Commit Graph

75 Commits

Author SHA1 Message Date
Milan Hanajik
2e593d11eb (1) Results are redrawn when iPerlCommForm is closed, (2) 'Stop draining' is password protected, (3) PW-s updated, ver. 2.18.901 2018-05-21 16:45:54 +02:00
Milan Hanajik
e150624f4d Bug fixes in DataEntry.Standard6.TestStartEndForm, more logging, ver. 2.18.899 2018-05-18 16:30:59 +02:00
Milan Hanajik
d8e0772a0f ZAMBIA define and packages/ControlBoard/Zambia/... component added, ver. 2.18.894 2018-05-17 09:00:08 +02:00
Milan Hanajik
86601e1ba1 BugFix in ...Elde.StartMeasurementOp for the case of RV=...Elde.RegulValveCoax.RegulValve 2018-05-14 16:03:02 +02:00
Milan Hanajik
67a762e51c MettlerToledo.Standard : Timeout in ReadMassOp and ReadStableMassOp, ver. 2.18.892 2018-05-14 10:41:03 +02:00
Milan Hanajik
d6881bfdf3 (1) ParamsProvider-s added to C..Test/C..Procedure entities, (2) ComponentCfgBase fn-s returning IParamsProvider rewritten, (3) refactoring, ver. 2.18.891 2018-05-11 16:51:07 +02:00
Milan Hanajik
878c89591e Bug fixes: (1) in MainWnd when proc. added to empty DB, (2) in TestParamsCtrl when a test added and moved up, (3) other minor, (4) ItemNr of editted procedure displayed almost always, ver. 2.18.890 2018-05-02 15:52:53 +02:00
Milan Hanajik
f332fd7141 FlyingStartMassCollection and FlyingStart : Case when there is one or no pulse from the water meter handled correctly. 2018-04-27 13:52:06 +02:00
Milan Hanajik
bb3be1c649 Results.Entities.TestRslt.ConstMasterRaw added, set to outPath.FlowMeter.LtrPerPulse in sequences 2018-04-27 11:00:05 +02:00
Milan Hanajik
e88175b349 (1) Output.DB.SaveFlowmeterCorrections: date, validity, certificate, (2) Flow_ctv, Flow_ctv_min, ... 2018-04-25 12:49:07 +02:00
Milan Hanajik
c0f4c5acef (1) Multiple start valves, test methods modified, (2) Component for JuznaAfrika50 (25.04.2018), ver. 2.18.887 2018-04-25 12:47:33 +02:00
Milan Hanajik
1f9df9bb67 (1) Units : lpp,dm3pp,lpdeg,dm3pdeg added, (2) Bug fix in WMRsltItemSpec(ItemID.P_delta_mean_from_up_down_per_mtr, ... , ver. 2.18.884 2018-04-19 14:42:42 +02:00
Milan Hanajik
60f7fbe4c3 More logging, Italian, quantities with units in many languages, etc., ver. 2.18.880 2018-04-17 23:28:00 +02:00
Milan Hanajik
04878cea50 Config.Entities.Medium : ToDescription() used in UI, Strings.cold/hot removed, gorjaca->ciepla, ver.2.19.879 2018-04-17 09:04:32 +02:00
Milan Hanajik
5769b6ad48 Bug fixes: (1) OnePerMeter : 'WaterMeters[0]' used instead of 'wm', (2) Printers.Table : last vertical line, ver. 2.18.877 2018-04-15 12:19:06 +02:00
Milan Hanajik
b17d710044 Results.Entities.WaterMetrData.Medium added, woda zimna/goraca, ver. 2.18.876 2018-04-15 11:34:07 +02:00
Milan Hanajik
441601bd42 iPerl : Default calibration factors modified, ver. 2.18.875 2018-04-12 15:46:12 +02:00
Milan Hanajik
98c1194e5b Bug fix in Sequences.MainSeq.RestoreBatchResults. 2018-04-12 12:42:11 +02:00
Milan Hanajik
0993716c8e (1) TBF.BenchControl.Formulas --> Config.Formulas, (2) MeterTestRslt.RegReaderType, (3) Rslt.items added, (4) Quantity.Pulses, ver. 2.18.870 2018-04-11 11:11:45 +02:00
Milan Hanajik
a4a589a40c Cleanup : Results/ItemSpec, ResultsPrinters/Cevak/... removed, etc., ver. 2.18.869 2018-04-09 13:44:28 +02:00
Milan Hanajik
0436906a59 Elde.StopPreviousOp modified : STOP command resent if necessary, ver. 2.18.868 2018-04-09 10:59:40 +02:00
Milan Hanajik
80db263929 (1) Printers.OnePerMeter with 3 columns above and below the body, (2) static Table Create_xy(...) introduced, ver. 2.18.866 2018-04-04 13:56:23 +02:00
Milan Hanajik
701c2f33bb ErrorFlagsEx water meter results item, ver. 2.18.864 2018-03-28 16:58:36 +02:00
