Merge branch 'feature/task_3-new-pump-grundfoss' into develop/SLM-PT50
This commit is contained in:
commit
3773e1d96c
@ -67,11 +67,13 @@ namespace TBF.Rig.BuiltIn.PumpTandem
|
||||
if (pump1 is BuiltIn.Pump.Pump) { mask1 = (pump1 as BuiltIn.Pump.Pump).Mask; }
|
||||
else if (pump1 is Danfoss.VLT2800.Pump) { mask1 = (pump1 as Danfoss.VLT2800.Pump).Mask; }
|
||||
else if (pump1 is Modbus.PumpFM.DanfossVLT.Pump) { mask1 = (pump1 as Modbus.PumpFM.DanfossVLT.Pump).Mask; }
|
||||
else if (pump1 is Modbus.PumpFM.Grundfoss.Pump) { mask1 = (pump1 as Modbus.PumpFM.Grundfoss.Pump).Mask; }
|
||||
else { mask1 = 0; }
|
||||
|
||||
if (pump2 is BuiltIn.Pump.Pump) { mask2 = (pump2 as BuiltIn.Pump.Pump).Mask; }
|
||||
else if (pump2 is Danfoss.VLT2800.Pump) { mask2 = (pump2 as Danfoss.VLT2800.Pump).Mask; }
|
||||
else if (pump2 is Modbus.PumpFM.DanfossVLT.Pump) { mask2 = (pump2 as Modbus.PumpFM.DanfossVLT.Pump).Mask; }
|
||||
else if (pump2 is Modbus.PumpFM.Grundfoss.Pump) { mask2 = (pump2 as Modbus.PumpFM.Grundfoss.Pump).Mask; }
|
||||
else { mask2 = 0; }
|
||||
|
||||
log.FatalFormat("{0} initialized: {1}", Name, this);
|
||||
|
||||
@ -44,6 +44,7 @@ namespace TBF.Rig.BuiltIn.PumpTandem
|
||||
if (TbfComponents.CmpntFactoryFromClassName(cmpnt.ClassName) is BuiltIn.Pump.PumpFactory ||
|
||||
TbfComponents.CmpntFactoryFromClassName(cmpnt.ClassName) is Danfoss.VLT2800.PumpFactory ||
|
||||
TbfComponents.CmpntFactoryFromClassName(cmpnt.ClassName) is Modbus.PumpFM.DanfossVLT.Factory ||
|
||||
TbfComponents.CmpntFactoryFromClassName(cmpnt.ClassName) is Modbus.PumpFM.Grundfoss.Factory ||
|
||||
TbfComponents.CmpntFactoryFromClassName(cmpnt.ClassName) is BuiltIn.PumpTandem.PumpFactory)
|
||||
{
|
||||
pump1ComboBox.Items.Add(cmpnt.Name);
|
||||
|
||||
@ -120,7 +120,8 @@ namespace TBF.Rig.BuiltIn
|
||||
if (valve is PumpTandem.Pump) point.MasksOpen |= (valve as PumpTandem.Pump).Mask;
|
||||
if (valve is Danfoss.VLT2800.Pump) point.MasksOpen |= (valve as Danfoss.VLT2800.Pump).Mask;
|
||||
if (valve is Modbus.PumpFM.DanfossVLT.Pump) point.MasksOpen |= (valve as Modbus.PumpFM.DanfossVLT.Pump).Mask;
|
||||
}
|
||||
if (valve is Modbus.PumpFM.Grundfoss.Pump) point.MasksOpen |= (valve as Modbus.PumpFM.Grundfoss.Pump).Mask;
|
||||
}
|
||||
point.MasksClose = 0;
|
||||
foreach (var valve in point.VClose)
|
||||
{
|
||||
@ -129,7 +130,8 @@ namespace TBF.Rig.BuiltIn
|
||||
if (valve is PumpTandem.Pump) point.MasksClose |= (valve as PumpTandem.Pump).Mask;
|
||||
if (valve is Danfoss.VLT2800.Pump) point.MasksClose |= (valve as Danfoss.VLT2800.Pump).Mask;
|
||||
if (valve is Modbus.PumpFM.DanfossVLT.Pump) point.MasksClose |= (valve as Modbus.PumpFM.DanfossVLT.Pump).Mask;
|
||||
}
|
||||
if (valve is Modbus.PumpFM.Grundfoss.Pump) point.MasksClose |= (valve as Modbus.PumpFM.Grundfoss.Pump).Mask;
|
||||
}
|
||||
point.TimeSec += timeShift;
|
||||
}
|
||||
}
|
||||
|
||||
@ -35,6 +35,7 @@ namespace TBF.Rig.BuiltIn
|
||||
if (vlv is Pump.Pump && ((vlv as Pump.Pump).Mask & changed) == 0) continue;
|
||||
if (vlv is Danfoss.VLT2800.Pump && ((vlv as Danfoss.VLT2800.Pump).Mask & changed) == 0) continue;
|
||||
if (vlv is Modbus.PumpFM.DanfossVLT.Pump && ((vlv as Modbus.PumpFM.DanfossVLT.Pump).Mask & changed) == 0) continue;
|
||||
if (vlv is Modbus.PumpFM.Grundfoss.Pump && ((vlv as Modbus.PumpFM.Grundfoss.Pump).Mask & changed) == 0) continue;
|
||||
|
||||
if ((vlv != null) && (vlv.Delay > max)) max = vlv.Delay;
|
||||
}
|
||||
@ -45,6 +46,7 @@ namespace TBF.Rig.BuiltIn
|
||||
if (vlv is Pump.Pump && ((vlv as Pump.Pump).Mask & changed) == 0) continue;
|
||||
if (vlv is Danfoss.VLT2800.Pump && ((vlv as Danfoss.VLT2800.Pump).Mask & changed) == 0) continue;
|
||||
if (vlv is Modbus.PumpFM.DanfossVLT.Pump && ((vlv as Modbus.PumpFM.DanfossVLT.Pump).Mask & changed) == 0) continue;
|
||||
if (vlv is Modbus.PumpFM.Grundfoss.Pump && ((vlv as Modbus.PumpFM.Grundfoss.Pump).Mask & changed) == 0) continue;
|
||||
|
||||
if ((vlv != null) && (vlv.Delay > max)) max = vlv.Delay;
|
||||
}
|
||||
|
||||
25
TBF/Rig/Modbus/PumpFM/Grundfoss/Factory.cs
Normal file
25
TBF/Rig/Modbus/PumpFM/Grundfoss/Factory.cs
Normal file
@ -0,0 +1,25 @@
|
||||
///
|
||||
/// Copyright (c) 2020 Sensus Slovensko a.s.
