Increment assembly version to 3.9.3102.1, enhance FlyingStartMassCollectionSeq by removing unused code, improve error handling for flow calculations in FlyingStartSeq, extend GenesisSmartReader integration, and introduce WaterMeterParentCopy method for multi-channel handling in test sequences.
This commit is contained in:
parent
0af975f670
commit
fde090c437
@ -32,5 +32,5 @@ using System.Runtime.InteropServices;
|
||||
// Build Number
|
||||
// Revision
|
||||
//
|
||||
[assembly: AssemblyVersion("3.9.3101.1")]
|
||||
[assembly: AssemblyFileVersion("3.9.3101.1")]
|
||||
[assembly: AssemblyVersion("3.9.3102.1")]
|
||||
[assembly: AssemblyFileVersion("3.9.3102.1")]
|
||||
|
||||
@ -12,6 +12,7 @@ using TBF.Rig;
|
||||
using TBF.Rig.GenericDevices;
|
||||
using TBF.Boxes;
|
||||
using TBF.Resources;
|
||||
using TBF.Rig.RegisterReaders.GenesisRegReader.implementations;
|
||||
using TBF.Rig.Uni.SharedDialogs.SmartMetersCommunication.common;
|
||||
using TBF.UiBridge;
|
||||
|
||||
@ -464,6 +465,11 @@ namespace TBF.Rig.TestMethods.FlyingStart
|
||||
}
|
||||
while (!e.Contains(Event.TestCompleted) && !e.Contains(Event.Next)); /// 'Next' button is enabled in Debug version only
|
||||
|
||||
|
||||
//------------------------------------------------
|
||||
Bridge.OnActivity(this, Strings.Test_in_calculation);
|
||||
//------------------------------------------------
|
||||
|
||||
/// Measurement loop end
|
||||
StopRecordingStatistics();
|
||||
|
||||
@ -532,7 +538,7 @@ namespace TBF.Rig.TestMethods.FlyingStart
|
||||
tstRslt.TimeBtwnMassMsrmnts = 0;
|
||||
tstRslt.ConstMasterRaw = outPath.FlowMeter.LtrPerPulse; /// Uncorrected master flowmeter coefficient
|
||||
tstRslt.VolumeMaster = tstRslt.ConstMasterRaw * tstRslt.PulsesMaster; /// [l] volume from the master flow meter
|
||||
double flowMID = 3.6 * tstRslt.VolumeMaster / tstRslt.TestTime; /// [m3/h]
|
||||
double flowMID = tstRslt.TestTime == 0 ? 0 : 3.6 * tstRslt.VolumeMaster / tstRslt.TestTime; /// [m3/h]
|
||||
|
||||
/// Corrected data
|
||||
tstRslt.MassStart = 0;
|
||||
@ -542,7 +548,7 @@ namespace TBF.Rig.TestMethods.FlyingStart
|
||||
|
||||
/// Main result calculation
|
||||
tstRslt.VolumeCTV = tstRslt.ConstMasterCorr * tstRslt.PulsesMaster; /// [l] 1000.0f is because density is in [kg/m3]
|
||||
tstRslt.Flow = 3.6 * tstRslt.VolumeCTV / tstRslt.TestTime;
|
||||
tstRslt.Flow = tstRslt.TestTime==0 ? 0 : 3.6 * tstRslt.VolumeCTV / tstRslt.TestTime;
|
||||
tstRslt.ErrorMaster = 0.0; /// Not available without a mass measurement
|
||||
tstRslt.ConstMaster = tstRslt.ConstMasterCorr;
|
||||
|
||||
@ -660,6 +666,7 @@ namespace TBF.Rig.TestMethods.FlyingStart
|
||||
TestMethods.iPerlCommunication.iPerlHead.IperlHead iPerl = regReader as TestMethods.iPerlCommunication.iPerlHead.IperlHead;
|
||||
GenericDevices.IRegReaderLiveCamera cameraRoi = regReader as GenericDevices.IRegReaderLiveCamera;
|
||||
//GenesisHead Genesis = regReader as GenesisHead;
|
||||
TBF.Rig.RegisterReaders.GenesisRegReader.implementations.GenesisSmartReader GenesisSmart = regReader as TBF.Rig.RegisterReaders.GenesisRegReader.implementations.GenesisSmartReader;
