TimeFlow2Mass used in CombinedMeters flying start method. Code cleanup.
This commit is contained in:
parent
e2dfa05233
commit
1e0e3efd5a
@ -30,9 +30,6 @@ namespace TBF.BenchControl.TestMethods.CombinedMeters
|
||||
{
|
||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||
|
||||
/// Specific for combined meters
|
||||
int[] lastWMPulses = new int[Program.WMsCount];
|
||||
|
||||
IList<Event> e = new List<Event>(); /// Events from currently running operations
|
||||
Event retVal = Event.Done;
|
||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||
@ -144,7 +141,9 @@ namespace TBF.BenchControl.TestMethods.CombinedMeters
|
||||
|
||||
set_flow:
|
||||
|
||||
//--------------------------------
|
||||
//------------------------------------------------
|
||||
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
||||
//------------------------------------------------
|
||||
State.Create("CombinedMeters : Setting the flow")
|
||||
.AddOperation(checkUiOp)
|
||||
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, refFlow, 600)) /// timeout = 10 min.
|
||||
@ -181,6 +180,31 @@ namespace TBF.BenchControl.TestMethods.CombinedMeters
|
||||
if (cameraRoi != null) measureOperations.Add(cameraRoi.MeasureOp());
|
||||
}
|
||||
|
||||
State.Create("CombinedMeters : Waiting before 1st mass measurement")
|
||||
.AddOperation(checkUiOp)
|
||||
.AddOperation(benchPath.TempIn.ReadTempOp(ref tempIn))
|
||||
.AddOperation(benchPath.TempOut.ReadTempOp(ref tempOut))
|
||||
.AddOperation(outPath.TempDiv.ReadTempOp(ref tempDiv))
|
||||
.AddOperation(benchPath.PressIn.ReadPressureOp(ref pressIn))
|
||||
.AddOperation(benchPath.PressOut.ReadPressureOp(ref pressOut))
|
||||
.AddOperation((StateMachine.Ambient != null)
|
||||
? StateMachine.Ambient.ReadAmbientOp(airTemperature, airPressure, airHumidity) : null)
|
||||
.AddOperation(outPath.Balance.ReadMassOp(ref mass))
|
||||
.AddOperation(cBrd.UpdateTankWeightOp())
|
||||
.AddOperation(processDataLoggingOp)
|
||||
.AddOperation(new Operations.TimerOp(test.TimeFlow2Mass))
|
||||
.EnterState();
|
||||
do
|
||||
{
|
||||
e = StateMachine.WaitRunDevsRunOps();
|
||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||
if (e.Contains(Event.UiCmdStop)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||
}
|
||||
while (!e.Contains(Event.TimerExpired));
|
||||
|
||||
|
||||
LogProcessHeader(processDataLogger, "Start mass");
|
||||
|
||||
//------------------------------------------------
|
||||
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
||||
//------------------------------------------------
|
||||
@ -453,7 +477,7 @@ namespace TBF.BenchControl.TestMethods.CombinedMeters
|
||||
/// Quit this sequence ///
|
||||
///----------------------///
|
||||
|
||||
State.Create("FlyingStartCollectionMethod : Stopping diverter, gate, etc.")
|
||||
State.Create("CombinedMeters : Stopping diverter, gate, etc.")
|
||||
.AddOperation(checkUiOp)
|
||||
.AddOperation(cBrd.StopPreviousOp())
|
||||
.EnterState();
|
||||
|
||||
@ -239,11 +239,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
||||
|
||||
for (int i = 0; i < Program.WMsCount; i++)
|
||||
{
|
||||
BenchControl.Elde.FixedStartRegisterReader.RegisterReader registerReader =
|
||||
sensPath.RegisterReaders[i] as BenchControl.Elde.FixedStartRegisterReader.RegisterReader;
|
||||
|
||||
tstRslt.Meters[i].VolumeStart = dataEntryCmpnt.WMStartState(i); /// Units: 1 liter
|
||||
|
||||
///-----
|
||||
BenchControl.Elde.FixedStartRegisterReader.RegisterReader registerReader =
|
||||
sensPath.RegisterReaders[i] as BenchControl.Elde.FixedStartRegisterReader.RegisterReader;
|
||||
|
||||
if (registerReader != null) registerReader.BeginWMState = dataEntryCmpnt.WMStartState(i);
|
||||
}
|
||||
}
|
||||
@ -476,11 +477,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
||||
|
||||
for (int i = 0; i < Program.WMsCount; i++)
|
||||
{
|
||||
BenchControl.Elde.FixedStartRegisterReader.RegisterReader registerReader =
|
||||
sensPath.RegisterReaders[i] as BenchControl.Elde.FixedStartRegisterReader.RegisterReader;
|
||||
|
||||
tstRslt.Meters[i].VolumeEnd = dataEntryCmpnt.WMEndState(i);
|
||||
|
||||
///-----
|
||||
BenchControl.Elde.FixedStartRegisterReader.RegisterReader registerReader =
|
||||
sensPath.RegisterReaders[i] as BenchControl.Elde.FixedStartRegisterReader.RegisterReader;
|
||||
|
||||
if (registerReader != null) registerReader.EndWMState = dataEntryCmpnt.WMEndState(i);
|
||||
}
|
||||
}
|
||||
@ -533,11 +535,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
||||
tstRslt.TimeDivEnd3 = 0;
|
||||
tstRslt.TimeDivEnd4 = 0;
|
||||
tstRslt.TimeDivEnd5 = 0;
|
||||
|
||||
for (int i = 0; i < Program.WMsCount; i++)
|
||||
{
|
||||
if ((WaterMeters.Count > i) && !WaterMeters[i].Disabled)
|
||||
if ((i < WaterMeters.Count) && !WaterMeters[i].Disabled)
|
||||
{
|
||||
tstRslt.Meters[i].SerialNr = (WaterMeters.Count > i) ? WaterMeters[i].SerialNr : string.Empty;
|
||||
tstRslt.Meters[i].SerialNr = (i < WaterMeters.Count) ? WaterMeters[i].SerialNr : string.Empty;
|
||||
tstRslt.Meters[i].VolumeMeter = tstRslt.Meters[i].VolumeEnd - tstRslt.Meters[i].VolumeStart;
|
||||
tstRslt.Meters[i].VolumeRef = tstRslt.VolumeCTV; /// liter
|
||||
tstRslt.Meters[i].PulsesMeter = 0;
|
||||
|
||||