|
||||
///
|
||||
using System.Collections.Generic;
|
||||
using TBF.Rig.Generic;
|
||||
|
||||
namespace TBF.Rig.Modbus.PumpFM.Grundfoss
|
||||
{
|
||||
public class Factory : IComponentFactory
|
||||
{
|
||||
public string ClassName { get { return this.GetType().Namespace.Substring(8); } }
|
||||
public override string ToString() { return ClassName; }
|
||||
|
||||
public IComponent DummyComponent() { return new Pump(); }
|
||||
|
||||
public IComponent GetComponent(IComponentCfg cfg, IList<IComponent> components) { return new Pump(cfg, components); }
|
||||
|
||||
public IComponentCfg DefaultConfig() { return new PumpCfg(this); }
|
||||
|
||||
public IComponentCfg CmpntCfgFromCmpntEntity(Config.Entities.Component component)
|
||||
{
|
||||
return ComponentCfgBase.CreateFromDbEntity(PumpCfg.Serializer, component, this);
|
||||
}
|
||||
}
|
||||
}
|
||||
497
TBF/Rig/Modbus/PumpFM/Grundfoss/Pump.cs
Normal file
497
TBF/Rig/Modbus/PumpFM/Grundfoss/Pump.cs
Normal file
@ -0,0 +1,497 @@
|
||||
using Common;
|
||||
using Dirichlet.Numerics;
|
||||
using log4net;
|
||||
using SchematicDrawing;
|
||||
using SharedComponents;
|
||||
///
|
||||
/// Copyright (c) 2020 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.Diagnostics;
|
||||
using TBF.Rig.ControlBoard;
|
||||
using TBF.Rig.Generic;
|
||||
|
||||
namespace TBF.Rig.Modbus.PumpFM.Grundfoss
|
||||
{
|
||||
/// <summary>
|
||||
/// See page 20 of MG10S202 Operational Instructions Modbus RTU
|
||||
/// </summary>
|
||||
public enum CW : ushort
|
||||
{
|
||||
PresetRefLsb = (1 << 0),
|
||||
PresetRefMsb = (1 << 1),
|
||||
Not_DcBraking = (1 << 2),
|
||||
Not_CoastingStop = (1 << 3),
|
||||
Not_QuickStop = (1 << 4),
|
||||
Not_FreezeFreq = (1 << 5),
|
||||
Start_NotRampStop = (1 << 6),
|
||||
Reset = (1 << 7),
|
||||
Jog = (1 << 8),
|
||||
Ramp2_NotRamp1 = (1 << 9),
|
||||
DataValid = (1 << 10),
|
||||
Relay01Activ = (1 << 11),
|
||||
DOut46Activ = (1 << 12),
|
||||
SelectSetupLsb = (1 << 13),
|
||||
SelectSetupMsb = (1 << 14),
|
||||
Reversing = (1 << 15),
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// See page 22 of MG10S202 Operational Instructions Modbus RTU
|
||||
/// </summary>
|
||||
public enum SW : ushort
|
||||
{
|
||||
ControlReady = (1 << 0),
|
||||
DriveReady = (1 << 1),
|
||||
CoastingStop = (1 << 2),
|
||||
Trip = (1 << 3),
|
||||
TripLock = (1 << 6),
|
||||
Warning = (1 << 7),
|
||||
SpeedEqRef = (1 << 8),
|
||||
RemoteCtrl = (1 << 9),
|
||||
FreqLimitOK = (1 << 10),
|
||||
MotorRunning = (1 << 11),
|
||||
VoltageWarn = (1 << 13),
|
||||
CurrentLimit = (1 << 14),
|
||||
ThermalWarn = (1 << 15),
|
||||
}
|
||||
|
||||
public enum Function : byte
|
||||
{
|
||||
ReadCoilStatus = 0x01,
|
||||
ForceSingleCoil = 0x05,
|
||||
ForceMultipleCoils = 0x0F,
|
||||
ReadHoldingRegisters = 0x03,
|
||||
PresetSingleRegister = 0x06,
|
||||
PresetMultipleRegisters = 0x10,
|
||||
}
|
||||
|
||||
|
||||
public class Pump : ComponentBase, IDevice, IOperation, GenericDevices.IPumpFM, GenericDevices.IValve, IDrawingItCmpntWithSetpoint
|
||||
{
|
||||
private static readonly ILog log = LogManager.GetLogger(typeof(Pump));
|
||||
public override string ToString() { return string.Format("{0}({1})", ClassName, Cfg.ToString(-1)); }
|
||||
|
||||
private readonly PumpCfg pumpCfg;
|
||||
public IDrawingItem DrawingItem { get { return pumpCfg as IDrawingItem; } }
|
||||
|
||||
public int Delay { get { return pumpCfg.Delay; } }
|
||||
public ValveCategory Category { get { return ValveCategory.Feeding; } } /// Pump category is Feeding
|
||||
public GenericDevices.IValve CoupledTo { get { return null; } }
|
||||
public bool InvertCouple { get { return false; } }
|
||||
public int LagOpening { get { return 0; } }
|
||||
public int LagClosing { get { return 0; } }
|
||||
|
||||
/// <summary>
|
||||
/// Pump power in [%] in range 0 .. 100.0
|
||||
/// </summary>
|
||||
double power;
|
||||
public double Power { get { return power; } }
|
||||
///
|
||||
public double SetpointVal
|
||||
{
|
||||
get { return power; }
|
||||
set
|
||||
{
|
||||
power = (float)value;
|
||||
if (power != 0) TurnOn(power);
|
||||
}
|
||||
}
|
||||
///
|
||||
public void IncreaseSetpoint()
|
||||
{
|
||||
power += 3.0;
|
||||
if (power > 100.0) power = 100.0;
|
||||
TurnOn(power);
|
||||
}
|
||||
///
|
||||
public void DecreaseSetpoint()
|
||||
{
|
||||
power -= 3.0;
|
||||
if (power <= 0)
|
||||
{
|
||||
power = 0;
|
||||
TurnOff();
|
||||
}
|
||||
else
|
||||
{
|
||||
TurnOn(power);
|
||||
}
|
||||
}
|
||||
|
||||
Common.Modbus modbus;
|
||||
IControlBoard controlBoard;
|
||||
int bitNr; /// 0 .. 63
|
||||
public UInt128 Mask; /// derived from bitPosition in the constructor
|
||||
|
||||
public bool State { get { return (controlBoard.Route & Mask) != 0; } }
|
||||
|
||||
|
||||
public Pump() { }
|
||||
|
||||
/// <summary>
|
||||
/// Ambient temperature / humidity / pressure meter 'Greco' connected via serial interface (RS232)
|
||||
/// Connection settings: 19200 Bd 8-bits No-parity 1-stop-bit Flow control: none or hardware.
|
||||
/// </summary>
|
||||
public Pump(Generic.IComponentCfg cfg, IList<Generic.IComponent> components)
|
||||
: base(cfg)
|
||||
{
|
||||
pumpCfg = cfg as PumpCfg;
|
||||
}
|
||||
public override void Initialize()
|
||||
{
|
||||
if (DebugLevel == DebugMode.Normal || DebugLevel == DebugMode.DetectedOn)
|
||||
{
|
||||
modbus = TbfComponents.FindComponent(pumpCfg.ParentName) as Common.Modbus;
|
||||
if (modbus == null) throw new Exception("Cannot find " + Name + " parent");
|
||||
|
||||
controlBoard = null;
|
||||
foreach (var name in new string[] { "CB", "UniCB" })
|
||||
{
|
||||
if ((controlBoard = TbfComponents.FindComponent(name) as IControlBoard) != null)
|
||||
break;
|
||||
}
|
||||
if (controlBoard == null) throw new Exception("Cannot find a control board");
|
||||
|
||||
bitNr = pumpCfg.BitNr;
|
||||
Mask = (((UInt128)1) << bitNr);
|
||||
modbus.ComponentNames[pumpCfg.ModbusAddress] = Name;
|
||||
|
||||
TBF.UiBridge.Bridge.SetpointChangeHandler += delegate(object sndr, TBF.UiBridge.SetpointChangeArgs args)
|
||||
{
|
||||
if (args.Name == Name)
|
||||
{
|
||||
if (args.Increase) IncreaseSetpoint(); else DecreaseSetpoint();
|
||||
}
|
||||
};
|
||||
|
