Commit Graph

48 Commits

Author SHA1 Message Date
Milan Hanajik
e14dc37060 TestCompletedEventArgs modification 2016-01-04 16:03:17 +01:00
Milan Hanajik
26982a5729 Many changes, new results used, all test sequences modified, simulated tests rewritten. 2016-01-04 13:53:45 +01:00
Milan Hanajik
61bfa51fa7 Uncertainty used when evaluating tests, in TestWizard, UI, etc., version 2.1.171. 2016-01-02 11:11:45 +01:00
Milan Hanajik
bb2087c002 ProcessData base class with 'public static' process data introduced. 2015-12-20 20:48:50 +01:00
Milan Hanajik
f6cec9d769 'Config', 'Results' projects added, includes iPerl opto logging bug-fixes, builds OK, cannot open DB, version 2.0.158. 2015-12-05 14:18:36 +01:00
Milan Hanajik
d7c262c87a Emptying the tank displays remaining time in min and sec. 2015-10-14 15:45:51 +02:00
Milan Hanajik
72754ebe10 Flow control during a test, version 1.5.121. 2015-09-22 18:39:00 +02:00
Milan Hanajik
d7e6a69ca9 StartMeasurementOp interface changed: OutputPath is the first argment 2015-09-22 17:03:26 +02:00
Milan Hanajik
120c1cc39d Remaining test time is shown in minutes and seconds. 2015-09-22 11:35:44 +02:00
Milan Hanajik
33963ec8cf Version 1.5.84. Reading registers, scales, temperature, pressure, ... during test done in one state in the sequence.
Many changes in TestMethods.iPerlCommunication and WaterMeters.iPerl.WaterMeter. iPerl measurement with opto-data works OK.
Logging in State changed, ...
2015-08-19 13:04:47 +02:00
Milan Hanajik
f85fbd0b55 Problems when passing flowmeter/diverter info to test start by SendCommand() fixed, version 1.5.77. 2015-08-14 18:14:08 +02:00
Milan Hanajik
95c05078de Introduction of Program.CompoundWMsCount, fix in DataEntry.Combined.CycleBeginningForm, version 1.5.68. 2015-07-09 16:24:55 +02:00
Milan Hanajik
0cea24246c Error message due to incorrect configuration is cleared after selecting another procedure/test.
Return value from WaitBeginFormClosed(..) changed from bool to enum UIFlowControl.
2015-06-25 04:48:28 +02:00
Milan Hanajik
edb6d5e8b6 'EndCondiiton' and 'Communication' added to TransitionStep (transition sequence). TODO: EndConditions functionality, version 1.5.44 2015-05-22 11:21:56 +02:00
Milan Hanajik
cd9042a648 PulsesPerLiter added to Entities.MeterTestResult and to result items. Version 1.4.36
More times added to Entities.Test (TimeBeforeFlow, TimeFlow2Mass, TimeMass2Start, TimeStop2Mass).
Activity display fixed in FlyingStartCollectionMethod.
2015-05-19 15:38:58 +02:00
Milan Hanajik
39eb2cfd57 Entry form related improvements / bugfixes (Fixed start collection method related). 2015-04-28 15:27:47 +02:00
Milan Hanajik
be78bb5ce0 Copyright message added to all cs-files 2015-04-15 20:32:56 +02:00
Milan Hanajik
c005a5cb26 Solves issue with an opened CycleBeginForm after abort and re-selection in Israel:
- CloseCycleBeginForm() -> WaitBeginFormClosed()
- CloseBeginForm() added to SequenceBase(forced dialog close)
- CloseModellFormHandler added to UiBridge.Bridge
2015-03-01 11:13:26 +01:00
Milan Hanajik
82a72670a6 Remaining time displayed for all tests 2015-02-21 20:03:33 +01:00
Milan Hanajik
1dbbe31eae Bug fix for the case of combined WM test and odd total nr. of watermeters (Munich) 2015-02-18 14:49:19 +01:00
Milan Hanajik
0c9408ff64 More configuration checks when starting a test 2015-02-02 23:18:28 +01:00
Milan Hanajik
9bd5fba6dc (1) CycleNr renamed to BatchNr (no DB change) and added to results/logs
(2) Safer result items
2015-02-02 18:10:52 +01:00
Milan Hanajik
