1102 lines
60 KiB
XML
1102 lines
60 KiB
XML
|
|
<?xml version="1.0"?>
|
|||
|
|
<doc>
|
|||
|
|
<assembly>
|
|||
|
|
<name>Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore</name>
|
|||
|
|
</assembly>
|
|||
|
|
<members>
|
|||
|
|
<member name="T:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Consts.LedMode">
|
|||
|
|
<summary>
|
|||
|
|
Streaming modes that supported by genesis meter.
|
|||
|
|
Set meter to this Streaming mode means that , the meter pushes mode-specific record to port without any responses
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Consts.LedMode.FlowTestAndCalibData">
|
|||
|
|
<summary>
|
|||
|
|
Test mode with raw record to log. Should give one <see cref="T:Xylem.Common.Hardware.WaterMeter.Genesis.DataPackages.MeasurementRecords.FlowTestRecord"/>
|
|||
|
|
3 times <see cref="T:Xylem.Common.Hardware.WaterMeter.Genesis.DataPackages.MeasurementRecords.CalibrationRecord"/> and repeat this till led mode is switch
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Consts.LedMode.FlowTestData">
|
|||
|
|
<summary>
|
|||
|
|
Test mode should give <see cref="T:Xylem.Common.Hardware.WaterMeter.Genesis.DataPackages.MeasurementRecords.FlowTestRecord"/> out
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Consts.LedMode.CalibData">
|
|||
|
|
<summary>
|
|||
|
|
Calibration mode should give <see cref="T:Xylem.Common.Hardware.WaterMeter.Genesis.DataPackages.MeasurementRecords.CalibrationRecord"/> out
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Consts.LedMode.Off">
|
|||
|
|
<summary>
|
|||
|
|
Deactivate streaming
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Consts.LedMode.Unknown">
|
|||
|
|
<summary>
|
|||
|
|
not set or an new not supported Streaming mode
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="T:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter">
|
|||
|
|
<inheritdoc cref="T:Xylem.Common.Hardware.WaterMeter.WaterMeterCore.IMeter" />
|
|||
|
|
<summary>
|
|||
|
|
Genesis meter, main class for all action that occurs on production life of meter
|
|||
|
|
one meter always have a linked port for UART communication and one for LED (even if you don't need them)
|
|||
|
|
it´s has to be open for vb6 COM so don't use any record types or objects that vb6 didn't understand or
|
|||
|
|
interprets differently than dotNet
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.#ctor">
|
|||
|
|
<summary> Default constructor. </summary>
|
|||
|
|
|
|||
|
|
<remarks> R.Drabesch, 2018-Feb-16. </remarks>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.TransmitProtocol">
|
|||
|
|
<summary>
|
|||
|
|
Transmit protocol access for underlie objects to change response timeout
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.#ctor(System.Int32,System.Nullable{Xylem.Common.Hardware.WaterMeter.Genesis.GenesisConfig.PortConfig},System.Nullable{Xylem.Common.Hardware.WaterMeter.Genesis.GenesisConfig.PortConfig},System.Boolean,System.String)">
|
|||
|
|
<summary>
|
|||
|
|
</summary>
|
|||
|
|
<param name="slot">Slot number for test-bench </param>
|
|||
|
|
<param name="requestPort"><see cref="T:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisConfig.PortConfig" /> for request Port</param>
|
|||
|
|
<param name="streamingPort"><see cref="T:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisConfig.PortConfig" /> for streaming Port</param>
|
|||
|
|
<param name="ignoreCorruptedData">don´t send CRC error or telegrams with error flag to caller</param>
|
|||
|
|
<param name="password">
|
|||
|
|
If you have a password for highest access level you need, if you don't want to access the meter
|
|||
|
|
(just read led record) than you can leave it null
|
|||
|
|
</param>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.LoginLvl">
|
|||
|
|
<summary>
|
|||
|
|
Keep up the highest access level for all function in <see cref="T:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter" /> where used
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.LogoutLvl">
|
|||
|
|
<summary>
|
|||
|
|
Logout with level 0
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.SerialNumber">
|
|||
|
|
<inheritdoc />
|
|||
|
|
<summary>
|
|||
|
|
Property is redundant because is also stored in
|
|||
|
|
<see cref="T:Xylem.Sensus.WaterMeter.Genesis.Logic.Domain.Genesis.DataPackages.MeterRegister" /> but never less is
|
|||
|
|
is the identification of the meter it has a separate Property
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.Slot">
|
|||
|
|
<inheritdoc />
|
|||
|
|
<summary>
|
|||
|
|
Save Slot Number (position at test-bench) for logging purposes
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.PcbId">
|
|||
|
|
<summary>
|
|||
|
|
Represent <see cref="F:Xylem.Common.Hardware.WaterMeter.Genesis.Registers.Register.Configexchange.PCBSerialNumber" />
|
|||
|
|
proposed for login
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.IntermediateUpdateTimeS">
|
|||
|
|
<inheritdoc />
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter._password">
|
|||
|
|
<summary>
|
|||
|
|
Add on ctor a password and it will be used for login in if no other password is set
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter._autoLogon">
|
|||
|
|
<summary>
|
|||
|
|
default false only enabled by <see cref="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.EnableAutoLogon"/>
|
|||
|
|
when it is true, the meter will enforce the login when session is gone or access is denied
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter._enableRawDataLogging">
|
|||
|
|
<summary>
|
|||
|
|
Enable raw record logging, if set every incoming package will be logged
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.IsDevelopmentUsage">
|
|||
|
|
<summary>
|
|||
|
|
Enable use of registers that are not valid (last version not match the current app)
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter._configRegister">
|
|||
|
|
<summary>
|
|||
|
|
All parameter store in this Genesis is up in here
|
|||
|
|
if you want to read them from meter use <see cref="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.ReadRegister(System.String,System.Nullable{System.Int32},System.UInt16)" />
|
|||
|
|
if you want to set them to meter use <see cref="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.WriteRegister``1(System.String,``0,System.Boolean,System.Boolean,System.UInt16)" />
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter._configApplications">
|
|||
|
|
<summary>
|
|||
|
|
All applications defined by configuration.json
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.RequestPort">
|
|||
|
|
<summary>
|
|||
|
|
request port assignment/info
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.RequestProtocol">
|
|||
|
|
<summary>
|
|||
|
|
request protocol assignment/info
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.StreamingPort">
|
|||
|
|
<summary>
|
|||
|
|
streaming port assignment/info
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.StreamingProtocol">
|
|||
|
|
<summary>
|
|||
|
|
streaming protocol assignment/info
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.SkipPrepearationForTestBench">
|
|||
|
|
<summary>
|
|||
|
|
to reduce the IrdA communication in test bench, preparation will be done once (when SkipPrepearationForTestBench is true)
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="E:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.OnRequestRecordReceived">
|
|||
|
|
<summary>
|
|||
|
|
Response received after request for record
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.SetConfigRegisterDefinitions(System.Collections.Generic.List{Xylem.Common.Hardware.WaterMeter.WaterMeterRegisters.IRegister})">
|
|||
|
|
<inheritdoc />
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.GetConfigRegistersDefinitions">
|
|||
|
|
<summary>
|
|||
|
|
Returns meter registers
|
|||
|
|
</summary>
|
|||
|
|
<returns></returns>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.Xylem#Common#Hardware#WaterMeter#WaterMeterRegisters#IWaterMeterWithRegisters#LoadConfiguration(System.String)">
|
|||
|
|
<inheritdoc />
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter._myProcessStatus">
|
|||
|
|
<summary>
|
|||
|
|
do not use it to set ProcessStatus
|
|||
|
|
if you want to change ProcessStatus of this genesis use <see cref="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.ProcessStatus" />
|
|||
|
|
<see cref="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter._myProcessStatus" /> is just store for some routines
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.ProcessStatus">
|
|||
|
|
<inheritdoc />
|
|||
|
|
if state is change
|
|||
|
|
<see cref="E:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.OnProcessStatusChanged" />
|
|||
|
|
will be invoked.