||||
log.FatalFormat("{0} initialized: {1}", Name, this);
|
||||
}
|
||||
else
|
||||
{
|
||||
log.FatalFormat("{0} simulated: {1}", Name, this);
|
||||
}
|
||||
}
|
||||
|
||||
///
|
||||
/// IDevice interface
|
||||
///
|
||||
public void RunDeviceBefore()
|
||||
{
|
||||
/*if (DebugLevel == DebugMode.Normal || DebugLevel == DebugMode.DetectedOn)
|
||||
{
|
||||
if (modbus.ReceivedTelegrams[pumpCfg.ModbusAddress].Count > 0)
|
||||
{
|
||||
byte[] telegram = modbus.ReceivedTelegrams[pumpCfg.ModbusAddress].Dequeue();
|
||||
string s = Telegram.LogTelegram(string.Format("Telegram received from {0}: ", Name), telegram);
|
||||
log.Warn(s);
|
||||
}
|
||||
}*/
|
||||
|
||||
if (DebugLevel == DebugMode.Normal || DebugLevel == DebugMode.DetectedOn)
|
||||
{
|
||||
if (modbus.ReceivedTelegrams[pumpCfg.ModbusAddress].Count > 0)
|
||||
{
|
||||
try
|
||||
{
|
||||
byte[] telegram = modbus.ReceivedTelegrams[pumpCfg.ModbusAddress].Dequeue();
|
||||
|
||||
string hex = BitConverter.ToString(telegram).Replace("-", " ");
|
||||
|
||||
string msg = $"Telegram received from {Name}: {hex}";
|
||||
|
||||
log.Warn(msg);
|
||||
|
||||
LiveLogDiag.Log1(msg);
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
log.Error($"RunDeviceBefore() – error processing telegram: {ex}");
|
||||
LiveLogDiag.Log1($"RunDeviceBefore() – error processing telegram: {ex.Message}");
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
public void RunDeviceAfter() { }
|
||||
public void StopDevice() { }
|
||||
public void StopDevice2() { }
|
||||
|
||||
|
||||
/*/// <summary>
|
||||
/// Turn the pmp on using Modbus commad, use the variable frequency
|
||||
/// </summary>
|
||||
/// <param name="powerArg">Frequency in percent (-200.0 .. 200.0)</param>
|
||||
public void TurnOn(double powerArg)
|
||||
{
|
||||
log.DebugFormat("{0}.TurnOn({1})", Name, powerArg);
|
||||
|
||||
UInt16 controlWord = (UInt16)(CW.Not_DcBraking |
|
||||
CW.Not_CoastingStop |
|
||||
CW.Not_QuickStop |
|
||||
CW.Not_FreezeFreq |
|
||||
CW.Start_NotRampStop |
|
||||
CW.DataValid);
|
||||
this.power = powerArg;
|
||||
UInt16 reference = (UInt16)Math.Round(0x4000 * powerArg / 100.0);
|
||||
|
||||
if (DebugLevel == DebugMode.Normal || DebugLevel == DebugMode.DetectedOn)
|
||||
{
|
||||
byte[] msg = new byte[13];
|
||||
msg[0] = (byte)pumpCfg.ModbusAddress;
|
||||
msg[1] = (byte)Function.ForceMultipleCoils;
|
||||
msg[2] = 0; /// Data Hi
|
||||
msg[3] = 0; /// Data Lo
|
||||
msg[4] = 0; /// Nr. of coils Hi
|
||||
msg[5] = 0x20; /// Nr. of coils Lo
|
||||
msg[6] = 4; /// Byte count
|
||||
msg[7] = (byte)(controlWord & 0xFF); /// Control Word Lo
|
||||
msg[8] = (byte)(controlWord >> 8); /// Control Word Hi
|
||||
msg[9] = (byte)(reference & 0xFF); /// Serial Com Reference Lo
|
||||
msg[10] = (byte)(reference >> 8); /// Serial Com Reference Hi
|
||||
///
|
||||
modbus.SendMessage(msg, Name);
|
||||
|
||||
/// --- DIAGNOSTIKA ---
|
||||
LiveLogDiag.Log1("--------------------------------------------");
|
||||
LiveLogDiag.Log1($"TurnOff controlWord=0x{controlWord:X4}");
|
||||
LiveLogDiag.Log1($"TurnOff reference={reference}");
|
||||
|
||||
LiveLogDiag.Log1("TurnOff msg = " + BitConverter.ToString(msg));
|
||||
}
|
||||
}*/
|
||||
|
||||
public void TurnOn(double powerArg)
|
||||
{
|
||||
log.DebugFormat("{0}.TurnOn({1})", Name, powerArg);
|
||||
|
||||
LiveLogDiag.Log1("--------------------------------------------");
|
||||
LiveLogDiag.Log1("{0}.TurnOn({1})", Name, powerArg);
|
||||
LiveLogDiag.Log1($"DebugLevel={DebugLevel}");
|
||||
|
||||
// clamp 0–100 %
|
||||
double pct = Math.Max(0, Math.Min(100.0, powerArg));
|
||||
UInt16 setpoint = (UInt16)Math.Round(pct * 100); // fH,fL = %*100
|
||||
this.power = pct;
|
||||
|
||||
if (DebugLevel == DebugMode.Normal || DebugLevel == DebugMode.DetectedOn)
|
||||
{
|
||||
byte[] msg = new byte[17];
|
||||
|
||||
msg[0] = (byte)pumpCfg.ModbusAddress; // adr
|
||||
msg[1] = 0x10; // function = write multiple registers
|
||||
msg[2] = 0x00; // start address hi
|
||||
msg[3] = 0x64; // start address lo = 100
|
||||
msg[4] = 0x00; // register count hi
|
||||
msg[5] = 0x05; // register count lo = 5
|
||||
msg[6] = 0x0A; // byte count = 10
|
||||
|
||||
// ----- registers -----
|
||||
|
||||
// reg100 = command = 0x0007 (RUN)
|
||||
msg[7] = 0x00;
|
||||
msg[8] = 0x07;
|
||||
|
||||
// reg101 = 0x0001
|
||||
msg[9] = 0x00;
|
||||
msg[10] = 0x01;
|
||||
|
||||
// reg102 = 0x0000
|
||||
msg[11] = 0x00;
|
||||
msg[12] = 0x00;
|
||||
|
||||
// reg103 = setpoint = fH,fL
|
||||
msg[13] = (byte)(setpoint >> 8);
|
||||
msg[14] = (byte)(setpoint & 0xFF);
|
||||
|
||||
// reg104 = 0x0001 (RUN)
|
||||
msg[15] = 0x00;
|
||||
msg[16] = 0x01;
|
||||
|
||||
//Telegram.UpdateTelegramCRC(msg);
|
||||
modbus.SendMessage(msg, Name);
|
||||
modbus.SendMessage(msg, Name);
|
||||
|
||||
// --- DIAGNOSTIKA ---
|
||||
LiveLogDiag.Log1($"GF TurnOn Setpoint={pct}");
|
||||
LiveLogDiag.Log1($"GF TurnOn raw reference={setpoint}");
|
||||
LiveLogDiag.Log1("GF TurnOn msg = " + BitConverter.ToString(msg));
|
||||
}
|
||||
}
|
||||
|
||||
/*/// <summary>
|
||||
/// Turn the pmp off using Modbus command
|
||||
/// </summary>
|
||||
public void TurnOff()
|
||||
{
|
||||
log.DebugFormat("{0}.TurnOff()", Name);
|
||||
|
||||
UInt16 controlWord = (UInt16)(CW.Not_DcBraking |
|
||||
CW.Not_CoastingStop |
|
||||
CW.Not_QuickStop |
|
||||
CW.Not_FreezeFreq |
|
||||
//CW.Start_NotRampStop |
|
||||
CW.DataValid);
|
||||
this.power = 0;
|
||||
UInt16 reference = 0;
|
||||
|
||||
if (DebugLevel == DebugMode.Normal || DebugLevel == DebugMode.DetectedOn)
|
||||
{
|
||||
byte[] msg = new byte[13];
|
||||
msg[0] = (byte)pumpCfg.ModbusAddress;
|
||||
msg[1] = (byte)Function.ForceMultipleCoils;
|
||||
msg[2] = 0; /// Data Hi
|
||||
msg[3] = 0; /// Data Lo
|
||||
msg[4] = 0; /// Nr. of coils Hi
|
||||
msg[5] = 0x20; /// Nr. of coils Lo
|
||||
msg[6] = 4; /// Byte count
|
||||
msg[7] = (byte)(controlWord & 0xFF); /// Control Word Lo
|
||||
msg[8] = (byte)(controlWord >> 8); /// Control Word Hi
|
||||
msg[9] = (byte)(reference & 0xFF); /// Serial Com Reference Lo
|
||||
msg[10] = (byte)(reference >> 8); /// Serial Com Reference Hi
|
||||
Telegram.UpdateTelegramCRC(msg);
|
||||
|
||||
