Commit Graph

315 Commits

Author SHA1 Message Date
Milan Hanajik
5e4da449ad Endurance TestParams disabled. 2016-12-10 11:33:30 +01:00
Milan Hanajik
c30043d4fc Warsaw-END, Endurance : Component updated, CycleStepsCtrl UI fixed, ver. 2.12.408 2016-12-09 18:06:14 +01:00
Milan Hanajik
58a3340f53 Endurance : cBrd.CyclePar usage change, ver. 2.12.407 2016-12-09 16:37:25 +01:00
Milan Hanajik
6df36659ab Dummy.Balance component added 2016-12-09 12:13:59 +01:00
Milan Hanajik
6f599d55c5 Endurance : Bux fixes 2016-12-09 10:57:27 +01:00
Milan Hanajik
b91888213b ExecuteCommandOp added (Endurance). 2016-12-08 14:36:51 +01:00
Milan Hanajik
10221d636c Endurance cycle UI: duration in 10ms steps, message disabled, Uint32 used, other minor changes. 2016-12-08 10:58:09 +01:00
Milan Hanajik
5c9adba751 Endurance cycle steps dialog added. 2016-12-07 20:57:32 +01:00
Milan Hanajik
e69836b03c TBF : Type-safe structured queries used everywhere, ver. 2.12.397 2016-12-02 12:52:30 +01:00
Milan Hanajik
4917b0c0c4 TestMethods.Endurance test method added. 2016-12-02 09:10:17 +01:00
Milan Hanajik
2c0914baf8 PMaxTest, LeakTest : Minor modifications in pressure adjustment steps. 2016-11-18 11:03:44 +01:00
Milan Hanajik
98a773700e Bug fix related to PressMtrDelta, ver. 2.12.386 2016-11-17 08:48:52 +01:00
Milan Hanajik
b649c282e8 iPerlST : Modification in writing calibration factors via RFID. 2016-11-10 14:09:02 +01:00
Milan Hanajik
04cec33bf6 iPerlCommunication : "Normalize calibration factor" activity added. 2016-11-02 13:34:04 +01:00
Milan Hanajik
52d0c1907f DataEntry.HeatMeters6 and FixedStartMassCollectionSeq bug fixes, ver. 2.12.380 2016-10-28 18:45:43 +02:00
Milan Hanajik
63b5507f78 iPerlCommunication : 250ms delayafter writes, more logging, Opto-Data indication using pictureBoxes fixed. 2016-10-27 14:30:12 +02:00
Milan Hanajik
bab677c5c2 PressMtrDelta added to BenchPath, PressDeltaXyz added to TestRslt, test methods modified, ver. 2.12.373 2016-10-18 19:14:01 +02:00
Milan Hanajik
d1fb0e0f0a T warm/cold lo/hi renamed to T hi/lo min/max 2016-10-18 17:27:24 +02:00
Milan Hanajik
03c027ab33 LogProcessDataHeatMeters, ver. 2.11.371 2016-10-18 11:49:32 +02:00
Milan Hanajik
0fb3a74879 Feeding regulation valves functionality implemented, ver. 2.11.367 2016-10-13 16:08:29 +02:00
Milan Hanajik
45e0f50562 Elde.RegulValve supports 'ReTryCommands' parameter (default = false), ver. 2.11.365 2016-10-13 16:08:15 +02:00
Milan Hanajik
dddfc4bed5 Bug-fixes in FlyingStart and FlyingStartMassCollection heat meters, T ref warm and T ref cold statistics, ver. 2.10.362 2016-10-12 01:23:38 +02:00
Milan Hanajik
b3a2c3a0fc FlyingStart, FlyingStartMassCollection and CombinedWithDetection methods support Simulation mode, ver. 2.10.360 2016-10-11 12:53:17 +02:00
Milan Hanajik
c84fd8089a FlyingStart and FlyingStartMassCollection methods: 'Begin cycle' dialog closed before 'Heat meters prompt message' is displayed. 2016-10-11 09:10:33 +02:00
Milan Hanajik
5f21b5ab26 ErrorLimitHi, ErrorLimitLo, EvaluateVolume test parameters added to all heat meters methods. 2016-10-10 14:35:59 +02:00
Milan Hanajik
f8331c1c1c Heat meters : Prompt message does not stop the sequence, disappears when conditions met, ver. 2.10.359 2016-10-10 14:23:20 +02:00
Milan Hanajik
