BugFix in ...Elde.StartMeasurementOp for the case of RV=...Elde.RegulValveCoax.RegulValve
This commit is contained in:
parent
67a762e51c
commit
86601e1ba1
@ -15,6 +15,7 @@ namespace TBF.BenchControl.Elde
|
|||||||
readonly ControlBoardDev controlBoard;
|
readonly ControlBoardDev controlBoard;
|
||||||
readonly Elde.RegulValve.RegulValve regulValve;
|
readonly Elde.RegulValve.RegulValve regulValve;
|
||||||
readonly int regulValveNr;
|
readonly int regulValveNr;
|
||||||
|
readonly int regulValveStableTime;
|
||||||
readonly int flowMeterNr;
|
readonly int flowMeterNr;
|
||||||
readonly float nominalFlow;
|
readonly float nominalFlow;
|
||||||
readonly float reqFlowLo;
|
readonly float reqFlowLo;
|
||||||
@ -80,10 +81,17 @@ namespace TBF.BenchControl.Elde
|
|||||||
|
|
||||||
if (outputPath.RegulValve is Elde.RegulValve.RegulValve)
|
if (outputPath.RegulValve is Elde.RegulValve.RegulValve)
|
||||||
{
|
{
|
||||||
regulValve = outputPath.RegulValve as Elde.RegulValve.RegulValve;
|
Elde.RegulValve.RegulValve rv = outputPath.RegulValve as Elde.RegulValve.RegulValve;
|
||||||
regulValveNr = this.regulValve.Idx1;
|
regulValveNr = rv.Idx1;
|
||||||
}
|
regulValveStableTime = rv.StableTime;
|
||||||
else if (!(outputPath.RegulValve is Dummy.RegulValve.RegulValve))
|
}
|
||||||
|
else if (outputPath.RegulValve is Elde.RegulValveCoax.RegulValve)
|
||||||
|
{
|
||||||
|
Elde.RegulValveCoax.RegulValve rv = outputPath.RegulValve as Elde.RegulValveCoax.RegulValve;
|
||||||
|
regulValveNr = rv.Idx1;
|
||||||
|
regulValveStableTime = rv.StableTime;
|
||||||
|
}
|
||||||
|
else if (!(outputPath.RegulValve is Dummy.RegulValve.RegulValve))
|
||||||
{
|
{
|
||||||
throw new ArgumentNullException("Regulation valve is not compatible with Elde Control Board");
|
throw new ArgumentNullException("Regulation valve is not compatible with Elde Control Board");
|
||||||
}
|
}
|
||||||
@ -183,7 +191,7 @@ namespace TBF.BenchControl.Elde
|
|||||||
float freqHi = 2000.0f * reqFlowHi / nominalFlow;
|
float freqHi = 2000.0f * reqFlowHi / nominalFlow;
|
||||||
controlBoard.ValveMove(regulValveNr, RegulValveMode.TargetFrequency,
|
controlBoard.ValveMove(regulValveNr, RegulValveMode.TargetFrequency,
|
||||||
new float[2] { freqLo, freqHi },
|
new float[2] { freqLo, freqHi },
|
||||||
regulValve.StableTime);
|
regulValveStableTime);
|
||||||
|
|
||||||
opState = OpState.OpCompleted;
|
opState = OpState.OpCompleted;
|
||||||
return Event.None;
|
return Event.None;
|
||||||
|
|||||||
Loading…
Reference in New Issue
Block a user