modbus.SendMessage(msg, Name);
|
||||
|
||||
/// --- DIAGNOSTIKA ---
|
||||
LiveLogDiag.Log1("--------------------------------------------");
|
||||
LiveLogDiag.Log1($"TurnOff controlWord=0x{controlWord:X4}");
|
||||
LiveLogDiag.Log1($"TurnOff reference={reference}");
|
||||
|
||||
LiveLogDiag.Log1("TurnOff msg = " + BitConverter.ToString(msg));
|
||||
}
|
||||
}*/
|
||||
|
||||
/// <summary>
|
||||
/// Turn the pump off using Modbus command (Grundfos version)
|
||||
/// </summary>
|
||||
public void TurnOff()
|
||||
{
|
||||
log.DebugFormat("{0}.TurnOff()", Name);
|
||||
|
||||
LiveLogDiag.Log1("--------------------------------------------");
|
||||
LiveLogDiag.Log1("{0}.TurnOff()", Name);
|
||||
LiveLogDiag.Log1($"DebugLevel={DebugLevel}");
|
||||
|
||||
this.power = 0;
|
||||
UInt16 setpoint = 0; // desired = 0%
|
||||
|
||||
if (DebugLevel == DebugMode.Normal || DebugLevel == DebugMode.DetectedOn)
|
||||
{
|
||||
byte[] msg = new byte[17];
|
||||
|
||||
msg[0] = (byte)pumpCfg.ModbusAddress; // adr
|
||||
msg[1] = 0x10; // function
|
||||
msg[2] = 0x00;
|
||||
msg[3] = 0x64; // reg100
|
||||
msg[4] = 0x00;
|
||||
msg[5] = 0x05; // 5 registers
|
||||
msg[6] = 0x0A; // 10 bytes
|
||||
|
||||
// reg100 = 0x0005 (STOP)
|
||||
msg[7] = 0x00;
|
||||
msg[8] = 0x05;
|
||||
|
||||
// reg101 = 0x0001
|
||||
msg[9] = 0x00;
|
||||
msg[10] = 0x01;
|
||||
|
||||
// reg102 = 0x0000
|
||||
msg[11] = 0x00;
|
||||
msg[12] = 0x00;
|
||||
|
||||
// reg103 = setpoint = 0
|
||||
msg[13] = 0x00;
|
||||
msg[14] = 0x00;
|
||||
|
||||
// reg104 = 0x0000 (STOP)
|
||||
msg[15] = 0x00;
|
||||
msg[16] = 0x00;
|
||||
|
||||
//Telegram.UpdateTelegramCRC(msg);
|
||||
modbus.SendMessage(msg, Name);
|
||||
modbus.SendMessage(msg, Name);
|
||||
|
||||
// --- DIAGNOSTIKA ---
|
||||
LiveLogDiag.Log1("GF TurnOff msg = " + BitConverter.ToString(msg));
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// The currently running operation.
|
||||
/// </summary>
|
||||
public enum CurrentOp
|
||||
{
|
||||
None,
|
||||
TurnOn,
|
||||
TurnOff,
|
||||
}
|
||||
///
|
||||
CurrentOp currentOp;
|
||||
|
||||
double powerForOp;
|
||||
|
||||
/// <summary>
|
||||
/// Turn the pump frequency inverter on.
|
||||
/// </summary>
|
||||
public IOperation TurnOnOp(double powerArg)
|
||||
{
|
||||
if (currentOp != CurrentOp.None) throw new Exception("Sequence error");
|
||||
currentOp = CurrentOp.TurnOn;
|
||||
powerForOp = powerArg;
|
||||
return this;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Turn the pump frequency inverter on.
|
||||
/// </summary>
|
||||
public IOperation TurnOffOp()
|
||||
{
|
||||
if (currentOp != CurrentOp.None) throw new Exception("Sequence error");
|
||||
currentOp = CurrentOp.TurnOff;
|
||||
return this;
|
||||
}
|
||||
|
||||
/// <summary>Start the operation</summary>
|
||||
public void Start()
|
||||
{
|
||||
switch (currentOp)
|
||||
{
|
||||
case CurrentOp.TurnOn:
|
||||
TurnOn(powerForOp);
|
||||
return;
|
||||
|
||||
case CurrentOp.TurnOff:
|
||||
default:
|
||||
TurnOff();
|
||||
return;
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>Run the operation</summary>
|
||||
public Event Run()
|
||||
{
|
||||
return Event.TurnPumpOnOffDone;
|
||||
}
|
||||
|
||||
/// <summary>Stop the operation</summary>
|
||||
public void Stop()
|
||||
{
|
||||
currentOp = CurrentOp.None;
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Diagnostic logging
|
||||
/// Activated by compilation condition: DIAG_ENDURANCE_LOG
|
||||
/// </summary>
|
||||
static class LiveLogDiag
|
||||
{
|
||||
[Conditional("DIAG_LOG_PUMP")]
|
||||
public static void Log1(string format, params object[] args)
|
||||
{
|
||||
LiveLogCache.Instance.AddLog(string.Format(format, args));
|
||||
}
|
||||
}
|
||||
}
|
||||
84
TBF/Rig/Modbus/PumpFM/Grundfoss/PumpCfg.cs
Normal file
84
TBF/Rig/Modbus/PumpFM/Grundfoss/PumpCfg.cs
Normal file
@ -0,0 +1,84 @@
|
||||
///
|
||||
/// Copyright (c) 2020 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.Xml.Serialization;
|
||||
using Common;
|
||||
using Config.Entities;
|
||||
using SchematicDrawing;
|
||||
using TBF.Rig.Generic;
|
||||
|
||||
namespace TBF.Rig.Modbus.PumpFM.Grundfoss
|
||||
{
|
||||
public class PumpCfg : ComponentCfgBase, IChildComponentCfg, IRouteBasedDrawingItem, IDrawingItemWithSetpoint
|
||||
{
|
||||
public static XmlSerializer Serializer = XmlSerializer.FromTypes(new[] { typeof(PumpCfg) })[0];
|
||||
public override XmlSerializer GetSerializer() { return Serializer; }
|
||||
|
||||
public IComponentCfgCtrl GetControl(IList<Config.Entities.Component> cmpntEntities) { return new PumpCfgCtrl(); }
|
||||
|
||||
///
|
||||
/// Serialized parameters
|
||||
///
|
||||
public int BitNr { get; set; }
|
||||
public bool Inverted { get; set; } /// When true the pump function is inverted: 0 = on, 1 = off
|
||||
public int Delay; /// Delay of the pump function in [s] (affects the duration of transition sequence steps)
|
||||
public byte ModbusAddress; /// 1..254
|
||||
|
||||
public Shape Shape { get; set; }
|
||||
public int X { get; set; }
|
||||
public int Y { get; set; }
|
||||
public Sz Sz { get; set; }
|
||||
public Orient Orient { get; set; }
|
||||
public bool Flip { get; set; }
|
||||
public int LblX { get; set; }
|
||||
public int LblY { get; set; }
|
||||
public Orient LblOrient { get; set; }
|
||||
public int SetpX { get; set; }
|
||||
public int SetpY { get; set; }
|
||||
public Orient SetpOrient { get; set; }
|
||||
public string SetpFormat { get; set; }
|
||||
public Unit SetpUnit { get; set; }
|
||||
|
||||
[XmlIgnore]
|
||||
public IList<GNode> GNodes { get; set; }
|
||||
[XmlIgnore]
|
||||
public IList<GEdge> EdgesToSet { get; set; }
|
||||
|
||||
/// Private parameterless constructor invoked by all other (public) constructors
|
||||
PumpCfg()
|
||||
{
|
||||
GNodes = new List<GNode>();
|
||||
EdgesToSet = new List<GEdge>();
|
||||
}
|
||||
|
||||
public PumpCfg(IComponentFactory factory)
|
||||
: this()
|
||||
{
|
||||
Shape = Shape.PumpFM;
|
||||
Sz = Sz.M;
|
||||
SetpFormat = "{0:F0} %";
|
||||
SetpUnit = Unit.Pct;
|
||||
|
||||
Name = "P";
|
||||
Factory = factory;
|
||||
ParentName = "Modbus";
|
||||
BitNr = 0;
|
||||
Delay = 1;
|
||||
ModbusAddress = 49;
|
||||
}
|
||||
|
||||
|
||||