|
|||
|
|
on some states other events will be invoke as well
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter._myErrorState">
|
|||
|
|
<summary>
|
|||
|
|
do not use it to set ErrorStatus
|
|||
|
|
if you want to change ErrorStatus of this genesis use <see cref="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.ErrorStatus" />
|
|||
|
|
<see cref="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter._myErrorState" /> is just store for some routines
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.ErrorStatus">
|
|||
|
|
<inheritdoc />
|
|||
|
|
fires up
|
|||
|
|
<see cref="E:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.OnErrorStatusChanged" />
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.IsLoggedOn">
|
|||
|
|
<summary>
|
|||
|
|
Logged in to device
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.CurrentActionText">
|
|||
|
|
<summary>
|
|||
|
|
Hold the current process name e.g. FlowTest, Preadjustemtn for logging
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.SetupFromConfigFile(System.Int32,System.Boolean)">
|
|||
|
|
<inheritdoc />
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.SetupFromConfigFile(System.Int32,System.Boolean,System.Boolean,System.Boolean)">
|
|||
|
|
<summary>
|
|||
|
|
Setup water meter from configuration file:
|
|||
|
|
-slot,
|
|||
|
|
-streaming protocol,
|
|||
|
|
-streaming port
|
|||
|
|
-request port
|
|||
|
|
</summary>
|
|||
|
|
<param name="slot"></param>
|
|||
|
|
<param name="ignoreCorruptedData"></param>
|
|||
|
|
<param name="useRequest"></param>
|
|||
|
|
<param name="useStreaming"></param>
|
|||
|
|
<exception cref="T:System.ApplicationException"></exception>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.SetupGenesisMeter(System.Int32,System.Nullable{Xylem.Common.Hardware.WaterMeter.Genesis.GenesisConfig.PortConfig},System.Nullable{Xylem.Common.Hardware.WaterMeter.Genesis.GenesisConfig.PortConfig},System.Boolean,System.String)">
|
|||
|
|
<summary>
|
|||
|
|
just internal setup. called on ctor or from vb6 setup function
|
|||
|
|
</summary>
|
|||
|
|
<param name="slot">Slot Number for test-bench </param>
|
|||
|
|
<param name="requestPort"><see cref="T:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisConfig.PortConfig" /> for RFID/UART/IrDA Port</param>
|
|||
|
|
<param name="streamingPort"><see cref="T:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisConfig.PortConfig" /> for LED Port</param>
|
|||
|
|
<param name="ignoreCorruptedData">don´t send CRC error or telegrams with error flag to caller</param>
|
|||
|
|
<param name="password">
|
|||
|
|
If you have a password for highest access level you need, if you don't want to access the meter
|
|||
|
|
(just read led record) than you can leave it nullS
|
|||
|
|
</param>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.ConnectMeter">
|
|||
|
|
<inheritdoc />
|
|||
|
|
<summary>
|
|||
|
|
Start Event listening, has to be called after <see cref="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.SetupGenesisMeter(System.Int32,System.Nullable{Xylem.Common.Hardware.WaterMeter.Genesis.GenesisConfig.PortConfig},System.Nullable{Xylem.Common.Hardware.WaterMeter.Genesis.GenesisConfig.PortConfig},System.Boolean,System.String)" />
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.LinkPortToProtocol(Xylem.Common.Hardware.Interfaces.Ports.PortCore.IPort,Xylem.Common.Hardware.WaterMeter.Genesis.Protocols.ProtocolCore.IProtocol)">
|
|||
|
|
<summary>
|
|||
|
|
Add a port to working queue
|
|||
|
|
</summary>
|
|||
|
|
<param name="port">On <see cref="T:Xylem.Common.Hardware.Interfaces.Ports.PortCore.IPort" /> should one once added in runtime</param>
|
|||
|
|
<param name="protocol"></param>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.SyncStreamingBuffer(Xylem.Common.CommonCore.Consts.SyncMarkRecord)">
|
|||
|
|
<summary>
|
|||
|
|
Synchronization of the record for the streaming interface
|
|||
|
|
</summary>
|
|||
|
|
<param name="markRecord"></param>
|
|||
|
|
<exception cref="T:System.ApplicationException"></exception>
|
|||
|
|
</member>
|
|||
|
|
<member name="E:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.OnCalibCompleted">
|
|||
|
|
<inheritdoc cref="T:Xylem.Common.Hardware.WaterMeter.WaterMeterCore.IMeter" />
|
|||
|
|
</member>
|
|||
|
|
<member name="E:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.OnErrorStatusChanged">
|
|||
|
|
<inheritdoc cref="T:Xylem.Common.Hardware.WaterMeter.WaterMeterCore.IMeter" />
|
|||
|
|
</member>
|
|||
|
|
<member name="E:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.OnProcessStatusChanged">
|
|||
|
|
<inheritdoc cref="T:Xylem.Common.Hardware.WaterMeter.WaterMeterCore.IMeter" />
|
|||
|
|
</member>
|
|||
|
|
<member name="E:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.OnCalibInitCompleted">
|
|||
|
|
<inheritdoc cref="T:Xylem.Common.Hardware.WaterMeter.WaterMeterCore.IMeter" />
|
|||
|
|
</member>
|
|||
|
|
<member name="E:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.OnInitCompleted">
|
|||
|
|