3c15dbab9e Bug fixes in heat meter testing using pulses, Flying start and Flying start mass collection methods, ver. 2.10.358 2016-10-10 11:35:45 +02:00
Milan Hanajik
438028506e Flows are internally stored and processed in double variables (except of Qfrom, Qto, flowmeter nominal flow) 2016-10-07 16:22:36 +02:00
Milan Hanajik
010afcd1e4 Temperatures are internally stored and processed in double variables (except of ambient temp.). 2016-10-07 15:41:27 +02:00
Milan Hanajik
7df9333fba Statistics return doubles instead of float, casting is done just when writing to entities. 2016-10-07 14:46:14 +02:00
Milan Hanajik
4160420844 Masses are stored in double variables everywhere. 2016-10-07 14:06:54 +02:00
Milan Hanajik
c30f905893 SLM50 : Bugfix in energy calculation in FlyingStart and FlyingStartMassCollection methods, ver. 2.10.356 2016-10-07 10:09:38 +02:00
Milan Hanajik
c497c02ef9 Heat meters support for measurement with pulses, change in ResultsDB.MeterTestRslt, ver. 2.10.352 2016-10-06 10:11:13 +02:00
Milan Hanajik
2286877fad Test method names cleaned up. 2016-09-26 11:08:16 +02:00
Milan Hanajik
c842c50361 Heat meters evaluation added to FlyingStartMassCollectionSeq and FlyingStartSeq, ver. 2.10.345 2016-08-24 18:30:00 +02:00
Milan Hanajik
e484697f60 Heat meters reference temperature measurement during Data entry form before the test starts. 2016-08-24 15:46:39 +02:00
Milan Hanajik
618f0b1bca Modification of sequences to use ProcessData.TempRefWarm(Cold)1(2) and ReadTempOp operations, ver. 2.10.343 2016-08-23 15:21:33 +02:00
Milan Hanajik
0f7790e538 Prompt message box at the beginning of each heat meters test. 2016-08-22 16:00:48 +02:00
Milan Hanajik
9c0430a0d8 Adjustment component class name changed to TestMethods.Adjustment.Single 2016-08-22 15:59:37 +02:00
Milan Hanajik
df7631eb3a Units of energy can be selected in DataEntry.HeatMeters12.TestStartEndForm. 2016-08-22 13:55:28 +02:00
Milan Hanajik
d8bb450a2e VolumeForEnergy calculated in [l], ver. 2.10.341 2016-08-22 09:58:27 +02:00
Milan Hanajik
774d47a86f More changes and fixes for heat measurement. 2016-08-21 22:07:20 +02:00
Milan Hanajik
e3318179c1 More changes for heat meters testing, DataEntry form completed. 2016-08-19 17:19:09 +02:00
Milan Hanajik
53ead401d0 FixedStartMassCollection : Changes for heat metetrs 2016-08-19 15:37:16 +02:00
Milan Hanajik
0426d2510a Energy and RefEnergy added to ResultsDB, First/Last/Min/Max of all three ambient values added to TestRslt, ver. 2.10.340 2016-08-19 15:37:00 +02:00
Milan Hanajik
83ddb7c8bf Waiting loop for temperature stability check in heat meters tests. 2016-08-17 18:11:34 +02:00
Milan Hanajik
011219d491 Heat meters test parameters updated. 2016-08-17 16:32:07 +02:00
Milan Hanajik
d4b20876b2 All FixedStart, FlyingStart and FlyingStartMassCollection methods reorganised, common sequences used, ver. 2.9.337 2016-08-17 15:38:09 +02:00
Milan Hanajik
0859dd28d5 PMAxTest, LeakTest, pressure in bar internally, ver. 2.9.335 2016-08-16 08:32:55 +02:00
Milan Hanajik
f7a7987831 Configs.NameOnly.TestMethodCfg[Ctrl] introduced and reused by Adjustment, FixedStartAdvanced, ...
... FixedStartCombinedMeters, FixedStartMassCollection, FlyingStart, FlyingStartMassCollection, ReferenceFlowMeterCalibration.