Milan Hanajik
dd8dce1d59 try { ... } catch when copying images. 2018-03-28 13:40:02 +02:00
Milan Hanajik
cd1bee1018 IControlCom : Interface uses uint[8] filterConstants (Juzna Afrika, Genesis), ver. 2.18.861 2018-03-27 13:16:54 +02:00
Milan Hanajik
9ac7f691e0 iPerlCommunicationForm bug fix, ver. 2.18.858 2018-03-26 14:17:51 +02:00
Milan Hanajik
bf1da91018 (1) Support for JUZNA_AFRIKA_50 symbol added, (2) Component JuznaAfrika50/ControlComponent3U added, ver. 2.18.857 2018-03-26 12:47:46 +02:00
Milan Hanajik
2efdb8bb61 Bug fixes in FixedStartSeq, ver. 2.18.854 2018-03-23 08:37:33 +01:00
Milan Hanajik
b9886599ed TestMethods.FixedStart added - uses only reference flowmeter, no scales, ver. 2.18.853 2018-03-22 21:03:13 +01:00
Milan Hanajik
9931138e5d (1) Minor improvements in Output.FileWriters.XmlBatch, (2) TestMethods.ReferenceFlowmeterCalibration removed, ver. 2.18.851 2018-03-20 01:40:58 +01:00
Milan Hanajik
be5122cec6 Output.FileWriters.XmlBatch component added, ver. 2.18.848 2018-03-19 09:27:57 +01:00
Milan Hanajik
5e50056f4a Output.DB.SaveFlowmeterCorrections tested and fixed, ver. 2.18.847 2018-03-19 06:31:30 +01:00
Milan Hanajik
0adec1cb51 Output.Printers.OnePerMeter : Table class added, common items use Table class for printing, ver. 2.18.844 2018-03-16 03:11:18 +01:00
Milan Hanajik
f8a358c21e Diverter and flowmeter numbers for diverter tests corrected for 3 Fuzhou benches. 2018-03-16 03:08:50 +01:00
Milan Hanajik
6a40a351a7 Output.DB.SaveFlowmeterCorrections works well with tests when Repeats count > 1. 2018-03-15 05:59:22 +01:00
Milan Hanajik
6a38189ee2 (1) Change in FUZHOU300 #if/#else/#endif, (2) UpgradeSelectionDlg supports v.2.4 -> v.2.9. DB upgrade, ver. 2.18.841 2018-03-14 07:30:15 +01:00
Milan Hanajik
47c2184d5f Fixes in FUZOU_40 define, ver. 2.18.837 2018-03-12 00:19:27 +01:00
Milan Hanajik
9b212bd455 (1) MettlerToledo.Multi workaround for Badger-stredna-trat at the serial protocol level, (2) VB1 display fixed, ver. 2.18.835 2018-03-11 12:10:53 +01:00
Milan Hanajik
62b06b23a5 MettlerToledo.Multi workaround for Badger-stredna-trat, ver. 2.18.833 2018-03-09 17:29:13 +01:00
Milan Hanajik
4452b62cbd Badger stredna trat : Flowmeter + diverter number when starting a test fixed, ver. 2.18.831 2018-03-09 12:25:58 +01:00
Milan Hanajik
9ab78cf824 Changes for Badger: (1) numerical keys passed to Elde component, (2) Diverter# for Badger stredna trat, ver. 2.18.828 2018-03-07 14:43:57 +01:00
Milan Hanajik
0598491753 SequenceBase.TestResult2CvsLine( ) bug fix, ver. 2.18.826 2018-02-26 20:40:19 +01:00
Milan Hanajik
88bf586da4 (3) Water density from air temperature uncorrected 2018-02-26 15:41:45 +01:00
Milan Hanajik
369753f94a (1) Water density calculated from temp. and pressure, (2) DensityOut -> DensityLine (mapped to DB column TestRslt.DensityOut), ver. 2.18.825 2018-02-26 15:30:22 +01:00
Milan Hanajik
29f79285a7 meterRslt.TestTime is read from board from cBrd.ImpulseTime(wmNr1) 2018-02-26 13:54:26 +01:00
Milan Hanajik
81951287c6 SequenceBase.TestResult2CsvLine( ) modified: isPressureTest, isStartStop, isDiverter, isCamera, ... 2018-02-26 13:13:36 +01:00
Milan Hanajik
be86f791e4 TestRslt.MethodClass and MeterTestRslt.RegReaderClass fields set appropriately in each test, ver. 2.18.824 2018-02-26 12:35:53 +01:00
Milan Hanajik
d8de284c37 TestResults2CsvLine( ) clean-up.. 2018-02-26 09:34:50 +01:00
Milan Hanajik
39d43bc217 TestResult2CsvLine() modifications for Kepno, ver. 2.18.823 2018-02-23 10:03:23 +01:00
Milan Hanajik
7bb6d7f0e9 Water density calculation according to ITS-90 2018-02-23 09:55:19 +01:00