Milan Hanajik
|
a1810baffa
|
ver. 2.10.350
|
2016-09-23 15:51:12 +02:00 |
|
Milan Hanajik
|
6bb45ccc25
|
Support for GENESIS added, ver. 2.10.349
|
2016-09-22 08:50:22 +02:00 |
|
Milan Hanajik
|
5f7c0c82e7
|
Bug fix: summaryResults, allResults: ambient pressure in mbar, water pressure in kPa.
|
2016-09-14 13:05:26 +02:00 |
|
Milan Hanajik
|
1d964e5fcc
|
Czech resources added to ResultsBrowser.
|
2016-09-08 08:33:44 +02:00 |
|
Milan Hanajik
|
85ca2420bd
|
Bugs in printers caused by a change of ambient pressure representation fixed.
|
2016-09-07 18:29:25 +02:00 |
|
Milan Hanajik
|
c835fe5551
|
Keithley.TempMeter resistance 0 < R < 2000 Ohm
|
2016-08-26 11:36:42 +02:00 |
|
Milan Hanajik
|
9563dbdb6f
|
Using ITS-27 coefficients possible as well.
|
2016-08-25 17:36:27 +02:00 |
|
Milan Hanajik
|
3666752414
|
Some Keithley.TempMeter parameters (ITS-90, certificate) are accessible through Bench -> Metrology dialog.
|
2016-08-25 15:54:21 +02:00 |
|
Milan Hanajik
|
c842c50361
|
Heat meters evaluation added to FlyingStartMassCollectionSeq and FlyingStartSeq, ver. 2.10.345
|
2016-08-24 18:30:00 +02:00 |
|
Milan Hanajik
|
49c6ebf9c7
|
FileWriter or Printer crash handled, different writers/printers do not interfere with each other and results are always saved to DB.
|
2016-08-24 15:46:43 +02:00 |
|
Milan Hanajik
|
5824564e25
|
TestBenchSim modification.
|
2016-08-24 15:46:41 +02:00 |
|
Milan Hanajik
|
e484697f60
|
Heat meters reference temperature measurement during Data entry form before the test starts.
|
2016-08-24 15:46:39 +02:00 |
|
Milan Hanajik
|
9d53d7aaa8
|
Bug fix in Keitheley.TempMeter TempMeterCfgCtrl, minor change in Keithley.Multimeter_2010_RS232.
|
2016-08-24 15:46:37 +02:00 |
|
Milan Hanajik
|
1feb3215e5
|
Keithley.TempMeter uses ITS90 forms for Platinum resistance thermometer, ver. 2.10.344
|
2016-08-24 10:49:52 +02:00 |
|
Milan Hanajik
|
581819de9f
|
DataEntry.HeatMeters12 checks the entered data using 2x error limits.
|
2016-08-24 10:49:50 +02:00 |
|
Milan Hanajik
|
8cc0f3ceb4
|
Bug fix : STOP button not functional when emptying the tank, checking the weight.
|
2016-08-24 10:49:49 +02:00 |
|
Milan Hanajik
|
456687478d
|
Parse .. Double functions added to Utils.
|
2016-08-24 10:49:47 +02:00 |
|
Milan Hanajik
|
618f0b1bca
|
Modification of sequences to use ProcessData.TempRefWarm(Cold)1(2) and ReadTempOp operations, ver. 2.10.343
|
2016-08-23 15:21:33 +02:00 |
|
Milan Hanajik
|
700b9b3122
|
Keithley modifications.
|
2016-08-23 15:21:17 +02:00 |
|
Milan Hanajik
|
fc0bdda553
|
DataEntry.HeatMeters12 keeps the 'Units' selection while the software is running, restores default on start-up, ver. 2.01.342
|
2016-08-22 16:14:40 +02:00 |
|
Milan Hanajik
|
1dbe9890f3
|
Units of energy MJ and MWh added.
|
2016-08-22 16:01:34 +02:00 |
|
Milan Hanajik
|
0f7790e538
|
Prompt message box at the beginning of each heat meters test.
|
2016-08-22 16:00:48 +02:00 |
|
Milan Hanajik
|
9c0430a0d8
|
Adjustment component class name changed to TestMethods.Adjustment.Single
|
2016-08-22 15:59:37 +02:00 |
|
Milan Hanajik
|
df7631eb3a
|
Units of energy can be selected in DataEntry.HeatMeters12.TestStartEndForm.
|
2016-08-22 13:55:28 +02:00 |
|
Milan Hanajik
|
4ce613a82d
|
Bug fix: Settings of Output.FileWriters.Enhanced after upgrade wizard.