|
||||
public string ToString(int i)
|
||||
{
|
||||
return string.Format("name={0} bit={1} delay={2} addr={3} parent={4}",
|
||||
Name,
|
||||
BitNr,
|
||||
Delay,
|
||||
ModbusAddress,
|
||||
(string.IsNullOrEmpty(ParentName) ? "-" : ParentName));
|
||||
}
|
||||
}
|
||||
}
|
||||
150
TBF/Rig/Modbus/PumpFM/Grundfoss/PumpCfgCtrl.cs
Normal file
150
TBF/Rig/Modbus/PumpFM/Grundfoss/PumpCfgCtrl.cs
Normal file
@ -0,0 +1,150 @@
|
||||
///
|
||||
/// Copyright (c) 2020 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
using System.Windows.Forms;
|
||||
using Common;
|
||||
using Config.Entities;
|
||||
using TBF.Rig.Generic;
|
||||
using TBF.UI.Bench.Components;
|
||||
|
||||
namespace TBF.Rig.Modbus.PumpFM.Grundfoss
|
||||
{
|
||||
public partial class PumpCfgCtrl : UserControl, IComponentCfgCtrl
|
||||
{
|
||||
ComponentParametersDlg parent;
|
||||
|
||||
public bool ShowMore { get { return false; } }
|
||||
|
||||
PumpCfg config;
|
||||
public IComponentCfg Config
|
||||
{
|
||||
get { return config as IComponentCfg; }
|
||||
set
|
||||
{
|
||||
config = value as PumpCfg;
|
||||
Redraw();
|
||||
}
|
||||
}
|
||||
|
||||
public PumpCfgCtrl()
|
||||
{
|
||||
InitializeComponent();
|
||||
}
|
||||
|
||||
private void PressureMeterCfgCtrl_Load(object sender, EventArgs e)
|
||||
{
|
||||
parent = ParentForm as ComponentParametersDlg;
|
||||
if (parent == null) return;
|
||||
|
||||
if (parent.CmpntEntities != null)
|
||||
{
|
||||
foreach (var cmpnt in parent.CmpntEntities)
|
||||
{
|
||||
if (TbfComponents.CmpntFactoryFromClassName(cmpnt.ClassName) is Modbus.Common.Factory)
|
||||
{
|
||||
parentNameComboBox.Items.Add(cmpnt.Name);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
for (Unit units = 0; units < Unit.Count; units++)
|
||||
{
|
||||
if (global::Common.Units.IsQuantity(units, Quantity.Error))
|
||||
{
|
||||
unitsComboBox.Items.Add(units.ToString());
|
||||
}
|
||||
}
|
||||
|
||||
Redraw();
|
||||
}
|
||||
|
||||
public void Closing()
|
||||
{
|
||||
}
|
||||
|
||||
void Redraw()
|
||||
{
|
||||
if (config == null) return; /// Control was not loaded, settings were not changed
|
||||
|
||||
componentNameLabel.Text = config.Factory.ClassName;
|
||||
nameTextBox.Text = config.Name;
|
||||
parentNameComboBox.Text = string.IsNullOrEmpty(config.ParentName) ? "---" : config.ParentName;
|
||||
bitPositionTextBox.Text = config.BitNr.ToString();
|
||||
delayTextBox.Text = config.Delay.ToString();
|
||||
modbusAddressTextBox.Text = config.ModbusAddress.ToString();
|
||||
formatTextBox.Text = config.SetpFormat;
|
||||
unitsComboBox.Text = config.SetpUnit.ToString();
|
||||
}
|
||||
|
||||
public void Unlock()
|
||||
{
|
||||
nameTextBox.Enabled = true;
|
||||
parentNameComboBox.Enabled = true;
|
||||
bitPositionTextBox.Enabled = true;
|
||||
delayTextBox.Enabled = true;
|
||||
modbusAddressTextBox.Enabled = true;
|
||||
formatTextBox.Enabled = true;
|
||||
unitsComboBox.Enabled = true;
|
||||
}
|
||||
|
||||
public CfgUpdateFlags VerifyCfg(ref string message)
|
||||
{
|
||||
CfgUpdateFlags flags = CfgUpdateFlags.None;
|
||||
|
||||
int dummy;
|
||||
if (!parentNameComboBox.Items.Contains(parentNameComboBox.Text))
|
||||
{
|
||||
flags |= CfgUpdateFlags.Error;
|
||||
message += Environment.NewLine + "Invalid 'Parent Name'";
|
||||
}
|
||||
if (!int.TryParse(bitPositionTextBox.Text, out dummy) || dummy < 0 || dummy >= 128)
|
||||
{
|
||||
flags |= CfgUpdateFlags.Error;
|
||||
message += Environment.NewLine + "'Bit Position' should be between 0 and 127";
|
||||
}
|
||||
if (!int.TryParse(delayTextBox.Text, out dummy) || dummy < 0 || dummy > 300)
|
||||
{
|
||||
flags |= CfgUpdateFlags.Error;
|
||||
message += Environment.NewLine + "'Delay' is not valid";
|
||||
}
|
||||
if (!int.TryParse(modbusAddressTextBox.Text, out dummy) || dummy < 0 || dummy > 254)
|
||||
{
|
||||
flags |= CfgUpdateFlags.Error;
|
||||
message += Environment.NewLine + "'Modbus Address' should be between 0 and 254";
|
||||
}
|
||||
if (!unitsComboBox.Items.Contains(unitsComboBox.Text))
|
||||
{
|
||||
flags |= CfgUpdateFlags.Error;
|
||||
message += Environment.NewLine + "Invalid 'Units'";
|
||||
}
|
||||
return flags;
|
||||
}
|
||||
|
||||
public CfgUpdateFlags UpdateCfg()
|
||||
{
|
||||
CfgUpdateFlags flags = CfgUpdateFlags.RestartRqrd;
|
||||
|
||||
if (config == null) return CfgUpdateFlags.Error; /// Control was not loaded, settings were not changed
|
||||
|
||||
config.Name = nameTextBox.Text;
|
||||
config.ParentName = parentNameComboBox.Text.Equals("---") ? string.Empty : parentNameComboBox.Text;
|
||||
config.BitNr = int.Parse(bitPositionTextBox.Text);
|
||||
config.Delay = int.Parse(delayTextBox.Text);
|
||||
config.ModbusAddress = (byte)int.Parse(modbusAddressTextBox.Text);
|
||||
|
||||
config.SetpFormat = formatTextBox.Text;
|
||||
config.SetpUnit = global::Common.Unit.None;
|
||||
for (Unit units = 0; units < Unit.Count; units++)
|
||||
{
|
||||
if (unitsComboBox.Text == units.ToString())
|
||||
{
|
||||
config.SetpUnit = units;
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
return flags;
|
||||
}
|
||||
}
|
||||
}
|
||||
226
TBF/Rig/Modbus/PumpFM/Grundfoss/PumpCfgCtrl.designer.cs
generated
Normal file
226
TBF/Rig/Modbus/PumpFM/Grundfoss/PumpCfgCtrl.designer.cs
generated
Normal file
@ -0,0 +1,226 @@
|
||||
///
|
||||
/// Copyright (c) 2020 Sensus Slovensko a.s.
|
||||
///
|
||||
namespace TBF.Rig.Modbus.PumpFM.Grundfoss
|
||||
{
|
||||
partial class PumpCfgCtrl
|
||||
{
|
||||
/// <summary>
|
||||
/// Required designer variable.
|
||||
/// </summary>
|
||||
private System.ComponentModel.IContainer components = null;
|
||||
|
||||
/// <summary>
|
||||
/// Clean up any resources being used.
|
||||
/// </summary>
|
||||
/// <param name="disposing">true if managed resources should be disposed; otherwise, false.</param>
|
||||
protected override void Dispose(bool disposing)
|
||||
{
|
||||
if (disposing && (components != null))
|
||||
{
|
||||
components.Dispose();
|
||||
}
|
||||
base.Dispose(disposing);
|
||||
}
|
||||
|
||||
#region Component Designer generated code
|
||||
|
||||
/// <summary>
|
||||
/// Required method for Designer support - do not modify
|
||||
/// the contents of this method with the code editor.