2016-08-15 10:14:14 +02:00
Milan Hanajik
8dae45e10e IComponentCfg and IComponentFactory interfaces and all derived classes modified. 2016-08-05 14:32:36 +02:00
Milan Hanajik
e5ad1ac93b HeatMeters test method, ver.2.9.333 2016-08-04 15:46:17 +02:00
Milan Hanajik
111e3d8647 Minimum and maximum (reference) flow during a test calculated and saved to Results.Entities.TestRslt. 2016-08-02 14:48:18 +02:00
Milan Hanajik
c88ac1fcab Pressure up and Pressure down stored in mbar, not in kPa. Display in process data screens fixed. 2016-08-02 10:47:51 +02:00
Milan Hanajik
fa2896d755 Enthalpy calculation (1st ver.), heat meters path modifications (incl. UI) 2016-07-07 16:02:57 +02:00
Milan Hanajik
0ac1fe2b4e HeatMetersPath, UI, etc., HEAT_METERS_SUPPORT symbol introduced
ProcedureDlg modifications: (1) localization by TBF.Resources.Strings, (2) Heat meters support
FlyingStartMassCollection and CombinedMeters methods with similar sequences
2016-07-06 15:59:28 +02:00
Milan Hanajik
ac1bdbe476 Bug fix: Updating water meter results in case of a test with parts, copes also with single meters/multiple lines. 2016-06-30 14:03:51 +02:00
Milan Hanajik
799fda63e9 Bug fix : Updating water meters results in case of test with 'parts'. 2016-06-30 12:55:35 +02:00
Milan Hanajik
9d56836c80 Procedure number displayed in ProceduresDlg (the list of procedures).
Deleting a procedure modified, confirmed by a question, change applied to the DB immediately,
Localization to DE, CS, ...  pressure test and leak test, etc.
2016-06-28 15:09:32 +02:00
Milan Hanajik
8a3a0ca6ef (1) iPerlCommunicationForm displays green/red rectangle as opto-data indication, (2) ProcedureDlg displays date and time of changes, ver. 2.8.314 2016-06-27 15:45:35 +02:00
Milan Hanajik
1337fff2dc Fixed: (1) STOP button does not function in FlyingStart and FlyingStartMassCollection methods, (2) Results.Entities.WaterMeterData.Equals(.) 2016-06-15 17:04:25 +02:00
Milan Hanajik
2935bc2c77 Many localisation improvements, ver.2.7.297 2016-05-29 23:17:48 +02:00
Milan Hanajik
7c7f330a0b Progress bar fixed for Pressure and Leak test. 2016-05-19 12:43:45 +02:00
Milan Hanajik
291bb72cf5 iPerlCommunicationForm resized depending on the number of iPerl-s, gray color, ver.2.5.273 2016-04-23 14:32:15 +02:00
Milan Hanajik
a41d0517d2 Bug fixes in resources, ano/ne usage, etc., ver.2.5.271 2016-04-20 17:45:18 +02:00
Milan Hanajik
e09aad2a6d iPerlSpecial bug fix 2016-04-20 15:03:18 +02:00
Milan Hanajik
1d924d7d40 iPerlSpecial modifications: RFID ports defined by watermeters, no Quido used, ver.2.5.268. 2016-04-19 10:10:51 +02:00
Milan Hanajik
b1e0e74d8a iPerlSpecial modifications 2016-04-18 13:38:13 +02:00
Milan Hanajik
9a725de4a9 Stable mass measurement rewritten, it can use immediate measurement, DB change, ver.2.5.265. 2016-04-14 17:03:33 +02:00
Milan Hanajik
e037720115 iPerlST: Logging of a STOP command via UI. 2016-04-14 09:16:20 +02:00
Milan Hanajik
f901367817 iPerl ST component, symbol IPERLST_SPECIAL, etc. added to the project, ver. 2.4.260. 2016-04-07 15:37:49 +02:00
Milan Hanajik
b006e36d52 Stop Backflow Valve added, used in FlyingStartMassCollection method, ver.2.4.248. 2016-03-18 10:36:33 +08:00
Milan Hanajik
2392bfa2a7 FlyingStartCollectionMethod timing modified, start valve used, ver.2.3.245. 2016-03-17 13:02:25 +08:00
Milan Hanajik
b86ca9fac8 Active FM pump is switched off in 'default action' after test (not when transition sequences are used), ver.2.3.242. 2016-03-15 19:29:47 +08:00