|
2016-08-22 10:55:48 +02:00 |
|
Milan Hanajik
|
d8bb450a2e
|
VolumeForEnergy calculated in [l], ver. 2.10.341
|
2016-08-22 09:58:27 +02:00 |
|
Milan Hanajik
|
774d47a86f
|
More changes and fixes for heat measurement.
|
2016-08-21 22:07:20 +02:00 |
|
Milan Hanajik
|
e3318179c1
|
More changes for heat meters testing, DataEntry form completed.
|
2016-08-19 17:19:09 +02:00 |
|
Milan Hanajik
|
74738ff78c
|
Heat meters results items.
|
2016-08-19 15:48:54 +02:00 |
|
Milan Hanajik
|
53ead401d0
|
FixedStartMassCollection : Changes for heat metetrs
|
2016-08-19 15:37:16 +02:00 |
|
Milan Hanajik
|
0426d2510a
|
Energy and RefEnergy added to ResultsDB, First/Last/Min/Max of all three ambient values added to TestRslt, ver. 2.10.340
|
2016-08-19 15:37:00 +02:00 |
|
Milan Hanajik
|
ef5bbe737c
|
Sequences.FloatStatistics -> Sequences.Statistics: use double internally, provide double Sum property.
|
2016-08-19 14:33:32 +02:00 |
|
Milan Hanajik
|
50194001d9
|
There is only one ListViewEx in Results.Forms now.
|
2016-08-19 11:50:19 +02:00 |
|
Milan Hanajik
|
f696d20060
|
It is possible to run the 2nd instance of TBF program in off-line mode, ver. 2.9.339
|
2016-08-19 10:16:47 +02:00 |
|
Milan Hanajik
|
83ddb7c8bf
|
Waiting loop for temperature stability check in heat meters tests.
|
2016-08-17 18:11:34 +02:00 |
|
Milan Hanajik
|
7d8c23d014
|
DataEntry.HeatMeters12 data entry form component added.
|
2016-08-17 18:10:48 +02:00 |
|
Milan Hanajik
|
011219d491
|
Heat meters test parameters updated.
|
2016-08-17 16:32:07 +02:00 |
|
Milan Hanajik
|
d4b20876b2
|
All FixedStart, FlyingStart and FlyingStartMassCollection methods reorganised, common sequences used, ver. 2.9.337
|
2016-08-17 15:38:09 +02:00 |
|
Milan Hanajik
|
785aae3b73
|
HeatMetersPath modifications, DB change.
|
2016-08-17 10:32:03 +02:00 |
|
Milan Hanajik
|
91cb245f84
|
ResultsBrowser : ../Cfg directory used for configuration instead of AppData/Local/..., ver. 2.9.336
|
2016-08-17 09:44:50 +02:00 |
|
Milan Hanajik
|
0859dd28d5
|
PMAxTest, LeakTest, pressure in bar internally, ver. 2.9.335
|
2016-08-16 08:32:55 +02:00 |
|
Milan Hanajik
|
df91e435bb
|
Upgrade for internal pressure interpretation change, ver. 2.9.334
|
2016-08-15 17:31:37 +02:00 |
|
Milan Hanajik
|
15f96e86ac
|
iPerlST : Workaround for Q3 with multiple parts, ver. 2.9.333
|
2016-08-15 13:44:18 +02:00 |
|
Milan Hanajik
|
a49912bdb1
|
Mouse right-click handler for ListViewEx implemented, copying the content to all cells below implemented in Paths, Transitions, Metrology corrections, process and test parameters.
|
2016-08-15 13:35:00 +02:00 |
|
Milan Hanajik
|
f7a7987831
|
Configs.NameOnly.TestMethodCfg[Ctrl] introduced and reused by Adjustment, FixedStartAdvanced, ...
... FixedStartCombinedMeters, FixedStartMassCollection, FlyingStart, FlyingStartMassCollection, ReferenceFlowMeterCalibration.
|
2016-08-15 10:14:14 +02:00 |
|
Milan Hanajik
|
8dae45e10e
|
IComponentCfg and IComponentFactory interfaces and all derived classes modified.
|
2016-08-05 14:32:36 +02:00 |
|
Milan Hanajik
|
4d616939ad
|
TestWizard.HeatMetersSelection added.
|
2016-08-04 16:47:21 +02:00 |
|
Milan Hanajik
|
e5ad1ac93b
|
HeatMeters test method, ver.2.9.333
|
2016-08-04 15:46:17 +02:00 |
|
Milan Hanajik
|
faffa8a270
|
Heat meters path modified, ver. 2.9.332
|
2016-08-04 14:01:54 +02:00 |
|
Milan Hanajik
|
4a2342c015
|
ver. 2.9.331
|
2016-08-03 10:31:31 +02:00 |
|