|
||||
/// </summary>
|
||||
private void InitializeComponent()
|
||||
{
|
||||
this.parentNameLabel = new System.Windows.Forms.Label();
|
||||
this.nameTextBox = new System.Windows.Forms.TextBox();
|
||||
this.nameLabel = new System.Windows.Forms.Label();
|
||||
this.componentNameLabel = new System.Windows.Forms.Label();
|
||||
this.modbusAddressLabel = new System.Windows.Forms.Label();
|
||||
this.modbusAddressTextBox = new System.Windows.Forms.TextBox();
|
||||
this.parentNameComboBox = new System.Windows.Forms.ComboBox();
|
||||
this.bitPositionTextBox = new System.Windows.Forms.TextBox();
|
||||
this.bitPositionLabel = new System.Windows.Forms.Label();
|
||||
this.delayTextBox = new System.Windows.Forms.TextBox();
|
||||
this.delayLabel = new System.Windows.Forms.Label();
|
||||
this.unitsComboBox = new System.Windows.Forms.ComboBox();
|
||||
this.unitsLabel = new System.Windows.Forms.Label();
|
||||
this.formatTextBox = new System.Windows.Forms.TextBox();
|
||||
this.formatLabel = new System.Windows.Forms.Label();
|
||||
this.SuspendLayout();
|
||||
//
|
||||
// parentNameLabel
|
||||
//
|
||||
this.parentNameLabel.AutoSize = true;
|
||||
this.parentNameLabel.Location = new System.Drawing.Point(36, 81);
|
||||
this.parentNameLabel.Name = "parentNameLabel";
|
||||
this.parentNameLabel.Size = new System.Drawing.Size(69, 13);
|
||||
this.parentNameLabel.TabIndex = 3;
|
||||
this.parentNameLabel.Text = "Parent Name";
|
||||
//
|
||||
// nameTextBox
|
||||
//
|
||||
this.nameTextBox.Enabled = false;
|
||||
this.nameTextBox.Location = new System.Drawing.Point(146, 52);
|
||||
this.nameTextBox.Name = "nameTextBox";
|
||||
this.nameTextBox.Size = new System.Drawing.Size(130, 20);
|
||||
this.nameTextBox.TabIndex = 2;
|
||||
//
|
||||
// nameLabel
|
||||
//
|
||||
this.nameLabel.AutoSize = true;
|
||||
this.nameLabel.Location = new System.Drawing.Point(36, 55);
|
||||
this.nameLabel.Name = "nameLabel";
|
||||
this.nameLabel.Size = new System.Drawing.Size(35, 13);
|
||||
this.nameLabel.TabIndex = 1;
|
||||
this.nameLabel.Text = "Name";
|
||||
//
|
||||
// componentNameLabel
|
||||
//
|
||||
this.componentNameLabel.AutoSize = true;
|
||||
this.componentNameLabel.Location = new System.Drawing.Point(143, 28);
|
||||
this.componentNameLabel.Name = "componentNameLabel";
|
||||
this.componentNameLabel.Size = new System.Drawing.Size(83, 13);
|
||||
this.componentNameLabel.TabIndex = 0;
|
||||
this.componentNameLabel.Text = "ComonentName";
|
||||
//
|
||||
// modbusAddressLabel
|
||||
//
|
||||
this.modbusAddressLabel.AutoSize = true;
|
||||
this.modbusAddressLabel.Location = new System.Drawing.Point(36, 157);
|
||||
this.modbusAddressLabel.Name = "modbusAddressLabel";
|
||||
this.modbusAddressLabel.Size = new System.Drawing.Size(86, 13);
|
||||
this.modbusAddressLabel.TabIndex = 7;
|
||||
this.modbusAddressLabel.Text = "Modbus Address";
|
||||
//
|
||||
// modbusAddressTextBox
|
||||
//
|
||||
this.modbusAddressTextBox.Enabled = false;
|
||||
this.modbusAddressTextBox.Location = new System.Drawing.Point(146, 154);
|
||||
this.modbusAddressTextBox.Name = "modbusAddressTextBox";
|
||||
this.modbusAddressTextBox.Size = new System.Drawing.Size(46, 20);
|
||||
this.modbusAddressTextBox.TabIndex = 8;
|
||||
//
|
||||
// parentNameComboBox
|
||||
//
|
||||
this.parentNameComboBox.Enabled = false;
|
||||
this.parentNameComboBox.FormattingEnabled = true;
|
||||
this.parentNameComboBox.Location = new System.Drawing.Point(146, 78);
|
||||
this.parentNameComboBox.Name = "parentNameComboBox";
|
||||
this.parentNameComboBox.Size = new System.Drawing.Size(130, 21);
|
||||
this.parentNameComboBox.TabIndex = 4;
|
||||
//
|
||||
// bitPositionTextBox
|
||||
//
|
||||
this.bitPositionTextBox.Enabled = false;
|
||||
this.bitPositionTextBox.Location = new System.Drawing.Point(146, 104);
|
||||
this.bitPositionTextBox.Name = "bitPositionTextBox";
|
||||
this.bitPositionTextBox.Size = new System.Drawing.Size(46, 20);
|
||||
this.bitPositionTextBox.TabIndex = 22;
|
||||
//
|
||||
// bitPositionLabel
|
||||
//
|
||||
this.bitPositionLabel.AutoSize = true;
|
||||
this.bitPositionLabel.Location = new System.Drawing.Point(36, 107);
|
||||
this.bitPositionLabel.Name = "bitPositionLabel";
|
||||
this.bitPositionLabel.Size = new System.Drawing.Size(89, 13);
|
||||
this.bitPositionLabel.TabIndex = 21;
|
||||
this.bitPositionLabel.Text = "Valve Bit Position";
|
||||
//
|
||||
// delayTextBox
|
||||
//
|
||||
this.delayTextBox.Enabled = false;
|
||||
this.delayTextBox.Location = new System.Drawing.Point(146, 129);
|
||||
this.delayTextBox.Name = "delayTextBox";
|
||||
this.delayTextBox.Size = new System.Drawing.Size(46, 20);
|
||||
this.delayTextBox.TabIndex = 24;
|
||||
//
|
||||
// delayLabel
|
||||
//
|
||||
this.delayLabel.AutoSize = true;
|
||||
this.delayLabel.Location = new System.Drawing.Point(35, 131);
|
||||
this.delayLabel.Name = "delayLabel";
|
||||
this.delayLabel.Size = new System.Drawing.Size(45, 13);
|
||||
this.delayLabel.TabIndex = 23;
|
||||
this.delayLabel.Text = "Delay[s]";
|
||||
//
|
||||
// unitsComboBox
|
||||
//
|
||||
this.unitsComboBox.Enabled = false;
|
||||
this.unitsComboBox.FormattingEnabled = true;
|
||||
this.unitsComboBox.Location = new System.Drawing.Point(146, 206);
|
||||
this.unitsComboBox.Name = "unitsComboBox";
|
||||
this.unitsComboBox.Size = new System.Drawing.Size(80, 21);
|
||||
this.unitsComboBox.TabIndex = 28;
|
||||
//
|
||||
// unitsLabel
|
||||
//
|
||||
this.unitsLabel.AutoSize = true;
|
||||
this.unitsLabel.Location = new System.Drawing.Point(36, 209);
|
||||
this.unitsLabel.Name = "unitsLabel";
|
||||
this.unitsLabel.Size = new System.Drawing.Size(71, 13);
|
||||
this.unitsLabel.TabIndex = 27;
|
||||
this.unitsLabel.Text = "Setpoint units";
|
||||
//
|
||||
// formatTextBox
|
||||
//
|
||||
this.formatTextBox.Enabled = false;