|
||||
|
||||
if (meterRslt != null && regReader != null)
|
||||
{
|
||||
@ -711,6 +718,24 @@ namespace TBF.Rig.TestMethods.FlyingStart
|
||||
Genesis.Log(" MeterError = " + calError.ToString() + " %");
|
||||
}
|
||||
else*/
|
||||
if (GenesisSmart != null)
|
||||
{
|
||||
log.Debug("GenesisSmart - store data on end!");
|
||||
int CH1=0, CH2=1, CH3=2;
|
||||
|
||||
CalculateMeterResults(meterRslt, GenesisSmart, tstRslt,GenesisSmart.TimestampSecStart, GenesisSmart.TimestampSecEnd, GenesisSmart.VolumeLtrStart, GenesisSmart.VolumeLtrEnd);
|
||||
|
||||
//Init Calculate Calibration
|
||||
GenesisSmart.RefVolume = meterRslt.VolumeRef;
|
||||
GenesisSmart.RefTime = meterRslt.TestTime;
|
||||
|
||||
//Store Raw Calibration Data to database
|
||||
WaterMeterParentCopy(i, CH1,testName,meterRslt,GenesisSmart,tstRslt);
|
||||
WaterMeterParentCopy(i, CH2,testName,meterRslt,GenesisSmart,tstRslt);
|
||||
WaterMeterParentCopy(i, CH3,testName,meterRslt,GenesisSmart,tstRslt);
|
||||
|
||||
}
|
||||
else
|
||||
{
|
||||
if (dstrReader != null)
|
||||
{
|
||||
@ -915,6 +940,97 @@ namespace TBF.Rig.TestMethods.FlyingStart
|
||||
// }
|
||||
// }
|
||||
|
||||
private const int CountCh = 3;
|
||||
private static void WaterMeterParentCopy(int i, int iCH, string testName, MeterTestRslt meterRslt,
|
||||
GenesisSmartReader genesisSmart,
|
||||
TestRslt tstRslt)
|
||||
{
|
||||
WaterMeter waterMeterParent = BatchRslts.Batch.WaterMeters[i];
|
||||
int wmNrChX = (i*CountCh) + BatchRslts.WMPositionsCount + iCH + 1;
|
||||
String sSerialNr = waterMeterParent.SerialNr + "_CH" + (iCH + 1);
|
||||
WaterMeter chXWaterMeter = null;
|
||||
//------ add new water meter to batch ------
|
||||
if (BatchRslts.Batch.WaterMeters.Count < wmNrChX || BatchRslts.Batch.WaterMeters[wmNrChX-1] == null)
|
||||
{
|
||||
log.Debug("add new water meter to batch, CH = " + (iCH + 1) + " CH = " + wmNrChX);
|
||||
chXWaterMeter = new WaterMeter()
|
||||
{
|
||||
Batch = BatchRslts.Batch,
|
||||
WaterMeterData = waterMeterParent.WaterMeterData,
|
||||
MeterTestRslts = new List<MeterTestRslt>(),
|
||||
SerialNr = sSerialNr,
|
||||
WMPosition = wmNrChX,
|
||||
YearOfProduction = 0,
|
||||
Disabled = false,
|
||||
};
|
||||
chXWaterMeter.CopyContentFrom(waterMeterParent);
|
||||
|
||||
chXWaterMeter.SerialNr = sSerialNr;
|
||||
chXWaterMeter.WMPosition = wmNrChX;
|
||||
chXWaterMeter.YearOfProduction = waterMeterParent.YearOfProduction;
|
||||
chXWaterMeter.Disabled = false;
|
||||
|
||||
BatchRslts.Batch.WaterMeters.Add(chXWaterMeter);
|
||||
}
|
||||
else
|
||||
{
|
||||
chXWaterMeter = BatchRslts.Batch.WaterMeters[wmNrChX-1];
|
||||
}
|
||||
//~------ add new water meter to batch ------~
|
||||
|
||||
//create copy of meterRslt and add to additionalResultsByChannel
|
||||
MeterTestRslt meterTestRsltChX = new MeterTestRslt(chXWaterMeter, meterRslt.TestRslt, (CompoundMeterId)meterRslt.CompoundMeterId);
|
||||
chXWaterMeter.MeterTestRslts.Add(meterTestRsltChX);
|
||||
MeterTestRslt chanelXMeterRslt = BatchRslts.GetMeterTestRslt(testName, wmNrChX-1, Common.CompoundMeterId.Single);
|
||||
|
||||
if (chanelXMeterRslt != null)
|
||||