<inheritdoc cref="T:Xylem.Common.Hardware.WaterMeter.WaterMeterCore.IMeter" />
|
|||
|
|
</member>
|
|||
|
|
<member name="E:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.OnMeasurementInitCompleted">
|
|||
|
|
<inheritdoc cref="T:Xylem.Common.Hardware.WaterMeter.WaterMeterCore.IMeter" />
|
|||
|
|
</member>
|
|||
|
|
<member name="E:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.OnMeasurementCompleted">
|
|||
|
|
<inheritdoc cref="T:Xylem.Common.Hardware.WaterMeter.WaterMeterCore.IMeter" />
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.OnAuthorizationRequired">
|
|||
|
|
<summary>
|
|||
|
|
call this if session is expired and you need an re-authorization
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.Invoker(System.EventHandler,System.Object,System.EventArgs)">
|
|||
|
|
<summary>
|
|||
|
|
A helper to invoke events only if someone is listening, otherwise nothing will happen
|
|||
|
|
</summary>
|
|||
|
|
<param name="handler">Event handler to call</param>
|
|||
|
|
<param name="sender">Sender (can be null)</param>
|
|||
|
|
<param name="e">Event arguments (can be null)</param>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.StreamingProtocol_ApplyDecodedRecord(System.Object,Xylem.Common.Hardware.WaterMeter.Genesis.DataPackages.EventArguments.BaseDataEventArgs)">
|
|||
|
|
<summary>
|
|||
|
|
Track all incoming led record packages (Calibration and Flow)
|
|||
|
|
</summary>
|
|||
|
|
<param name="sender"></param>
|
|||
|
|
<param name="e">
|
|||
|
|
I should be <see cref="T:Xylem.Common.Hardware.WaterMeter.Genesis.DataPackages.MeasurementRecords.FlowTestRecord" /> or <see cref="T:Xylem.Common.Hardware.WaterMeter.Genesis.DataPackages.EventArguments.CalibDataEventArgs" />
|
|||
|
|
otherwise this method does nothing
|
|||
|
|
</param>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.RequestProtocol_ApplyDecodedRecord(System.Object,Xylem.Common.Hardware.WaterMeter.Genesis.DataPackages.EventArguments.BaseDataEventArgs)">
|
|||
|
|
<summary>
|
|||
|
|
tracking request record processing
|
|||
|
|
</summary>
|
|||
|
|
<param name="sender"></param>
|
|||
|
|
<param name="e"></param>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.QueryCaps">
|
|||
|
|
<summary>
|
|||
|
|
QueryCaps can send before login
|
|||
|
|
arrange record for communication (e.g. Baud rate)
|
|||
|
|
</summary>
|
|||
|
|
<returns>
|
|||
|
|
Running outgoing command
|
|||
|
|
</returns>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter._backupLoginLvl">
|
|||
|
|
<summary>
|
|||
|
|
The backup login level is needed for re-authorization
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.PrivilegeCommandToMeter(System.Int32,System.Boolean)">
|
|||
|
|
<summary>
|
|||
|
|
SetRegister <see cref="F:Xylem.Common.Hardware.WaterMeter.Genesis.Registers.Register.Configexchange.Privilege" /> to loginLvl and wait for response
|
|||
|
|
</summary>
|
|||
|
|
<param name="loginLvl"></param>
|
|||
|
|
<param name="runImmediately"> true = process command; false = add command to list. call
|
|||
|
|
<see cref="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.RequestProtocolProcess"></see> to process login command </param>
|
|||
|
|
<returns> if is completed and no error occurred it is true </returns>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.LoginCommandToMeter(System.String,System.Boolean)">
|
|||
|
|
<summary>
|
|||
|
|
Set <see cref="F:Xylem.Common.Hardware.WaterMeter.Genesis.Registers.Register.Configexchange.Password" />
|
|||
|
|
</summary>
|
|||
|
|
<param name="password"> if null , use password from initialization</param>
|
|||
|
|
<param name="runImmediately"> true = process command; false = add command to list. call
|
|||
|
|
<see cref="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.RequestProtocolProcess"></see> to process login command </param>
|
|||
|
|
<returns>
|
|||
|
|
</returns>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.ReLogin">
|
|||
|
|
<summary>
|
|||
|
|
Login with identical password as last time
|
|||
|
|
</summary>
|
|||
|
|
<returns></returns>
|
|||
|
|
<remarks date="2019-Jun-23" author="Thomas Wiedebusch">
|
|||
|
|
- Initial
|
|||
|
|
</remarks>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.Login">
|
|||
|
|
<inheritdoc />
|
|||
|
|
<remarks date="2018JAN08" author="drabesch">
|
|||
|
|
Get password from server
|
|||
|
|
</remarks>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.Login(System.String)">
|
|||
|
|
<inheritdoc />
|
|||
|
|
<summary>
|
|||
|
|
Starting a timer to keep session active,
|
|||
|
|
starting the <see cref="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.KeepSessionThreadLoop"/>.
|
|||
|
|
</summary>
|
|||
|
|
<param name="password">password string to login</param>
|
|||
|
|
<returns></returns>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.Login(System.String,System.Boolean)">
|
|||
|
|
<summary>
|
|||
|
|
Starting a timer to keep session active,
|
|||
|
|
starting the <see cref="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.KeepSessionThreadLoop"/>.
