Milan Hanajik
|
38d6016aec
|
DataEntry.HeatMeters6 component added.
|
2016-10-11 13:05:40 +02:00 |
|
Milan Hanajik
|
b3a2c3a0fc
|
FlyingStart, FlyingStartMassCollection and CombinedWithDetection methods support Simulation mode, ver. 2.10.360
|
2016-10-11 12:53:17 +02:00 |
|
Milan Hanajik
|
c84fd8089a
|
FlyingStart and FlyingStartMassCollection methods: 'Begin cycle' dialog closed before 'Heat meters prompt message' is displayed.
|
2016-10-11 09:10:33 +02:00 |
|
Milan Hanajik
|
2e4c59d3b5
|
Keithley Multimeter supports simulation mode.
|
2016-10-11 09:09:04 +02:00 |
|
Milan Hanajik
|
5f21b5ab26
|
ErrorLimitHi, ErrorLimitLo, EvaluateVolume test parameters added to all heat meters methods.
|
2016-10-10 14:35:59 +02:00 |
|
Milan Hanajik
|
f8331c1c1c
|
Heat meters : Prompt message does not stop the sequence, disappears when conditions met, ver. 2.10.359
|
2016-10-10 14:23:20 +02:00 |
|
Milan Hanajik
|
3c15dbab9e
|
Bug fixes in heat meter testing using pulses, Flying start and Flying start mass collection methods, ver. 2.10.358
|
2016-10-10 11:35:45 +02:00 |
|
Milan Hanajik
|
d5eb20854f
|
Displaying heat meter test results on screen fixed, ver. 2.10.357
|
2016-10-07 18:19:17 +02:00 |
|
Milan Hanajik
|
438028506e
|
Flows are internally stored and processed in double variables (except of Qfrom, Qto, flowmeter nominal flow)
|
2016-10-07 16:22:36 +02:00 |
|
Milan Hanajik
|
010afcd1e4
|
Temperatures are internally stored and processed in double variables (except of ambient temp.).
|
2016-10-07 15:41:27 +02:00 |
|
Milan Hanajik
|
7df9333fba
|
Statistics return doubles instead of float, casting is done just when writing to entities.
|
2016-10-07 14:46:14 +02:00 |
|
Milan Hanajik
|
4160420844
|
Masses are stored in double variables everywhere.
|
2016-10-07 14:06:54 +02:00 |
|
Milan Hanajik
|
9f2e8407a0
|
Modbus.PressureMeter.Meter component added, ver. 2.10.357
|
2016-10-07 11:59:13 +02:00 |
|
Milan Hanajik
|
45c64ae44b
|
Modbus does not use an extra worker thread.
|
2016-10-07 11:55:44 +02:00 |
|
Milan Hanajik
|
e8748bab70
|
(1) QuidoRS dead code clean-up, (2) Elde.PressureMeter units conversion clean-up.
|
2016-10-07 11:55:03 +02:00 |
|
Milan Hanajik
|
c30f905893
|
SLM50 : Bugfix in energy calculation in FlyingStart and FlyingStartMassCollection methods, ver. 2.10.356
|
2016-10-07 10:09:38 +02:00 |
|
Milan Hanajik
|
8932c232e2
|
Malta : Another minor change, ver. 2.10.355
|
2016-10-06 14:26:08 +02:00 |
|
Milan Hanajik
|
295e96098c
|
Malta : Minor changes, extended range of Id-s for flow meters and pressure meters, ver.2.10.354
|
2016-10-06 14:02:16 +02:00 |
|
Milan Hanajik
|
dff3a1aff7
|
Changes in 'master' for Malta-WSD25, ver. 2.10.353
|
2016-10-06 11:54:38 +02:00 |
|
Milan Hanajik
|
c497c02ef9
|
Heat meters support for measurement with pulses, change in ResultsDB.MeterTestRslt, ver. 2.10.352
|
2016-10-06 10:11:13 +02:00 |
|
Milan Hanajik
|
2286877fad
|
Test method names cleaned up.
|
2016-09-26 11:08:16 +02:00 |
|
Milan Hanajik
|
6bb45ccc25
|
Support for GENESIS added, ver. 2.10.349
|
2016-09-22 08:50:22 +02:00 |
|
Milan Hanajik
|
5f7c0c82e7
|
Bug fix: summaryResults, allResults: ambient pressure in mbar, water pressure in kPa.
|
2016-09-14 13:05:26 +02:00 |
|
Milan Hanajik
|
85ca2420bd
|
Bugs in printers caused by a change of ambient pressure representation fixed.
|
2016-09-07 18:29:25 +02:00 |
|
Milan Hanajik
|
c835fe5551
|
Keithley.TempMeter resistance 0 < R < 2000 Ohm
|
2016-08-26 11:36:42 +02:00 |
|
Milan Hanajik
|
9563dbdb6f
|
Using ITS-27 coefficients possible as well.