|
||||
this.formatTextBox.Location = new System.Drawing.Point(146, 180);
|
||||
this.formatTextBox.Name = "formatTextBox";
|
||||
this.formatTextBox.Size = new System.Drawing.Size(130, 20);
|
||||
this.formatTextBox.TabIndex = 26;
|
||||
//
|
||||
// formatLabel
|
||||
//
|
||||
this.formatLabel.AutoSize = true;
|
||||
this.formatLabel.Location = new System.Drawing.Point(36, 183);
|
||||
this.formatLabel.Name = "formatLabel";
|
||||
this.formatLabel.Size = new System.Drawing.Size(78, 13);
|
||||
this.formatLabel.TabIndex = 25;
|
||||
this.formatLabel.Text = "Setpoint format";
|
||||
//
|
||||
// PumpCfgCtrl
|
||||
//
|
||||
this.AutoScaleDimensions = new System.Drawing.SizeF(6F, 13F);
|
||||
this.AutoScaleMode = System.Windows.Forms.AutoScaleMode.Font;
|
||||
this.Controls.Add(this.unitsComboBox);
|
||||
this.Controls.Add(this.unitsLabel);
|
||||
this.Controls.Add(this.formatTextBox);
|
||||
this.Controls.Add(this.formatLabel);
|
||||
this.Controls.Add(this.delayTextBox);
|
||||
this.Controls.Add(this.delayLabel);
|
||||
this.Controls.Add(this.bitPositionTextBox);
|
||||
this.Controls.Add(this.bitPositionLabel);
|
||||
this.Controls.Add(this.parentNameComboBox);
|
||||
this.Controls.Add(this.modbusAddressTextBox);
|
||||
this.Controls.Add(this.modbusAddressLabel);
|
||||
this.Controls.Add(this.parentNameLabel);
|
||||
this.Controls.Add(this.nameTextBox);
|
||||
this.Controls.Add(this.nameLabel);
|
||||
this.Controls.Add(this.componentNameLabel);
|
||||
this.Name = "PumpCfgCtrl";
|
||||
this.Size = new System.Drawing.Size(400, 250);
|
||||
this.Load += new System.EventHandler(this.PressureMeterCfgCtrl_Load);
|
||||
this.ResumeLayout(false);
|
||||
this.PerformLayout();
|
||||
|
||||
}
|
||||
|
||||
#endregion
|
||||
|
||||
private System.Windows.Forms.Label parentNameLabel;
|
||||
private System.Windows.Forms.TextBox nameTextBox;
|
||||
private System.Windows.Forms.Label nameLabel;
|
||||
private System.Windows.Forms.Label componentNameLabel;
|
||||
private System.Windows.Forms.Label modbusAddressLabel;
|
||||
private System.Windows.Forms.TextBox modbusAddressTextBox;
|
||||
private System.Windows.Forms.ComboBox parentNameComboBox;
|
||||
private System.Windows.Forms.TextBox bitPositionTextBox;
|
||||
private System.Windows.Forms.Label bitPositionLabel;
|
||||
private System.Windows.Forms.TextBox delayTextBox;
|
||||
private System.Windows.Forms.Label delayLabel;
|
||||
private System.Windows.Forms.ComboBox unitsComboBox;
|
||||
private System.Windows.Forms.Label unitsLabel;
|
||||
private System.Windows.Forms.TextBox formatTextBox;
|
||||
private System.Windows.Forms.Label formatLabel;
|
||||
}
|
||||
}
|
||||
120
TBF/Rig/Modbus/PumpFM/Grundfoss/PumpCfgCtrl.resx
Normal file
120
TBF/Rig/Modbus/PumpFM/Grundfoss/PumpCfgCtrl.resx
Normal file
@ -0,0 +1,120 @@
|
||||
<?xml version="1.0" encoding="utf-8"?>
|
||||
<root>
|
||||
<!--
|
||||
Microsoft ResX Schema
|
||||
|
||||
Version 2.0
|
||||
|
||||
The primary goals of this format is to allow a simple XML format
|
||||
that is mostly human readable. The generation and parsing of the
|
||||
various data types are done through the TypeConverter classes
|
||||
associated with the data types.
|
||||
|
||||
Example:
|
||||
|
||||
... ado.net/XML headers & schema ...
|
||||
<resheader name="resmimetype">text/microsoft-resx</resheader>
|
||||
<resheader name="version">2.0</resheader>
|
||||
<resheader name="reader">System.Resources.ResXResourceReader, System.Windows.Forms, ...</resheader>
|
||||
<resheader name="writer">System.Resources.ResXResourceWriter, System.Windows.Forms, ...</resheader>
|
||||
<data name="Name1"><value>this is my long string</value><comment>this is a comment</comment></data>
|
||||
<data name="Color1" type="System.Drawing.Color, System.Drawing">Blue</data>
|
||||
<data name="Bitmap1" mimetype="application/x-microsoft.net.object.binary.base64">
|
||||
<value>[base64 mime encoded serialized .NET Framework object]</value>
|
||||
</data>
|
||||
<data name="Icon1" type="System.Drawing.Icon, System.Drawing" mimetype="application/x-microsoft.net.object.bytearray.base64">
|
||||
<value>[base64 mime encoded string representing a byte array form of the .NET Framework object]</value>
|
||||
<comment>This is a comment</comment>
|
||||
</data>
|
||||
|
||||
There are any number of "resheader" rows that contain simple
|
||||
name/value pairs.
|
||||
|
||||
Each data row contains a name, and value. The row also contains a
|
||||
type or mimetype. Type corresponds to a .NET class that support
|
||||
text/value conversion through the TypeConverter architecture.
|
||||
Classes that don't support this are serialized and stored with the
|
||||
mimetype set.
|
||||
|
||||
The mimetype is used for serialized objects, and tells the
|
||||
ResXResourceReader how to depersist the object. This is currently not
|
||||
extensible. For a given mimetype the value must be set accordingly:
|
||||
|
||||
Note - application/x-microsoft.net.object.binary.base64 is the format
|
||||
that the ResXResourceWriter will generate, however the reader can
|
||||
read any of the formats listed below.
|
||||
|
||||
mimetype: application/x-microsoft.net.object.binary.base64
|
||||
value : The object must be serialized with
|
||||
: System.Runtime.Serialization.Formatters.Binary.BinaryFormatter
|
||||
: and then encoded with base64 encoding.
|
||||
|
||||
mimetype: application/x-microsoft.net.object.soap.base64
|
||||
value : The object must be serialized with
|
||||
: System.Runtime.Serialization.Formatters.Soap.SoapFormatter
|
||||
: and then encoded with base64 encoding.
|
||||
|
||||
mimetype: application/x-microsoft.net.object.bytearray.base64
|
||||
value : The object must be serialized into a byte array
|
||||
: using a System.ComponentModel.TypeConverter
|
||||
: and then encoded with base64 encoding.
