Milan Hanajik
ed83ae57c5
Progress bars are not displayed as 'completed' when a test was aborted.
2017-05-05 12:46:37 +02:00
Milan Hanajik
17c685148e
(1) Flow selection in New Test Wizard extended, (2) MainSeq and BencControlPael modified, etc.
2017-05-03 22:24:25 +02:00
Milan Hanajik
59392d8bdc
MakeSimulated fixed when there are multiple test repetitions, ver. 2.12.555
2017-05-01 10:28:43 +02:00
Milan Hanajik
eafcf016f3
Setting regulation valves before flow setting disabled, caused porbles all the time, ver. 2.12 549
2017-04-24 11:58:57 +02:00
Milan Hanajik
05982cc2ff
Endurance test method sequence modified.
2017-04-24 09:44:11 +02:00
Milan Hanajik
d372a38e7d
Camera time read with each sample, calculation : VolumeStart, VolumeEnd, TimestampStart, TimestampEnd used, ver. 2.12.530
2017-04-07 11:29:35 +02:00
Milan Hanajik
44735260ce
CLP1611 Measurement done only on successfully detected ROI-s, ver. 2.12.530
2017-04-06 23:47:24 +02:00
Milan Hanajik
464dfc6dd1
FlyingStartMassCollection : 'Next' button can be used to stop the test.
2017-04-05 22:01:21 +02:00
Milan Hanajik
049bbc8655
DEWA Q2 correction modified, Results.Entities.WaterMeter columns added (iPerl only).
2017-03-31 14:17:18 +02:00
Milan Hanajik
5f2da63339
Drain valve removed from Output path, outPath.Scale.DrainValve used instead of outPath.DrainValve, wait for Event. BalanceDone before 2nd mass measurement in FlyingStartMassCollection, ver. 2.12.519
2017-03-29 09:22:39 +02:00
Milan Hanajik
d420128b4b
Draining modified, in BERLIN done always before flow setting, ver. 2.12.518
2017-03-28 23:54:52 +02:00
Milan Hanajik
3c4fe34c1d
Test_volume_exceeds_the_scale_capacity situation handled correctly, no Error state.
2017-03-27 14:08:53 +02:00
Milan Hanajik
8d4af6f347
Bug in iPerl IRegisterReader usage by FlyingStartMassCollectionSeq fixed, ver. 2.12.501
2017-03-20 17:44:28 +01:00
Milan Hanajik
87bc0131cf
Tests when test volume exceeds the tank capacity cannot be executed, an error message appears.
2017-03-10 13:10:57 +01:00
Milan Hanajik
4515f0fc13
FlyingStartMassCollectionSeq modified : Valves/pumps are closed immediately after the test only when there are no subsequent test repeats.
2017-02-21 10:45:26 +01:00
Milan Hanajik
970fc886c6
FlyingStartMassCollectionSeq : If transitionAfter is not used, the valves/pumps are closed immediately after the test before the 2nd mass measurement, ver. 2.12.472
2017-02-17 10:51:30 +01:00
Milan Hanajik
8d4910fcb0
Symbols: introduced IPERL, ORACLE_DB, HEAT_METERS, TURA_IPERL, TURA_SPECIAL
...
abandoned IPERLST, IPERLSTSPECIAL, HEAT_METERS_SUPPORT
2017-02-14 13:42:22 +01:00
Milan Hanajik
38c199f6f9
Interfaces between Camera and Roi and sequences finalized, TODO: network communication, ver. 2.12.446
...
Sequences more robust for debugging, T and Pr-meters checked for null
2017-01-25 17:28:57 +01:00
Milan Hanajik
044e53f2b2
Changes under construction : ROI registration to Cameras, ver. 2.12.441
2017-01-24 12:34:52 +01:00
Milan Hanajik
2150ced11f
Propagation of ROI parameters between ROI-s and Cameras implemented, ver. 2.12.438
2017-01-22 20:40:12 +01:00
Milan Hanajik
6d45b2c878
RoiDetectionSeq modified, ready to be tested.
2017-01-16 15:51:34 +01:00
Milan Hanajik
c73cf7002f
Camera.Roi.MeasurementOp added, UDP listener added, PulsesPerLtr (and ProcedureParams) added, etc.
2017-01-16 13:49:29 +01:00
Milan Hanajik
89901c75f7
Revert "Elde.FlowMeterTwins bug-fix in calculation of ref. pulses and flow."
...
This reverts commit be52e2df96 .
2016-12-16 13:07:54 +01:00
Milan Hanajik
be52e2df96
Elde.FlowMeterTwins bug-fix in calculation of ref. pulses and flow.