|
|||
|
|
</summary>
|
|||
|
|
<param name="password">password string to login</param>
|
|||
|
|
<param name="runImmediately"> true = process command; false = add command to list. call
|
|||
|
|
<see cref="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.RequestProtocolProcess"></see> to process login command </param>
|
|||
|
|
<returns></returns>
|
|||
|
|
<remarks date="2019JAN01" author="drabesch">
|
|||
|
|
pass runImmediately for auto login
|
|||
|
|
</remarks>
|
|||
|
|
<remarks date="2021-Feb-02" author="Thomas Wiedebusch">
|
|||
|
|
- Avoid retries during login, a retry will lock the Genesis for 2s, 4s, 8s, 16s and so on.
|
|||
|
|
</remarks>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.BuildFwVersionString(System.Byte,System.Byte)">
|
|||
|
|
<summary>
|
|||
|
|
Building the FW Version string out of 2 bytes of data.
|
|||
|
|
REASON: FLEXNETVERSION is one application which does not follow the same rule of
|
|||
|
|
decimal numbers. Instead it uses hexadecimal digits. After the conversion of this
|
|||
|
|
number to a pure Uint32, needed for comparison of file versions in configuration.json,
|
|||
|
|
the hexadecimal outline will be lost and the comparison with the rowproduct.txt fails.
|
|||
|
|
FW-update needs this information to validate a tested package!
|
|||
|
|
</summary>
|
|||
|
|
<param name="msb">most significant byte</param>
|
|||
|
|
<param name="lsb">last significant byte</param>
|
|||
|
|
<returns>converted "msb.lsb" as string e.g. "12.34" or "2.0C" </returns>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.MeterAppListVersion">
|
|||
|
|
<summary>
|
|||
|
|
List of all present meter applications
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.CoreRevision">
|
|||
|
|
<summary>
|
|||
|
|
Core revision of boot code.
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.RegionRadio">
|
|||
|
|
<summary>
|
|||
|
|
Region (EMEA or NA) and Radio frequency (433 or 868 or null).
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.MetrologyUpgradePermission">
|
|||
|
|
<summary>
|
|||
|
|
Metrology upgrade permission.
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.ReadMeterFirmwareAndAssignRegisters">
|
|||
|
|
<summary>
|
|||
|
|
Reading all applications which can be found in the configuration.json and have been stored
|
|||
|
|
to the meter register dictionary in advance.
|
|||
|
|
The read process covers the FW version and the CRC.
|
|||
|
|
After reading the version, all valid registers are going to be selected.
|
|||
|
|
</summary>
|
|||
|
|
<remarks date="2021-Mar-10" author="Thomas Wiedebusch">
|
|||
|
|
- Removed "Cordonel " from CoreRevision to have the e.g. "1.64" remaining
|
|||
|
|
</remarks>
|
|||
|
|
<remarks date="2021-Apr15" author="Thomas Wiedebusch">
|
|||
|
|
- Read radio frequency
|
|||
|
|
</remarks>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.EnableAutoLogon">
|
|||
|
|
<summary>
|
|||
|
|
Automatic login to meter enabled if logged out by lost authentication
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.KeepSessionTimerElapsed_SyncKeepSessionThread(System.Object,System.Timers.ElapsedEventArgs)">
|
|||
|
|
<summary>
|
|||
|
|
If the timeout timer elapsed to keep the session active, this routine will be called
|
|||
|
|
awaking the <see cref="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.KeepSessionThreadLoop"/>.
|
|||
|
|
</summary>
|
|||
|
|
<param name="sender"></param>
|
|||
|
|
<param name="eventARgs"></param>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.KeepSessionThreadLoop">
|
|||
|
|
<summary>
|
|||
|
|
Thread to keep the connection to the meter open and the session alive,
|
|||
|
|
because on missing communication the meter is going to logout automatically.
|
|||
|
|
This thread will be started at <see cref="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.Login"/> and aborted on
|
|||
|
|
<see cref="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.Logout"/>
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.Logout">
|
|||
|
|
<inheritdoc />
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.CheckStateAfterMeasurement">
|
|||
|
|
<summary>
|
|||
|
|
Check if EMPTY_PIPE or REBOOT is set
|
|||
|
|
</summary>
|
|||
|
|
<returns></returns>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.HasAlarms(Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.Alarm)">
|
|||
|
|
<summary>
|
|||
|
|
Check if alarmToCheck is set on register
|
|||
|
|
</summary>
|
|||
|
|
<param name="alarmToCheck">is Flags so you can use more than one alarms (like Alarm.EMPTY_PIPE | Alarm.REBOOT)</param>
|
|||
|
|
<returns></returns>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.GetAlarms">
|
|||
|
|
<summary>
|
|||
|
|
Read out all AlarmStatus register and combine them to one <see cref="T:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.Alarm"/>
|
|||
|
|
</summary>
|
|||
|
|
<returns></returns>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.ResetAlarm(Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.Alarm)">
|
|||
|
|
<summary>
|
|||
|
|
Reset the empty pipe alarm
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.GetPcbId(System.Int32,System.Int32)">
|
|||
|
|
<summary>
|
|||
|
|
Reads the PCB Identification, can be accessed at all login levels,
|
|||
|
|
Read Privilege is always needed to BUGFIX read access to PCB ID
|
|||
|
|
</summary>
|
|||
|
|
<returns>PCB ID</returns>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.GetRegistersDic">
|
|||
|
|
<summary>
|
|||
|
|
Get the actual register dictionary
|
|||
|
|
</summary>
|
|||
|
|
<returns></returns>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.GetSerialNumber">
|
|||
|
|
<summary>
|
|||
|
|
Serial number of meter married with PcbId
|
|||
|
|
</summary>
|
|||
|
|
<returns></returns>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.SetLcdText(System.Boolean,System.Byte[])">
|
|||
|
|
<inheritdoc />
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.RequestProtocol_MeterRegisterUpdated(System.Object,Xylem.Common.Hardware.WaterMeter.Genesis.DataPackages.EventArguments.RegisterUpdatedEventArgs)">
|
|||
|
|
<summary>
|
|||
|
|
Event to Sync Register on MeterSide and <see cref="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter._configRegister" />
|
|||
|
|
Fired on Write or read register
|
|||
|
|
</summary>
|
|||
|
|
<param name="sender"></param>
|
|||
|
|
<param name="e">Register to update with value to update</param>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.WriteRegister``1(System.String,``0,System.Boolean,System.Boolean,System.UInt16)">
|
|||
|
|
<summary>
|
|||
|
|
Write Register, optional: wait for result and validate,
|
|||
|
|
write register will ALWAYS log the data DON'T use for password write
|
|||
|
|
</summary>
|
|||
|
|
<typeparam name="T">Data type of Register</typeparam>
|
|||
|
|
<param name="reg">Register to change</param>
|
|||
|
|
<param name="value">Value to save</param>
|
|||
|
|
<param name="waitForResult">wait until result is ready</param>
|
|||
|
|
<param name="checkRegister">check the content of the register by read back</param>
|
|||
|
|
<param name="skipRetryErrorCode">skip retries on this error code return</param>
|
|||
|
|
<returns>true on successful operation</returns>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.ReadRegister(System.String,System.Nullable{System.Int32},System.UInt16)">
|
|||
|
|
<summary>
|
|||
|
|
Read Register and return byte array
|
|||
|
|
</summary>
|
|||
|
|
<param name="reg"></param>
|
|||
|
|
<param name="expectedLength">expected length for response</param>
|
|||
|
|
<param name="skipRetryErrorCode">skip retries on this error code return</param>
|
|||
|
|
<returns></returns>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.RequestProtocolProcess">
|
|||
|
|
<remarks date="2020-Dec-19" author="Thomas Wiedebusch">
|
|||
|
|
- Removed throw because the throw always kicks in to
|
|||
|
|
the FW-Update process causing an unpredictable stop!
