik
13f151b39a
Support for PT200 Israel added, fixed component for Fuzhou300 (I4 problem)
2014-12-30 13:25:01 +01:00
Milan Hanajik
42c2f88597
Minor and style changes
2014-12-30 00:17:45 +01:00