2016-12-12 16:43:04 +01:00
Milan Hanajik
216e08d57c
Execute(...) arguments changed everywhere, repetitionNr usage depends on outerLoopMode, outerLoopCounter, ver. 2.12.412
2016-12-10 13:03:35 +01:00
Milan Hanajik
98a773700e
Bug fix related to PressMtrDelta, ver. 2.12.386
2016-11-17 08:48:52 +01:00
Milan Hanajik
bab677c5c2
PressMtrDelta added to BenchPath, PressDeltaXyz added to TestRslt, test methods modified, ver. 2.12.373
2016-10-18 19:14:01 +02:00
Milan Hanajik
03c027ab33
LogProcessDataHeatMeters, ver. 2.11.371
2016-10-18 11:49:32 +02:00
Milan Hanajik
0fb3a74879
Feeding regulation valves functionality implemented, ver. 2.11.367
2016-10-13 16:08:29 +02:00
Milan Hanajik
45e0f50562
Elde.RegulValve supports 'ReTryCommands' parameter (default = false), ver. 2.11.365
2016-10-13 16:08:15 +02:00
Milan Hanajik
dddfc4bed5
Bug-fixes in FlyingStart and FlyingStartMassCollection heat meters, T ref warm and T ref cold statistics, ver. 2.10.362
2016-10-12 01:23:38 +02:00
Milan Hanajik
b3a2c3a0fc
FlyingStart, FlyingStartMassCollection and CombinedWithDetection methods support Simulation mode, ver. 2.10.360
2016-10-11 12:53:17 +02:00
Milan Hanajik
c84fd8089a
FlyingStart and FlyingStartMassCollection methods: 'Begin cycle' dialog closed before 'Heat meters prompt message' is displayed.
2016-10-11 09:10:33 +02:00
Milan Hanajik
5f21b5ab26
ErrorLimitHi, ErrorLimitLo, EvaluateVolume test parameters added to all heat meters methods.
2016-10-10 14:35:59 +02:00
Milan Hanajik
f8331c1c1c
Heat meters : Prompt message does not stop the sequence, disappears when conditions met, ver. 2.10.359
2016-10-10 14:23:20 +02:00
Milan Hanajik
3c15dbab9e
Bug fixes in heat meter testing using pulses, Flying start and Flying start mass collection methods, ver. 2.10.358
2016-10-10 11:35:45 +02:00
Milan Hanajik
438028506e
Flows are internally stored and processed in double variables (except of Qfrom, Qto, flowmeter nominal flow)
2016-10-07 16:22:36 +02:00
Milan Hanajik
010afcd1e4
Temperatures are internally stored and processed in double variables (except of ambient temp.).
2016-10-07 15:41:27 +02:00
Milan Hanajik
7df9333fba
Statistics return doubles instead of float, casting is done just when writing to entities.
2016-10-07 14:46:14 +02:00
Milan Hanajik
4160420844
Masses are stored in double variables everywhere.
2016-10-07 14:06:54 +02:00
Milan Hanajik
c30f905893
SLM50 : Bugfix in energy calculation in FlyingStart and FlyingStartMassCollection methods, ver. 2.10.356
2016-10-07 10:09:38 +02:00
Milan Hanajik
c497c02ef9
Heat meters support for measurement with pulses, change in ResultsDB.MeterTestRslt, ver. 2.10.352
2016-10-06 10:11:13 +02:00
Milan Hanajik
c842c50361
Heat meters evaluation added to FlyingStartMassCollectionSeq and FlyingStartSeq, ver. 2.10.345
2016-08-24 18:30:00 +02:00
Milan Hanajik
53ead401d0
FixedStartMassCollection : Changes for heat metetrs
2016-08-19 15:37:16 +02:00
Milan Hanajik
0426d2510a
Energy and RefEnergy added to ResultsDB, First/Last/Min/Max of all three ambient values added to TestRslt, ver. 2.10.340
2016-08-19 15:37:00 +02:00
Milan Hanajik
83ddb7c8bf
Waiting loop for temperature stability check in heat meters tests.
2016-08-17 18:11:34 +02:00
Milan Hanajik
d4b20876b2
All FixedStart, FlyingStart and FlyingStartMassCollection methods reorganised, common sequences used, ver. 2.9.337
2016-08-17 15:38:09 +02:00
Milan Hanajik
111e3d8647
Minimum and maximum (reference) flow during a test calculated and saved to Results.Entities.TestRslt.
2016-08-02 14:48:18 +02:00
Milan Hanajik
fa2896d755
Enthalpy calculation (1st ver.), heat meters path modifications (incl. UI)
2016-07-07 16:02:57 +02:00
Milan Hanajik
0ac1fe2b4e
HeatMetersPath, UI, etc., HEAT_METERS_SUPPORT symbol introduced
...
ProcedureDlg modifications: (1) localization by TBF.Resources.Strings, (2) Heat meters support
FlyingStartMassCollection and CombinedMeters methods with similar sequences
2016-07-06 15:59:28 +02:00