|
|||
|
|
</remarks>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.Clear">
|
|||
|
|
<summary>
|
|||
|
|
Clear Ports
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.DisposeMeter">
|
|||
|
|
<inheritdoc />
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.Dispose">
|
|||
|
|
<inheritdoc />
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.WriteLog(System.String)">
|
|||
|
|
<inheritdoc />
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.LogRawData(System.Boolean)">
|
|||
|
|
<inheritdoc />
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.SetProcessState(Xylem.Common.Hardware.WaterMeter.WaterMeterCore.Consts.DisplayCodes,System.Boolean)">
|
|||
|
|
<inheritdoc />
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.GetLastProcessState">
|
|||
|
|
<inheritdoc />
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.PostRegisterRead(Xylem.Common.Hardware.WaterMeter.Genesis.Registers.RegisterDefinition,System.Byte[])">
|
|||
|
|
<summary>
|
|||
|
|
Logging of register write processes to meter
|
|||
|
|
ATTENTION: DON'T USE FOR PASSWORDS!
|
|||
|
|
</summary>
|
|||
|
|
<param name="reg"></param>
|
|||
|
|
<param name="value"></param>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.LogCalibrationData(System.UInt16,System.UInt16,System.UInt16)">
|
|||
|
|
<summary>
|
|||
|
|
Storage of calibration values
|
|||
|
|
</summary>
|
|||
|
|
<param name="calibrationFactor1"></param>
|
|||
|
|
<param name="calibrationFactor2"></param>
|
|||
|
|
<param name="calibrationFactor3"></param>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter._calibFactor">
|
|||
|
|
<summary>
|
|||
|
|
Calibration factors for all channels
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter._registersToStoreCalibFactor">
|
|||
|
|
<summary>
|
|||
|
|
Registers needed to store the calibration for the individual channel
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.InitCalibration">
|
|||
|
|
<inheritdoc />
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.StartCalibration">
|
|||
|
|
<inheritdoc />
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.StopCalibration">
|
|||
|
|
<inheritdoc />
|
|||
|
|
<summary>
|
|||
|
|
Just stop recording without calculation
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.GetCalibrationState">
|
|||
|
|
<inheritdoc />
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.BuildAndCheckCalibFactorsAllChannels(System.Double,System.Nullable{System.Double},System.Double,System.Double)">
|
|||
|
|
<inheritdoc />
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.SetCalibFactorsAllChannels(System.Boolean)">
|
|||
|
|
<inheritdoc />
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter._listOfIMeasurement">
|
|||
|
|
<summary>
|
|||
|
|
List of ongoing measurements, base- and calibration-measurements
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.AllChannelsRequired">
|
|||
|
|
<summary>
|
|||
|
|
All channels required to process
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.InitMeasurement">
|
|||
|
|
<inheritdoc />
|
|||
|
|
<summary>
|
|||
|
|
Perpetration of Measurement
|
|||
|
|
SampleRate 10 and Led mode Test
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.StartMeasurement">
|
|||
|
|
<inheritdoc />
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.StopMeasurement">
|
|||
|
|
<inheritdoc />
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.CheckChannelFlowDirection">
|
|||
|
|
<summary>
|
|||
|
|
Testing the flow direction
|
|||
|
|
</summary>
|
|||
|
|
<returns></returns>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.GetMainMeasurementResult(System.Nullable{System.Double},System.Nullable{System.Double},System.Boolean)">
|
|||
|
|
<inheritdoc />
|
|||
|
|
<summary>
|
|||
|
|
the first measurement is ALWAYS a FlowTestRecord due to the underlying<see cref="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.GetAllMeasurementResults(System.Nullable{System.Double},System.Nullable{System.Double},System.Boolean,System.Nullable{System.Int32})"/> routine logic.
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.GetAllMeasurementResults(System.Nullable{System.Double},System.Nullable{System.Double},System.Boolean,System.Nullable{System.Int32})">
|
|||
|
|
<summary>
|
|||
|
|
The first measurement is ALWAYS a FlowTestRecord.