e1756f692c Confirmed results to SummaryResults.txt logger 2015-02-02 11:38:42 +01:00
Milan Hanajik
56a9a7cf1b Test results are written into database after confirming with END 2015-02-02 00:08:47 +01:00
Milan Hanajik
5cf5fe5eba CycleNr added to LocalSettings, Entities.TestResults, Mappings, is used in sequences (DB change) 2015-01-25 08:11:40 +01:00
Milan Hanajik
ad665e5f0b Combined meters measurement corrections, Q_rise and Q_fall in results 2015-01-17 08:57:50 +01:00
Milan Hanajik
d3532a2796 PumpFM,pumpTandem test parameter Power replaced by parameter Entities.Test.PumpPower,
all changes done except of UI changes (which can be done in more different ways)
2015-01-17 04:52:42 +01:00
Milan Hanajik
bb31cdae56 Make sure CycleBeginForm is closed before the 1st test ends and s/n is in all results 2015-01-15 06:34:36 +01:00
Milan Hanajik
9c1db2778e Data of all combined meters are used in TestProgressEventArgs, in sequences and the process page 2015-01-15 03:16:14 +01:00
Milan Hanajik
1c3c90e171 CombinedMeters and CombinedWithDetection support SupressTrils bool parameter
Warnings 'Unreachable code' supressed in DataEntries
2015-01-14 05:33:51 +01:00
Milan Hanajik
34dc592e59 Timeout while setting the water flow handled correctly: message displayed, test aborted 2015-01-12 05:56:19 +01:00
Milan Hanajik
de90a4638a Prepared: PID coefficient of the output path is ready to be used,
and not the regul.valve parameter. See  // TODO PID: ...  in source code.
 Database: 'PidCoef' float should be added to 'OutputPath' after col.'FlowMeter'
2015-01-03 21:17:11 +01:00
Milan Hanajik
752719bd62 Getting rid of and suppressing WARNING messages 2014-12-31 13:44:47 +01:00
Milan Hanajik
930db8c379 - many process tab page improvements
- program start and state changes logging improved
- IDC100 measurement related changes: reference pulses in RegisterReader
- etc
2014-10-02 20:56:24 +02:00
Milan Hanajik
1c34946a6b Bugs in sequences fixed: Missing CheckUiOp 2014-09-26 17:48:55 +02:00
Milan Hanajik
a79be1e07a - bug fixed when component (class) in the DB does not exist in the code
- preparing FixedStartMassCollection sequence
2014-09-16 12:04:08 +02:00
Milan Hanajik
a919a3e9d6 - FLyngStart sequence (without balances) tested -> OK, Todo: use
corrections
- totalPulses calculated correctly in case of I11+I12 (use of two flowmeters)
2014-09-12 07:18:24 +02:00
Milan Hanajik
d0ebb62ab3 - Component update (temp.)
- Process data logging, first trial
2014-09-09 16:18:23 +02:00
Milan Hanajik
6eee83042b PmpWithFM and Transition sequences functionality implemented 2014-09-08 13:16:31 +02:00
Milan Hanajik
596667a67e Default action and stopping the FM-controlled pump
moved to SequenceBase.Transition(sequence, context).
Sequences cleaned-up.
2014-08-14 09:06:01 +02:00
Milan Hanajik
f4e7c7e88d Dnes koncim 2014-08-12 18:22:32 +02:00
Milan Hanajik
a597da1e18 Waits 15sec after setting the initial flow before detection starts 2014-08-01 10:54:38 +02:00
Milan Hanajik
fd2db3e229 As sent to Munich 2014-08-01 08:36:17 +02:00
Milan Hanajik
836daaa5a1 - German translations
- IBox, FloatBox, IntBox related changes
2014-07-31 22:17:48 +02:00
Milan Hanajik
66feec63de Koncim: IBox, etc. 2014-07-31 17:04:09 +02:00
Milan Hanajik
9a9a09f16d TolerRed parameter premenovany a pouzity ako Filter 2014-07-31 00:50:42 +02:00
Milan Hanajik
8c83965315 ProcedureName added to TestResults entity, Basic writer changes 2014-07-29 15:06:29 +02:00
Milan Hanajik
175a92f633 Initial commit almost identical to SVN-repo rev.340 2014-07-28 09:56:40 +02:00