|
2016-08-25 17:36:27 +02:00 |
|
Milan Hanajik
|
3666752414
|
Some Keithley.TempMeter parameters (ITS-90, certificate) are accessible through Bench -> Metrology dialog.
|
2016-08-25 15:54:21 +02:00 |
|
Milan Hanajik
|
c842c50361
|
Heat meters evaluation added to FlyingStartMassCollectionSeq and FlyingStartSeq, ver. 2.10.345
|
2016-08-24 18:30:00 +02:00 |
|
Milan Hanajik
|
49c6ebf9c7
|
FileWriter or Printer crash handled, different writers/printers do not interfere with each other and results are always saved to DB.
|
2016-08-24 15:46:43 +02:00 |
|
Milan Hanajik
|
5824564e25
|
TestBenchSim modification.
|
2016-08-24 15:46:41 +02:00 |
|
Milan Hanajik
|
e484697f60
|
Heat meters reference temperature measurement during Data entry form before the test starts.
|
2016-08-24 15:46:39 +02:00 |
|
Milan Hanajik
|
9d53d7aaa8
|
Bug fix in Keitheley.TempMeter TempMeterCfgCtrl, minor change in Keithley.Multimeter_2010_RS232.
|
2016-08-24 15:46:37 +02:00 |
|
Milan Hanajik
|
1feb3215e5
|
Keithley.TempMeter uses ITS90 forms for Platinum resistance thermometer, ver. 2.10.344
|
2016-08-24 10:49:52 +02:00 |
|
Milan Hanajik
|
581819de9f
|
DataEntry.HeatMeters12 checks the entered data using 2x error limits.
|
2016-08-24 10:49:50 +02:00 |
|
Milan Hanajik
|
8cc0f3ceb4
|
Bug fix : STOP button not functional when emptying the tank, checking the weight.
|
2016-08-24 10:49:49 +02:00 |
|
Milan Hanajik
|
618f0b1bca
|
Modification of sequences to use ProcessData.TempRefWarm(Cold)1(2) and ReadTempOp operations, ver. 2.10.343
|
2016-08-23 15:21:33 +02:00 |
|
Milan Hanajik
|
700b9b3122
|
Keithley modifications.
|
2016-08-23 15:21:17 +02:00 |
|
Milan Hanajik
|
fc0bdda553
|
DataEntry.HeatMeters12 keeps the 'Units' selection while the software is running, restores default on start-up, ver. 2.01.342
|
2016-08-22 16:14:40 +02:00 |
|
Milan Hanajik
|
0f7790e538
|
Prompt message box at the beginning of each heat meters test.
|
2016-08-22 16:00:48 +02:00 |
|
Milan Hanajik
|
9c0430a0d8
|
Adjustment component class name changed to TestMethods.Adjustment.Single
|
2016-08-22 15:59:37 +02:00 |
|
Milan Hanajik
|
df7631eb3a
|
Units of energy can be selected in DataEntry.HeatMeters12.TestStartEndForm.
|
2016-08-22 13:55:28 +02:00 |
|
Milan Hanajik
|
4ce613a82d
|
Bug fix: Settings of Output.FileWriters.Enhanced after upgrade wizard.
|
2016-08-22 10:55:48 +02:00 |
|
Milan Hanajik
|
d8bb450a2e
|
VolumeForEnergy calculated in [l], ver. 2.10.341
|
2016-08-22 09:58:27 +02:00 |
|
Milan Hanajik
|
774d47a86f
|
More changes and fixes for heat measurement.
|
2016-08-21 22:07:20 +02:00 |
|
Milan Hanajik
|
e3318179c1
|
More changes for heat meters testing, DataEntry form completed.
|
2016-08-19 17:19:09 +02:00 |
|
Milan Hanajik
|
53ead401d0
|
FixedStartMassCollection : Changes for heat metetrs
|
2016-08-19 15:37:16 +02:00 |
|
Milan Hanajik
|
0426d2510a
|
Energy and RefEnergy added to ResultsDB, First/Last/Min/Max of all three ambient values added to TestRslt, ver. 2.10.340
|
2016-08-19 15:37:00 +02:00 |
|
Milan Hanajik
|
ef5bbe737c
|
Sequences.FloatStatistics -> Sequences.Statistics: use double internally, provide double Sum property.
|
2016-08-19 14:33:32 +02:00 |
|
Milan Hanajik
|
83ddb7c8bf
|
Waiting loop for temperature stability check in heat meters tests.
|
2016-08-17 18:11:34 +02:00 |
|
Milan Hanajik
|
7d8c23d014
|
DataEntry.HeatMeters12 data entry form component added.
|
2016-08-17 18:10:48 +02:00 |
|