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.GetMeasurementState(System.Nullable{System.Int32})">
|
|||
|
|
<inheritdoc />
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter.RequestIntermediateMeasurementState(System.Nullable{System.Int32})">
|
|||
|
|
<inheritdoc />
|
|||
|
|
</member>
|
|||
|
|
<member name="T:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.CalibFactor">
|
|||
|
|
<summary>
|
|||
|
|
Calibration content
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.CalibFactor.IsCalculated">
|
|||
|
|
<summary>
|
|||
|
|
has been calibrated
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.CalibFactor.Channel">
|
|||
|
|
<summary>
|
|||
|
|
Channel for calibration
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.CalibFactor.RegisterToStoreCalibFactor">
|
|||
|
|
<summary>
|
|||
|
|
Register to store the calibration
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.CalibFactor.#ctor(System.Int32,System.String)">
|
|||
|
|
<summary>
|
|||
|
|
Ctor for calibration factor
|
|||
|
|
</summary>
|
|||
|
|
<param name="channel"></param>
|
|||
|
|
<param name="registerToStoreCalibFactor"></param>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.CalibFactor.BuildMeterCalibFactor(System.Double)">
|
|||
|
|
<summary>
|
|||
|
|
set the user readable relative (around 1.0) calibration factor
|
|||
|
|
and convert it to the raw calibration factor for the meter
|
|||
|
|
</summary>
|
|||
|
|
<param name="relativeCalibFactor"></param>
|
|||
|
|
<exception cref="T:System.Exception"></exception>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.CalibFactor.GetRelativeCalibFactor">
|
|||
|
|
<summary>
|
|||
|
|
Read the relative (around 1.0) calibration factor calculated from the actual
|
|||
|
|
meter calibration factor divided by the default calibration factor
|
|||
|
|
</summary>
|
|||
|
|
<returns></returns>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.CalibFactor.GetMeterRawCalibFactorDefault">
|
|||
|
|
<summary>
|
|||
|
|
Genesis internal raw default value (around 15625)
|
|||
|
|
</summary>
|
|||
|
|
<returns></returns>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.CalibFactor.SetMeterRawCalibFactor(System.UInt16)">
|
|||
|
|
<summary>
|
|||
|
|
Set the meter raw calibration factor (around 15625)
|
|||
|
|
</summary>
|
|||
|
|
<param name="meterRawCalibFactor"></param>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.CalibFactor.GetMeterRawCalibFactor">
|
|||
|
|
<summary>
|
|||
|
|
Get the meter raw calibration factor (around 15625)
|
|||
|
|
</summary>
|
|||
|
|
<returns></returns>
|
|||
|
|
</member>
|
|||
|
|
<member name="T:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.MeterPortScanner">
|
|||
|
|
<summary>
|
|||
|
|
Port scanner:
|
|||
|
|
using the Windows Device Manager listed ports,
|
|||
|
|
tries to open the port with an exception if it cannot be accessed (very time consuming),
|
|||
|
|
tries to use the request protocol to detect a Genesis device.
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.MeterPortScanner._currentGenesis">
|
|||
|
|
<summary>
|
|||
|
|
Genesis for test access
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.MeterPortScanner.AutoDetectedPortName">
|
|||
|
|
<summary>
|
|||
|
|
Auto detected port name
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="E:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.MeterPortScanner.OnProcessUpdate">
|
|||
|
|
<summary>
|
|||
|
|
Port scan result event for message dispatcher to caller
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.MeterPortScanner.StopPortScan">
|
|||
|
|
<summary>
|
|||
|
|
Stop the port scan
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.MeterPortScanner.NumberOfPorts">
|
|||
|
|
<summary>
|
|||
|
|
Number of ports
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.MeterPortScanner.ActualPortCtr">
|
|||
|
|
<summary>
|
|||
|
|
Actual Port Counter
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.MeterPortScanner.GetPortScanState">
|
|||
|
|
<summary>
|
|||
|
|
Returns the port scan state
|
|||
|
|
</summary>
|
|||
|
|
<returns></returns>
|
|||
|
|
<remarks date="2020-Oct-21" author="Thomas Wiedebusch">
|
|||
|
|
- Initial
|
|||
|
|
</remarks>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.MeterPortScanner.#ctor(System.String)">
|
|||
|
|
<summary>
|
|||
|
|
Ctor
|
|||
|
|
</summary>
|
|||
|
|
<returns>true if one port has been validated</returns>
|
|||
|
|
<remarks date="2020-Dec-11" author="Thomas Wiedebusch">
|
|||
|
|
- Initial
|
|||
|
|
</remarks>
|
|||
|
|
<param name="portType">type of communication port to meter like IrDA</param>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.MeterPortScanner.Dispose">
|
|||
|
|
<inheritdoc />
|
|||
|
|
<remarks date="2021-Jan-05" author="Thomas Wiedebusch">
|
|||
|
|
- Initial.
|
|||
|
|
</remarks>
|
|||
|
|
<remarks date="2021-Mai-11" author="Thomas Wiedebusch">
|
|||
|
|
- Remove all meters removed as _meterBatch.Dispose will remove all meters.
|
|||
|
|
</remarks>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.MeterPortScanner.ScanAllSerialPorts(System.Int32,System.String)">
|
|||
|
|
<summary>
|
|||
|
|
Use initially the port configuration to speed up search,
|
|||
|
|
If configuration file contains wrong port setup than scan all serial ports listed in
|
|||
|
|
the windows device manager,
|
|||
|
|
Read available ports,
|
|||
|
|
Try to open port and connect to Genesis meter.
|
|||
|
|
</summary>
|
|||
|
|
<param name="slot">slot to search for</param>
|
|||
|
|
<param name="portConfigFilePathName">configuration of port to speed up search</param>
|
|||
|
|
<returns>true if port found</returns>
|
|||
|
|
<returns>true if one port has been validated</returns>
|
|||
|
|
<remarks date="2020-Oct-14" author="Thomas Wiedebusch">
|
|||
|
|
- Initial
|
|||
|
|
</remarks>
|
|||
|
|
<remarks date="2020-Dec-11" author="Thomas Wiedebusch">
|
|||
|
|
- Port type from Ctor,
|
|||
|
|
- Event message changed:
|
|||
|
|
- Overall message: ctr / counts - ongoing scan,
|
|||
|
|
- Actual message: Information to log
|
|||
|
|
</remarks>
|
|||
|
|
<remarks date="2021-Jan-05" author="Thomas Wiedebusch">
|
|||
|
|
- Changed exit of function,
|
|||
|
|
- Added configuration file handling.
|
|||
|
|
</remarks>
|
|||
|
|
<remarks date="2021-Mai-11" author="Thomas Wiedebusch">
|
|||
|
|
- Remove all meters removed as _meterBatch.Dispose will remove all meters.
|
|||
|
|
</remarks>
|
|||
|
|
</member>
|
|||
|
|
<member name="T:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisConfigurationReader">
|
|||
|
|
<summary>
|
|||
|
|
JSON filer reader for generation of register lists
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisConfigurationReader.ConfigRegistersDefinitions">
|
|||
|
|
<summary>
|
|||
|
|
Registers defined in configuration.json file
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisConfigurationReader.ConfigApplicationDefinitions">
|
|||
|
|
<summary>
|
|||
|
|
Applications defined in configuration.json file
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisConfigurationReader.#ctor(System.String)">
|
|||
|
|
<summary>
|
|||
|
|
Ctor
|
|||
|
|
</summary>
|
|||
|
|
<param name="configFilePath">the file path for configuration.json as interface description to the meter</param>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisConfigurationReader.Convert(System.String)">
|
|||
|
|
<summary>
|
|||
|
|
Convert file content to register list
|
|||
|
|
</summary>
|
|||
|
|
<param name="fileContent"></param>
|
|||
|
|
<returns></returns>
|
|||
|
|
<exception cref="T:System.Exception"></exception>
|
|||
|
|
</member>
|
|||
|
|
<member name="T:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Properties.Resources">
|
|||
|
|
<summary>
|
|||
|
|
A strongly-typed resource class, for looking up localized strings, etc.