{
|
||||
chanelXMeterRslt?.CopyContentFrom(meterRslt);
|
||||
if (iCH == 0)
|
||||
{
|
||||
CalculateMeterResults(chanelXMeterRslt, genesisSmart, tstRslt, genesisSmart.TimestampSecStartRawCh1,
|
||||
genesisSmart.TimestampSecEndRawCh1, genesisSmart.VolumeLtrStartRawCh1, genesisSmart.VolumeLtrEndRawCh1);
|
||||
}
|
||||
else if (iCH == 1)
|
||||
{
|
||||
CalculateMeterResults(chanelXMeterRslt, genesisSmart, tstRslt, genesisSmart.TimestampSecStartRawCh2,
|
||||
genesisSmart.TimestampSecEndRawCh2, genesisSmart.VolumeLtrStartRawCh2, genesisSmart.VolumeLtrEndRawCh2);
|
||||
}
|
||||
else if (iCH == 2)
|
||||
{
|
||||
CalculateMeterResults(chanelXMeterRslt, genesisSmart, tstRslt, genesisSmart.TimestampSecStartRawCh3,
|
||||
genesisSmart.TimestampSecEndRawCh3, genesisSmart.VolumeLtrStartRawCh3, genesisSmart.VolumeLtrEndRawCh3);
|
||||
}
|
||||
|
||||
if (!genesisSmart.EnableShowChanels)
|
||||
{
|
||||
chXWaterMeter.Disabled = !genesisSmart.EnableShowChanels;
|
||||
meterTestRsltChX.TestDone = false;
|
||||
}
|
||||
else
|
||||
{
|
||||
meterTestRsltChX.TestDone = true;
|
||||
}
|
||||
|
||||
meterTestRsltChX.Passed = meterRslt.Passed;
|
||||
}
|
||||
}
|
||||
|
||||
private static void CalculateMeterResults(MeterTestRslt meterRslt, IRegReaderDatastream dstrReader, TestRslt tstRslt, double dstrReaderTimestampSecStart, double dstrReaderTimestampSecEnd, double dstrReaderVolumeLtrStart, double dstrReaderVolumeLtrEnd)
|
||||
{
|
||||
meterRslt.TimestampStart = dstrReaderTimestampSecStart;
|
||||
meterRslt.TimestampEnd = !dstrReader.NoSamples
|
||||
? dstrReaderTimestampSecEnd
|
||||
: (dstrReaderTimestampSecStart + tstRslt.TestTime);
|
||||
meterRslt.TestTime = meterRslt.TimestampEnd - meterRslt.TimestampStart;
|
||||
meterRslt.VolumeStart = dstrReaderVolumeLtrStart; /// liter
|
||||
meterRslt.VolumeEnd = dstrReaderVolumeLtrEnd; /// liter
|
||||
meterRslt.VolumeMeter =
|
||||
Math.Abs(dstrReaderVolumeLtrEnd - dstrReaderVolumeLtrStart);
|
||||
meterRslt.VolumeRef = tstRslt.TestTime==0? tstRslt.VolumeCTV : tstRslt.VolumeCTV * meterRslt.TestTime / tstRslt.TestTime;
|
||||
meterRslt.PulsesMaster = tstRslt.TestTime == 0? tstRslt.PulsesMaster :
|
||||
tstRslt.PulsesMaster * meterRslt.TestTime / tstRslt.TestTime;
|
||||
}
|
||||
|
||||
IList<Event> Simulate(Config.Entities.Test test, int repetitionNr, bool isLastRepetition,
|
||||
Compound.TestParams compoundTestParams,
|
||||
|
||||
@ -1086,10 +1086,6 @@ namespace TBF.Rig.TestMethods.FlyingStartMassCollection
|
||||
bUpgradeCountOfMeters = true;
|
||||
int CH1=0, CH2=1, CH3=2;
|
||||
|
||||
//BatchRslts.Batch.WaterMeters.Add(ch1WaterMeter); //[i + BatchRslts.WMPositionsCount + CH1 + 1]
|
||||
//BatchRslts.Batch.WaterMeters.Add(ch1WaterMeter); //[i + BatchRslts.WMPositionsCount + CH2 + 1]
|
||||
//BatchRslts.Batch.WaterMeters.Add(ch1WaterMeter); //[i + BatchRslts.WMPositionsCount + CH3 + 1]
|
||||
|
||||
CalculateMeterResults(meterRslt, GenesisSmart, tstRslt,GenesisSmart.TimestampSecStart, GenesisSmart.TimestampSecEnd, GenesisSmart.VolumeLtrStart, GenesisSmart.VolumeLtrEnd);
|
||||
|
||||
//Init Calculate Calibration
|
||||
|
||||
Loading…