FixedStartMassCollection fixes, ver. 2.26.1770

This commit is contained in:
Milan Hanajik 2021-10-05 15:39:28 +02:00
parent 4021ed1a7b
commit f725c2d2d8
4 changed files with 41 additions and 24 deletions

View File

@ -630,8 +630,8 @@ namespace TBF.BenchControl.DataEntry.S620
foundMeters.Clear();
OracleCommand cmd2 = new OracleCommand("select VT_FERNUM, ZAEHLERNUMMER, HYDR_PRUEFUNG from VT_ZAEHLER_PD" +
" where ANBID=:1 AND AUFTRAGSNUMMER=:2 order by ZAEHLERNUMMER asc", connection);
OracleCommand cmd2 = new OracleCommand("SELECT vt_fernum, zaehlernummer, hydr_pruefung FROM vt_zaehler_pd" +
" WHERE anbid=:1 AND auftragsnummer=:2 ORDER BY zaehlernummer ASC", connection);
cmd2.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = ProcessData.OracleDB.Anbid_Producer }); ///:1
cmd2.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = orderNr }); ///:2

View File

@ -211,24 +211,28 @@ namespace TBF.BenchControl.Elde
double freqLo = 2000.0 * reqFlowLo / nominalFlow;
double freqHi = 2000.0 * reqFlowHi / nominalFlow;
if (regulValve.IsCoax)
if ((testMethod & TestMethods.FixedStart) == 0)
{
controlBoard.ValveMove(regulValveNr, RegulValveMode.TargetFrequency,
new float[2] { (float)((freqLo + freqHi) / 2), (float)((freqLo + freqHi) / 2) },
regulValveStableTime);
}
else if (regulValve is RegulValveMilwaukee.RegulValve)
{
controlBoard.ValveMove(regulValveNr, RegulValveMode.TargetFrequency,
new float[2] { (float)freqLo, (float)freqHi },
regulValveStableTime,
true);
}
else
{
controlBoard.ValveMove(regulValveNr, RegulValveMode.TargetFrequency,
new float[2] { (float)freqLo, (float)freqHi },
regulValveStableTime);
/// This is not a fixed start method => Start flow regulation
if (regulValve.IsCoax)
{
controlBoard.ValveMove(regulValveNr, RegulValveMode.TargetFrequency,
new float[2] { (float)((freqLo + freqHi) / 2), (float)((freqLo + freqHi) / 2) },
regulValveStableTime);
}
else if (regulValve is RegulValveMilwaukee.RegulValve)
{
controlBoard.ValveMove(regulValveNr, RegulValveMode.TargetFrequency,
new float[2] { (float)freqLo, (float)freqHi },
regulValveStableTime,
true);
}
else
{
controlBoard.ValveMove(regulValveNr, RegulValveMode.TargetFrequency,
new float[2] { (float)freqLo, (float)freqHi },
regulValveStableTime);
}
}
opState = OpState.OpCompleted;

View File

@ -427,6 +427,20 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
temperature_set:
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperations(readTempPressOps)
.AddOperation(cBrd.StartMeasurementOp(outPath, (Elde.TestMethods.Diverter | Elde.TestMethods.FixedStart),
test.Qfrom, test.Qto, 2 * totalPulses, 10))
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.MeasurementStarted));
//-----------------------------------------------------------------
Bridge.OnActivity(this, Strings.Stopping_flow_for_the_fixed_start);
//-----------------------------------------------------------------
@ -620,15 +634,14 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
.AddOperation(checkUiOp)
.AddOperations(readTempPressOps)
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, false, outPath)) /// This line should precede StartMeasureentOp (sending commands)
.AddOperation(cBrd.StartMeasurementOp(outPath, (Elde.TestMethods.Diverter | Elde.TestMethods.FixedStart),
test.Qfrom, test.Qto, 2 * totalPulses, 10))
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, RefFlow, int.MaxValue))
.EnterState();
do {
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.MeasurementStarted) || !e.Contains(Event.ValvesSet));
while (!e.Contains(Event.ValvesSet));
switchTimeStart = 0.001f * cBrd.ValveOpenCloseTime;
log.WarnFormat("Start valve switch time on test start = {0} ms", cBrd.ValveOpenCloseTime);

View File

@ -29,5 +29,5 @@ using System.Runtime.InteropServices;
// Build Number
// Revision
//
[assembly: AssemblyVersion("2.26.1769.0")]
[assembly: AssemblyFileVersion("2.26.1769.0")]
[assembly: AssemblyVersion("2.26.1770.0")]
[assembly: AssemblyFileVersion("2.26.1770.0")]