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Properties.Resources.ResourceManager">
|
|||
|
|
<summary>
|
|||
|
|
Returns the cached ResourceManager instance used by this class.
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Properties.Resources.Culture">
|
|||
|
|
<summary>
|
|||
|
|
Overrides the current thread's CurrentUICulture property for all
|
|||
|
|
resource lookups using this strongly typed resource class.
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Properties.Resources.StrCompareRegister">
|
|||
|
|
<summary>
|
|||
|
|
Looks up a localized string similar to Compare register.
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Properties.Resources.StrPortAccessRequest">
|
|||
|
|
<summary>
|
|||
|
|
Looks up a localized string similar to Access request..
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Properties.Resources.StrPortFailedToOpen">
|
|||
|
|
<summary>
|
|||
|
|
Looks up a localized string similar to Failed to open..
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Properties.Resources.StrPortListDeviceManger">
|
|||
|
|
<summary>
|
|||
|
|
Looks up a localized string similar to Ports listed in the Windows device manager..
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Properties.Resources.StrPortScanStarted">
|
|||
|
|
<summary>
|
|||
|
|
Looks up a localized string similar to Automatic port scan started..
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Properties.Resources.StrPortSuccessfullyAccessed">
|
|||
|
|
<summary>
|
|||
|
|
Looks up a localized string similar to Successfully accessed..
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Properties.Resources.StrReadRegister">
|
|||
|
|
<summary>
|
|||
|
|
Looks up a localized string similar to Read register.
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Properties.Resources.StrReadRegistersAfterUpdate">
|
|||
|
|
<summary>
|
|||
|
|
Looks up a localized string similar to Reading registers after update.
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Properties.Resources.StrReadRegistersBeforeUpdate">
|
|||
|
|
<summary>
|
|||
|
|
Looks up a localized string similar to Reading registers before update.
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Properties.Resources.StrRequestPortDetectionFailed">
|
|||
|
|
<summary>
|
|||
|
|
Looks up a localized string similar to Cordonel not detected!.
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Properties.Resources.StrScanPort">
|
|||
|
|
<summary>
|
|||
|
|
Looks up a localized string similar to Scan port.
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="P:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Properties.Resources.StrWriteRegister">
|
|||
|
|
<summary>
|
|||
|
|
Looks up a localized string similar to Write register.
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="T:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.RegisterRestorer">
|
|||
|
|
<summary>
|
|||
|
|
Read, compare and restore if unequal al registers marked with
|
|||
|
|
<see cref="T:Xylem.Common.Hardware.WaterMeter.Genesis.Registers.DataTypes.StaticType"/> equals
|
|||
|
|
<see cref="!:StaticType.RestoreRequired"/>".
|
|||
|
|
The reader will use the byte values as they are unmodified and
|
|||
|
|
will not be rounded and therefor possibly fail the comparison.
|
|||
|
|
For logging the register value will be converted its unit.
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.RegisterRestorer._pcbIdPreUpdate">
|
|||
|
|
<summary>
|
|||
|
|
PCB ID for pre update for comparison
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.RegisterRestorer._pcbIdPostUpdate">
|
|||
|
|
<summary>
|
|||
|
|
PCB ID for post update for comparison
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.RegisterRestorer._registersPreUpdate">
|
|||
|
|
<summary>
|
|||
|
|
Register content before update
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.RegisterRestorer._registersPostUpdate">
|
|||
|
|
<summary>
|
|||
|
|
Register content after update
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="E:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.RegisterRestorer.OnProcessUpdate">
|
|||
|
|
<summary>
|
|||
|
|
Register access event for message dispatcher to caller
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.RegisterRestorer.ActualRegisterCtr">
|
|||
|
|
<summary>
|
|||
|
|
Actual Port Counter
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.RegisterRestorer.StopRegisterAccess">
|
|||
|
|
<summary>
|
|||
|
|
Stop register access
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.RegisterRestorer._currentGenesis">
|
|||
|
|
<summary>
|
|||
|
|
Genesis meter object
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.RegisterRestorer._restoreRegNames">
|
|||
|
|
<summary>
|
|||
|
|
Extraction of registers names needed to restore after FW-Update
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="F:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.RegisterRestorer._logRegNames">
|
|||
|
|
<summary>
|
|||
|
|
Extraction of registers names needed to log
|
|||
|
|
</summary>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.RegisterRestorer.#ctor(Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter)">
|
|||
|
|
<summary>
|
|||
|
|
Ctor
|
|||
|
|
</summary>
|
|||
|
|
<param name="currentGenesis"></param>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.RegisterRestorer.AssignGenesis(Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.GenesisMeter)">
|
|||
|
|
<summary>
|
|||
|
|
Assign new genesis after reboot and keep the RegisterRestorer object.
|
|||
|
|
</summary>
|
|||
|
|
<param name="genesisMeter"></param>
|
|||
|
|
<remarks date="2020-Dec-19" author="Thomas Wiedebusch">
|
|||
|
|
- Initial
|
|||
|
|
</remarks>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.RegisterRestorer.RegisterRestoreExecuted">
|
|||
|
|
<summary>
|
|||
|
|
Avoid doubling of register restore on subsequent FW-Update trials.
|
|||
|
|
</summary>
|
|||
|
|
<returns>true if registers already backed up</returns>
|
|||
|
|
<remarks date="2020-Dec-21" author="Thomas Wiedebusch">
|
|||
|
|
- Initial.