|
||||
-->
|
||||
<xsd:schema id="root" xmlns="" xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns:msdata="urn:schemas-microsoft-com:xml-msdata">
|
||||
<xsd:import namespace="http://www.w3.org/XML/1998/namespace" />
|
||||
<xsd:element name="root" msdata:IsDataSet="true">
|
||||
<xsd:complexType>
|
||||
<xsd:choice maxOccurs="unbounded">
|
||||
<xsd:element name="metadata">
|
||||
<xsd:complexType>
|
||||
<xsd:sequence>
|
||||
<xsd:element name="value" type="xsd:string" minOccurs="0" />
|
||||
</xsd:sequence>
|
||||
<xsd:attribute name="name" use="required" type="xsd:string" />
|
||||
<xsd:attribute name="type" type="xsd:string" />
|
||||
<xsd:attribute name="mimetype" type="xsd:string" />
|
||||
<xsd:attribute ref="xml:space" />
|
||||
</xsd:complexType>
|
||||
</xsd:element>
|
||||
<xsd:element name="assembly">
|
||||
<xsd:complexType>
|
||||
<xsd:attribute name="alias" type="xsd:string" />
|
||||
<xsd:attribute name="name" type="xsd:string" />
|
||||
</xsd:complexType>
|
||||
</xsd:element>
|
||||
<xsd:element name="data">
|
||||
<xsd:complexType>
|
||||
<xsd:sequence>
|
||||
<xsd:element name="value" type="xsd:string" minOccurs="0" msdata:Ordinal="1" />
|
||||
<xsd:element name="comment" type="xsd:string" minOccurs="0" msdata:Ordinal="2" />
|
||||
</xsd:sequence>
|
||||
<xsd:attribute name="name" type="xsd:string" use="required" msdata:Ordinal="1" />
|
||||
<xsd:attribute name="type" type="xsd:string" msdata:Ordinal="3" />
|
||||
<xsd:attribute name="mimetype" type="xsd:string" msdata:Ordinal="4" />
|
||||
<xsd:attribute ref="xml:space" />
|
||||
</xsd:complexType>
|
||||
</xsd:element>
|
||||
<xsd:element name="resheader">
|
||||
<xsd:complexType>
|
||||
<xsd:sequence>
|
||||
<xsd:element name="value" type="xsd:string" minOccurs="0" msdata:Ordinal="1" />
|
||||
</xsd:sequence>
|
||||
<xsd:attribute name="name" type="xsd:string" use="required" />
|
||||
</xsd:complexType>
|
||||
</xsd:element>
|
||||
</xsd:choice>
|
||||
</xsd:complexType>
|
||||
</xsd:element>
|
||||
</xsd:schema>
|
||||
<resheader name="resmimetype">
|
||||
<value>text/microsoft-resx</value>
|
||||
</resheader>
|
||||
<resheader name="version">
|
||||
<value>2.0</value>
|
||||
</resheader>
|
||||
<resheader name="reader">
|
||||
<value>System.Resources.ResXResourceReader, System.Windows.Forms, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089</value>
|
||||
</resheader>
|
||||
<resheader name="writer">
|
||||
<value>System.Resources.ResXResourceWriter, System.Windows.Forms, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089</value>
|
||||
</resheader>
|
||||
</root>
|
||||
@ -70,6 +70,7 @@ namespace TBF.Rig
|
||||
new Modbus.PressureMeter.Meret.Factory(), /// Meret pressure meter connected via a modbus on a PC
|
||||
new Modbus.Meret.AdjustableScale.Factory(), /// Adjustable meter connected via a modbus on a PC
|
||||
new Modbus.PumpFM.DanfossVLT.Factory(), /// Pump controlled by Danfoss VLT connected via Modbus
|
||||
new Modbus.PumpFM.Grundfoss.Factory(), /// Pump controlled by Grundfoss VLT connected via Modbus
|
||||
new Modbus.QuidoRS.Factory(), /// Modbus.QuidoRS
|
||||
new Modbus.TankSelector.Factory(), /// Modbus.TankSelector
|
||||
new Modbus.TempControl.Easytherm.Factory(),
|
||||
|
||||
@ -765,6 +765,15 @@
|
||||
<Compile Include="Rig\Modbus\PumpFM\DanfossVLT\PumpCfgCtrl.designer.cs">
|
||||
<DependentUpon>PumpCfgCtrl.cs</DependentUpon>
|
||||
</Compile>
|
||||
<Compile Include="Rig\Modbus\PumpFM\Grundfoss\Factory.cs" />
|
||||
<Compile Include="Rig\Modbus\PumpFM\Grundfoss\Pump.cs" />
|
||||
<Compile Include="Rig\Modbus\PumpFM\Grundfoss\PumpCfg.cs" />
|
||||
<Compile Include="Rig\Modbus\PumpFM\Grundfoss\PumpCfgCtrl.cs">
|
||||
<SubType>UserControl</SubType>
|
||||
</Compile>
|
||||
<Compile Include="Rig\Modbus\PumpFM\Grundfoss\PumpCfgCtrl.designer.cs">
|
||||
<DependentUpon>PumpCfgCtrl.cs</DependentUpon>
|
||||
</Compile>
|
||||
<Compile Include="Rig\Modbus\QuidoRS\ConfirmationForm.cs">
|
||||
<SubType>Form</SubType>
|
||||
</Compile>
|
||||
@ -3212,6 +3221,9 @@
|
||||
<EmbeddedResource Include="Rig\Modbus\PumpFM\DanfossVLT\PumpCfgCtrl.resx">
|
||||
<DependentUpon>PumpCfgCtrl.cs</DependentUpon>
|
||||
</EmbeddedResource>
|
||||
<EmbeddedResource Include="Rig\Modbus\PumpFM\Grundfoss\PumpCfgCtrl.resx">
|
||||
<DependentUpon>PumpCfgCtrl.cs</DependentUpon>
|
||||
</EmbeddedResource>
|
||||
<EmbeddedResource Include="Rig\Modbus\QuidoRS\ConfirmationForm.resx">
|
||||
<DependentUpon>ConfirmationForm.cs</DependentUpon>
|
||||
</EmbeddedResource>
|
||||
|
||||
@ -370,6 +370,7 @@ namespace TBF.UI.Process
|
||||
/// water
|
||||
Rig.Various.Drawing.Tank.Configuration tankCfg; /// |
|
||||
Rig.Modbus.PumpFM.DanfossVLT.PumpCfg pumpCfg; /// | setpoint, route based (initially bit nr. = 124)
|
||||
//Rig.Modbus.PumpFM.Grundfoss.PumpCfg pump2Cfg; /// | setpoint, route based (initially bit nr. = 124)//
|
||||
Rig.Modbus.TempMeter.Groch.TempMeterCfg tempInCfg; /// | measured value
|
||||
Rig.Modbus.PressureMeter.Meret.PressureMeterCfg pressUpCfg; /// | measured value
|
||||
Rig.Modbus.Meret.AdjustableScale.AdjustableMeterCfg electricUpCfg; /// | measured value
|
||||
@ -438,6 +439,31 @@ namespace TBF.UI.Process
|
||||
Inverted = false,
|
||||
});
|
||||
|
||||
/*/// Pump
|
||||
pumpSetpIx = setpIx++;
|
||||
processDrawingCtrl.AddItem(
|
||||
pump2Cfg = new Rig.Modbus.PumpFM.Grundfoss.PumpCfg(new Rig.Modbus.PumpFM.Grundfoss.Factory())
|
||||
{
|
||||
Id = pumpId = id++,
|
||||
Name = "P Grundfoss",
|
||||
X = 450,
|
||||
Y = 480,
|
||||
Shape = Shape.PumpFM,
|
||||
Sz = Sz.L,
|
||||
Orient = Orient.L,
|
||||
Flip = false,
|
||||
LblX = 0,
|
||||
LblY = -46,
|
||||
LblOrient = Orient.R,
|
||||
SetpX = 0,
|
||||
SetpY = -24,
|
||||
SetpOrient = Orient.R,
|
||||
SetpFormat = "{0:F0} %",
|
||||
SetpUnit = Unit.Pct,
|
||||
BitNr = DfltPumpBitNr,
|
||||
Inverted = false,
|
||||
});*/
|
||||
|
||||
/// Junctions
|
||||
processDrawingCtrl.AddItem(new Configuration("J1", new Factory()) { Id=j1=id++, Shape=Shape.Junction, X=50, Y=490, Sz=Sz.L, });
|
||||
processDrawingCtrl.AddItem(new Configuration("J2", new Factory()) { Id=j2=id++, Shape=Shape.Junction, X=50, Y=370, Sz=Sz.L, });
|
||||
@ -856,6 +882,12 @@ namespace TBF.UI.Process
|
||||
pumpCfg.BitNr = (args.FeedingPath.Pump.Cfg as Rig.Modbus.PumpFM.DanfossVLT.PumpCfg).BitNr;
|
||||
pumpCfg.Inverted = (args.FeedingPath.Pump.Cfg as Rig.Modbus.PumpFM.DanfossVLT.PumpCfg).Inverted;
|
||||
}
|
||||
else if (args.FeedingPath != null && args.FeedingPath.Pump != null &&
|
||||
args.FeedingPath.Pump.Cfg is Rig.Modbus.PumpFM.Grundfoss.PumpCfg)
|
||||
{
|
||||
pumpCfg.BitNr = (args.FeedingPath.Pump.Cfg as Rig.Modbus.PumpFM.Grundfoss.PumpCfg).BitNr;
|
||||
pumpCfg.Inverted = (args.FeedingPath.Pump.Cfg as Rig.Modbus.PumpFM.Grundfoss.PumpCfg).Inverted;
|
||||
}
|
||||
else
|
||||
{
|
||||
pumpCfg.BitNr = DfltPumpBitNr;
|
||||
|
||||
Loading…
Reference in New Issue
Block a user