Milan Hanajik
25eff13c41 Bug fix in iPerl communication when L1 only or L2 only used. 2016-03-01 18:57:36 +01:00
Milan Hanajik
d2493b0331 Bug fix: padlo v Active mode na konci cyklu, ver.2.3.230. 2016-03-01 16:22:49 +01:00
Milan Hanajik
4ab889b43e Publish, Evaluate test parameters of the Flying start mass collection method excluded. 2016-02-19 10:43:42 +01:00
Milan Hanajik
4d39805ef4 Bug fixes: (1) in MainSeq when starting iPearlCommForm, (2) in SetActiveMode (config struct was null), version 2.2.217. 2016-02-16 17:25:01 +01:00
Milan Hanajik
4b1a684d69 2Hz correction related changes: iPerlCommunication: 'Reset 2Hz correction', 'Write 2Hz correction' + OraDB changes. 2016-02-16 14:44:10 +01:00
Milan Hanajik
a22b4de1b6 FlyingStart measurement during test simplified similarly to FlyingStartMassCollection, version 2.1.215. 2016-02-16 12:28:36 +01:00
Milan Hanajik
462ed568de Bug fixes: (1) simulation, (2) when BenchInfo==null, (3) ProcessData.RefPulses updated, (4) ProcessTabPages, etc. 2016-02-15 22:48:44 +01:00
Milan Hanajik
92bcd46549 Working on 2Hz correction 2016-02-15 15:16:44 +01:00
Milan Hanajik
e22d58101c Correct start-up message when there is no CB component, version 2.1.214 2016-02-14 23:17:02 +01:00
Milan Hanajik
edc4d59f90 Process data screen update when test completed, version 2.1.213. 2016-02-13 19:28:33 +01:00
Milan Hanajik
6a159f773e WMPulses[], WMRefPulses[], WMTimes[] removed from SequenceBase, operations, etc., clean-up. 2016-02-13 17:39:38 +01:00
Milan Hanajik
e94e16c9e6 Use of ProcessData.RegisterReaders in iPerlCommunicationForm. 2016-02-13 16:40:26 +01:00
Milan Hanajik
3946d26cb4 IRegisterReader extended, ReadReferenceForRegisterOp removed, ReadRegisteOp integrated into RegisterReader class, ProcessTabPages updated. 2016-02-13 15:02:10 +01:00
Milan Hanajik
7534fc7c24 Removed WMPulses and WMRefPulses logs. 2016-02-13 08:11:50 +01:00
Milan Hanajik
2c1e4e7d26 Process data display : many changes, TODO: Meter data and the end of test. 2016-02-10 19:24:10 +01:00
Milan Hanajik
6e2bf48b43 (1) State of the RegulValve checked after ValveMove (#, position, ...), (2) RFID results are saved only when SimultWithPrevious == true. 2016-02-08 17:49:49 +01:00
Milan Hanajik
3407b51c27 All changes done for Badger-velka-trat merged into this branch, version 2.1.210. 2016-02-07 22:55:48 +01:00
Milan Hanajik
a4331c8267 Fixes occasional problem/crash for an iPearl test with Parts when iPearls are activated after 'End', version 2.1.190. 2016-01-19 21:12:35 +01:00
Milan Hanajik
66a31fc1e9 Serious iPearl bug fix, flow setting timeout time increased, version 2.1.183. 2016-01-10 12:39:20 +01:00
Milan Hanajik
d84c3ca4d8 Cosmetical changes (progress for modeless form sometimes not completed) 2016-01-10 01:44:28 +01:00
Milan Hanajik
98c8b0e7a8 iPearl debugging, progress management, OracleDB simulation, etc, version 2.1.182 2016-01-09 20:06:59 +01:00
Milan Hanajik
68c4bf5956 Separate string SerialNrAux and int SerialNrEx in Results. Other fixes. Version 2.1.180 2016-01-08 17:10:05 +01:00
Milan Hanajik
e14dc37060 TestCompletedEventArgs modification 2016-01-04 16:03:17 +01:00
Milan Hanajik
1e058726d4 Adjustment modified to use the new Results. 2016-01-04 15:24:16 +01:00
Milan Hanajik
26982a5729 Many changes, new results used, all test sequences modified, simulated tests rewritten. 2016-01-04 13:53:45 +01:00
Milan Hanajik
61bfa51fa7 Uncertainty used when evaluating tests, in TestWizard, UI, etc., version 2.1.171. 2016-01-02 11:11:45 +01:00