|
|||
|
|
</remarks>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.RegisterRestorer.RegisterBackupExecuted">
|
|||
|
|
<summary>
|
|||
|
|
Avoid doubling of register backup on subsequent FW-Update trials.
|
|||
|
|
</summary>
|
|||
|
|
<returns>true if registers already backed up</returns>
|
|||
|
|
<remarks date="2020-Dec-19" author="Thomas Wiedebusch">
|
|||
|
|
- Initial.
|
|||
|
|
</remarks>
|
|||
|
|
<remarks date="2020-Dec-21" author="Thomas Wiedebusch">
|
|||
|
|
- Extended checks for Genesis is assigned and PCB ID is identical.
|
|||
|
|
</remarks>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.RegisterRestorer.RestoreRegisters">
|
|||
|
|
<summary>
|
|||
|
|
Restore all registers which can be restored and finalize with "safe configuration process".
|
|||
|
|
</summary>
|
|||
|
|
<returns>true if restoring succeeded</returns>
|
|||
|
|
<remarks date="2020-Dec-17" author="Thomas Wiedebusch">
|
|||
|
|
- Initial.
|
|||
|
|
</remarks>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.RegisterRestorer.CompareRegisters">
|
|||
|
|
<summary>
|
|||
|
|
Compare all registers which can be restored.
|
|||
|
|
</summary>
|
|||
|
|
<returns>true if equal</returns>
|
|||
|
|
<remarks date="2020-Dec-17" author="Thomas Wiedebusch">
|
|||
|
|
- Initial.
|
|||
|
|
</remarks>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.RegisterRestorer.PostUpdateReadRegisters">
|
|||
|
|
<summary>
|
|||
|
|
Read the registers after the update for comparision. Build the post update registers here,
|
|||
|
|
because an update may have changed the registers (new or removed registers).
|
|||
|
|
</summary>
|
|||
|
|
<returns>true if registers could be read</returns>
|
|||
|
|
<remarks date="2020-Dec-08" author="Thomas Wiedebusch">
|
|||
|
|
- Initial.
|
|||
|
|
</remarks>
|
|||
|
|
<remarks date="2020-Dec-20" author="Thomas Wiedebusch">
|
|||
|
|
- Build here the post update registers, they may have changed due to update!
|
|||
|
|
</remarks>
|
|||
|
|
<remarks date="2020-Dec-21" author="Thomas Wiedebusch">
|
|||
|
|
- Clear pre update registers if post indicates a different PCB ID to avoid wrong overwriting of
|
|||
|
|
registers to non matching new meter.
|
|||
|
|
</remarks>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.RegisterRestorer.PreUpdateReadRegisters">
|
|||
|
|
<summary>
|
|||
|
|
Get DEFINED registers from GenesisMeter class and read all
|
|||
|
|
registers which are flagged with read write (RW) or read only (RO).
|
|||
|
|
Build a list of all registers being able to restore referenced by name,
|
|||
|
|
flagged with <see cref="T:Xylem.Common.Hardware.WaterMeter.Genesis.Registers.DataTypes.StaticType"/>
|
|||
|
|
equals <see cref="!:StaticType.RestoreRequired"/>".
|
|||
|
|
The defined registers are based on the "configuration.json" and
|
|||
|
|
the installed application with a specific version.
|
|||
|
|
</summary>
|
|||
|
|
<returns>true if registers could be read</returns>
|
|||
|
|
<remarks date="2020-Dec-08" author="Thomas Wiedebusch">
|
|||
|
|
- Initial.
|
|||
|
|
</remarks>
|
|||
|
|
<remarks date="2020-Dec-17" author="Thomas Wiedebusch">
|
|||
|
|
- Stored registers before and after update.
|
|||
|
|
</remarks>
|
|||
|
|
<remarks date="2020-Dec-18" author="Thomas Wiedebusch">
|
|||
|
|
- Extended register check.
|
|||
|
|
</remarks>
|
|||
|
|
<remarks date="2020-Dec-20" author="Thomas Wiedebusch">
|
|||
|
|
- Removed after update registers and moved them to PostUpdateReadRegisters. They may have changed
|
|||
|
|
during the update.
|
|||
|
|
</remarks>
|
|||
|
|
<remarks date="2020-Dec-21" author="Thomas Wiedebusch">
|
|||
|
|
- Deny register pre update if _pcbIdPreUpdate indicates, that this has been already processed.
|
|||
|
|
</remarks>
|
|||
|
|
</member>
|
|||
|
|
<member name="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.RegisterRestorer.ReadRegistersSet(Xylem.Common.Hardware.WaterMeter.Genesis.Registers.MeterRegisters,System.Collections.Generic.ICollection{System.String})">
|
|||
|
|
<summary>
|
|||
|
|
Register read loop.
|
|||
|
|
All registers needed to be read with <see cref="M:Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.RegisterRestorer.ReadRegistersSet(Xylem.Common.Hardware.WaterMeter.Genesis.Registers.MeterRegisters,System.Collections.Generic.ICollection{System.String})"/>from the Genesis meter as they are only
|
|||
|
|
prepared as template and NOT filled with the register data!
|
|||
|
|
The <see cref="T:Xylem.Common.Utils.ProcessExec.EventArguments.ProcessExecEventArgs"/> uses the overall process text and value for user information process
|
|||
|
|
bar and text and the actual process text for logging to the report file!
|
|||
|
|
</summary>
|
|||
|
|
<param name="registers">registers to read</param>
|
|||
|
|
<param name="registerNames">list of registers to read</param>
|
|||
|
|
<returns>true if registers could be read</returns>
|
|||
|
|
<remarks date="2020-Dec-17" author="Thomas Wiedebusch">
|
|||
|
|
- Initial.
|
|||
|
|
</remarks>
|
|||
|
|
<remarks date="2020-Dec-18" author="Thomas Wiedebusch">
|
|||
|
|
- Set value to actual process message.
|
|||
|
|
</remarks>
|
|||
|
|
<remarks date="2020-Dec-20" author="Thomas Wiedebusch">
|
|||
|
|
- Added PCB ID to logging.
|
|||
|
|
</remarks>
|
|||
|
|
<remarks date="2021-Mar-09" author="Thomas Wiedebusch">
|
|||
|
|
- Removed PCB ID from logging.
|
|||
|
|
</remarks>
|
|||
|
|
</member>
|
|||
|
|
</members>
|
|||
|
|
</doc>
|